국내 기상조건하 주거용 건물 가스 보일러의 부분부하 특성과 에너지 사용량 분석 (Analysis of the Part Load Ratio Characteristics and Gas Energy Consumption of a Hot Water Boiler in a Residential Building under Korean Climatic Conditions)

  • 유병호;서병모;문진우;이광호
    • 설비공학논문집
    • /
    • 제27권9호
    • /
    • pp.455-462
    • /
    • 2015
  • Residential buildings account for a significant portion of the total building-energy usage in Korea, and a variety of research studies on the domestic boiler have therefore been carried out; however, most of these studies examined the boiler itself, whereby the part-load ratio characteristics and the corresponding gas-energy consumption patterns were not analyzed. In this study, the part-load ratio and operating characteristics of a domestic gas boiler were analyzed within a residential building equipped with a radiant floor-heating system; in addition, the energy consumption between condensing and conventional boilers was comparatively analyzed. Our results show that significant portions of the total operating hours, heating load, and energy consumption are in the part-load ratio range of 0 through 40%, whereby the energy consumption was significantly affected by the boiler efficiency under low part-load conditions. These results indicate that the part-load operation of a boiler is an important factor in residential buildings; furthermore, replacing a conventional boiler with a condensing boiler can reduce annual gas-energy usage by more than 20%.

비저항에 따른 가스보일러용 304스테인리스강재의 손상거동에 관한 연구 (Study on the Damage Behavior of 304 Stainless Steel for Gas Boiler with Specific Resistance)

  • 윤병두;임우조;정기철
    • 한국가스학회지
    • /
    • 제9권4호
    • /
    • pp.6-10
    • /
    • 2005
  • 이 논문은 비저항에 따른 가스보일러용 오스테나이트계 스테인리스강(STS304)재의 손상거동에 관해 연구하기 위하여, 비저항에 따른 전기화학적 분극시험을 수행하였다. 그리고 비저항에 따른 가스보일러용 STS304강의 양극분극특성 및 손상거동인 공식양상을 고찰하였다. 비저항이 감소할수록 STS304강의 부동태유지전류밀도는 증가하고 부동태영역은 작아지고 있으며, 관통전위는 낮아지고 있다 또한 비저항이 가장 높은 $74{\Omega}{\cdot}m$중에서 손상거동인 공식양상은 거의 나타나지 않고, 비저항이 낮아질수록 손상거동인 공식양상은 더욱 성장되고, 공식수가 점점 증가하는 경향을 보이고 있다.

  • PDF

응축수 중에서 가스보일러용 STS 304의 부식거동에 관한 연구 (The Study on the Corrosion Behavior of STS 304 for Gas Boiler in the Condensed Water)

  • 윤병두;임우조;정기철
    • 한국가스학회지
    • /
    • 제9권1호
    • /
    • pp.21-25
    • /
    • 2005
  • 가스보일러용 오스테나이트계 스테인리스강재(STS 304)의 부식거동에 관해 연구하기 위하여, 응축수중에서 전기화학적 부식시험을 수행하여. STS 304의 전기화학적 부식거동을 고찰하였다. 다음과 같은 결론을 얻었다. 1)중성환경인 pH=6.5에서 pH가 낮아질수록 STS 304의 분극저항은 감소하고, 부식전위는 비전위화된다. 2)중성 및 산성환경 중에서 STS 304의 부식반응기구는 음극지배로 판단된다. 3) pH가 중성 환경인 pH=6.5에서 강산성 환경인 pH=0.5로 낮아질수록 STS 304의 부동태 전위영역이 감소하고 부동태유지 전류밀도는 증가하고 있다.

  • PDF

가스온수가열기의 용량에 따른 에너지효율성 비교 연구 (A Comparative Study on the Energy Efficiency due to the Capacity of Gas Boiler)

  • 김성중;우인성
    • 대한안전경영과학회지
    • /
    • 제17권2호
    • /
    • pp.229-234
    • /
    • 2015
  • Depending on the living styles, the types of energy consumed by households have changed, and the consumption has increased rapidly. Consequently, those have led to environmental issues, such as exhaustion of energy and the climate changes. As one of solutions to such issues, energy efficiency can be approached. Therefore, in this study, the gas water heater(115S type Rheem products) that made in Germany and obtain hot water using gas as a heat source is selected. a $1.0m^3$ water tank with a 6kW electronic heater is installed and a water temperature and pressure is maintain constantly also thermometer is injected. Two of gas meter, one of pressure regulator and three of time measurement devices are installed in a combustion facility and fuelling facility with a magnet valve so it can observe and record combustion reactions. Quantity of hot water that heated by boiler is recorded using a quantity measurement tank, and have been heated by the boiler have been to record and measure the amount and utilized the data acquired through measurement of all factors that are applied to acquire hot water in order to calculate the use rate of final energy. In conclusion, this researcher drew the economic strong points of the hot water generated by gas.

FGR 시스템 공력 플랜트 보일러의 성능 및 배기 배출물에 미치는 재순환 배기의 영향 (Effect of Recirculated Exhaust Gas upon Performance and Exhaust Emissions in Power Plant Boilers with FGR System)

  • 배명환;정광호;최승철;조용수;김이석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1686-1691
    • /
    • 2004
  • The effect of recirculated exhaust gas on performance and exhaust emissions with FGR rate are investigated by using a natural circulation, pressurized draft and water tube boiler with FGR system operating at several boiler loads and over fire air(OFA) damper openings. The purpose of this study is to apply the FGR system to a power plant boiler for reducing $NO_{x}$ emissions. To activate the combustion, the suction damper of two stage combustion system installed in the upper side of wind box is opened by handling the lever between $0^{\circ}$ and $90^{\circ}$ , and the OFA with 0 to 20% into the flame is supplied, as the combustion air supplied to burner is reduced. It is found that the fuel consumption rate divided by evaporation rate does not show an obvious tendency to increase or decrease with rising the FOR rate, and $NO_{x}$ emissions are decreased, at the same OF A damper opening, as FOR rates are elevated and boiler loads are dropped.

  • PDF

야외용 가스보일러의 연소판 형상에 따른 열응력 해석 (Thermal Stress Anaysis of Burning Plate by Configuration of Outdoor Gas Boiler)

  • 이석영
    • 에너지공학
    • /
    • 제24권4호
    • /
    • pp.48-54
    • /
    • 2015
  • 본 연구에서는 야외용 가스보일러 형상에 따른 연소판을 열응력 결과를 통해 분석하였다. 정상상태 모드로 계산한 결과, 최대 응력 및 변형은 A형상과 B형상에서 각각 666.8MPa, 0.20476mm로 분석되었다. 변형은 연소판 중심에서 바깥쪽으로 갈수록 증가하는 경향을 보였다. 또한, 8가지 형상 중에서 최대 응력과 변형은 F와 C형상이 가장 안전함을 각각 보였다. 따라서, 8가지 형상 중에서 F형상이 강도 및 안전성 측면에서 가장 우수하다고 판단되었으며, 가스보일러의 연소판 형상에 따른 계산된 결과를 분석함으로서 보일러 시스템에 대한 안전한 구성요소 변수를 실질적으로 적용할 수 있는 모델을 설계할 수 있게 되었다.

사고사례에 기초한 보일러 사고의 원인분석 및 대책 (Cause Analyses of Boiler Accident and Their Counter-plans Based on Accident Cases)

  • 윤상권;장통일;임현교
    • 한국안전학회지
    • /
    • 제18권3호
    • /
    • pp.131-140
    • /
    • 2003
  • An accident involving a boiler can result in a disaster since it handles high-pressurized steam so that it may cause an explosion. Therefore, the boiler is very susceptible to industrial accidents. This thesis aimed to develop counter-plans to prevent industrial accidents involved the boiler. At first after collecting accident cases involving boilers, a survey on the trait of them was carried out. Ant on the other hand a qualitative analysis was conducted to draw out hazardous components in the boiler itself and their inherent relative importance was assessed. Through this procedure, 'negligence of unsafe condition' was noted as the major cause for unsafe acts whereas 'fault in work procedure' for unsafe condition. In the meanwhile, results of a hazard analysis using FMEA technique ranked gas safety devices, a switch preventing gas from under-pressurization, protect relays high. In particular, it was pointed out that the water feeding and steam subsystem has more components in hazard than other subsystems. Considering these analyses results, counter-plans to improve safety management was suggested also.

가정용 가스보일러 곡관 배기통의 길이 변화에 따른 CO농도 고찰 (A Study on the Concentration of CO(Carbon Monoxide) by the Length of the Curved Exhaust Tube for Household Gas Boiler)

  • 임사환;허용정;마성준
    • 한국산학기술학회논문지
    • /
    • 제8권5호
    • /
    • pp.1220-1226
    • /
    • 2007
  • 21C 산업의 발전과 더불어 급증하고 있는 가스산업은 사용의 편리성과 위험성을 공존하고 있다. 특히 근대 산업혁명 이후 에너지 및 환경에 대한 문제가 두각을 나타내게 되었다. 따라서 환경친화적인 에너지원으로서 가스의 수요가 날로 급증하고 있다. 가스의 수요와 더불어 가스보일러의 설치 및 사용이 늘어나면서 보일러 폐가스(CO)에 의한 인명피해가 해마다 증가하고 있다. 따라서 본 논문의 목적은 보일러 곡관 배기통의 길이에 따른 CO농도의 고찰을 통하여 인체에 대한 위해성을 파악코자 함이다. CO의 허용농도인 50ppm에 해당하는 길이는 3곡관 1m에서 3분이 경과할 경우이다. 또한, 5m에서는 5분 경과부터 CO농도가 허용농도를 초과하는 것으로 나타났다. 특이하게 2m부터 4m까지는 CO농도가 허용농도 이하였다.

  • PDF

순산소 재순환 연소를 채택한 $CO_2$ 회수형 보일러 연소실에 대한 수치해석 (CFD STUDY ON THE COMBUSTION CHAMBER OF AN OXY-FUEL FGR BOILER FOR $CO_2$ CAPTURING)

  • 안준;김혁주
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 춘계학술대회논문집
    • /
    • pp.329-334
    • /
    • 2009
  • An oxy-fuel boiler has been developed to capture $CO_2$ from the exhaust gas. FGR (flue gas recirculation) is adopted to be compliant with the retrofit scenario. Numerical simulations have been performed to study the detailed physics inside the combustion chamber of the boiler. The temperature field obtained from the simulation agrees with the flame image from the experiment. The FGR combustion yields similar heat transfer characteristics with the conventional air combustion while the flame is formed further downstream in case of the FGR combustion.

  • PDF