• Title/Summary/Keyword: gas-slurry

Search Result 158, Processing Time 0.024 seconds

Analysis of Changing Pattern of Noxious Gas Levels with Malodorous Substance Concentrations in Individual Stage of Pig Pens for 24 hrs to Improve Piggery Environment (돈사환경 개선을 위한 생육단계별 돈사내 악취물질 농도 및 유해가스의 1일 변화추세 분석)

  • You, Won-Gyun;Kim, Cho-Long;Lee, Myung-Gyu;Kim, Dong-Kyun
    • Journal of Animal Environmental Science
    • /
    • v.18 no.1
    • /
    • pp.25-34
    • /
    • 2012
  • Noxious gases with malodorous substance concentrations in each stages of pig buildings were determined at a typical 400sow-scale farm to improve piggery environment. Using IAQ-300 and pDR-1000AN, continuous records for the concentration of $NH_3$, CO, $CO_2$, $NO_2$, $SO_2$, $H_2S$, $O_2$, and along with temperature, humidity, dust concentrates from individual pig pens were collected to analyze every 6 hours' condition of indoor environment for 24 hours' period. In most pig houses, the air quality at noon was good, while at night (00:00~06:00), air composition became noxious in all buildings. The order of buildings' air quality for 24 hrs was pregnant > farrowing > nursery > growing > finishing. The cause of air quality differences was presumed to be the differences of stocking density, defecating amount and the length of exposure time of slurry in indoors. In conclusion, well-designed building structure, proper control of stocking density, quick removal of excreta from pig pens and continuous ventilation are prerequisites to improve pig housing environment.

Measuring the Environment of Pig Houses (돈사의 환경계측에 관한 연구)

  • 최규홍;손재룡;이강진;최동수;최용삼;남상일
    • Journal of Animal Environmental Science
    • /
    • v.7 no.3
    • /
    • pp.155-164
    • /
    • 2001
  • Environmental factors such as $NH_3,\;H_2S,\;CO_2$, dust, temperature, and humidity in the animal house are a potential health hazard to humans and animals. Until now, most of measurement methods can only provide periodic results with low accuracy. A data acquisition system which can measure continuously and simultaneously $NH_3,\;H_2S,\;CO_2$, temperature, and humidity was developed and installed in two pig houses. Daily changes of environment for the pig-houses were investigated by the data acquisition system. In order to evaluate NH$_3$sensor, gas samples were obtained and NH$_3$concentrations were measured at nine positions; combinations of three positions(inlet, middle, and outlet) and three heights(0 cm, 40 cm, 150 cm). Ammonia concentration of 14.0 ~37.1 ppm for slurry pig-house is higher than that of 8.4~29.7 ppm for scraper pig-house, and there were no statistical differences among the positions. However, the concentration of $NH_3$at 150 cm was higher than thats of 0 cm and 40 cm.

  • PDF

Optimization of anode and electrolyte microstructure for Solid Oxide Fuel Cells (고체산화물 연료전지 연료극 및 전해질 미세구조 최적화)

  • Noh, Jong Hyeok;Myung, Jae-ha
    • Korean Chemical Engineering Research
    • /
    • v.57 no.4
    • /
    • pp.525-530
    • /
    • 2019
  • The performance and stability of solid oxide fuel cells (SOFCs) depend on the microstructure of the electrode and electrolyte. In anode, porosity and pore distribution affect the active site and fuel gas transfer. In an electrolyte, density and thickness determine the ohmic resistance. To optimizing these conditions, using costly method cannot be a suitable research plan for aiming at commercialization. To solve these drawbacks, we made high performance unit cells with low cost and highly efficient ceramic processes. We selected the NiO-YSZ cermet that is a commercial anode material and used facile methods like die pressing and dip coating process. The porosity of anode was controlled by the amount of carbon black (CB) pore former from 10 wt% to 20 wt% and final sintering temperature from $1350^{\circ}C$ to $1450^{\circ}C$. To achieve a dense thin film electrolyte, the thickness and microstructure of electrolyte were controlled by changing the YSZ loading (vol%) of the slurry from 1 vol% to 5 vol. From results, we achieved the 40% porosity that is well known as an optimum value in Ni-YSZ anode, by adding 15wt% of CB and sintering at $1350^{\circ}C$. YSZ electrolyte thickness was controllable from $2{\mu}m$ to $28{\mu}m$ and dense microstructure is formed at 3vol% of YSZ loading via dip coating process. Finally, a unit cell composed of Ni-YSZ anode with 40% porosity, YSZ electrolyte with a $22{\mu}m$ thickness and LSM-YSZ cathode had a maximum power density of $1.426Wcm^{-2}$ at $800^{\circ}C$.

Bacterial Community Dynamics during Swine In vitro Fermentation Using Starch as a Substrate with Different Feed Additives for Odor Reduction

  • Alam, Md.J.;Jeong, C.D.;Mamuad, L.L.;Sung, H.G.;Kim, D.W.;Cho, S.B.;Lee, K.;Jeon, C.O.;Lee, Sang-S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.25 no.5
    • /
    • pp.690-700
    • /
    • 2012
  • The experiment was conducted by in vitro fermentation and bacterial community analysis to investigate the reduction of odorous compounds in response to the use of feed additives (FA) during carbohydrate overload in growing pigs. Soluble starch at 1% (control) and various FA at 0.1% Ginseng meal (FA1); Persimmon leaf (FA2); Gingko nut (FA3) and Oregano lippia (FA4) were added to fecal slurry and incubated anaerobically for 12 and 24 h. In vitro parameters and microbial diversity of the dominant bacteria following fermentation were analyzed using Denaturing Gradient Gel Electrophoresis (DGGE), band cloning and sequencing of the V3 region. Results showed that total gas production increased with the advancement of incubation (p<0.05). pH values of FAs and control groups were decreased except the FA4 group which increased somewhat from 12 to 24 h (p<0.05). Ammonia nitrogen ($NH_3$-N) and $H_2S$ gas concentrations were comparatively lower in both stages in FA4 treatment than in the other groups (p<0.05). Hence, $NH_3$-N concentrations in liquid phases were increased (p<0.05) from 12 to 24 h, but the trend was lowest in FA4 than in the other groups at both stages. The total VFA production was comparatively lower and butyrate levels were moderate in FA4 group than in the the other groups during both stages (p<0.05). Indirect odor-reducing compounds such as $NO_2$, $NO_3$ and $SO_4$ concentrations were higher in the FA4 and FA3 than in the other groups at 24 h (p<0.05). After fermentation, ten dominant bands appeared, six of which appeared in all samples and four in only the FA4 treated group. The total number of DGGE bands and diversity was higher in the FA4-group compared to other groups. Additionally, similarity indices were lowest (71%) in the FA4, which represented a different bacterial community compared with the other groups. These findings indicate that $NH_3$-N, $H_2S$ and VFA production was minimal, and pH was also better in the FA4 group than in the other groups. Furthermore, the conversion of odor-reducing indirect compounds or their intermediates was higher in the FA4 group in compared to the other groups. FA4 group generated less odorous products and more indirect products by in vitro fermentation at 24 h, and their microbial pattern appeared to differ from that of the other groups. These findings suggest that this particular FA could change the microbial population, which may have a beneficial effect on odor reduction. It is recommended that the oregano lippia may be supplied to growing pigs as FA along with excess carbohydrate sources to reduce the production of odorous compounds.

Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation (지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가)

  • 윤명오;고재선;박형주;박성은
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-33
    • /
    • 2001
  • The utility tunnels are the important facility as a mainstay of country because of the latest communication developments. However, the utilities tunnel is difficult to deal with in case of a fire accident. When a cable burns, the black smoke containing poisonous gas will be reduced. This black smoke goes into the tunnel, and makes it difficult to extinguish the fire. Therefore, when there was a fire in the utility tunnel, the central nerves of the country had been paralyzed, such as property damage, communication interruption, in addition to inconvenience for people. This paper is based on the fire occurred in the past, and reenacting the fire by making the real utilities tunnel model. The aim of this paper is the scientific analysis of the character image of the fire, and the verification of each fire protection system whether it works well after process of setting up a fire protection system in the utilities tunnel at a constant temperature. The fire experiment was equipped with the linear heat detector, the fire door, the connection water spray system and the ventilation system in the utilities tunnel. Fixed portion of an electric power supply cable was coated with a fire retardant coating, and a heating tube was covered with a fireproof. The result showed that the highest temperature was $932^{\circ}c$ and the linear heat detector was working at the constant temperature, and it pointed at the place of the fire on the receiving board, and Fixed portion of the electric power supply cable coated with the fire retardant coating did not work as the fireproof. The heating tube was covered with the fireproof about 30 minutes.

  • PDF

Development of Dust Recycling System and Dust Cleaner in Pipe during Vitrification of Simulated Non-Radioactive Waste (모의 비방사성폐기물의 유리화시 발생 분진의 재순환처리장치 및 배관 내 침적분진에 의한 막힘 방지용 제진장치의 개발)

  • Choi Jong-Seo;You Young-Hwan;Park Seung-Chul;Choi Seok-Mo;Hwang Tae-Won;Shin Sang-Woon
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.110-120
    • /
    • 2005
  • For utilizing vitrification to treat low and intermediate level waste, industrial pilot plant was designed and constructed in October 1999 at Daejon, Korea through the joint research program among NETEC, MOBIS and SGN. More than 70 tests were performed on simulated IER, DAW etc. including key nuclide surrogate(Cs, Co); this plant has been shown to vitrify the target waste effectively and safely, however, some dust are generated from the HTF(High Temperature Filter) as a secondary waste. In case of long term operation, it is also concerned that pipe plugging can be occurred due to deposited dust in cooling pipe namely, connecting pipe between CCM(Cold Crucible Melter) and HTF. In this regard, we have developed the special complementary system of the off-gas treatment system to recycle the dust from HTF to CCM and to remove the interior dust of cooling pipe. Main concept of the dust recycling is to feed the dust to the CCM as a slurry state; this system is regarded as of an important position in the viewpoint of volume reduction, waste disposal cost and glass melt control in CCM. The role of DRS(Dust Recycling System) is to recycle the major glass components and key nuclides; this system is served to lower glass viscosity and increase waste solubility by recycling B, Na, Li components into glass melt and also to re-entrain and incorporate into glass melt like Cs, Co. Therefore dust recycling is helpful to control the molten glass; it is unnecessary to consider a separate dust treatment system like a cementation equipment. The effects of Dust Cleaner are to prevent the pipe plugging due to dust and to treat the deposited dust by raking the dust into CCM. During the pilot vitrification test, overall performance assessment was successfully performed; DRS and Dust Cleaner are found to be useful and effective for recycling the dust from HTF and also removing the dust in cooling pipe. The obtained operational data and operational experiences will be used as a basis of the commercial facility.

  • PDF

Recent Progress in Air Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2007 (설비공학 분야의 최근 연구 동향 : 2007년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Shin, Dong-Sin;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.844-861
    • /
    • 2008
  • The papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during the year of 2007 have been reviewed. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro nano fluid, micropump and fuel cell. Traditional CFD was still popular and widely used in research and development. Studies about fans and pumps were performed in the field of fluid machinery. Characteristics of flow and fin shape optimization are studied in the field of piping system. (2) The research works on heat transfer have been reviewed in the field of heat transfer characteristics, heat exchangers, and desiccant cooling systems. The research on heat transfer characteristics includes thermal transport in pulse tubes, high temperature superconductors, ground heat exchangers, fuel cell stacks and ice slurry systems. For the heat 'exchangers, the research on pin-tube heat exchanger, plate heat exchanger, condensers and gas coolers has been cordially implemented. The research works on heat transfer augmenting tubes have been also reported. For the desiccant cooling systems, the studies on the design and operating conditions for desiccant rotors as well as performance index are noticeable. (3) In the field of refrigeration, many papers were presented on the air conditioning system using CO2 as a refrigerant. The issues on the two-stage compression, the oil selection, and the appropriate oil charge were treated. The subjects of alternative refrigerants were also studied steadily. Hydrocarbons, DME and their mixtures were considered and various heat transfer correlations were proposed. (4) Research papers have been reviewed in the field of building facilities by grouping into the researches on heat and cold sources, air conditioning and air cleaning, ventilation and fire research including tunnel ventilation, flow control of piping system, and sound research with drain system. Main focuses have been addressed to the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies were mostly focused on analyzing the indoor environment in various spaces like cars, old tombs, machine rooms, and etc. in an architectural environmental field. Moreover, subjects of various fields such as the evaluation of noise, thermal environment, indoor air quality and development of energy analysis program were researched by various methods of survey, simulation, and field experiment.

Optimization for Ammonia Decomposition over Ruthenium Alumina Catalyst Coated on Metallic Monolith Using Response Surface Methodology (반응표면분석법을 이용한 루테늄 알루미나 메탈모노리스 코팅촉매의 암모니아 분해 최적화)

  • Choi, Jae Hyung;Lee, Sung-Chan;Lee, Junhyeok;Kim, Gyeong-Min;Lim, Dong-Ha
    • Clean Technology
    • /
    • v.28 no.3
    • /
    • pp.218-226
    • /
    • 2022
  • As a result of the recent social transformation towards a hydrogen economy and carbon-neutrality, the demands for hydrogen energy have been increasing rapidly worldwide. As such, eco-friendly hydrogen production technologies that do not produce carbon dioxide (CO2) emissions are being focused on. Among them, ammonia (NH3) is an economical hydrogen carrier that can easily produce hydrogen (H2). In this study, Ru/Al2O3 catalyst coated onmetallic monolith for hydrogen production from ammonia was prepared by a dip-coating method using a catalyst slurry mixture composed of Ru/Al2O3 catalyst, inorganic binder (alumina sol) and organic binder (methyl cellulose). At the optimized 1:1:0.1 weight ratio of catalyst/inorganic binder/organic binder, the amount of catalyst coated on the metallic monolith after one cycle coating was about 61.6 g L-1. The uniform thickness (about 42 ㎛) and crystal structure of the catalyst coated on the metallic monolith surface were confirmed through scanning electron microscopy (SEM) and X-ray diffraction (XRD) analysis. Also, a numerical optimization regression equation for NH3 conversion according to the independent variables of reaction temperature (400-600 ℃) and gas hourly space velocity (1,000-5,000 h-1) was calculated by response surface methodology (RSM). This model indicated a determination coefficient (R2) of 0.991 and had statistically significant predictors. This regression model could contribute to the commercial process design of hydrogen production by ammonia decomposition.