• Title/Summary/Keyword: gauze

Search Result 244, Processing Time 0.033 seconds

Development of Multidiretion Incoming Salt Collector (다방향 비래염분 포집기 개발 및 포집 정확도 검증)

  • Park, Dong-Cheon;Ahn, Jae-Cheol;Kim, Woo-Jae;Oh, Sang-Gyun;Kim, Hyo-Youl;Kang, Byung-Hi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.13-14
    • /
    • 2011
  • Reinforced concrete structures are damaged by concrete carbonation, salt attack, and sulfate attack. The evaluation of the amount of chloride ion from the sea is very important to assess the life expectancy of Reinforced Concrete structures. The incoming salt collector which is developed in Japan has been used until the present, Unfortunately, the incoming salt collector has had a bad reputation which is caused by backward wind. The wind from backward causes the reduction of the amount of collected salt in collector's gauze. The collector was developed for excluding the effect of backward wind. The performance of it was verified from analytic and experimental methods.

  • PDF

Investigation of the mechanism of Ni-P alloy deposition using by in-situ surface pH measurement during electrodeposition (음극표면 pH 측정에 의한 Ni-P합금의 전착기구 고찰)

  • 이규환;장도연;김동수;이상열;권식철;강성군
    • Journal of the Korean institute of surface engineering
    • /
    • v.35 no.2
    • /
    • pp.93-100
    • /
    • 2002
  • To better understand the codeposition mechanism of phosphorous, surface pH and potential of cathode were measured during electrodeposition of Ni-P alloys. The pH of cathode surface was measured using a flat-bottom glass pH electrode and a 500 mesh gold gauze as cathode. The cathode surface pH was increased with increasing the current density and always higher than the pH in the bulk solution. As a result of overplotting the surface pH and cathode potential on the Pourbaix diagram, it was found that cathode surface shift to the domain of predominant of $H_2$$PO3$-or $H_2$$PO_2$-. Additionally, new deposition mechanism was suggested that $H_2$ $PO_2$- and $H_2$$PO_3$- play important roles in the deposition reaction of Ni-P alloys.

A study on the effect of solid materials on the streaming electrification of insulating oil (절연유의 유동대전에 미치는 고체재질의 영향에 관한 연구)

  • 김용운;임헌찬;김영일;김영봉;이덕출
    • Electrical & Electronic Materials
    • /
    • v.7 no.3
    • /
    • pp.236-242
    • /
    • 1994
  • In this paper, the streaming electrification characteristics of insulating oil were examined when the oil is contacted with solid materials in a circulating system. The streaming current($I_s$) increases with increasing oil velocity and temperature, and electrification properties depend on species of metal materials. $I_s$ in the gauze-contained electrification apparatus increases with increasing oil temperature below the temperature of 43[>$^{\circ}C$], but decreases above 43[>$^{\circ}C$]. On the other hand, $I_s$ is positive electrificated for the pipe of Fe, Cu, while it is negative electrificated for Sus. When insulating oil flows through a car fuel filter, $I_s$ increases linearly with increasing oil temperature.

  • PDF

A Case of Pompholyx Treated with Wet Dressing by Distilled Solution of Gamihwangryunhaedok-tang(Jiaweihuanglianjiedu-tang) (加味黃連解毒湯 증류액을 이용한 한포진 치험 1례)

  • Lim Jin-ho;Jee Seon-young;Lee Sang-kon
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.17 no.2
    • /
    • pp.127-130
    • /
    • 2004
  • Pompholyx is a special vesicular type of hand and foot dermatitis. It is an acute, chronic or recurrent dermatosis of the fingers, palms and soles, characterized by a sudden onset of many deep-seated pruritic clear vesicles. We diagnosed a patient with pompholyx as damp heat and treated with wet dressing by gauze soaked in distilled solution of Gamihwangryunhaedok-tang(Jiaweihuanglianjiedu-tang). After treatment with wet dressing, we observed the improvement. Based on this study, it is considered that wet dressing with Gamihwangryunhaedok-tang(Jiaweihuanglianjiedu-tang) can be applied to the treatment of pompholyx.

  • PDF

Airway management of a patient incidentally diagnosed with Mounier-Kuhn syndrome during general anesthesia

  • No, Hyun-Joung;Lee, Jung-Man;Won, Dongwook;Kang, Pyoyoon;Choi, Seungeun
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.19 no.5
    • /
    • pp.301-306
    • /
    • 2019
  • Mounier-Kuhn syndrome (MKS) is a disease characterized by dilation of the trachea and mainstem bronchi. Due to the risk of airway leakage, pulmonary aspiration, and tracheal damage, MKS can be fatal in patients undergoing tracheal intubation. Moreover, MKS may not be diagnosed preoperatively due to its rarity. In this case, a patient undergoing neurosurgery was incidentally diagnosed with MKS during general anesthesia. During anesthesia induction, difficulties in airway management led the anesthesiologist to suspect MKS. Airway leakage was resolved in this case using oropharyngeal gauze packing. Anesthesiologists should be aware of the possibility of MKS and appropriate management of the airways.

Postoperative care after lymphaticovenous anastomosis

  • Chan, Jeffrey C.Y.;Taranto, Giuseppe Di;Elia, Rossella;Amorosi, Vittoria;Sitpahul, Ngamcherd;Chen, Hung-Chi
    • Archives of Plastic Surgery
    • /
    • v.48 no.3
    • /
    • pp.333-335
    • /
    • 2021
  • In this report, we discuss the postoperative protocol for patients undergoing lymphaticovenous anastomosis (LVA) in our unit. Immediately after LVA, the incision site is closed over a small Penrose drain and a simple gauze dressing is applied without compression. In the first 5 days, ambulation is allowed, but limb elevation is actively encouraged to promote lymphatic flow across the newly formed anastomosis. Prophylactic antibiotics are routinely given to prevent infection because this patient group is susceptible to infections, which could trigger thrombosis in the anastomosis.

Accidental Trichloroacetic Acid Burn Injuries on Genital Area during Gynecological Procedures (부인과적 시술 중 발생한 생식기 부위의 Trichloroacetic Acid 화학 화상)

  • Lee, Chong Kun;Yu, Sung Hoon;Kim, Dong Chul
    • Journal of the Korean Burn Society
    • /
    • v.24 no.1
    • /
    • pp.18-20
    • /
    • 2021
  • TCA is widely used in cosmetic treatments such as chemical peels, tattoo removal, and also in gynecological procedures for managing cervical intraepithelial neoplasia. However, storage of high concentration of TCA in a gynecology office is a potential hazard, as it may accidentally cause severe chemical burns. We report a case of deep dermal TCA chemical burn on genital area, which occured accidentally and resulted from misuse of high concentration (90%) of TCA coated vaginal gauze packing dressing during gynecological procedures.

The Wound Healing Effect of PDRN(polydeoxyribonucleotide) Material on Full Thickness Skin Defect in the Mouse (흰 쥐의 전층피부 결손에 대한 PDRN (polydeoxyribonucleotide) 제재의 창상치유 효과)

  • Kim, Yo-Han;Lee, Jong-Hoon;Min, Kyung-Hee;Hong, Sung-Hee;Lee, Won-Mi;Jun, Jin-Hyun
    • Archives of Plastic Surgery
    • /
    • v.37 no.3
    • /
    • pp.220-226
    • /
    • 2010
  • Purpose: Many topical agents had been used for burn or wound treatment. An awareness of topical agents on various aspects of wound healing permits the clinician to choose the most appropriate material to advantageously control the wound process and final results. Although polydeoxyribonucleotide (PDRN) was used as a tissue repair stimulating agent in a number of human diseases, such as ulcers and burns, its wound healing effects were largely unreported. We aimed to compare the woundhealing effects of PDRN and common dressing materials on full-thickness skin defect in the mouse. Methods: Full-thickness skin defects were made on the back of mice (N=60). The mice were divided into the following 4 groups according to the dressing used for the wounds: group O (Polydeoxyribonucleotide cream), group I (Polydeoxyribonucleotide solution), group M (Medifoam$^{(R)}$), and group G (dry gauze, control group). We analyzed the gross findings, wound sizes and histological findings for the groups. Results: The rate of wound size was decreased in order of group I, group O, group M and group G. The histological findings revealed that the I group showed more reepithelialization and granulation tissue formation and less inflammatory cell infiltration than the other materials. The grade score of wound healing was increased in order of group I, group O, group M and group G. Conclusion: PDRN applicated wound dressings can be used for treating a full-thickness skin defect wounds. Considering its superior efficacy in comparison to the efficacies of other wound dressings, PDRN soaked gauze dressing should be preferentially used for the treatment of fullthickness skin wounds.

A Study for Safe Storage Time for In-house Sterilized Products in a Korean Hospital (멸균품의 유효기간에 관한 연구 - 포장재와 보관환경 중심으로 -)

  • Yoon, Kesook;Kim, Jeong Hee;Yang, Shin Hye;Chae, Ji Yeun;Lee, Young Mee;Cho, Kyung Sook
    • Quality Improvement in Health Care
    • /
    • v.5 no.2
    • /
    • pp.258-276
    • /
    • 1998
  • This study was conducted to justify the "prescribed shelf life" currently used in Samsung Medical Center and give recommendations based on scientific data to adopt for safe and cost-effective storage times for sterile goods Since the early 1970's, predetermined expiration dating policy has been used in Korea on all in-house sterilized products like any other countries; six months for the supplies wrapped in polyethylene peel pouches and two weeks for the rest. Recently, however, the studies suggest that current standards for preserving the sterility can be changing. It looks like we unnecessarily have too-short expiration date of sterilized supplies, that is far from being cost effective. Certainly, this research is an exciting project, especially in Korea, and will be leading and contributing to the paradigm shift of the conservative concept of shelf life for sterile supplies in Korean healthcare facilities. The major goal of this study was placed on the measurement of the recontamination time in packs wrapped in all kinds of wrapping materials used in S.M.C and stored in various conditions for periods ranging from three months to six months, and then develop a practical standard of "shelf life" based on the analyzed data. Objectives: To measure and compare the recontamination time of sterile packs among wrapppers and storage conditions, and develop a practical standard for the shelf life and storage conditions of sterile products. Samples and Method: The sterile integrity was investigated of the total 1,440 sterile sample packs containing gauze strip($1.5cm{\times}0.5cm$) we prepared and wrapped in nine wrapping materials (randomized reprocessed linens, linens reprocessed 99 times, linens reprocessed 120 times, new kraft paper, used kraft paper, new nonwoven fabrics, 6-time reprocessed nonwoven fabrics, new polyethylene peel pouches, used polyethylene peel pouches), and stored in four locations(closed cabinet of one of the typical wards, open shelf of one of ICUs, open shelf of separate storage room in ER, open shelf in OR), for three to six months, respectively in 1998. Each type of packs were opened weekly and the gauze strips inoculated into Brewer's thioglycollate broth at $35^{\circ}C$ for seven days. Results: There was no growth found for any types of the pack and storage conditions studied. Discussion: This study was conducted in an attempt to identify the possibility of extending the current shelf life for sterile goods we use in a sense of cost effectiveness. The findings suggest that we could extend our expiration dates, that means we can save a lot of materials and personnel time meeded for resterilizing, outdating, recleaning, wrapping, and reshelving. Then it will initiate a great reform in the field of healthcare in Korea, and now we are looking forward to this valuable revolution. We are going to continue this study and take all steps need to apply this new concept to our practice, and then trying to extend to other hospitals.

  • PDF

AN EXPERIMENTAL STUDY OF ELECTROPHYSIOLOGICAL AND HISTOLOGICAL ASSESSMENT ON THE INJURY TYPES IN RABBIT INFERIOR ALVEOLAR NERVE (가토의 하치조 신경 손상 형태에 따른 전기생리학적 및 조직학적 변화에 관한 실험적 연구)

  • Lee, Jae-Eun;Lee, Dong-Keun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.4
    • /
    • pp.679-700
    • /
    • 1996
  • Inferior alveolar nerve dysfunction may be the result of trauma, disease, or iatrogenic injury. Inferior alveolar nerve injury is inherent risk in endodontic therapy, orthognathic surgery of the mandible, and extraction of mandibular teeth, particularly the third molars. The sensory disturbances of inferior alveolar nerve associated with such injury have been well documented clinical problem that is commonly evaluated by several clinical sensory test including Tinels sign, Von Frey test(static light touch detection), directional discrimination, two-point discrimination, pin pressure nociceptive discrimination, and thermal test. These methods used to detect and assess inferior alveolar nerve injury have been subjective in nature, relying on the cooperation of the patients. In addition, many of these techniques are sensitive to differences in the examiners experience and skill with the particular technique. Data obtained at different times or by different examiners are therefore difficult to compare. Prior experimental studies have used electro diagnostic methods(sensory evoked potential) to objectively evaluate inferior alveolar nerve after nerve injury. This study was designed with inferior alveolar nerve of rabbit. Several types of injury including mind, moderate, severe compression and perforation with 19 gauze, 21 gauze needle and 6mm, 10mm traction were applied for taking the sesory evoked ppterntial. Latency and amplitude of injury rabbit inferior alveolar nerve were investigated with sensory evoked potential using unpaired t-test. The results were as follows : 1. Intensity of threshold (T1) was $128{\pm}16{\mu}A$ : latency, $0.87{\pm}0.07$ microsecond : amplitude, $0.4{\pm}0.1{\mu}V$ : conduction velocity, 23.3 m/s in sensory evoked potential of uninjured rabbit inferior alveolar nerve. 2. Rabbit inferior alveolar nerve consists of type II and III sensory nerve fiber. 3. Latency was increased and amplitude was decreased in compression injury. The more injured, the more changed in latency and amplitude. 4. Findings in perforation injury was similar to compression injury. Waveform for sensory evoked potential improved by increasing postinjured time. 5. Increasing latency was prominent in traction injury rabbit inferior alveolar nerve. 6. In microscopic histopathological findings, significant degeneration and disorganization of the internal architecture were seen in nerve facicle of severe compression and 10mm traction group. From the above findings, electrophysiological assessment(sensory evoked potential) of rabbit injured inferior alveolar nerve is reliable technique in diagnosis and prognosis of nerve injury.

  • PDF