• 제목/요약/키워드: gas-liquid mixing

검색결과 145건 처리시간 0.021초

상온에서 보관한 반코마이신 함유 항생제 시멘트의 메티실린 내성 포도상구균에 대한 항균력 조사 (In Vitro Study Evaluating the Antimicrobial Activity of Vancomycin-Impregnated Cement Stored at Room Temperature in Methicillin-Resistant Staphylococcus aureus)

  • 박세진;조용운;이석원;우희연;임상은
    • 대한족부족관절학회지
    • /
    • 제22권1호
    • /
    • pp.38-43
    • /
    • 2018
  • Purpose: Treatment of diabetic foot infection due to methicillin-resistant Staphylococcus aureus (MRSA) remains challenging. Applying vancomycin-impregnated cement is one of the best methods of treatment. Vancomycin-impregnated cement has been used worldwide; however, to date, there is a limited number of studies regarding its use. We evaluated the duration of antimicrobial activity of vancomycin-impregnated cement stored at room temperature after manufacturing. Materials and Methods: The vancomycin-impregnated cement was manufactured by mixing 1 g of vancomycin with 40 g of polymer and adding 17.90 g of liquid monomer. The cement dough was shaped into flat cylinders with diameter and height of 6 mm and 2 mm, respectively. Another cement of the same shape without mixing vancomycin was prepared as the negative control. All manufactured cements were sterilized with ethylene oxide gas and stored at room temperature. Each cement was placed on Mueller Hinton agar plate lawned with standard MRSA strain. Standard vancomycin disk and gentamicin disk were placed together. After 24 hours, the diameter of inhibition zone was measured, and if the diameter was less than 15 mm, vancomycin-impregnated cement was regarded as a loss of antimicrobial activity. The study was repeated every 2 weeks until vancomycin-impregnated cements lost their antimicrobial activity. Results: Vancomycin-impregnated cement stored for a duration of 16 weeks created a 14 mm inhibition zone, while vancomycin disk created a 15 mm inhibition zone. Vancomycin-impregnated cement stored for a duration of 17 weeks created 7 mm and 9 mm inhibition zones, while vancomycin disk created 16 mm and 15 mm inhibition zones, respectively. Conclusion: We found a decrease of antimicrobial activity in vancomycin-impregnated cements after 16 weeks. After 17 weeks, they showed definite loss of antimicrobial activity. Therefore, we recommend not using vancomycin-impregnated cement spacers that has been stored for more than 16 weeks at room temperature.

GC-MS를 이용한 석유제품 중의 식별제 분석 (Determination of fuel marker in petroleum products using GC-MS)

  • 연주민;도진우;임의순;이정민
    • 한국응용과학기술학회지
    • /
    • 제35권4호
    • /
    • pp.1073-1080
    • /
    • 2018
  • 연료유로 사용되는 석유제품은 각각의 품질기준, 등급, 사용용도에 따라 여러 종류가 있다. 국가별로 유류에 세금을 부과하는 정도에 따라 동일한 석유제품이라 하더라도 가격차이가 발생한다. 가격이 저렴한 비과세의 석유제품을 상대적으로 고가인 수송용 연료에 불법적으로 혼합하는 행위로 인하여 탈세, 환경오염, 차량고장 등의 문제가 발생한다. 이러한 석유제품간 불법 혼합을 방지하기 위해 특정 석유제품에 미량의 식별제(Marker)를 법적으로 첨가하고 있다. 국내에서는 가정용 및 상업용 연료로 사용되는 등유를 자동차용 경유에 불법적으로 혼합하는 행위를 방지하기 위하여 식별제를 도입하여 사용하고 있으며, UV-Vis 분광광도계나 HPLC를 이용하여 식별제 함량을 정량적으로 분석하고 있다. 본 연구에서는 기존에 식별제 함량 분석을 위해 발색제를 첨가하거나 시료를 전처리하는 조작없이 GC-MS로 석유제품에 첨가된 식별제를 정성적 및 정량적으로 분석하는 방법을 개발하였다.

뿜어붙임멤브레인의 방수성능 및 염수저항성의 기초평가 (A preliminary study of watertightness and salt water resistance of spray-applied membrane)

  • 최순욱;강태호;장수호;이철호;김진태;최명식
    • 한국터널지하공간학회 논문집
    • /
    • 제19권2호
    • /
    • pp.283-299
    • /
    • 2017
  • 터널의 누수는 콘크리트 라이닝과 같은 구조물의 장기 내구성을 저하시키는 원인이 된다. 내구성 저하 원인은 염화물, 황산염, 물, 가스 등 지하수에 포함되어 있는 여러 가지 물질이 될 수 있다. 본 연구에서는 터널의 지보재로서 또는 방수재로서 사용되는 뿜어붙임멤브레인의 방수성능과 염수에 대한 저항성을 파악하기 위한 기초 시험을 수행하였다. 그 결과, 일부 시험체에서 물의 침투가 발생할 수 있는 것을 파악하였고 그 원인이 액상폴리머와 분말재료의 혼합에 의해 생기는 내부공극과 수압에 의해 내부공극이 연결되어 발생하는 것임을 알 수 있었다. 그리고 증류수와 염수에 침지된 시험체에 대한 인장강도시험을 통해서 인장강도가 기건상태에 비해 절반 이하로 감소될 수 있음을 확인하였다. 또한 신장률은 염수보다 증류수에서 신장률이 더 커지는 결과가 나타났다. 그러나 이 결과는 추가적인 조사가 필요할 것으로 판단된다.

간이이동법에 의한 폐아스콘 재생시 대기오염물의 배출분석에 대한 실험적 연구 (A Pilot Study on Emission Analysis of Air Pollutants Produced from Portable Recycling of Asphalt Concrete)

  • 이병규;김행아;정의량;;채포기;박경원
    • 한국환경과학회지
    • /
    • 제16권3호
    • /
    • pp.385-392
    • /
    • 2007
  • Currently, portable equipment for recycling of waste asphalt concrete (ASCON) has been used. However, any air pollution control devices are not attached in the simple portable one. Thus, a lot of air pollutants have been produced from recycling processes of waste ASCON which resulted from aging of paved roads or repavement of roads. This study deals with a preliminary result of concentration analysis of air pollutants obtained from a pilot and a real recycling processes of waste ASCON using simple portable recycling equipment. Air pollutants were taken from 4 steps of the pilot recycling process including an initial heating by liquid petroleum gas (LPG), intermediate heating and melting (H&M) process, final H&M process, and pavement processes using recycled ASCON at the recycling site. Also, air pollutants were taken front 4 steps of the real recycling processes including an initial H&M, final H&M and mixing, loading of recycled ASCON to dump trucks, and at the recycling site after leaving the loaded dump trucks for real pavement sites. The air pollutants measured in this study include volatile organic compounds (VOCs), aldehydes, particulate matter (PM: PM1, PM2.5, PM7, PM10, TSP (total suspended particulate)). The identified concentrations of VOCs increased with increasing time or degree for H&M of waste ASCON. In particular, very high concentrations of the VOCs at the status of complete melting, which is exposed to the air, of the waste ASCON just before paving tv the recycled ASCON at the recycling site. Also, considerable amount of VOCs were identified from the recycling equipment after the dump trucks leaded by recycled ASCON leaved the recycling site for the pavement sites. The relative level of formaldehyde exceeded 80% of the aldehydes Identified in the recycling processes. This is because the waste ASCON is exposed to direct flame of LPG during H&M processes. The PM concentrations measured in the winter recycling processes, such as the loading and rotation processes of waste ASCON into/in the recycling equipment for H&M, were much higher than those in the summer ones. In particular, the concentrations of coarse particles such as PM7 and PM10 during the winter recycling were very high as compared those during the summer one.

초미세기포 water jet을 이용한 도로 시설물 분진 제거 효율 평가 (Evaluation of Dust Removal Efficiency on Roadway Structures Using Ultrafine Bubble Water Jet)

  • 김현진;박일건
    • 청정기술
    • /
    • 제27권1호
    • /
    • pp.39-46
    • /
    • 2021
  • 4 HP, 80 LPM 급 초미세기포수 발생장치를 탑재한 도로 구조물 세척차량을 이용하여 도시 내 아파트 단지 주변 차량 통행이 많은 터널 내 콘크리트 표면과 타일 벽면을 세척하였다. 초미세기포 생성은 대기 중 공기를 2 ~ 3 LPM 으로 기액혼합 자흡펌프로 가압된 공기를 임펠러 회전력을 이용하여 마이크로 크기의 미세기포(fine-bubble)를 생성한다. 생성된 기포를 다단충돌판과 회전 노즐을 통과하면서 평균 직경 크기는 164.5 nm, 6.81 × 107 particles mL-1의 초미세기포(ultrafine bubble)를 생산하였다. 생산된 초미세기포를 함유한 세척수는 압력 150 bar, 토출량 30 LPM 으로 도로 구조물 표면에 흡착된 분진을 고압세척 분사하여 제거하였다. 분석실험은 세척 전과 후로 구분하여 표면에 흡착한 분진을 ISO 8502-3의 표면 오염 측정방법을 적용하였으며, 테이프 흡착으로 분진 입자를 채취하였다. 수집된 테이프는 중량법과 소프트웨어 ImageJ를 적용하여 분진의 무게와 입자 개수에 대한 제거율을 산정하였다. 실험 결과, 타일 벽면 표면에 흡착된 분진 입자 개수는 세척 전과 후로 각각 3,063 ± 218 particles mL-1, 20 ± 5 particles mL-1, 중량은 580 ± 82 mg, 13 ± 4 mg 으로 나타났다. 콘크리트 구조물 표면에서의 입자개수는 세척 전과 후로 각각 8,105 ± 1,738 particles mL-1, 39 ± 6 particles mL-1이었으며, 중량은 1,448 ± 190 mg, 118 ± 32 mg으로 나타났다.