• Title/Summary/Keyword: gas combustion unit

Search Result 82, Processing Time 0.026 seconds

Estimation of heat release rate of liquid fuels by Oxygen consumption technique (산소 소모법에 의한 액체 연료의 열발생율 평가)

  • 한용식;김명배;최준석
    • Fire Science and Engineering
    • /
    • v.12 no.3
    • /
    • pp.31-37
    • /
    • 1998
  • The heat release rate of liquid fuels is estimated by oxygen consumption technique. This method is based on the generalization that the heat release rate of combustion per unit of oxygen consumed are approximately the same for most fuels commonly encountered in fires. The oxygen concentration is measured by analyzer of paramagnetic type. The concentrations of CO2 and CO gas are measured by analyzed of Infra-Rad type. Time delays of analyzers are ignored. Results acqired from measuring techniques of exhaust gas concentrations are compared with each other.

  • PDF

Comparative study of greenhouse gas emission from coastal and offshore gillnet and trap fisheries by field research (연근해 자망과 통발 어업의 온실가스 배출량 현장실측 연구)

  • LEE, Seok-Hyung;KIM, Hyunyoung;YANG, Yongsu;KANG, Da-Young
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.54 no.4
    • /
    • pp.315-323
    • /
    • 2018
  • Fossil fuel combustion during fishing activities is a major contributor to climate changes in the fishing industry. The Tier1 methodology calculation and on-site continuous measurements of the greenhouse gas were carried out through the use of fuel by the coastal and offshore gillnet (blue crabs and yellow croaker) and trap (small octopus and red snow crab) fishing boats in Korea. The emission comparison results showed that the field measurements are similar to or slightly higher than the Tier1 estimates for coastal gillnet and trap. In offshore gillnet and trap fisheries, Tier1 estimate of greenhouse gases was about $1,644-13,875kg\;CO_2/L$, which was more than the field measurement value. The $CO_2$ emissions factor based on the fuel usage was $2.49-3.2kg\;CO_2/L$ for coastal fisheries and $1.46-2.24kg\;CO_2/L$ for offshore fisheries. Furthermore, GHG emissions per unit catch and the ratio of field measurement and Tier1 emission estimate were investigated. Since the total catch of coastal fish was relatively small, the emission per unit catch in coastal fisheries was four to eight times larger. The results of this study could be used to determine the baseline data for responding to changes in fisheries environment and reducing greenhouse gas emission.

A Study on Combustion Experiments of Multi Type Air-Conditioner Outdoor Units by Large Scale Calorimeter (라지스케일 칼로리미터에 의한 멀티시스템형 에어컨실외기의 연소실험에 관한 연구)

  • Min, Se-Hong;Bae, Yeon-Jun
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.168-177
    • /
    • 2011
  • The combustion test for real box of AC outdoor unit has been performed in this study in order to estimate the fire hazard in multi-system type of AC outdoor unit which is currently used for commercial use. The result showed that in test, there was explosion inside of AC outdoor unit, and flame erupted and fire spread through upper side grill. And then this fire burnt the combustibles such as wires, electronic control board, heat exchange copper plate and plastics etc inside the unit, refrigerant gas pipe was burst due to fire, and accelerated the explosion and flame eruption to outside while the refrigerant was erupting. It is found in this test that the maximum heat release rate of AC outdoor unit is 5,830 kW, the maximum internal temperature measured with infrared camera and thermocouple is $1,201^{\circ}C$, maximum ambient temperature is $881^{\circ}C$, and flame rose higher than about 5 m. It is concluded that the fire in AC outdoor unit cause fire to combustibles around the unit, and may give big damage by generating the secondary fire. It is expected that the result obtained from the test on the real object may be applied to fire realization of AC outdoor unit and estimation of fire spreading to the combustibles around in the future computer simulation.

Production of Carbonized Rice Husk by a Cyclone Combustor(II) (사이클론 연소기를 이용한 탄화왕겨의 제조(II))

  • 김원태;노수영
    • Journal of Biosystems Engineering
    • /
    • v.24 no.6
    • /
    • pp.487-492
    • /
    • 1999
  • One of effective utilization method of rice husk is to utilize it as culture material by carbonizing the rice husk. As a second part of a series to investigate the effective and continuous production of carbonized rice husk by a cyclone combustor, a non-slagging vertical cyclone combustor without vortex collector pocket was introduced. Isothermal and mixed firing with LPG and rice husk were undertaken in order to characterize the system. Inert rice husk was used during the isothermal test to find mass of rice husk collected. It was impossible to ignite rice husk itself over the experimental conditions considered in this experiment. Cyclone combustor was operated at temperatures of 1,273~1,473K. Detailed combustion data were obtained from a pilot unit with the air flow rate of 70m$^3$/h and rice husk feed of 2kg. The equivalence ratio ranged from 0.66 to 3.48. The auxiliary gas flow rate was varied from 3.22 to 12.86$\ell$/min. The weight reduction, pH and particle size distribution of carbonized rice husk were measured to evaluate the quality of carbonized rice husk. An analysis of exhaust gas emission was conducted to characterize the combustor. The required carbonized rice husk could be obtained at equivalence ratio of 1.68~2.17, combustor temperature of 1,273~1,373K and auxiliary gas flow rate of 3.22~6.43$\ell$/min. A method to reduce CO emissions should be employed.

  • PDF

Design of a Swash Plate Type of Steam Expander for Waste Heat Recovery (폐열 회수용 사판식 스팀 팽창기 설계)

  • Kim, Hyun-Jae;Kim, Hyun-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.5
    • /
    • pp.313-320
    • /
    • 2011
  • For a steam Rankine cycle to recover waste heat from the exhaust gas of an Internal combustion engine, a swash plate type of expander as a power conversion unit has been designed. Numerical simulation has been carried out to estimate the performance of the designed expander. With the steam pressure and temperature of 35 bar and $300^{\circ}C$ at the expander inlet, respectively, the expander was estimated to produce the shaft power output of about 2.67 kW from the exhaust gas waste heat of 25.2 kW. The expander output increased almost linearly with the amount of exhaust gas waste heat in the range of from 5~40 kW, and the expander and Rankine cycle efficiencies showed gradual decreases in the ranges of 72.2%~69.5% and 10.8%~10.4%, respectively.

A Study on Detoxication of Coal Briquette by Additives (첨가제에 의한 연탄제독에 관한 연구)

  • Chang Tuwon;Young Sun Uh;Youn Soo Sohn
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.1
    • /
    • pp.118-125
    • /
    • 1986
  • A small scale combustion unit was built to evaluate the CO suppression effects by various chemical additives added to coal briquettes. Among the additives tested comprising various transition metal compounds with catalytic activities, natural minerals and oxidizing agents, the copper component has shown the best CO suppression effect, and in particular, copper oxide dispersed on porous supports such as ${\gamma}-Al_2O_3$ was most effective. For instance, 0.5% of copper added to coal briquettes in this way bas exhibited 1.4 % CO in the combustion gas at the ignition and beginning stage of combustion and 0.3 % CO at the final stage. The effects of calcium compounds on the fixation of sulfur in coal were also evaluated to reduce the contents of sulfur compounds in the combustion gases.

  • PDF

Heat Recovery Characteristics of the Exhaust Heat Recovery System with Heat Pipe Unit Attached to the Hot Air Heater in the Greenhouse (히트파이프를 이용한 온풍난방기 배기열회수 시스템의 열회수 특성)

  • Kang, K. C.;Kim, Y. J.;Ryou, Y. S.;Baek, Y.;Rhee, K. J.
    • Journal of Biosystems Engineering
    • /
    • v.26 no.5
    • /
    • pp.441-448
    • /
    • 2001
  • Hot air heater with light oil combustion is used as the most common heater for greenhouse heating in the winter season. However, exhaust gas heat discharged to atmosphere through chimney reaches up to 10~20% of total heat capacity of the oil burred. In order to recover the heat of this exhaust gas and to use for greenhouse heating, the heat pipe type exhaust heat recovery system was manufactured and tested in this experiment. The system consisted of a heat exchanger made of heat pipes, ø15.88${\times}$600mm located in the rectangular box of 675(L)${\times}$425(W)${\times}$370(H)mm, an air suction fan and air ducts. The number of heat pipe was 60, calculated considering the heat exchange amount between exhaust gas and air and heat transfer capacity of a heat pipe. The working fluid of heat pipe was acetone because acetone is known for its excellent heat transfer capacity. The system was attached to the exhaust gas path. According to the performance test it could recover 53,809 to 74,613kJ/h depending on the inlet air temperature of 12 to -12˚at air flow rate of 1.100㎥/h. The temperature of the exhaust gas left the heat exchanger dropped to 100$^{\circ}C$ from 270$^{\circ}C$ after the heat exchange between the suction air and the exhaust gas.

  • PDF

Characteristics of $CH_4$ Decomposition by Plasma (플라즈마 이용 메탄 분해 특성)

  • Kim, Kwan-Tae;Lee, Dae-Hoon;Cha, Min-Suk;Ryu, Jeong-In;Song, Young-Hoon
    • Journal of the Korean Society of Combustion
    • /
    • v.10 no.4
    • /
    • pp.24-32
    • /
    • 2005
  • Various types of plasma source applied in $CH_4$ decomposition process are compared. DBD by pulse and AC power, spark by pulse and AC power, rotating arc and hollow cathode plasma are chosen to be compared. The results show that $CH_4$ conversion per given unit power is relatively high in hollow cathode plasma and rotating arc that induces rather high temperature condition and that is why both thermal dehydration and plasma induced decomposition contribute for the overall process. In case of DBD wherein high temperature electron and low temperature gas molecule coexist, the process shows low conversion rate, for in rather low temperature condition the contribution of thermal dehydration is lowered. Selectivity of $C_2H_6$ and $C_2H_2$ is shown to be a good parameter of the relative contribution of plasma chemistry in the overall process. From the results we concluded that required condition of plasma source for a cost effective and high yield $CH_4$ decomposition is to have characteristics of both thermal plasma and non thermal plasma in which temperature is high above a certain threshold state for thermal dehydration and electron induced collision is maximized in the same breath.

  • PDF

Comparision of Heat Exchanging Performance Depending on Different Arrangement of Heat Exchanging Pipe (II) (열회수장치의 열교환 파이프배치형식별 열교환 성능 비교(II))

  • Suh, Won-Myung;Kang, Jong-Guk;Yoon, Yong-Cheol;Kim, Jung-Sub
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.281-285
    • /
    • 2001
  • This study was carried out to improve the performance of heat recovery device attached to exhaust gas flue connected to combustion chamber of greenhouse heating system. Three different units were prepared for the comparison of heat recovery performance; AB-type(control unit) is exactly the same with the typical one fabricated for previous study of analyzing heat recovery performance in greenhouse heating system, other two types(C-type and D-type) modified from the control unit are different in the aspects of airflow direction(U-turn airflow) and pipe arrangement. The results are summarized as follows; 1. In the case of Type-AB, when considering the initial cost and current electricity fee required for system operation, it is expected that one or two years at most would be enough to return the whole cost invested. 2. Type-C and Type-D, basically different with Type-AB in the aspect of airflow pattern, are not sensitive to the change of blower capacity with higher than $25\;m^{3}/min$. Therefore, heat recovery performance was not improved so significantly with the increment of blower capacity. This is assumed to be that air flow resistance in high air capacity reduces the heat exchange rate as well. Never the less, compared with control unit, resultant heat recovery rate in Type-C and Type-D were improved by about 5% and 13%, respectively. 3. Desirable blower capacity for these heat recovery units experimented are expected to be about $25\;m^{3}/min$, and at the proper blower capacity, U-turn airflow units showed better heat recovery performance than control unit. But, without regard to the type of heat recovery unit, it is recommended that comprehensive consideration of system's physical factors such as pipe arrangement density, unit pipe length and pipe thickness, etc., are required for the optimization of heat recovery system in the aspects of not only energy conservation but economic system design.

  • PDF

Development of stacks and power generation systems based on anode-supported SOFCs for intermediate temperature operation (연료극 지지체형 SOFC를 이용한 중.저온용 스택 및 발전시스템 개발)

  • Lee, Tae-hee;Choi, Jin-Hyeok;Park, Tae-Sung;Yoo, Young-Sung;Park, Jin-Woo
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1986-1991
    • /
    • 2007
  • KEPRI has studied anode-supported planar SOFCs and kW class stacks operated at intermediate temperature for development of a combined heat and power unit. A single cell composed of Ni-YSZ/FL/ScSZ/LSCF showed the maximum power density of 0.55 W/$cm^2$ at $650^{\circ}C$ and 1.8 W/$cm^2$ at $750^{\circ}C$. With 37 cells of 10${\times}10cm^2$ and stainless steel interconnects, a 1kW class SOFC stack was manufactured. When a 1kW class SOFC system was operated at $750^{\circ}C$ with city gas, it showed the power output of 1.3 kWe at 50 A. It also recuperated heat of 0.57-1.2 kWth according to the loaded current through combustion of unreacted anode off-gas. Recently, KEPRI is developing a new kW class SOFC stack and system to increase efficiency and durability at intermediate temperature.

  • PDF