• Title/Summary/Keyword: gamma-ray observations

Search Result 57, Processing Time 0.025 seconds

Studies on the Construction of Mutant Diversity Pool (MDP) lines, and their Genomic Characterization in Soybean

  • Dong-Gun Kim;Sang Hoon Kim;Chang-Hyu Bae;Soon-Jae Kwon
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2021.04a
    • /
    • pp.9-9
    • /
    • 2021
  • Mutation breeding is useful for improving agronomic characteristics of various crops. In this study, we constructed soybean Mutant Diversity Pool (MDP) from 1,695 gamma-irradiated mutants through two selection phases over M1 to M12 generations; we selected 523 mutant lines exhibiting at least 30% superior agricultural characteristics, and, second, we eliminated redundant morphological phenotypes in the M12 generation. Finally, we constructed 208 MDP lines and investigated 11 agronomic traits. We then assessed the genetic diversity and inter-relationships of these MDP lines using target region amplification polymorphism (TRAP) markers. Among the different TRAP primer combinations, polymorphism levels and PIC values averaged 59.71% and 0.15, respectively. Dendrogram and population structure analyses divided the MDP lines into four major groups. According to an analysis of AMOVA, the percentage of inter-population variation among mutants was 11.320 (20.6%), whereas mutant inter-population variation ranged from 0.231 (0.4%) to 14.324 (26.1%). Overall, the genetic similarity of each cultivar and its mutants were higher than within other mutant populations. In an analysis of the genome-wide association study (GWAS) using based on the genotyping-by-sequencing (GBS), we detected 66 SNPs located on 13 different chromosomes were found to be highly associated with four agronomic traits: days of flowering (33 SNPs), flower color (16 SNPs), node number (6 SNPs), and seed coat color (11 SNPs). These results are consistent with those previously reported for other genetic resource populations, including natural accessions and recombinant inbred line. Our observations suggest that genomic changes in mutant individuals induced by gamma rays occurred at the same loci as those of natural soybean population. This study has demonstrated that the integration of GBS and GWAS can serve as a powerful complementary approach to gamma-ray mutation for the dissection of complex traits in soybean.

  • PDF

PRELIMINARY FEASIBILITY STUDY OF THE SOLAR OBSERVATION PAYLOADS FOR STSAT-CLASS SATELLITES

  • Moon, Yong-Jae;Cho, Kyung-Seok;Jin, Ho;Chae, Jong-Chul;Lee, Sung-Ho;Seon, Kwang-Il;Kim, Yeon-Han;Park, Young-Deuk
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.4
    • /
    • pp.329-342
    • /
    • 2004
  • In this paper, we present preliminary feasibility studies on three types of solar observation payloads for future Korean Science and Technology Satellite (STSAT) programs. The three candidates are (1) an UV imaging telescope, (2) an UV spectrograph, and (3) an X-ray spectrometer. In the case of UV imaging telescope, the most important constraint seems to be the control stability of a satellite in order to obtain a reasonably good spatial resolution. Considering that the current pointing stability estimated from the data of the Far ultraviolet Imaging Spectrograph (FIMS) onboard the Korean STSAT-1, is around 1 arc minutes/sec, we think that it is hard to obtain a spatial resolution sufficient for scientific research by such an UV Imaging Telescope. For solar imaging missions, we realize that an image stabilization system, which is composed of a small guide telescope with limb sensor and a servo controller of secondary mirror, is quite essential for a very good pointing stability of about 0.1 arcsec. An UV spectrograph covering the solar full disk seems to be a good choice in that there is no risk due to poor pointing stability as well as that it can provide us with valuable UV spectral irradiance data valuable for studying their effects on the Earth's atmosphere and satellites. The heritage of the FIMS can be a great advantage of developing the UV spectrograph. Its main disadvantage is that two major missions are in operation or scheduled. Our preliminary investigations show that an X-ray spectrometer for the full disk Sun seems to be the best choice among the three candidates. The reasons are : (1) high temporal and spectral X-ray data are very essential for studying the acceleration process of energetic particles associated with solar flares, (2) we have a good heritage of X-ray detectors including a rocket-borne X-ray detector, (3) in the case of developing countries such as India and Czech, solar X-ray spectrometers were selected as their early stage satellite missions due to their poor pointing stabilities, and (4) there is no planned major mission after currently operating Reuven Ramaty High-Energy Solar Spectroscopic Imager (RHESSI) mission. Finally, we present a preliminary design of a solar X-ray spectrometer covering soft X-ray (2 keV) to gamma ray (10 MeV).

Effects of Plasticizer to Polyvinylchloride on Radio-resistance of Organic Stabilizer,Dielectric and Mechanical Characteristics under the Influence of Radiation (Polyvinylchloride에 있어 가소제의 첨가가 유기안정제의 내 방사성 및 유전, 기계적 특성에 미치는 영향)

  • 김봉흡;강도열;이재인
    • 전기의세계
    • /
    • v.26 no.2
    • /
    • pp.89-94
    • /
    • 1977
  • In order to investigate the properties of radiation resistance together with dielectric, and mechanical relaxation behaviors of polyvinylcholoride exposed to several different doses under the .gamma.-ray of Co$^{60}$ source, several observations were carried out on the exposed specimens propared by mixing dibutyl-tin-dilaulate and dibutyl-tin-dimaleate as stabilizer with or without adding dioctyl-phthalate as plasticizer. Conclusions obtained from the study are as follows: The origin of the absorption band at 1,540-1,640$cm^{-1}$ / on I.R. spectrum seems to be RCOO- ion originated from ionization of the stabilizer, and this peak can be useful as a measure of radiation resistance on polyvinylchloride. Addition of increasing plasticizer to polyvinylchloride exhibits increasing radiation resistance and the reason for this result may be attributed to aromatic resonance absorption of radiation energy by diotylphthalate. On dose dependent dielectric characteristics, nonplastized specimen shows a peak at about 10 Mrad and that this peak disappears on the plastification of specimens. Those phenomena may be explainable in considering the statistical distribution of scissored chain molecular segments as well as the plastification process of plasticizer to polyvinylchloride chain molecules.

  • PDF

Effect of ionizing radiation on cultured submandibular gland (SG) cells of mouse (전리 방사선 조사에 의한 마우스 배양 악하선 세포의 변화)

  • Lee, Song-Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.4 no.1
    • /
    • pp.71-77
    • /
    • 1990
  • The present study was undertaken to investigate effects of ionizing radiation on DNA synthesis and chromosomal abnormality in cultured submandibular gland(SG) cells. SG cells from C57BL/6N Crj mice were cultured in Dulbecco's modified Eagle's medium (DME) supplemented with $10\%$ fetal bovine serum, antibiotics and fungizone. The cultured SG cells were irradiated with graded doses of gamma ray ($^{60}Co$) at a dose rate of 58.4rad/min. The effect of irradiation of $^{60}Co$ on DNA synthesis in cultured cells was evaluated by measuring the incorporation of 3H-TdR. Using conventional chromosome techniques and Giemsa staining methods, chromosomal abnormalities in cultured SG cells, induced by irradiation of $^{60}Co$ werw examined. Cytological observations were carried out by a light microscope with high resolving power. The results obtained were as follows : 1. DNA synthesis of SG cells was quantitatively dependent on a radiation dose compare to control. 2. A polyploids and few chromosome-type break, such as single and double breaks, deltions and triradial figures were more predominantly in irradiated SG cells than in control. This increase of chromosomal abnormality was in the proposition to the irradiation doses.

  • PDF

Wide-Field Imaging Telescope-0(WIT0): A New Wide-Field 0.25 m Telescope at McDonald Observatory

  • Lee, Sang-Yun;Im, Myungshin;Pak, Soojong;Ji, Tae-Geun;Lee, Hye-In;Hwang, Seong Yong;Marshall, Jennifer;Prochaska, Travis;Gibson, Coyne A.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.1
    • /
    • pp.34.2-34.2
    • /
    • 2017
  • A small wide-field imaging telescope is a powerful instrument to survey the Universe: wide-field image can monitor the variability of many sources at a time, e.g. young stellar objects and active galactic nuclei, and it can be an effective way to locate transient sources without precise positional information such as gravitational wave sources or some gamma-ray bursts. In February 2017, we installed a 0.25 m f/3.6 telescope on the McDonald 0.8 m telescope as a piggyback system. With a $4k{\times}4k$ CCD camera, the telescope has a $2.35{\times}2.35deg$ field-of-view. Currently, it is equipped with Johnson UBVRI filters and 3 narrow-band filters: $H{\alpha}$, OIII and SII. We will present the installation process, and the telescope performance such as detection limit and image quality based on the data from commissioning observations. We will also discuss possible scientific projects with this system.

  • PDF

Multi-Messenger Observation of Gravitational Wave Source GW170817

  • Im, Myungshin;Kim, Joonho;Choi, Changsu;Lim, Gu;Lee, Chung-Uk;Kim, Seung-Lee;Lee, Mok Hyung;Yoon, Yongmin;Lee, Seong-Kook;Ko, Jongwan;Shim, Hyunjin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.31.3-31.3
    • /
    • 2018
  • On August 17th 2017, for the first time in the history, the gravitational wave (GW) detectors recorded signals coming from the merger of two neutron stars. This event was named as GW170817, and more interestingly, gamma-ray emission was detected 2 seconds after the gravitational wave signal, and 11 hours later, telescopes in Chile identified that the GW signal came from the NGC 4993 galaxy at the distance of about 40 Mpc. This is again the first time that electromagnetic (EM) signals are detected for a GW source. The follow-up observations by astronomers all around the world, including our group in Korea, successfully identified the optical emission as the kilonova, the elusive optical/NIR counterpart that has been proposed to originate from a neutron star merger. This whole event started the new era of astronomy, so-called the "multi-messenger astronomy", where the combined information from GW and EM radiation reveals an unprecedented view of the universe. In this talk, I summarize this exciting event, and describe the efforts by Korean astronomers that have led to important discoveries about the kilonova and the host galaxy properties, and finally provide the future prospects.

  • PDF

Analysis of Variation for Parallel Test between Reagent Lots in in-vitro Laboratory of Nuclear Medicine Department (핵의학 체외검사실에서 시약 lot간 parallel test 시 변이 분석)

  • Chae, Hong Joo;Cheon, Jun Hong;Lee, Sun Ho;Yoo, So Yeon;Yoo, Seon Hee;Park, Ji Hye;Lim, Soo Yeon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.51-58
    • /
    • 2019
  • Purpose In in-vitro laboratories of nuclear medicine department, when the reagent lot or reagent lot changes Comparability test or parallel test is performed to determine whether the results between lots are reliable. The most commonly used standard domestic laboratories is to obtain %difference from the difference in results between two lots of reagents, and then many laboratories are set the standard to less than 20% at low concentrations and less than 10% at medium and high concentrations. If the range is deviated from the standard, the test is considered failed and it is repeated until the result falls within the standard range. In this study, several tests are selected that are performed in nuclear medicine in-vitro laboratories to analyze parallel test results and to establish criteria for customized percent difference for each test. Materials and Methods From January to November 2018, the result of parallel test for reagent lot change is analyzed for 7 items including thyroid-stimulating hormone (TSH), free thyroxine (FT4), carcinoembryonic antigen (CEA), CA-125, prostate-specific antigen (PSA), HBs-Ab and Insulin. The RIA-MAT 280 system which adopted the principle of IRMA is used for TSH, FT4, CEA, CA-125 and PSA. TECAN automated dispensing equipment and GAMMA-10 is used to measure insulin test. For the test of HBs-Ab, HAMILTON automated dispensing equipment and Cobra Gamma ray measuring instrument are used. Separate reagent, customized calibrator and quality control materials are used in this experiment. Results 1. TSH [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [14.8 / 4.4 / 3.7 / 0.0 ] C-2(middle concentration) [10.1 / 4.2 / 3.7 / 0.0] 2. FT4 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [10.0 / 4.2 / 3.9 / 0.0] C-2(high concentration) [9.6 / 3.3 / 3.1 / 0.0 ] 3. CA-125 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 4.3 / 4.3 / 0.3] C-2(high concentration) [6.5 / 3.5 / 4.3 / 0.4] 4. CEA [%diffrence Max / Mean / median] (P-value by t-test > 0.05) C-1(low concentration) [9.8 / 4.2 / 3.0 / 0.0] C-2(middle concentration) [8.7 / 3.7 / 2.3 / 0.3] 5. PSA [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [15.4 / 7.6 / 8.2 / 0.0] C-2(middle concentration) [8.8 / 4.5 / 4.8 / 0.9] 6. HBs-Ab [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 3.7 / 2.7 / 0.2] C-2(high concentration) [8.9 / 4.1 / 3.6 / 0.3] 7. Insulin [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [8.7 / 3.1 / 2.4 / 0.9] C-2(high concentration) [8.3 / 3.2 / 1.5 / 0.1] In some low concentration measurements, the percent difference is found above 10 to nearly 15 percent in result of target value calculated at a lower concentration. In addition, when the value is measured after Standard level 6, which is the highest value of reagents in the dispensing sequence, the result would have been affected by a hook effect. Overall, there was no significant difference in lot change of quality control material (p-value>0.05). Conclusion Variations between reagent lots are not large in immunoradiometric assays. It is likely that this is due to the selection of items that have relatively high detection rate in the immunoradiometric method and several remeasurements. In most test results, the difference was less than 10 percent, which was within the standard range. TSH control level 1 and PSA control level 1, which have low concentration target value, exceeded 10 percent more than twice, but it did not result in a value that was near 20 percent. As a result, it is required to perform a longer period of observation for more homogenized average results and to obtain laboratory-specific acceptance criteria for each item. Also, it is advised to study observations considering various variables.