• Title/Summary/Keyword: gap distance

Search Result 584, Processing Time 0.022 seconds

Numerical Analysis of the Turbine Rotor Flow with the Unsteady Passing Wake from a Stator (정익에서 발생한 비정상 후류를 지나는 터빈 동익 유동장 수치해석)

  • Lee, Eun-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.4
    • /
    • pp.275-280
    • /
    • 2007
  • A turbine stage consists of stators and rotors. The stator provides the required inlet flow conditions so that the rotor can produce the necessary power. Passing wakes generated from the trailing edge of the stator make an interaction with the rotor. In the present study, this flow mechanism is investigated using the numerical analysis. In case of a large gap distance between the stator and rotor, the flow can be solved independently. First, only the stator flow field is solved. Second, the rotor flow field is solved including the passing wake characteristics obtained from the stator analysis. The passing wake experiences the shearing as it approaches to the rotor blade leading edge. And it is chopped when it strikes the rotor blade. After that, the chopped wakes becomes the prolongation as it travels downstream. The flow according to the variation of the gap distance is also studied. Pressure jumps due to the passing wakes result in the pressure and lift loss and it gets stronger with the closer gap distance.

Analysis of Parents' Perceptions and Needs for Distance Education and Educational Support for Students with Disabilities (장애학생 원격교육 및 교육지원에 대한 학부모의 인식 및 요구 분석)

  • Ku, Jeong-Ah;Son, Ji-Young
    • Journal of Practical Engineering Education
    • /
    • v.14 no.2
    • /
    • pp.447-457
    • /
    • 2022
  • The purpose of this study was to understand the parents' perceptions of the distance learning provided to students with disabilities and to explore the demands for educational support. A survey was conducted on a total of 2,392 parents of school-age children with disabilities. The survey questions were largely divided into the learning support to prevent educational gap, support for behavioral and psychological difficulties, and care support for educational welfare. As a result of the study, it was found that face-to-face education in schools was the most important to prevent the educational gap between students with disabilities, and counseling on distance learning methods and strategies suitable for the characteristics of the disabled in connection with the Special Education Support Center was the most necessary. As a learning support method for distance learning for students with disabilities, there was a high demand for individual learning support through preparatory special education teachers, and it was necessary to secure enough learning aids and assistive technology devices to be used appropriately when needed. In addition, psychological counseling and educational support for students with disabilities were requested, and there were demands for development of care programs suitable for the characteristics of the disabled and assignment of dedicated personnel. Based on the results of this study, this study suggested implications for students with disabilities to bridge the learning gap and provide educational support due to distance learning.

A new equation based on PGA to provide sufficient separation distance between two irregular buildings in plan

  • Loghmani, Adel;Mortezaei, Alireza;Hemmati, Ali
    • Earthquakes and Structures
    • /
    • v.18 no.5
    • /
    • pp.543-553
    • /
    • 2020
  • Past earthquakes experience shows that serious damage or collapse of buildings have dramatically accrued when sufficient separation distance has not been provided between two adjacent structures. The majority of past studies related to the pounding topic indicate that obtaining the gap size between two buildings is able to prevent collision and impact hazards during seismic excitations. Considering minimization of building collisions, some relationships have been suggested to determine the separation distance between adjacent buildings. Commonly, peak lateral displacement, fundamental period and natural damping as well as structural height of two adjacent buildings are numerically considered to determine the critical distance. Hence, the aim of present study is to focus on all mentioned parameters and also utilizing the main characteristic of earthquake record i.e. PGA to examine the lateral displacement of irregular structures close to each other and also estimate the sufficient separation distance between them. Increasing and decreasing the separation distance is inherently caused economical problems due to the land ownership from a legal perspective and pounding hazard as well. Therefore, a new equation is proposed to determine the optimum critical distance. The accuracy of the proposed formula is validated by different models and various earthquake records.

Prediction on Throttling Performance of a Movable Sleeve Injector for Deep Throttling (딥 스로틀링 가변 슬리브 인젝터의 추력제어 성능예측)

  • Park, Sunjung;Nam, Jeongsoo;Lee, Keonwoong;Koo, Jaye;Hwang, Yongsok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.6
    • /
    • pp.487-495
    • /
    • 2018
  • Experimental analysis of the spray characteristics of the movable sleeve injector, which can simultaneously control the area of the annular gap and the pintle gap, has been studied and a method for controlling the uniform performance over a wide thrust range has been studied. It is confirmed that the design flow rate is not satisfied when the constant pressure difference is set regardless of the opening distance of the sleeve. In order to improve this, the differential pressure in the annular gap and the pintle gap was applied differently according to the opening distance. It was confirmed that the design flow rate was satisfied within the operating range and thrust control was linear from 25% to 100% in linear sleeve area.

THE DIMENSIONAL CHANGE OF CAST IMPLANT BARS AFTER LABORATORY PROCEDURE

  • Kwon, Ji-Yung;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.354-361
    • /
    • 2007
  • Statement of Problems. The precision of fit between the bearing surfaces of implant abutments and the prosthesis framework has been considered fundamental to implant prosthodontic protocol. Purpose. The study aimed to investigate the effect of laboratory procedure on the dimensional accuracy of cast implant bars. Material and methods Thirty implant bars were fabricated on a metal master model. The gap distances were measured at the right implant abutment replica-gold cylinder interface after casting procedure. The bar length data of precasting and postcasting state were collected and analyzed. Results. The mean gap distance found after casting was $106.3{\mu}m$ for buccal side, $122.1{\mu}m$ for distal side and $117.1{\mu}m$ for the lingual side. The mean bar length was $17964.7{\mu}m$ at precasting measurement, $17891.6{\mu}m$ at postcasting measurement. The mean change of bar length was $-73.1{\mu}m$. Conclusion. Even though the techniques used in this study strictly followed the guidelines established in the literature, the 30 cast implant bars evaluated all yielded gap distances that were beyond acceptable accuracy. There was a statistically significant difference between precasting and postcasting bar length (P<0.01). There was a decreasing tendency in bar length after casting procedure. It was necessary to correct this dimensional change from laboratory procedure by some corrective methods.

Spatial Distance Effect in Shaping Perceived Similarity of Products in the Online Store

  • JANG, Jung Min
    • Journal of Distribution Science
    • /
    • v.19 no.2
    • /
    • pp.53-64
    • /
    • 2021
  • Purpose: Even though arranging images of products is a common practice in the online retail context, relatively little attention has been paid to the distance effect among alternatives, that is, how distance among displayed products can impact consumers' responses. Drawing on contagion theory, the primary goal of the current study is to investigate how spatial distance between two products in a product display can influence consumers' perceived similarity. Research design, data and methodology: This study used a 2(spatial distance: close vs. far) experimental design and collected data from undergraduate students in Korea through an online survey using Qualtrics. ANOVA was conducted to test the proposed effect, in which the dependent variables are the perceived similarity of usage occasion/purpose (Study 1) and the indexed differences of perceived brand statuses between two products (Study 2). Results: The results of both experiments indicated that the displayed products were perceived to be more similar to one another when products were presented close together (vs. far). Conclusions: The results help to fill a research gap and provide a better understanding of the role of physical distance in diverse marketing communications. This is especially useful when designing online shopping websites to form perceptions of brand images.

A Turbulent Boundary Layer Disturbed by an Elliptic Cylinder (타원형 실린더에 의해 교란되어진 난류경계층에 관한 실험적 연구)

  • Choe, Jae-Ho;Jo, Jeong-Won;Lee, Sang-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1476-1482
    • /
    • 2001
  • Turbulent boundary layer over a flat plate was disturbed by installing an elliptic cylinder with an axis ratio of AR=2. For comparison, the same experiment was carried out for a circular cylinder having the same vertical height. The surface pressure and the heat transfer coefficient on the flat plate were measured with varying the gap distance between the elliptic cylinder and the flat plate. The mean velocity and the turbulent intensity profile of the streamwise velocity component were measured using a hot-wire anemometry. As a result, the flow structure and the local heat transfer rate were modified by the interaction between the cylinder wake and the turbulent boundary layer as a function of the critical gap ratio where the regular vortices start to shed. For the elliptic cylinder, the critical gap ratio is increased and the surface pressure on the flat plate is recovered rapidly at downstream location, compared with the equivalent circular cylinder. The maximum heat transfer rate occurs at the gap ratio of G/B = 0.5, where the flow interaction between the lower shear layer of the cylinder wake and the turbulent boundary layer is strong.

A Study on Development of an Electromagnetic Inductive Sensor for Automatic Weld Seam Tracking (용접선 자동추적용 전자기유도센서의 개발에 관한 연구)

  • Bae Kang-Yul
    • Journal of Welding and Joining
    • /
    • v.23 no.4
    • /
    • pp.66-72
    • /
    • 2005
  • An electromagnetic inductive sensor consisted of one exciter and three separated (triple) detectors has been developed for both tracking the weld seam of a workpiece and controlling the sensor-to-workpiece distance (height) simultaneously. The left and right detectors are used to track the seam, while the fore and the other two detectors allow the sensor to determine the height and the gap width by being coupled their outputs together. A series of experiments with the proposed sensor located above a mild steel plate containing a weld seam of gap are carried out to examine the feasibility of the sensor. The results revealed that the proposed sensor could fairly well track the desired seam and also well control the height to be constant even when the gap width of the seam varied. The gap width can be also determined during the seam tracking by using the sensor outputs. As a consequence, these can provide the developed sensor with substantial improvement for industrial uses with respect to the previous electromagnetic sensors being used for the weld seam tracking.

A Pulser System with Parallel Spark Gaps at High Repetition Rate

  • Lee, Byung-Joon;Nam, Jong-Woo;Rahaman, Hasibur;Nam, Sang-Hoon;Ahn, Jae-Woon;Jo, Seung-Whan;Kwon, Hae-Ok
    • Journal of IKEEE
    • /
    • v.15 no.4
    • /
    • pp.305-312
    • /
    • 2011
  • A primary interest of this work is to develop an efficient and powerful repetitive pulser system for the application of ultra wide band generation. The important component of the pulser system is a small-sized coaxial type spark gap with planar electrodes filled with SF6 gas. A repetitive switching action by the coaxial spark gap generates two consecutive pulses in less than a microsecond with rise times of a few hundred picoseconds (ps). A set of several parameters for the repetitive switching of the spark gap is required to be optimized in charging and discharging systems of the pulser. The parameters in the charging system include a circuit scheme, circuit elements, the applied voltage and current ratings from power supplies. The parameters in the discharging system include the spark gap geometry, electrode gap distance, gas type, gas pressure and the load. The characteristics of the spark gap discharge, such as breakdown voltage, output current pulse and recovery rate are too dynamic to control by switching continuously at a high pulse repetition rate (PRR). This leads to a low charging efficiency of the spark gap system. The breakthrough of the low charging efficiency is achieved by a parallel operation of two spark gaps system. The operational behavior of the two spark gaps system is presented in this paper. The work has focused on improvement of the charging efficiency by scaling the PRR of each spark gap in the two spark gaps system.

Assessment of Accessibility to Medical Facilities in Rural Areas using Real Road Distance focusing on Pyeongchang-gun (실제 도로거리를 이용한 농촌지역 생활권의 의료시설 접근성 평가 -평창군을 중심으로-)

  • Kim, Solhee;Kim, Taegon;Suh, Kyo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.4
    • /
    • pp.39-49
    • /
    • 2015
  • Since most medical facilities and medical personnel are concentrated in urban areas in South Korea, an imbalance of access to medical facilities causes a gap in medical resource availability between urban and rural areas. Accessibility to medical facilities is a means of assessment that evaluates a measure of inequality in utilization of medical resources. The evaluation of accessibility uses Euclidean distance, in general; however, this method has its limits in that Euclidean distance cannot reflect actual distance. This study aims to estimate real road distance from village halls to medical facilities in rural areas using Open Application Programming Interface (Open API) of an internet portal site. Using real road distance, we evaluated medical accessibility and compared it with Euclidean distance. The accessibility to primary medical institutions was valued relatively well, but secondary and tertiary medical institutions were vulnerable in Pyeonchang-gun. Comparing Euclidean distance with real road distance from village halls to medical facilities, real road distance appeared to be approximately 1.4 times that of Euclidean distance. This calculation is similar to the circuity factor of Gangwon-do in Korea that estimated to fix the limits of Euclidean distance and assumed real road distance.