• Title/Summary/Keyword: gated SPECT

Search Result 65, Processing Time 0.038 seconds

Comparison between Myocardial Perfusion and Function in Rest State in Coronary Artery Disease - Dipyridamole $^{99m}Tc-MIBI$ SPECT and Rest Gated Blood Pool Scan - (관상동맥질환에서 휴식기의 심근관류 정도와 휴식기 심기능 변화의 비교 - Dipyridamole 부하 $^{99m}Tc-MIBI$ SPECT와 휴식기 Gated Blood Pool Scan -)

  • Choi, Chang-Woon;Lee, Dong-Soo;Kim, Sang-Eun;Bae, Sang-Kyun;Yang, Hyung-In;Chung, June-Key;Lee, Myoung-Mook;Lee, Myung-Chul;Park, Young-Bae;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.265-273
    • /
    • 1992
  • Rest gated blood pool scan (Rest GBP scan) and dipyridamole $^{99m}Tc-MIBI$ SPECT were Performed in 34 patients with or suspected coronary artery disease. Both studies were performed within $2\sim32$ days (mean 8.1 days). A significant correlation was present between left ventricular ejection fraction (r= -0.7356, p<0.001) and peak ejection rate and peak filling rate in rest GBP scan and perfusion defect in MIBI SPECT. And there were acceptable correlations (0.05$26.2{\pm}10.8%$, severe hypokinesia, akinesia or dyskinesia in 16 regions: $78.2{\pm}23.7$, p<0.001). These data indicate there is a significant coupling between the degree of myocardial perfusion and the myocardial functional change in coronary artery disease.

  • PDF

Defect of $^{18}F-FDG$ Uptake Observed in Infarcted Myocardium Showing Reverse Redistribution on Rest / 24-Hour Delayed $^{201}Tl$ Myocardial SPEG after Acute Myocardial Infarction (급성 심근경색 후 휴식 / 24시간 지연 $^{201}Tl$ 심근 SPECT 상 역재분포를 보인 경색심근에서 관찰된 $^{18}F-FDG$ 섭취 결손)

  • Lee, Ho-Young;Paeng, Jin-Chul;Oh, So-Won;Kim, Ji-Yeong;Chung, Woo-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.478-481
    • /
    • 2008
  • Reverse redistribution is frequently observed after revascularization in acute myocardial infarction, and usually regarded as a predictor of viable myocardium on stress/rest and 2- to 4-hour redistribution $^{201}Tl$ SPECT. However, there is not enough report of reverse redistribution in case of 24-hour delayed SPECT, which is commonly used for viability assessment. In this report, a case of reverse redistribution on rest and 24-hour delayed $^{201}Tl$ SPECT is reported with use of automatic segmental quantitative analysis. The myocardium of reverse redistribution was dysfunctional on gated SPECT, and diagnosed as non-viable on $^{18}F-FDG$ PET.

Characteristic Findings of Exercise ECG Test, Perfusion SPECT and Coronary Angiography in Patients with Exercise Induced Myocardial Stunning (게이트 심근관류 SPECT상 운동 유발성 기절심근을 보이는 환자의 운동부하 심전도, 관류 SPECT 및 심혈관 조영술 소견)

  • Ahn, Byeong-Cheol;Seo, Ji-Hyoung;Bae, Jin-Ho;Jeong, Shin-Young;Park, Hun-Sik;Lee, Jae-Tae;Chae, Shung-Chul;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.225-232
    • /
    • 2004
  • Purpose : Transient wall motion abnormality and contractile dysfunction of the left ventricle (LV) can be observed in patients with coronary artery disease due to post-stress myocardial stunning. To understand clinical characteristics of stress induced LV dysfunction, we have compared the findings of exercise stress test, myocardial perfusion SPECT and coronary angiography between subjects with and without post-stress LV dysfunction. Materials and Methods : Among subjects who underwent exercise stress test, myocardial perfusion SPECT and coronary angiography within a month of interval, we enrolled 36 patients with post-stress LV election fraction (LVEF) was $\geq5%$ lower than rest (stunning group) and 16 patients with difference of post-stress and rest LVEF was lesser than 1 %(non-stunning group) for this study. Treadmill exercise stress gated myocardial perfusion SPECT was performed with dual head SPECT camera using 740 MBq Tc-99m MIBI and coronary angiography was also performed by conventional Judkins method. Results : Stunning group had a significantly higher incidence of hypercholesterolemia than non-stunning group(45.5 vs. 7.1%, p=0.01). Stunning group also had higher incidence of diabetes mellitus and lower incidence of hypertension, but these were not statistically significant. Stunning group had larger and more severe perfusion defect in stress perfusion myocardial SPECT than non-stunning group(extent 18.2 vs. 9.2%, p=0.029; severity 13.5 vs. 6.9, p=0.040). Stunning group also had higher degree of reversibility of perfusion defect, higher incidence of positive exercise stress test and higher incidence of having severe stenosis ($80{\sim}99%$) in coronary angiography than non-stunning group, but these were not statistically significant. In stunning group, all of 4 patients without perfusion defect had significant coronary artery stenosis and had received revascularization treatment. Conclusion : Patients with post-stress LV dysfunction had larger and more severe perfusion defect and severe coronary artery stenosis than patients without post-stress LV dysfunction. All of the patients without perfusion defect in stunning group had significant coronary artery stenosis and needed revascularization. Therefore, we suggest that invasive diagnostic procedures and therapeutic interventions might be needed in patients with post-stress LV dysfunction.

Improvement in Regional Contractility of Myocardium after CABG (관상동맥 우회로 수술 환자에서 심근의 탄성도 변화)

  • Lee, Byeong-Il;Paeng, Jin-Chul;Lee, Dong-Soo;Lee, Jae-Sung;Chung, June-Key;Lee, Myung-Chul;Choi, Heung-Kook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.224-230
    • /
    • 2005
  • Purpose: The maximal elastance ($E_{max}$) of myocardium has been established as a reliable load-independent contractility index. Recently, we developed a noninvasive method to measure the regional contractility using gated myocardial SPECT and arterial tonometry data. In this study, we measured regional $E_{max}(rE_{max}$ in the patients who underwent coronary artery bypass graft surgery (CABG), and assessed its relationship with other variables. Materials and Methods: 21 patients (M:F=17:4, $58{\pm}12$ y) who underwent CABG were enrolled. $^{201}TI$ rest/dipyridamole stress $^{99m}Tc$-sestamibi gated SPECT were performed before and 3 months after CABG. For 15 myocardial regions, regional time-elastance curve was obtained using the pressure data of tonometry and the volume data of gated SPECT. To investigate the coupling with myocardial function, preoperative regional $E_{max}$ was compared with regional perfusion and systolic thickening. In addition, the correlation between $E_{max}$ and viability was assessed in dysfunctional segments (thickening <20% before CABG). The viability was defined as improvement of postoperative systolic thickening more than 10%. Results: Regional $E_{max}$ was slightly increased after CABG from $2.41{\pm}1.64 (pre)\;to\;2.78{\pm}1.83 (post)$ mmHg/ml. $E_{max}$ had weak correlation with perfusion and thickening (r=0.35, p<0.001). In the regions of preserved perfusion (${\geq}60%$), $E_{max}$ was $2.65{\pm}1.67$, while it was $1.30{\pm}1.24$ in the segments of decreased perfusion. With regard to thickening, $E_{max}$ was $3.01{\pm}1.92$ mmHg/ml for normal regions (thickening ${geq}40%$), $2.40{\pm}1.19$ mmHg/ml for mildly dysfunctional regions (<40% and ${\geq}20%$), and $1.13{\pm}0.89$ mmHg/ml for severely dysfunctional regions (<20%). $E_{max}$ was improved after CABG in both the viable (from $1.27{\pm}1.07\;to\;1.79{\pm}1.48$ mmHg/ml) and non-viable segments (from $0.97 {\pm}0.59\;to\;1.22{\pm}0.71$ mmHg/ml), but there was no correlation between $E_{max}$ and thickening improvements (r=0.007). Conclusions: Preoperative regional $E_{max}$ was relatively concordant with regional perfusion and systolic thickening on gated myocardial SPECT. In dysfunctional but viable segments, $E_{max}$ was improved after CABG, but showed no correlation with thickening improvement. As a load-independent contractility index of dysfunctional myocardial segments, we suggest that the regional $E_{max}$ could be an independent parameter in the assessment of myocardial function.

Development of a New Cardiac and Torso Phantom for Verifying the Accuracy of Myocardial Perfusion SPECT (심근관류 SPECT 검사의 정확도 검증을 위한 새로운 심장.흉부 팬텀의 개발)

  • Yamamoto, Tomoaki;Kim, Jung-Min;Lee, Ki-Sung;Takayama, Teruhiko;Kitahara, Tadashi
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.389-399
    • /
    • 2008
  • Corrections of attenuation, scatter and resolution are important in order to improve the accuracy of single photon emission computed tomography (SPECT) image reconstruction. Especially, the heart movement by respiration and beating cause the errors in the corrections. Myocardial phantom is used to verify the correction methods, but there are many different parts in the current phantoms in actual human body. Therefore the results using a phantom are often considered apart from the clinical data. We developed a new phantom that implements the human body structure around the thorax more faithfully. The new phantom has the small mediastinum which can simulate the structure in which the lung adjoins anterior, lateral and apex of myocardium. The container was made of acrylic and water-equivalent material was used for mediastinum. In addition, solidified polyurethane foam in epoxy resin was used for lung. Five different sizes of myocardium were developed for the quantitative gated SPECT (QGS). The septa of all different cardiac phantoms were designed so that they can be located at the same position. The proposed phantom was attached with liver and gallbladder, the adjustment was respectively possible for the height of them. The volumes of five cardiac ventricles were 150.0, 137.3, 83.1, 42.7 and 38.6ml respectively. The SPECT were performed for the new phantom, and the differences between the images were examined after the correction methods were applied. The three-dimensional tomography of myocardium was well reconstructed, and the subjective evaluations were done to show the difference among the various corrections. We developed the new cardiac and torso phantom, and the difference of various corrections was shown on SPECT images and QGS results.

  • PDF