• 제목/요약/키워드: gas facility

검색결과 760건 처리시간 0.027초

외열킬른형 열분해용융시설의 N2O 배출계수 개발 (The Development of N2O Emission Factor at Killn Type Pyrolysis Melting Facility)

  • 윤현기;이대겸;조창상;강성민;윤영중;전영재;전의찬
    • 한국기후변화학회지
    • /
    • 제8권3호
    • /
    • pp.231-237
    • /
    • 2017
  • In this study, the $N_2O$ emission factor of the facility was developed by measuring the kiln type pyrolysis melting facility. This used PAS (Photoacoustic Spectroscopy) method and measured the $N_2O$ emission concentration. From March 2016 to April 2016, it was measured over a total of two times and $N_2O$ concentrations were measured continuously for 24 hours using a 24 hour continuous measuring instrument (LSE-4405). The measured $N_2O$ emission concentration of the pyrolysis melting facility was 0.263 ppm on average and the emission concentration distribution in the range of 0.013~0.733 ppm was obtained. Therefore, the $N_2O$ emission factor of the kiln-type pyrolysis melting facility was estimated to be $0.829gN_2O/ton$-Waste. As a result of comparing the $N_2O$ emission factor of the thermal kiln type pyrolysis melting facility and the previous study, previous studies were about 18 times higher. It is estimated that this is due to the difference of furnace temperature, oxygen concentration and denitrification facilities. It is considered that the study of the emission factor of pyrolysis melting facility is an important factor in improving the credibility of greenhouse gas inventory in waste incineration sector.

국내 대학 실험실 독성가스 시설의 안전관리를 위한 표준 체크리스트 개발 (Development of Standard Checklist for Safety Management of Toxic Gas facility in Domestic University Laboratory)

  • 이성진;김병덕;하동명
    • 한국가스학회지
    • /
    • 제19권6호
    • /
    • pp.92-98
    • /
    • 2015
  • 독성가스는 고압가스안전관리법에 의해 관리된다. 독성가스는 "고압가스안전관리법에서 규정한, 31종의 가스와 $LC_{50}$이 5000 ppm 이하인 가스"이다. 전자산업의 발달에 따라 우리나라 독성가스 사용량은 폭발적으로 증가하였다. 이에 국내 대학교 실험실의 독성가스 관련 연구 수요도 함께 증가해 왔다. 그러나 국내 실험실 독성가스 안전관리와 관련한 연구는 전무한 상태이다. 본 연구에서는 국내 대학 실험실의 실태조사를 통해 독성가스 안전관리에 있어서의 약점들을 파악하였다. 이 같은 약점을 극복하기 위해 독성가스 안전관리 방안을 제시하였다. 또한 제시된 방안에 따라 독성가스 시설이 안전하게 관리되는지를 확인하고, 이를 통한 개선을 위해 표준 체크리스트를 개발하였다. 이 연구 결과는 국내 대학 실험실에서 독성가스 시설의 안전관리를 강화할 것이며, 이를 모든 실험실에 대한 안전 지침으로 제공한다.

Application of Cathodic Protection on Metallic Structure in Extremely Acidic Fluids

  • Chang, H.Y.;Yoo, Y.R.;Jin, T.E.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • 제4권4호
    • /
    • pp.140-146
    • /
    • 2005
  • Fossil fired power plant produces the electric energy by using a thermal energy by the combustion of fossil fuels as like oil, gas and coal. The exhausted flue gas by the combustion of oil etc. contains usually many contaminated species, and especially sulfur-content has been controlled strictly and then FGD (Flue Gas Desulfurization) facility should be installed in every fossil fired power plant. To minimize the content of contaminations in final exhaust gas, high corrosive environment including sulfuric acid (it was formed during the process which $SO_2$ gas combined with $Mg(OH)_2$ solution) can be formed in cooling zone of FGD facility and severe corrosion damage is reported in this zone. These conditions are formed when duct materials are immersed in fluid that flows on the duct floors or when exhausted gas is condensed into thin layered medium and contacts with materials of the duct walls and roofs. These environments make troublesome corrosion and air pollution problems that are occurred from the leakage of those ducts. The frequent shut down and repairing works of the FGD systems also demand costs and low efficiencies of those facilities. In general, high corrosion resistant materials have been used to solve this problem. However, corrosion problems have severely occurred in a cooling zone even though high corrosion resistant materials were used. In this work, a new technology has been proposed to solve the corrosion problem in the cooling zone of FGD facility. This electrochemical protection system contains cathodic protection method and protection by coating film, and remote monitoring-control system.

가스온수가열기의 용량에 따른 에너지효율성 비교 연구 (A Comparative Study on the Energy Efficiency due to the Capacity of Gas Boiler)

  • 김성중;우인성
    • 대한안전경영과학회지
    • /
    • 제17권2호
    • /
    • pp.229-234
    • /
    • 2015
  • Depending on the living styles, the types of energy consumed by households have changed, and the consumption has increased rapidly. Consequently, those have led to environmental issues, such as exhaustion of energy and the climate changes. As one of solutions to such issues, energy efficiency can be approached. Therefore, in this study, the gas water heater(115S type Rheem products) that made in Germany and obtain hot water using gas as a heat source is selected. a $1.0m^3$ water tank with a 6kW electronic heater is installed and a water temperature and pressure is maintain constantly also thermometer is injected. Two of gas meter, one of pressure regulator and three of time measurement devices are installed in a combustion facility and fuelling facility with a magnet valve so it can observe and record combustion reactions. Quantity of hot water that heated by boiler is recorded using a quantity measurement tank, and have been heated by the boiler have been to record and measure the amount and utilized the data acquired through measurement of all factors that are applied to acquire hot water in order to calculate the use rate of final energy. In conclusion, this researcher drew the economic strong points of the hot water generated by gas.

Long-Term Experiments for Demonstrating Durability of a Concrete Barrier and Gas Generation in a Low-and Intermediate-Level Waste Disposal Facility

  • Kang, Myunggoo;Seo, Myunghwan;Kim, Soo-Gin;Kwon, Ki-Jung;Jung, Haeryong
    • 방사성폐기물학회지
    • /
    • 제19권2호
    • /
    • pp.267-270
    • /
    • 2021
  • Long-term experiments have been conducted on two important safety issues: long-term durability of a concrete barrier with the steel reinforcements and gas generation from low-and intermediate-level wastes in an underground research tunnel of a radioactive waste disposal facility. The gas generation and microbial communities were monitored from waste packages (200 L and 320 L) containing simulated dry active wastes. In the concrete experiment, corrosion sensors were installed on the steel reinforcements which were embedded 10 cm below the surface of concrete in a concrete mock-up, and groundwater was fed into the mock-up at a pressure of 2.1 bars to accelerate groundwater infiltration. No clear evidence was observed with respect to corrosion initiation of the steel reinforcement for 4 years of operation. This is attributed to the high integrity and low hydraulic conductivity of the concrete. In the gas generation experiment, significant levels of gas generation were not measured for 4 years. These experiments are expected to be conducted for a period of more than 10 years.

수소운송설비 안전성 강화 방안 고찰 (A Study on the Safety Enhancement of Hydrogen Tube Trailer)

  • 박우일;김영훈;이인우;강승규
    • 한국가스학회지
    • /
    • 제26권6호
    • /
    • pp.59-64
    • /
    • 2022
  • 현재 수소운송설비는 2022년 10월 말 기준 787대가 운행 중이며, Type 1 이음매 없는 용기에 최대 200 bar의 압력으로 1회 최대 340 kg을 운송한다. 현재 안전관리체계 및 설비관리는 양호한 상태이나, 안전성 강화를 위해 제도 및 설비 구조개선이 필요한 실정이다. 이에 따라, 본 논문은 수소에너지 활성화 정책에 의해 수소운송설비 보급·운영의 확대 과정 중 지난 2021년 12월 28일 대전-당진간 고속도로에서 발생한 사고사례를 모사 및 해석을 진행하였으며, 사고 분석 및 해석 결과에 따라 수소운송설비의 안전성 향상 방안에 대해 제언하였다.

UHF이중대역법을 이용한 GISPD분석 (GISPD Analysis Using UHF Dual-Band Method)

  • 김광화;이상화;최재구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1860-1862
    • /
    • 2004
  • It is widely known that the ultra high frequency (UHF) method that detects the electromagnetic wave of the PD pulses in the gas insulated space is one of the most competitive methods for its high sensitivity. From the above point of view, this paper describes the characteristics of GIS PD signals measured with ultra wide band (UWB) GIS PD detecting system in which PD signals are detected into the dual UHF band. The UWB PD detection system consists of the UWB UHF coupler, the UWB low noise amplifier (LNA) and the oscilloscope. The dual bands for PD signals are 0.5-2GHz(full band) and 1-2GHz(high band). As results, it was found that the partial discharges of each defect have their own characteristic pattern and the ratio of High band to Full band increases with gas pressure.

  • PDF

소각설비에 대한 확률론적 환경위험성 평가 적용 (An Application of Probabilistic Environmental Risk Assessment for An Incineration Facility)

  • 김영제;장의종;안경수
    • 환경영향평가
    • /
    • 제13권1호
    • /
    • pp.1-8
    • /
    • 2004
  • A wide spectrum of risk assessments including qualitative and quantitative approaches and the analyses of its consequence were performed for an environmentally sensitive object such as incineration facility. To find out the major risk concerns, HAZOP(Hazard and Operability) were performed. Then, the frequency of hazardous gas release scenarios was calculated. Finally consequence analyses were performed for the gas release scenarios. On the basis of analyses through evaluation, a more innovative way for making a better control system or the enhancement of operation procedure was given. The results from these analyses would act as a substantial benefits for the incineration facility operator, and giving some measured information for the neighbors and the people involved.

유해화학물 취급 중소기업 시설 관리실태 현황 및 개선방안 (Case Study of Safety Management at Small Industry Handling Hazardous Chemicals)

  • 송은희;이동훈;조영호;곽동호;박교식
    • 한국가스학회지
    • /
    • 제21권4호
    • /
    • pp.21-29
    • /
    • 2017
  • 유해화학물을 취급하는 중소규모의 사업장에 대하여 시설을 세부점검하였으며 이를 정리하였다. 점검결과는 크게 공정, 저장소, 작업자 및 기타 사항으로 구분하여 현황 및 문제점을 정리하고 이에 대한 세부적인 개선방안을 제시하였다. 전반적으로 법규를 만족하기만 하면 된다는 인식하에 최소한의 요구조건만을 갖추어 놓고 있었으며 이에 대한 지속적인 관리가 미흡한 것으로 결론되었다.

헬륨을 이용한 열유속센서 검정방법의 실험적 연구 (An Experimental Study on Calibration Method of Heat Flux Sensor by using Helium Gas)

  • 양훈철;송철화;김무환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1219-1224
    • /
    • 2004
  • The objective of this study is to propose an experimental calibration facility in which a heat flux sensor can be calibrated under conductive condition by using helium gas. The heat flux calibration facility was designed, simulated and manufactured for use in a high heat transfer condition. It delivers heat fluxes up to a maximum of 35 KW $m^{-2}$. A copper block heated electrically with 3.5 KW power is designed to produce uniform temperature up to 600 K across its face. High heat fluxes are provided between hot plate and cold plate by 1 mm height helium filled gap. A cold plate is maintained around 300 K through pool boiling using a refrigerant and water-cooled heat exchanger. A simulation was conducted to verify the design of the main test section. To verify the performance of calibration facility, a heat flux sensor was examined. The measured heat fluxes were compared to the calculated one.

  • PDF