• Title/Summary/Keyword: general Industrial sulfur

Search Result 18, Processing Time 0.023 seconds

Density, Absorption and Table Flow properties of the Lower melting Point of the Modified Sulfur and General Industrial Sulfur (일반 공업용 유황과 융점을 낮춘 개질유황의 유동성, 흡수율 및 밀도 특성)

  • Kim, Heon-Tae;Lee, Yong;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.45-46
    • /
    • 2015
  • Recently, the large amount of sulfur is globally generated by the development of the petroleum refining industry every year. In this study, without the use of the sulfur with a high melting point used in the previous studies, the modified sulfur mortar with addition of a melting point of about 65℃ were tested to determine their distribution and strength properties according to the mixing method and curing conditions. This study is a test to find out the Density, Absorption and Table Flow of the modified sulfur and general sulfur. As result, general industrial sulfur flow was lower, showed a high absorption rate.

  • PDF

Binary Mixture Toxicity of AROCLOR 1248, Oleic Acid, and Elemental Sulfur to Vibrio fischeri Luminescence

  • Kalciene, Virginija;Dabkeviciene, Daiva;Cetkauskaite, Anolda
    • Journal of Environmental Science International
    • /
    • v.24 no.11
    • /
    • pp.1541-1546
    • /
    • 2015
  • The objective of this research was to evaluate the toxicity of the industial xenobiotic Aroclor 1248 (A) and natural origin substances~elemental sulfur (S80) and oleic acid (OA) and their binary mixtures to V. fischeri bioluminescence during the prolonged exposure time (up to 60 min). The bioluminescence quenching test was used to determine the toxic effects. Full factorial experiment design and multiple regression analysis and the comparison of binary mixture effect with the sum of effects of individual chemicals were used for the evaluation of combined effects of toxicants. The analysis of general trend of mixture toxicity to bioluminescence showed that mixture toxic effects were reversible up to 60 min. Data analysis revealed different joint effects, which were depended on mixture composition. S80 enhanced toxic effect of A and acted additively with synergistic interaction. Hydrophobic OA in mixture with A acted antagonistically and in mixture with sulfur caused an additive effect with antagonistic component of interaction. It was concluded that low concentrations of natural toxic substances present in environmental samples as mixtures of chemicals can define the toxicodynamic character of industrial xenobiotics.

Air Pollution Effects on Soil Chemical Properties, Lichens, Denitrifying and Sulfur-Reducing Bacteria Around the Yeochun Industrial Estate (여천공단의 대기오염이 토양의 화학적 특성, 지의류, 탈질균 및 황산환원균에 미치는 영향)

  • Yu, Jung-Hwan;Ka, Kang-Hyun;Park, Hyun
    • Journal of Korean Society of Forest Science
    • /
    • v.84 no.2
    • /
    • pp.178-185
    • /
    • 1995
  • Air pollution effects on soil chemical properties, denitrifying and sulfur-reducing bacteria and lichens were examined around the Yeochun industrial estate. Soil samples were collected from mountain and/or mountain edges around the Namhae Chemical Corp., which is located at the southern edge of the estate, and sampled plots which were selected at 2km, 4km, 6km, 8km, and 10km apart from the industrial estate. The forest soils around the industrial estate could be classified into the Reddish yellow forest soil group, but soil pH was quite lower than the soils of the group. Because of the extremely low soil pH, microbial activity related to mineralization of organic matter was expected to be very low even though C/N ratio ranged from 15 to 20. As a result, soil organic matter and total nitrogen in soil were relatively high compared to the soils of the group. In general, soil chemical properties around the industrial estate up to 4km apart from the estate were significantly different from the rest(more than 6km apart from the estate) possibly due to air pollution. However, denitrifying bacteria and sulfur-reducing bacteria did not show significant differences in colony forming units by the distances from the industrial estate. By the way, lichens showed distinct differences in frequencies and coverages by the distances from the industrial estate possibly due to air pollution. The corticolous lichens showed more sensitive response to the air pollution compared to the saxicolous lichens.

  • PDF

The Study on the Level of Air Pollution at Four Department Stores in Pusan Area (부산지역 4개 백화점의 공기오염도에 관한 조사연구)

  • Moon, D.H.;Rhee, HW.;Lee, C.U.
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.164-180
    • /
    • 1991
  • For the purpose of contributing to the promotion of health of the employees working at the same kind of department store or similar type of business and the people utilizing them and preparing the basic data for the establishment of mangagement measure by assessing the level of air pollusion at indoor and outodoor of four department store among the distribution service business in Pusan area, authors measured the concentration of sulfur dioxide, nitrogen dioxide, formaldehyde and total suspanded particle according to the measuring height of variable at indoor and outodoor from Aug. 1990. to sep. an. d Jan, 1991 to Feb.: for each two months in summer and winter, and studied by dividing the variable factor into atmospheric factor (temperature, humidity and air velociy) The results are as follows ; 1. The mean concentration of air pollutants at indoor to total subjects was nitrogen dioxide 31.1ppb, sulfur dioxide 51.7ppb, formaldehyde 162.lppb and total suspanded particle $67.7{\mu}g/m^3$, and it was higher in winter than in summer (P>0.05) 2. The mean concentration of formaldehyde to total subjects was higher indoors than outdoors (P<0.001), in case of nitrogen dioxide there was no significant difference and sulfur dioxide and total suspanded particle were higher outdoors than indoors (P<0.05) 3. The concentration of nitrogen dioxide and sulfur dioxide proved to be a adverse correlation, reducing with height. 4. According to the result questioned about the exposure concentration of pollutant and the general symptom caused by the pollutant, nitorgen dioxide and symptom proved to be a positive correlation (P<0.09).

  • PDF

The Effects of Sulfur on the Catalytic Reaction between Carbon Monoxide and Nitric Oxide on Polycrystalline Platinum Surface (다결정 백금표면에서의 일산화탄소와 일산화질소의 촉매반응에 미치는 황의 영향)

  • Park, Youn-Seok;Kim, Young-Ho;Lee, Ho-In
    • Applied Chemistry for Engineering
    • /
    • v.1 no.2
    • /
    • pp.215-223
    • /
    • 1990
  • The effects of sulfur on the catalytic reaction between CO and NO on polycrystalline Pt surface, which is very important in the development of catalyst for automobile exhaust gas control, have been studied using thermal desorption spectrometry(TDS) under ultra-high vacuum(UHV) conditions. Sulfur weakened both the adsorptions of CO and NO by direct site blocking and indirect electronic effect. S(a) desorbing below 800 K gave little effect on reaction activity whereas S(a) desorbing above 800 K, which adsorbs as an atomic state, gave much effect on it. The adsorbed sulfur existed on the surface of platinum in the form of islands, and also reduced the adsorption energies of adsorbates by the long-ranged electronic effect. The platinum catalyst in the reaction between CO and NO was poisoned selectively by S(a), poisoning firstly the active sites of this reaction.

  • PDF

Characteristics of Atmospheric Concentrations of Toxic Volatile Organic Compounds in Korea (II) - Seasonal and Locational Variations (국내 대기 중 독성 휘발성 유기화합물의 오염 특성(II) -계절 및 지역적 변동)

  • 백성옥;김배갑;박상곤
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.3
    • /
    • pp.207-217
    • /
    • 2002
  • This study was designed to investigate the characteristics of atmospheric concentrations of toxic volatile organic compounds (VOCs) in Korea. Target compounds included 1,3-butadiene, aromatics such as BTEX, and a number of carbonyl compounds. In this paper, as the second part of the study, the seasonal and locational concentrations of atmospheric VOCs were evaluated. Sampling was conducted seasonally at seven sampling sites. each of them representing a large urban area (commercial and residential), a small urban area (commercial and residential), an industrial area (a site within the complex and a residential), and a background place in Korea. In general, higher concentrations were found in the petro-chemical industrial site than other sites, while VOCs measured in commercial (heavy -traffic) sites were higher than residential sites. Seasonality of VOCs concentrations were not so much clear as other combustion related pollutants such as sulfur dioxide, indicating that the VOCs are emitted from a variety of sources, not only vehicle exhaust and point sources but fugitive emissions. Except the industrial site, the concentrations of VOCs measured in this study do not reveal any serious pollution status, since the levels did not exceed any existing ambient standards in the U.K. and/or Japan. However, the increasing number of petrol -powered vehicles and the rapid industrialization in Korea may result in the increased levels of VOCs concentrations in many large urban areas in the near future, if there is no appropriate programme implemented for the control of these compounds.

Elucidation of Intergranular Corrosion of UNS N08810 alloys (UNS N08810 합금의 입계부식손상과 원인 분석)

  • Kim, Youngsik;Hwangbo, Deok
    • Corrosion Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.196-204
    • /
    • 2012
  • Corrosion failure of petrochemical facilities is one of the difficulties in maintenance, since operating conditions of crude oil production, storage, and refinement are very aggressive. UNS N08810, which has been used for crude oil transportation pipes and storage tanks in petrochemical industries, shows good resistance to general corrosion and localized corrosion in several environments. Among its environments, UNS N08810 showed better corrosion resistance in fuel gas containing sulfuric acid and phosphoric acid and sulfur. However, ductility and toughness at high temperature over about $500^{\circ}C$ were greatly reduced due to microstructural change. In general, welding process is the representative method to join the parts in industrial components. Because the alloy by welding can be sensitized and corroded, the manufacturing process should be controlled. In this work, UNS N08810 was used and heat treatment conditions including solution and stabilization treatments were controlled. Oxalic acid etch test by ASTM A262 Practice A was done to evaluate the qualitative sensitization in room temperature. Huey test by ASTM A262 Practice C was done to evaluate the intergranular corrosion rate in boiling 65% $HNO_3$ solution. Also, the microstructure by thermal history was analyzed. Experimental alloy showed high intergranular corrosion rate and its corrosion mechanism was elucidated.

Reaction Force Analysis on the Journal Bearing of Shafting System with Contra-Rotating Propeller (상반회전 프로펠러 축계 저널 베어링 반력해석)

  • Shin, Sang-Hoon;Lee, Seung-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.270-276
    • /
    • 2019
  • According to the International Maritime Organization (IMO) 2020 Regulation, ships operating outside designated emission control areas (ECA) have to use low-sulfur oil with a sulfur content of 0.5% or less by January 2020. To minimize the consumption of high-priced low-sulfur oil, it is urgent to introduce efficient energy-saving devices (ESD), and contra-rotating propeller (CRP) systems are well known to be the most effective one. The shafting system that drives a CRP is composed of an inner shaft and an outer one and has a mutually influential system that is much more complex and heavier than a general shafting system. An initial design was carried out to install a CRP system for the first time in Korea. The purpose of this study is to verify whether the journal bearing meets the classification's design criteria through a bearing reaction force analysis for the classification's approval of the initial design. It is ideal for the thrust of the propeller to act on the center of the shaft, but thrust eccentricity occurs due to the uneven wake caused by the stern shape. Load conditions were applied while considering thrust eccentricity to perform the shaft analysis, and the results were compared with the classification's criteria.

Evaluation of Concrete Materials for Desulfurization Process By-products (황부산물의 콘크리트 원료 활용 가능성 평가)

  • Park, Hye-Ok;Kwon, Gi-Woon;Lee, Kyeong-Ho;Kim, Moon-Jeong;Lee, Woo-Weon;Ryu, Don-Sik;Lee, Jong-Gyu
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.28 no.4
    • /
    • pp.15-22
    • /
    • 2020
  • The landfill gas produced in landfill is generally made up of methane(CH4) and carbon dioxide(CO2) of more than 90%, with the remainder made up of hydrogen sulfide(H2S). However, separate pre-treatment facilities are essential as hydrogen sulfide contained in landfill gas is combined with oxygen during the combustion process to generate sulfur oxides and acid rain combined with moisture in the atmosphere. Various desulfurization technologies have been used in Korea to desulfurize landfill gas. Although general desulfurization processes apply various physical and chemical methods, such as treatment of sediment generation according to the CaCO3 generation reaction and treatment through adsorbent, there is a problem of secondary wastes such as wastewater. As a way to solve this problem, a biological treatment process is used to generate and treat it with sludge-type sulfide (S°) using a biological treatment process.In this study, as a basic study of technology for utilizing the biological treatment by-products of hydrogen sulfide in landfill gas, an experiment was conducted to use the by-product as a mixture of concrete. According to the analysis of the mixture concrete strength of sulfur products, the mixture of sulfur by-products affects the strength of concrete and shows the highest strength value when mixing 10%.

Source Apportionment of Fine Particulate Matter (PM2.5) in the Chungju City (충주시 초미세먼지 (PM2.5)의 배출원 기여도 추정에 관한 연구)

  • Kang, Byung-Wook;Lee, Hak Sung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.5
    • /
    • pp.437-448
    • /
    • 2015
  • The purpose of this study is to present the source contribution of the fine particles ($PM_{2.5}$) in Chungju area using the CMB (chemical mass balance) method throughout the four seasons in Korea. The Chungju's annual average level of $PM_{2.5}$ was $48.2{\mu}g/m^3$, which exceeded two times higher than standard air quality. Among these particles, the soluble ionic compounds represent 54.2% of fine particle mass. Additionally, the OC concentration in Chungju stayed similar to other domestic cities, while the EC concentration decreased significantly compared to other domestic/international cities. The concentration of sulfur represented the highest composition (8%) among the fine particle compounds. According to the CMB results, the general trend of the $PM_{2.5}$ mass contributors was the following: secondary aerosols (50.5%: ammonium sulfate 26.5% and ammonium nitrate 24.0%) > gasoline vehicle (18.3%) > biomass burning (11.0%) > industrial boiler (6.0%) > diesel vehicles (4.4%). The contribution of the secondary aerosols was the main cause than others. This impact is assumed to be emitted from air pollutants of urban cities or neighbor countries such as China.