• 제목/요약/키워드: gas flow meter

검색결과 116건 처리시간 0.138초

헬리컬 코일형 가스냉각기 내 CO2의 냉각 열전달 특성 (Cooling Heat Transfer Characteristics of CO2 in Helical Coil Type Gas Coolers)

  • 손창효;전민주;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권6호
    • /
    • pp.699-706
    • /
    • 2007
  • The cooling heat transfer coefficient and pressure drop of $CO_2$(R-744) in helical coil copper tubes were investigated experimentally The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter. a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube of 2.45 and 4.55mm inner diameter The refrigerant mass fluxes were varied from 200 to $600 [kg/m^2s]$ and the inlet pressures of 9as cooler were 7.5 to 10.0 [MPa]. The heat transfer coefficients of $CO_2$ in helical coil tubes increase with the increase of mass flux and gas cooling pressure of $CO_2$. The pressure drop of $CO_2$ in the gas cooler shows a relatively food agreement with those Predicted by Ito's correlation developed for single-phase in helical coil tubes. Though a few correlation available with the data. the local heat transfer coefficient of $CO_2$ agrees well with those presented by Pitla et al. among the predictions. However at the region near pseudo-critical temperature. the experiment data indicate higher values than the Pitla et al. correlation.

가솔린 엔진의 비정상 상태에 대한 Map 구성과 공기 및 연료 모델 개선 (Construction of Map for Transient Condition of a Sl Engine and Refinement of Intake Air Model & Fuel Model)

  • 심연섭;강태성;강승표;고상근
    • 한국자동차공학회논문집
    • /
    • 제10권5호
    • /
    • pp.1-8
    • /
    • 2002
  • For gasoline engines, a three-way catalytic converter that has the maximum efficiency at stoichiometric air/fuel ratio is used to clean up the exhaust gas. So a precise air/fuel ratio control is necessary to maximize the catalytic conversion efficiency, For a transient condition, a fred-forward air/fuel ratio control method that estimates the air mass inducted into a cylinder is being used. In this study, a fuel injection map that makes an accurate air/fuel ratio control possible was constructed for the very same transient condition. For the same condition above, intake air model and fuel model were refined so that fuel injection values based on air mass through a throttle valve and intake manifold pressure are equal to the map values.

터보형 원판형 드래그펌프의 배기특성에 관한 실험적 연구 (An Experimental Study on the Pumping Performance of the Turbo-Type Disk-Type Drag Pump)

  • 황영규;허중식;권명근;이승재
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.577-580
    • /
    • 2002
  • In this paper, the pumping performance of the disk-type drag pump which works in the outlet pressure range from 4 to 0.001 Torr is studied experimentally. The pumping characteristics of various drag pumps are performed. The inlet pressures are measured for various outlet pressures of the test pump. The flow-meter method is adopted to calculate the pumping speed. Compression ratios and pumping speeds for the nitrogen gas are measured. The present experimental data show the leak-limited value of the compression ratio in the molecular transition region. The rotational speed of the pump is 24,000rpm. The inlet pressures are measured for various outlet pressures of the test pump. The ultimate Pressures for zero throughput are measured for three-stage, two-stage and single-stage disk-type, respectively.

  • PDF

LPG 충전기용 온도 보정 시스템 개발 (A Temperature Compensating System for LPG Dispenser)

  • 이상훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3162-3164
    • /
    • 1999
  • In this paper, a temperature compensating system(TCS) for LPG dispenser has been developed. A TCS includes a processor(80C196) with an AID converter. I/O port(82C55) and 6-digit vacuum fluorescent display. Based on encoding signals from the gas flow meter, different calibration values from each apparatus and temperature compensating values from the temperature sensor, the TCS controls the LPG dispensing quantity with switching on or off the solenoid valves. The temperature compensation is performed with analog-to-digital conversion of the temperature sensor. The resolution of temperature compensation is nearly $0.5^{\circ}C$ using 10-bit ADC. The field test of the TCS shows the exact temperature compensation.

  • PDF

가솔린 직접분사식 압축착화 엔진의 가능한 운전영역에 관한 기초실험 연구 (A Basic Experimental Study on Potential Operating Range in Gasoline Direct-Injection Compression Ignition (GDICI) Engine)

  • 차준표;윤성준;이석훤;박성욱
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2013년도 제46회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.33-35
    • /
    • 2013
  • The present work is an experimental investigation on potential operating range using directly injected gasoline fuel in a single-cylinder compression ignition (CI) engine. The objectives of present study were to apply auto-ignited combustion to gasoline fuel and to evaluate potential operating range. In order to auto-ignite gasoline fuel in CI engine, the fuel direct-injection system and the intake air system were modified that a flow rate and temperature of intake air were regulated. The heat-release rate (HRR), net indicated mean effective pressure (IMEP), start of combustion (SOC), and combustion duration were derived from in-cylinder pressure data in a test engine, which has 373.33cc displacement volume and 17.8 compression ratio. The exhaust emission characteristics were obtained emission gas analyzer and smoke meter on the exhaust line system.

  • PDF

석탄 화력발전소에서 발생되는 석탄회의 수분함유량 및 온도에 따른 비저항성 특성 연구 (A Study of Fly Ash Resistivity Characteristics Generated from the Coal Fired Power Plant as a Function of Water Concentration and Temperature)

  • 구재현;이정언;이재근
    • 대한기계학회논문집B
    • /
    • 제24권4호
    • /
    • pp.526-532
    • /
    • 2000
  • Recent studies have been directed toward obtaining a better understanding of the application of electrostatic precipitators to collect fly ash particles produced in a coal-fired power plant. Electrical resistivity can be described as the resistance of the collected dust layer to the flow of electrical current and is an important property for the collection efficiency in the electrostatic precipitator. In this paper, fly ash resistivity as a function of temperature up to $450^{\circ}C$ has been experimentally investigated using the resistivity meter consisted of the movable electrode, dust cup, and furnace. Resistivity was found to increase with increased temperature up to $200^{\circ}C$ due to the reduction of water concentration and then gradually decrease with increased temperature due to the activation of electrons. As the resistivity of fly ash in the flue gas temperature of $150^{\circ}C$ was measured >$10^{10}$ ohm cm, the efficiency of fly ash removal in the electrostatic precipitator might be expected to be low due to back-corona phenomenon. Flue gas conditioning in the electrostatic precipitator to reduce the resistivity of fly ash as required.

코리올리 질량유량계를 이용한 액화석유가스(LPG) 정량 측정 방법 연구 (A Study on Liquified Petroleum Gas(LPG) Fuel Quantitative Method using Coriolis Mass Flowmeter)

  • 박태성;성상래;임의순;이정민;이명식;강형규
    • 한국가스학회지
    • /
    • 제22권6호
    • /
    • pp.109-122
    • /
    • 2018
  • 국내 LPG 미터는 "계량에 관한 법률"에 의거 LPG 정량에 대한 검사가 실시되고 있다. LPG 미터는 "계량에 관한 법률 시행령"에 따라 3년마다 재검정이 실시된다. 검사 시 최대허용오차는 ${\pm}1.0%$ 이내, 사용오차는 ${\pm}1.5%$ 이내이다. 정량 측정 시에는 밀도부액계, 저울, 압력용기를 사용한다. LPG는 온도와 압력에 따라 부피 변화의 정도가 매우 심하다. 현행 정량 측정 방법은 LPG의 부피를 구하기 위해 온도 및 압력, 밀도를 측정해야 하며, 이에 따른 장비들이 필요하다. 반면에 코리올리 질량유량계는 질량유량, 밀도, 온도를 동시에 측정하며, 컴퓨터 프로그램을 사용하여 측정값을 필요한 값으로 변환 및 산출 할 수 있어, 산업현장에서 널리 적용되고 있다. 본 연구에서는 LPG 정량 측정에 대한 기초연구로서, 코리올리 질량유량계를 이용하여 LPG 충전기에서 나온 LPG 부피를 측정했다. 또한, 기존 LPG 충전기 검사방법과의 비교를 통해 코리올리 질량유량계를 이용한 LPG 충전기 검사도 가능하다는 결론을 얻었다.

Hydroxy Polyimide 막의 제조와 이산화탄소 투과 특성 (Prepration of Hydoxy Polyimde Membranes and Their Carbon Dioxide Permeation Property)

  • 우승문;최종진;남상용
    • 멤브레인
    • /
    • 제22권2호
    • /
    • pp.128-134
    • /
    • 2012
  • 본 연구에서는 hydroxy polyimide (HPI)로 용매 증발법에 의해 제조가 되었다. 비다공성막의 기체투과성능측정 결과로써, $CO_2$ 투과도는 약 85 Barrer이고, $CO_2/N_2$선택도는 23으로 측정되었다. 고분자, 용매, 비용매-첨가제의 3성분계 시스템을 도입하여 평막과 중공사막을 제조하였고, 모폴로지와 기체투과성능을 전계방출형전자주사현미경과 버블플로우메타로 측정하였다. 평막과 중공사막에서 $CO_2$투과도와 $CO_2/N_2$ 선택도는 각각 18.28 GPU, 70 GPU를 6.72, 8.63으로 나타남을 확인하였다. 중공사막이 평막보다 기체투과특성이 우수하다는 것을 확인하였다.

A study of improving filtration efficiency through SiC whisker synthesis on carbon felt by CVD VS method

  • 김광주;최두진
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.150-150
    • /
    • 2016
  • Mankind is enjoying a great convenience of their life by the rapid growth of secondary industry since the Industrial Revolution and it is possible due to the invention of huge power such as engine. The automobile which plays the important role of industrial development and human movement is powered by the Engine Module, and especially Diesel engine is widely used because of mechanical durability and energy efficiency. The main work mechanism of the Diesel engine is composed of inhalation of the organic material (coal, oil, etc.), combustion, explosion and exhaust Cycle process then the carbon compound emissions during the last exhaust process are essential which is known as the major causes of air pollution issues in recent years. In particular, COx, called carbon oxide compound which is composed of a very small size of the particles from several ten to hundred nano meter and they exist as a suspension in the atmosphere. These Diesel particles can be accumulated at the respiratory organs and cause many serious diseases. In order to compensate for the weak point of such a Diesel Engine, the DPF(Diesel Particulate Filter) post-cleaning equipment has been used and it mainly consists of ceramic materials(SiC, Cordierite etc) because of the necessity for the engine system durability on the exposure of high temperature, high pressure and chemical harsh environmental. Ceramic Material filter, but it remains a lot of problems yet, such as limitations of collecting very small particles below micro size, high cost due to difficulties of manufacturing process and low fuel consumption efficiency due to back pressure increase by the small pore structure. This study is to test the possibility of new structure by direct infiltration of SiC Whisker on Carbon felt as the next generation filter and this new filter is expected to improve the above various problems of the Ceramic DPF currently in use and reduction of the cost simultaneously. In this experiment, non-catalytic VS CVD (Vapor-Solid Chemical Vaporized Deposition) system was adopted to keep high mechanical properties of SiC and MTS (Methyl-Trichloro-Silane) gas used as source and H2 gas used as dilute gas. From this, the suitable whisker growth for high performance filter was observed depending on each deposition conditions change (input gas ratio, temperature, mass flow rate etc.).

  • PDF

An Experimental Study on Heat Transfer and Pressure Drop Characteristics of Carbon Dioxide During Gas Cooling Process in a Hellically Coiled Tube

  • Oh, Hoo-Kyu;Son, Chang-Hyo;Yu, Tae-Geun;Kim, Dae-Hui
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권3호
    • /
    • pp.263-271
    • /
    • 2007
  • The heat transfer coefficient and pressure drop during 9as cooling process of $CO_2$ (R744) in a helically coiled copper tube with the inner diameter of 4.55 mm and outer diameter of 6.35 mm were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump. a mass flow meter a pre-heater and a helically coiled type gas cooler (test section). The refrigerant mass fluxes are varied from 200 to $800kg/m^2s$ and the inlet pressures of gas cooler are 7.5 to 10.0 MPa. The heat transfer coefficients of $CO_2$ in a helically coiled tube are higher than those in a horizontal tube. The Pressure drop of $CO_2$ in the gas cooler shows a relatively good agreement with those predicted by Ito's correlation developed for single-phase in a helically coiled tube. The local heat transfer coefficient of $CO_2$ agrees well with the correlation by Pitla et al. However. at the region near pseudo-critical temperature. the experiments indicate higher values than the Pitla et al correlation. Therefore, various experiments in helically coiled tubes have to be conducted and it is necessary to develop the reliable and accurate prediction determining the heat transfer and pressure drop of $CO_2$ in a helically coiled tube.