• Title/Summary/Keyword: gas temperature distribution

Search Result 737, Processing Time 0.034 seconds

A Study on the Optimal Process Parameters for Recycling of Electric Arc Furnace Dust (EAFD) by Rotary Kiln (Rotary Kiln에 의한 전기로 제강분진(EAFD)의 재활용을 위한 최적의 공정변수에 관한 연구)

  • Jae-hong Yoon;Chi-hyun Yoon;Myoung-won Lee
    • Resources Recycling
    • /
    • v.33 no.4
    • /
    • pp.47-61
    • /
    • 2024
  • As a recycling technology for recovering zinc contained in large amounts in electric arc furnace dust (EAFD), the most commercialized technology in the world is the Wealz Kiln Process. The Wealz Kiln Process is a process in which components such as Zn and Pb in EAFD are reduced/volatile (endothermic reaction) in high-temperature Kiln and then re-oxidized (exothermic reaction) in the gas phase and recovered in the form of Crude zinc oxide (60wt%Zn) in the Bag Filter installed at the rear end of Kiln. In this study, an experimental Wealz kiln was produced to investigate the optimal process variable value for practical application to the recycling process of large-scale kiln on a commercial scale. Additionally, Pellets containing EAFD, reducing agents, and limestone were continuously loaded into Kiln, and the amount of input, heating temperature, and residence time were examined to obtain the optimal crude zinc oxide recovery rate. In addition, the optimal manufacturing conditions of Pellets (drum tilt angle, moisture addition, mixing time, etc.) were also investigated. In addition, referring to the SiO2-CaO-FeO ternary system diagram, the formation behavior of a low melting point compound, a reaction product inside Kiln according to the change in the basicity of Pellet, and the reactivity (adhesion) with the castable constructed on the inner wall of Kiln were investigated. In addition, in order to quantitatively investigate the possibility of using anthracite as a substitute for Coke, a reducing agent, changes in the temperature distribution inside Kiln, where oxidation/reduction reactions occur due to an increase in the amount of anthracite, the quality of Crude zinc oxide, and the behavior of tar in anthracite were also investigated.

Effect of Temperature and Gas Permeability of Functional Packing Films on Storability of Fresh-cut Salicornia herbacea Classified by Size (저장온도와 기능성 필름의 기체 투과도가 다양한 크기의 퉁퉁마디 신선편이의 저장성에 미치는 영향)

  • Baek, Jun Pill;Lee, Han Jong;Choi, In-Lee;Jung, Hyun Jin;Son, Jin Sung;Kim, Il Seop;Jeong, Cheon Soon;Kang, Ho-Min
    • Journal of Bio-Environment Control
    • /
    • v.22 no.2
    • /
    • pp.175-181
    • /
    • 2013
  • These studies were identified the effect of four types of non-perforated breathable (NPB) packing film and three sizes on storage ability of fresh-cut for ready to eat packaging at $5^{\circ}C$ for 25 days and $10^{\circ}C$ for 15 days storage in Salicornia herbacea. The fresh weight loss was less than 2% in every films at $5^{\circ}C$ condition after 25 days storage, and the $10^{\circ}C$ also had same result on 15 days storage except 100,000 cc NPB film. Compare with storage after 15 days, storage condition at $5^{\circ}C$ had shown better result under the 1% fresh weight loss rate. The 5,000 cc and $5^{\circ}C$ condition had been shown the characteristics of MA packaging in carbon dioxide and oxygen concentrations. The ethylene concentration in vacuum film was higher 10 to 100 times than in NPB film treatments during storage. But ethylene concentration was not statistically significant differences among size treatments. Every conditions had been measured the anti-oxidant activity by DPPH method after storage at $5^{\circ}C$ for 25 days and $10^{\circ}C$ for 15 days. S. herbacea at $5^{\circ}C$ had been more than twice of activity compare with that at $10^{\circ}C$. 100,000 cc NPB film had been higher contents of anti-oxidant activity at $5^{\circ}C$ and $10^{\circ}C$. As the fresh-cut sizes, 3 cm and 5 cm sizes had changed depending on film types but 10 cm were not effected by the film types in the DPPH activity. When panel test had been tried to measure the visual quality and off-flavor after storage, $5^{\circ}C$ with a filme of 5,000 cc treatment had established higher value than other treated conditions. As these results, it's may be suggested that the $5^{\circ}C$ with 5,000 cc non-perforated breathable film for MA storage in Salicornia herbacea at fresh cut distribution system. Fresh cut size 10 cm with 100,000 cc NPB film also had the good quality for 15 dyas storage at $10^{\circ}C$, and this result can be applied for short term distribution system in Korea.

Geochemical Studies of Geothermal Waters in Yusung Geotheraml Area (유성 지역 지열수의 지구화학적 특성 연구)

  • 김건영;고용권;김천수;배대석;박맹언
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.7 no.1
    • /
    • pp.32-46
    • /
    • 2000
  • Hydrogeochemical and isotope ($\delta$$^{18}$ O, $\delta$D, $^3$H, $\delta$$^{13}$ C, $\delta$$^{34}$ S, $^{87}$ Sr/$^{86}$ Sr) studies of various kinds of waters (thermal groundwater, deep groundwater, shallow groundwater, and surface water) from the Yusung area were carried out in order to elucidate their geochemical characteristics such as distribution and behaviour of major/minor elements, geochemical evolution, reservoir temperature, and water-rock interaction of the thermal groundwater. Thermal groundwater of the Yusung area is formed by heating at depth during deep circlulation of groundwater and is evolved into Na-HCO$_3$type water by hydrolysis of silicate minerals with calcite precipitation and mixing of shallow groundwater. High NO$_3$contents of many thermal and deep groundwater samples indicate that the thermal or deep groundwaters were mixed with contaminated shallow groundwater and/or surface water. $\delta$$^{18}$ O and $\delta$D are plotted around the global meteoric water line and there are no differences between the various types of water. Tritium contents of shallow groundwater, deep groundwater and thermal groundwater are quite different, but show that the thermal groundwater was mixed with surface water and/or shallow groundwater during uprising to surface after being heated at depths. $\delta$$^{13}$ C values of all water samples are very low (average -16.3$\textperthousand$%o). Such low $\delta$$^{13}$ C values indicate that the source of carbon is organic material and all waters from the Yusung area were affected by $CO_2$ gas originated from near surface environment. $\delta$$^{34}$ S values show mixing properties of thermal groundwater and shallow groundwater. Based on $^{87}$ Sr/$^{86}$ Sr values, Ca is thought to be originated from the dissolution of plagioclase. Reservoir temperature at depth is estimated to be 100~1$25^{\circ}C$ by calculation of equilibrium method of multiphase system. Therefore, the thermal groundwaters from the Yusung area were formed by heating at depths and evolved by water-rock interaction and mixing with shallow groundwater.

  • PDF

Proficiency Testing for the Gas-chromatographic Analysis of Procymidone, Chlorpyrifos and Metolachlor Residues in Soil (가스크로마토그래피를 이용한 토양 중 프로사이미돈과 클로르피리포스, 메톨라클로르의 잔류분석 숙련도시험)

  • Kim, Chan-Sub;Son, Kyeong-Ae;Gil, Geun-Hwan;Kim, Jin-Bae;Hong, Su-Myeong;Kwon, Hye-Young
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.2
    • /
    • pp.94-106
    • /
    • 2013
  • The proficiency testing for the residue laboratories of pesticide registration was conducted in order to improve the reliability and the ability for pesticide residue analysis. On October 2011 the testing was carried out using the soil collected and kept as the moistened state for five years, which is expected to very low residue levels of pesticides. The soil was fortified with chlorpyrifos, metolachlor and procymidone in a manner similar to prepare soil sample for indoor soil degradation test, and then sub-samples were prepared for the distribution to participants. Some of them were randomly selected for confirm of homogeneity and to ensure the stability of samples at room temperature. Samples were consisted of two soil treated as different levels, one of which was used to the assesment and another used to confirm. In addition, provide three standard solutions, respectively concentration of 10 mg/L, and untreated soil. Forty seven institutions submitted results. The medians of results were used as the assigned values for pesticide residues. Fitness for purpose standard deviation of proficiency test was calculated by applying 20% RSD as the coefficient of variation allowed in the soil residue test. Z-score was applied for evaluation of individual pesticides, and the average of the absolute value of the Z-score for the overall assessment of pesticides. Laboratories evaluated the absolute value of the Z-score less than 2 to fit the case of chlorpyrifos and procymidone were 44, metolachlor 40.

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.

A study on inspection methods for waste treatment facilities(I): Derivation of impact factor and mass·energy balance in waste treatment facilities (폐기물처리시설의 세부검사방법 마련연구(I): 공정별 주요인자 도출 및 물질·에너지수지 산정)

  • Pul-Eip Lee;Eunhye Kwon;Jun-Ik Son;Jun-Gu Kang;Taewan Jeon;Dong-Jin Lee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.1
    • /
    • pp.69-84
    • /
    • 2023
  • Despite the continuous installation and regular inspection of waste treatment facilities, complaints about excessive incineration and illegal dumping stench continue to occur at on-site treatment facilities. In addition, field surveys were conducted on the waste treatment facilities currently in operation (6 type) to understand the waste treatment process for each field, to grasp the main operating factors applied to the inspection. In addition, we calculated the material·energy balance for each main process and confirmed the proper operation of the waste disposal facility. As a result of the site survey, in the case of heat treatment facilities such as incineration, cement kilns, and incineration heat recovery facilities, the main factors are maintenance of the temperature of the incinerator required for incineration and treatment of the generated air pollutants, and in the case of landfill facilities Retaining wall stability, closed landfill leachate and emission control emerged as major factors. In the case of sterilization and crushing facilities, the most important factor is whether or not sterilization is possible (apobacterium inspection).In the case of food distribution waste treatment facilities, retention time and odor control during fermentation (digestion, decomposed) are major factors. Calculation results of material balance and energy resin for each waste treatment facility In the case of incineration facilities, it was confirmed that the amount of flooring materials generated is about 14 % and the amount of scattering materials is about 3 % of the amount of waste input, and that the facility is being operated properly. In addition, among foodwaste facilities, in the case of an anaerobic digestion facility, the amount of biogas generated relative to the amount of inflow is about 17 %, and the biogas conversion efficiency is about 81 %, in the case of composting facility, about 11 % composting of the inflow waste was produced, and it was comfirmend that all were properly operated. As a result, in order to improve the inspection method for waste treatment facilities, it is necessary not only to accumulate quantitative standards for detailed inspection methods, but also to collect operational data for one year at the time of regular inspections of each facility, Grasping the flow and judging whether or not the treatment facility is properly operated. It is then determined that the operation and management efficiency of the treatment facility will increase.

A study on inspection methods for waste treatment facilities(II): Derivation of problems and improvement direction in inspection methods (폐기물처리시설의 세부검사방법 마련연구(II): 세부검사방법 문제점도출 및 개선방향 설정)

  • Pul-Eip Lee;Eunhye Kwon;Jun-Ik Son;Jun-Gu Kang;Taewan Jeon;Dong-Jin Lee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.1
    • /
    • pp.85-100
    • /
    • 2023
  • In this study, in order to improve the installation periodical inspection method of waste treatment facilities, we conducted on-site surveys of waste treatment facilities classified into six fields, grasped the problems of inspection methods, and made improvements accordingly. And revised the inspection method for waste treatment facilities. As a result, in the field of incineration and incineration heat recovery, inspection methods such as total temperature measurement and one-year TMS data comparison using a thermal imaging camera were established. And for the safety of the inspected person, it was applied so that the waste can be replaced with a document without opening it. In the case of landfill facilities, the details regarding the use of video information processing equipment and the management of facilities covering the upper part of the landfill facility are presented in the law, but the items that do not have a inspection methods were applied to the inspection method. In the case of Food Waste Treatment Facility, inspection methods were put in place to ensure compliance with standards for foul-smelling fish in odor control, a major cause of complaints. As a result, 10 out of 18 improvement proposals were reflected in the incineration and sterilization grinding, cement kiln, and incineration heat recovery facilities, and 11 out of 12 improvement proposals were reflected in the landfill facility. In the case of food distribution waste treatment facilities, 10 out of 12 improvement proposals were reflected, and a total of 31 inspection methods were improved.