• Title/Summary/Keyword: gas accident

Search Result 624, Processing Time 0.027 seconds

Analysis of Waterborne Automotive Refinish Paint for Investigating Insurance Fraud (차량 보수도장 보험사기 규명을 위한 수용성 페인트 성분분석)

  • Lee, Joon-Bae;Lee, Cheon-Ho;Ryu, Seung-Jin;Gong, Bokyoung;Kwon, O-Seong;Kim, Myung-Duck;Kim, Nam Yee;Paeng, Ki Jung
    • Applied Chemistry for Engineering
    • /
    • v.28 no.4
    • /
    • pp.490-494
    • /
    • 2017
  • With increasing the number of vehicles, the accident rate also goes up and the damaged vehicles should be painted as a final repair process. At the painting stage the solvent-based paint causes environmental problems. To overcome these problems waterborne refinish paint is frequently used recently. However, for waterborne refinish, the costs of insurance coverage are too expensive, and insurance reimbursement costs could be burdensome. Because of the high price of aquatic paint treatment, the service shop might charge the malicious service price. In this study, the surfactant of Surfynol 104, which is the component in the paint, was used as an indicator whether the vehicle was painted with waterborne paint. The specimen was quantitatively analyzed to contain 0.38% of the surfactant through the standard addition method with isotope substituted internal standard (IS) of fluranthene-d10 by curie point pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS).

A Study on the Improvement of Safety of Unloading Site by Comparison of Hydrogen Fluoride Leakage Accident (불화수소 누출사고 비교를 통한 하역작업장의 안전성 향상방안에 관한 연구)

  • Woo, Jongwoon;Shin, Changsub
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.32-38
    • /
    • 2018
  • The purpose of this study is to assess quantitatively the amount of leaks and the extent of dispersion in case of a leak at a hydrogen fluoride tank container unloading station, and to suggest a safety improvement plan to prevent recurrence of similar accidents. In 2012, Company H leaks 8 tonnes of tank containers with a maximum storage capacity of 18 Ton, causing it to become a social issue. As a result of calculation using Gaussian plume model, the concentration was estimated to be more than 20ppm from the leak point to 1,321 m radius. The leakage of hydrogen fluoride from the company R in 2014 was estimated to be 11.02 kg, of which 2.9 kg was treated by the scrubber. As a result of calculation using Gaussian plum model, the damage range with a concentration of 20ppm or more from the leak source was estimated to be 69 m in radius. As a result of comparing the above two accidents, it was found that the leakage amount was about 987 times different and the damaged site was more than 19 times different. Therefore, it was concluded that it was necessary to control the wearing of the protective equipment, the enclosure of the unloading site, the installation of the scrubber, and the emergency training to avoid the accidental leakage of a hydrogen fluoride from the unloading site.

A Study on Practical Analyzing and Improving Disaster Management Organization of Korean Government (재난관리조직의 실태분석과 발전방안)

  • 권오한;남상화;이춘하
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.127-138
    • /
    • 2001
  • I. introduction. A government goal at the present is established to make a welfare nation and to keep people's safe living, but it is criticised that when a large-scale disaster happens, the authority concerned could not deal with it, causing many people injured and material damage. Moreover, in these days, cities have many risk factors. extremely large and intelligent building, industrial facilities and underground equipment have many risk themselves along with scientific progress. The cope with disaster effectively, government must have efficient organization, skillful personnel, tool, facilities and so on. To reduce the damages, what's the most effective government organization\ulcorner II. Government organization for managing disaster In a few decades, a large-sized accidents broke out in korea, for example, collapse of Sampoong department store, break of Sungso bridge, explosion of Daegu city gas, gas explosion accident at Ahyon-dong etc. but government has not any adequate disaster response organization. Especially, after collapse of Sampoong department store broke out, Disaster Management Act is enacted to solve the past problem. According to Disaster management Act, disaster is limited in manmaid disaster. Therefore, in this thesis, disaster management is inspected theoretically, organization of disaster management for pattern of disaster, and role, duty of government organization, emergency relief organization system and actual conditions are analyzed. there are some problems. there are trials and errors. the government has changed the disaster management organization by the disaster management law. the organization consists of central and local government. but both of government do not work together harmoniously. in thesis, I would like to introduce the advanced nations disaster management organization, and study our central, local government organization. III. Conclusion Change and development of the government disaster management organization is the goal of this thesis. we have to increase public service in response and manage disaster. protecting civilian's life from the disaster is very important responsibility of government. there would be better way of government disaster management organization.

  • PDF

Risk Assessment and Safety Measures for Methanol Separation Process in BPA Plant (BPA 공장의 메탄올 분리공정에서 위험성 평가 및 안전대책)

  • Woo, In-Sung;Lee, Joong-Hee;Lee, In-Bok;Chon, Young-Woo;Park, Hee-Chul;Hwang, Seong-Min;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.3
    • /
    • pp.22-28
    • /
    • 2012
  • For a methanol separation column of the BPA (Bisphenol A) plant, HAZOP (hazard and operability) assessment was performed and damage ranges were predicted from the accident scenarios for the fire and the explosion. As a result, the damage range of the jet fire was 20 m in the case of rupture of the discharge pipe (50 mm diameter) of safety valve, and that of the flash fire was 267 m in the case of catastrophic rupture. Also, the damage ranges of the unconfined vapor cloud explosion (UVCE) for the rupture of the discharge pipe and for the catastrophic rupture were 22 m and 542 m, respectively. For the worst case of release scenarios, safety measures were suggested as follows: the pressure instruments, which can detect abnormal rise of the internal pressure in the methanol separation column, should be installed by the 2 out of 3 voting method in the top section of the column. Through the detection, the instruments should simultaneously shut down the control and the emergency shut-off valves.

A Study on the Safety Distance of Benzene and Acrylonitrile Releases in Sccordance with Dike and Hole Size (벤젠 및 아크릴로나이트릴 누출시 방류벽 유무 및 누출공에 따른 피해 영향범위 산정에 관한 연구)

  • Kawg, Youngmin;Oak, Jaemin;Yoon, Sukyoung;Jung, Seungho
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.1
    • /
    • pp.18-25
    • /
    • 2018
  • As the industries become more developed, the amounts of hazardous materials have been increased. Because of that, the possibility of accidents in plants is expected to increase. Especially, the dispersions of toxic materials cause serious effect to human life and environment, So it is very important to confirm safety distance of discharge accident. For this paper, we proposed new algorithms for toxic liquid, such as benzene and acrylonitrile. and using this argorithm, we are going to predict safety distance. The scenario of accidental release was assumed to be the release of entire quantity in 10 minutes is defined as worst-case scenario and Instantaneous release. Also the release from a partial rupture of line is used as an alternative case scenarios as NICS(National Institute of Chemical Safety) guidelines. Using ALOHA program and the algorithm for liquid toxic materials and suggested the graph, as well as correlated equations which can utilize emergency responders.

Cost-Benefit Analysis Method for Ageing Equipment of Chemical Plants Using Risk Assessment (위험성평가를 이용한 노후설비에 대한 비용 편익분석 방법)

  • Jung, Soomin;Jung, Changmo;Kang, Seok-Min;Chae, Seungbeen;Kang, Seung-Gyun;Ko, Jae Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.84-92
    • /
    • 2020
  • Most facilities in chemical plants operate in environments that are outside the range of temperature and pressure that can be encountered on a daily basis, and are vulnerable to aging due to these stresses and environmental conditions. The facilities exposed to these conditions are not only likely to fail due to cumulative damage, but also lead to accidents if maintenance and replacement are not performed.Recommendation guidelines called risk-based inspection are widely used around the world-wide. However, limits exist for facilities that have already elapsed for a certain. As a result of the survey on the aging of Ulsan industrial complex in Korea, which carries out proper inspection, many of the facilities have been used for 20 years. Also, most of the facilities where the accident occurred have been in operation for more than 20 years. Therefore, this study suggested criteria for classifying devices that have exceeded a certain period of use as obsolete facilities. In addition, quantitative risk assessment was conducted. The safety investment method using the cost-benefit analysis method was proposed in order to calculate the loss cost and reduce the risk by expressing the risks of the corresponding aged facility as an Economic index. By utilizing the method of cost-benefit analysis of old facilities using the quantitative risk assessment presented in this study, it can be expected to improve the performance and life of old facilities, improve production efficiency and reliability of the system of facilities, change the recognition of safety management costs, increase employee stability, and reduce loss costs.

Real-Time Location Identification of Indoor Rescuees at Accident Sites and Location-Based Rescue Response (사고 현장 실시간 실내 인명 위치확인 및 구조대응 연구)

  • Ko, Youngjoo;Shin, Yongbeom;Yoo, Sangwoo;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.3
    • /
    • pp.46-52
    • /
    • 2021
  • In this study, the on-site location identification and response system was proposed by accurately checking the location information of rescue requesters in the buildings using the smartphone Wi-Fi AP. The location server was requested to measure the strength of the Wi-Fi AP at least 25 times at 8 different building location points. And the accuracy of the position and the error range were checked by analyzing the coordinate values of the received positions. In addition, the response time was measured by changing the conditions of location information in three groups to compare the response time for saving lives with and without location information. The minimum and maximum error values for the eight cases were found to be at least 4.137 m and up to 14.037 m, respectively, with an average error of 9.525 m. Compared to the base transceiver station (BTS) based position error value of 263m, the range could be reduced by up to 93%. When the location information was given, it took 10 minutes and 50 seconds to save lives; however, when there was no location information at all, rescue process took more than 45 minutes. From this research effort, it was analyzed that the acquisition of the location information of rescuees in the building using the smartphone Wi-Fi AP approach is effective in reducing the life-saving time for on-site responses.

A Study on the Measurement of Explosion Range by CO2 Addition for the Process Safety Operation of Propylene (프로필렌의 공정안전 운전을 위한 CO2 첨가량에 따른 폭발범위 측정에 관한 연구)

  • Choi, Yu-Jung;Heo, Jong-Man;Kim, Jung-Hun;Choi, Jae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.599-606
    • /
    • 2019
  • Most facilities that manufacture products made from the hazardous materials operate at high temperatures and pressures. Therefore, there is a risk of fire explosion. In particular, an explosion accident is a major risk factor for facilities with hazardous materials, such as oil, chemical, and gas. Propylene is often used in sites producing basic raw materials and synthetic materials by addition polymerization at petrochemical plants. To prevent an explosion in the business using propylene, the explosion range with the oxygen concentration was calculated according to the changes in temperature and pressure using an inert gas, carbon dioxide. In these measurements, the temperature was $25^{\circ}C$, $100^{\circ}C$, and $200^{\circ}C$ and the amount of carbon dioxide in the container was $1.0kgf/cm^2.G$, $1.5kgf/cm^2.G$, $2.0kgf/cm^2.G$, and $2.5kgf/cm^2.G$. The explosion limit was related to temperature, pressure, and oxygen concentration. The minimum oxygen concentration for an explosion decreased with increasing temperature and pressure. The range of explosion narrowed with decreasing oxygen concentration. In addition, no explosion occurred at concentrations below the minimum oxygen concentration, even with steam and an ignition source of propylene.

Performance Evaluation of a Portable GC for Real-time Monitoring of Volatile Organic Compounds (휘발성 유기화합물의 실시간 모니터링을 위한 휴대형 GC의 성능 평가)

  • You, Dong-Wook;Seon, Yeong-Sik;Oh, Jun-Sik;Yi, Bongyoon;Kim, Hyun Sik;Jung, Kwang-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.6
    • /
    • pp.327-333
    • /
    • 2020
  • Performance of a portable GC that can be utilized for the real time determination of volatile organic compounds in air was evaluated. It employs purified/compressed ambient air as the carrier gas eliminating the need for high pressure gas tanks. The compact system with dimensions of 35 × 26 × 15 ㎤ and weight of 5 kg is powered by either a 24 V DC external adapter or battery pack. Chromatograms of the mixture sample including benzene, toluene, ethylbenzene, and oxylene at concentrations of 1 ppmv and 20 ppmv represent a good reproducibility: 3.79% and 0.48% relative standard deviations (RSDs) for peak area variations; 0.40% and 0.08% RSDs for retention times. The method detection limit was 0.09 ppmv. A 30 m long, 0.28 mm I.D. column operated at an optimal condition yielded a peak capacity of 61 with good resolution for a 10 min isothermal analysis. The relative standard deviations (RSD) of the peak area variations and retention times during consecutive measurements over 27 h were less than 2.4%RSD and 0.5%RSD, respectively. Thus, this instrument makes it suitable for continuous and field analysis of low-concentration VOC mixtures in the indoor/outdoor environment as well as the spillage accident of hazardous chemicals.

Quantitative Analysis of Damage Impacts in case of Bunkering NH3 from Tank Lorry to Fishing Vessel (어선-탱크로리 간의 NH3 이적 시 누출에 따른 정량적 피해영향분석)

  • Lim, Sang-Jin;Choi, Bu-Hong;Lee, Yoon-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.3
    • /
    • pp.10-20
    • /
    • 2022
  • About 21% of domestic chemical accidents are caused by transport vehicles for the past 10 years in Korea. Also, ammonia is a chemical substance with the largest number of accidents, 82 out of 672. In this study, supposed seasonal alternative scenario and worst scenario in case of releasing ammonia during bunkering it from tank lorry to fishing vessel and interpreted seasonal impact and range through Python, ALOHA, Probit analysis. Radiation impact range of possibility for 2nd burn and for maximum radiation in winter scenario, which is one of the alternative scenarios, was the highest(range: 41m, radiation: 5.01kW/m2) while overpressure impact was less than minimum standard of impact. And toxicity impact range(EPRG-2) of the summer scenario was the widest(5.0km) and took a very high death rate near accident area(port area, tourist area) according to Probit analysis. the wort scenario had a similar impact and range of summer scenario.