• 제목/요약/키워드: gastrostomy tube

검색결과 46건 처리시간 0.023초

이탈된 위루관에 대한 투시경하 변형 Seldinger씨 방법을 이용한 경피적 위루관 재삽입술 (Percutaneous Gastrostomy Tube Reinsertion after Accidental Dislodgement Using Modified Seldinger's Technique)

  • 김주희;김성민;오정탁;최승훈;황의호;한석주
    • Advances in pediatric surgery
    • /
    • 제12권2호
    • /
    • pp.251-256
    • /
    • 2006
  • This case report describes a baby who received a laparoscopic gastrostomy tube insertion, which was dislodged accidentally at $16^{th}$ postoperative day. After the dislodgement, cutaneous tract rapidly closed, and reinsertion seemed to be impossible. However, gastrostomy tube was reinserted safely with fluoroscopy-guided Seldinger's technique under local anesthesia with sedation. This is the unique method of modified Seldinger's technique for reinsertion of gastrostomy tube under local anesthesia and sedation for accidentally dislodged gastrostomy tube. This method was thought to be safe, easy and useful technique for gastrostomy reinsertion after dislodgement of gastrostomy tube.

  • PDF

Duodenal Perforation: Unusual Complication of Gastrostomy Tube Replacement

  • Kim, Soo-Hong;Min, Sa-Hong;Kim, Hyun-Young;Jung, Sung-Eun
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제17권2호
    • /
    • pp.112-115
    • /
    • 2014
  • Feeding gastrostomy is widely used for children with feeding impairment. The replacement of gastrostomy tube is known as an easy and safe procedure. However, various complications associated with replacement of gastrostomy tube were reported, including fistula disruption and colo-cutaneous fistula. For replacement of gastrostomy tube in small children with small stomach, special cautions are needed. Here, we report a rare case of duodenal perforation as an acute complication after the replacement of gastrostomy tube for a 33-month-old girl.

Complications of Gastrostomy and Gastrojejunostomy: The Prevalence in Children

  • Thomas Gestels ;Bruno Hauser;Els Van de Vijver
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제26권3호
    • /
    • pp.156-164
    • /
    • 2023
  • Purpose: This study aimed to provide an overview of the prevalence of the complications of a gastrostomy or a gastrojejunostomy with a low-profile gastric tube in children. The study also examined the effect of presence of the gastrostomy tube on the prevalence of complications. Methods: In this cross-sectional study, parents were invited to complete an online questionnaire. Children aged 0-16 years with a low-profile gastrostomy or gastrojejunostomy tube were included in the study. Results: A total of 67 complete surveys were conducted. The mean age of the included children was seven years. The most common complications during the past week, were skin irritation (35.8%), abdominal pain (34.3%), and the formation of granulation tissue (29.9%). The most common complications during the past six months were skin irritation (47.8%), vomiting (43.4%), and abdominal pain (38.8%). Most complications occurred within the first year after gastrojejunostomy placement and gradually decreased as the duration since the placement of the gastrojejunostomy tube increased. The prevalence of severe complications was rare. Parental confidence in caring for the gastrostomy positively correlated with increases in the duration of the gastrostomy tube. Even so, parental confidence in the care of the gastrostomy tube was reduced in some parents more than a year after its placement. Conclusion: The prevalence of gastrojejunostomy complications in children is relatively high. The incidences of severe complications after the placement of a gastrojejunostomy tube were rare in this study. A lack of confidence in the care of the gastrostomy tube was noted in some parents more than a year after its placement.

비글견에서 복강경을 이용한 위관삽입술의 유용성 평가 연구 (Feasibility Study of Laparoscopic Gastrostomy Tube Placement in Beagle Dogs)

  • 이재웅;박지영;이해범;정성목
    • 한국임상수의학회지
    • /
    • 제32권1호
    • /
    • pp.28-35
    • /
    • 2015
  • 본 연구는 개에서 복강경 위관삽입술(LG)을 시행, 수술시간, 합병증, 유착부를 평가하여 수의분야에서 LG의 유용성을 내시경 유도하 경피 위관삽입술(PEG)에 준하여 확인하였다. 정상 비글견 8마리를 두 군으로 나누어 Tri-Funnel Replacement Gastrostomy tube (Bard Inc., USA, 20 Fr.)와 PEG kit (Ponsky "Pull" PEG Kit$^{(R)}$, Bard Inc., USA, 20 Fr.)를 이용하여 LG 및 PEG를 실시하였다. 위관을 통한 영양 공급은 유지 열량 요구량(MER)을 1일 3회로 나누어 2주간 진행하고 LG와 PEG의 수술 중, 수술 후, 사후로 나누어 평가하였다. 모든 개체에서 위관삽입은 성공적이었고, PEG 군에서의 평균 수술 시간이 LG군에 비해 유의적으로 짧았다(p < 0.05). 위-복막간 유착은 군간 모든 개체에서 양호하게 형성되었으나 평균 유착 길이(AL)와 너비(AW)의 수치가 LG군에서 PEG군에 비해 유의하게 높았다 (p < 0.05). 평균 유착 거리(AD)는 군간 차이를 보이지 않았다(p = 0.182). 본 연구를 통해 개에서 LG는 최소 침습적이면서 쉽고 안전하게, 그리고 효과적으로 장관 영양 공급을 실시할 수 있는 방법임이 확인되었다.

위루관 사용 아동의 일상복 디자인 개발 (Designing everyday clothing for children with gastrostomy tubes)

  • 윤다솜;소아토바 마흘리요;김선화
    • 복식문화연구
    • /
    • 제32권5호
    • /
    • pp.686-695
    • /
    • 2024
  • The purpose of the study was to develop clothing that enhances comfort for children using gastrostomy tubes while maintaining a design that is no different from that of non-disabled children. The discomfort experienced by children with gastrostomy tubes wearing regular daily clothing was investigated through medical papers and blogs of their parents. The designs were then created to address the issues. The results were as follows: Because the location of the gastrostomy tube is in the upper body, four types of clothing items were developed: one sweatshirt for boys, two one-piece dresses for girls, and one windbreaker suitable for both boys and girls. Considering practicality for children's clothing, cotton fabric was prioritized. For sweatshirts and windbreakers, a patched pocket with a dog pattern was placed over the area containing the gastrostomy tube to hide it. Frills were used to conceal the gastrostomy tube in one-piece dresses and designed to allow easy access for eating or disinfecting the area. This study aimed to address the challenges children with gastrostomy tubes face when wearing the regular daily clothes of non-disabled children while also offering aesthetically pleasing designs that enhance convenience for those using gastrostomy tubes. We believe this study will not only raise public awareness of disabilities but also inspire research on future clothing for both children and adults using gastrostomy tubes.

Endoscopic hemostasis using an over-the-scope clip for massive bleeding after percutaneous endoscopic gastrostomy removal: a case report

  • Sun Young Moon;Min Kyu Jung;Jun Heo
    • Clinical Endoscopy
    • /
    • 제55권3호
    • /
    • pp.443-446
    • /
    • 2022
  • Percutaneous endoscopic gastrostomy (PEG) is a common method for providing long-term enteral nutrition to patients. PEG tube placement and removal are relatively safe; generally, a PEG tube can be removed using gentle traction, and excessive bleeding is rare. The over-the-scope clip system is a new device that can be used for gastrointestinal hemostasis and for closing gastrointestinal fistulae. In the present case, a 68-year-old male patient had to remove the PEG tube because of persistent leakage around the PEG tube. Although it was gently removed using traction, incessant bleeding continued, with a Rockall score of 5 points, even after hemocoagulation was attempted. An over-the-scope clip device was used to achieve hemostasis and fistula closure.

Acute Shunt Malfunction Caused by Percutaneous Endoscopic Gastrostomy without Shunt Infection

  • Choi, Jingyu;Ki, Seung Seog;Park, Seoungwoo
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권4호
    • /
    • pp.361-363
    • /
    • 2014
  • Percutaneous endoscopic gastrostomy tube placement is often performed in patients with a ventriculoperitoneal shunt and it has been accepted as a safe procedure. The authors report a case of a 50-year-old male who developed acute exacerbation of the hydrocephalus immediately after the percutaneous endoscopic gastrostomy tube placement without any signs of shunt infection, which has not been reported until now. After revision of the intraperitoneal shunt catheter, the sizes of the intracranial ventricles were normalized.

To Button or Not to Button? Primary Gastrostomy Tubes Offer No Significant Advantage Over Buttons

  • Osei, Hector;Munoz-Abraham, Armando Salim;Martino, Alice;Chatoorgoon, Kaveer;Greenspon, Jose;Fitzpatrick, Colleen;Villalona, Gustavo A.
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제25권3호
    • /
    • pp.211-217
    • /
    • 2022
  • Purpose: Outcomes between primary gastrostomy tubes and buttons (G-tube and G-button) have not been established in pediatric patients. We hypothesized that primary G-tube have decreased complications when compared to G-button. Methods: A retrospective review of surgically placed gastrostomy devices from 2010 to 2017 was performed. Data collected included demographics, outcomes and 90-day complications. We divided the patients into primary G-tube and primary G-button. Results: Of 265 patients, 142 (53.6%) were male. Median age and weight at the time of surgery were 7 months (interquartile range [IQR], 2-44 months) and 6.70 kg (IQR, 3.98-14.15 kg), respectively. Among the groups, G-tube had 80 patients (30.2%) while G-button 185 patients (69.8%). There were 153 patients with at least one overall complication within 90 days postoperative. There was no significant difference in overall complications between groups (G-tube 63.8% vs. G-button 55.7%, p=0.192). More importantly, there were no significant differences in major complications among the groups, G-tube vs. G-button (5% vs. 4%; p=0.455). Conclusion: Primary G-tube offers no significant advantage in overall, minor or major complications when compared to primary G-button.

Clinical practice guidelines for percutaneous endoscopic gastrostomy

  • Chung Hyun Tae;Ju Yup Lee;Moon Kyung Joo;Chan Hyuk Park;Eun Jeong Gong;Cheol Min Shin;Hyun Lim;Hyuk Soon Choi;Miyoung Choi;Sang Hoon Kim;Chul-Hyun Lim;Jeong-Sik Byeon;Ki-Nam Shim;Geun Am Song;Moon Sung Lee;Jong-Jae Park;Oh Young Lee
    • Clinical Endoscopy
    • /
    • 제56권4호
    • /
    • pp.391-408
    • /
    • 2023
  • With an aging population, the number of patients with difficulty in swallowing due to medical conditions is gradually increasing. In such cases, enteral nutrition is administered through a temporary nasogastric tube. However, the long-term use of a nasogastric tube leads to various complications and a decreased quality of life. Percutaneous endoscopic gastrostomy (PEG) is the percutaneous placement of a tube into the stomach that is aided endoscopically and may be an alternative to a nasogastric tube when enteral nutritional is required for four weeks or more. This paper is the first Korean clinical guideline for PEG developed jointly by the Korean College of Helicobacter and Upper Gastrointestinal Research and led by the Korean Society of Gastrointestinal Endoscopy. These guidelines aimed to provide physicians, including endoscopists, with the indications, use of prophylactic antibiotics, timing of enteric nutrition, tube placement methods, complications, replacement, and tube removal for PEG based on the currently available clinical evidence.

Wire Guided Cannulation Facilitates Endoscopic Management of Buried Bumper Syndrome: A Novel Technique

  • Peck, Jacquelin;Sapp, Kaitlin;Wilsey, Alexander;Wilsey, Michael
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제22권1호
    • /
    • pp.86-89
    • /
    • 2019
  • Buried bumper syndrome is a rare but potentially severe complication of percutaneous endoscopic gastrostomy tube insertion. Though this complication is uncommon, it may lead to pressure necrosis, bleeding, perforation, peritonitis, sepsis, or death. Each case of buried bumper syndrome is unique in terms of patient comorbidities and anatomic positioning of the buried bumper. For this reason, many approaches have been described in the management of buried bumper syndrome. In this case report, we describe the case of an adolescent Caucasian female who developed buried bumper syndrome three years after undergoing percutaneous endoscopic gastrostomy insertion. We review diagnosis and management of buried bumper syndrome and describe a novel technique for bumper removal in which we use a guide wire in combination with external traction to maintain a patent gastrostomy lumen while removing the internal percutaneous endoscopic gastrostomy bumper.