• Title/Summary/Keyword: gamma tool

Search Result 170, Processing Time 0.03 seconds

SCAR markers were developed to identify zoysiagrass mutants exhibiting fine leaf characteristics (세엽 한국들잔디 변이체 식별을 위한 SCAR 마커 개발)

  • Chung, Sung Jin;Park, Su Jeong;Choi, Young In;Kim, In-Kyung;Lee, Ka-Yeon;Kim, Hun-Joong;Lee, Geung-Joo
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.2
    • /
    • pp.115-121
    • /
    • 2013
  • Polymorphic bands of two fine-leaf zoysiagrass mutants (CNU 70-1, CNU 70-2) induced via a gamma-ray irradiation on seeds of Zoysia japonica were obtained by using randomly amplified polymorphic DNA (RAPD) primers. The genotype-specific fragments were then converted into PCR-based sequence characterized amplified region (SCAR) markers, which are now amenable to detecting them among other zoysiagrass species widely noticeable in Korea. The CNU 70-1-specific primer set amplified about 900 bp successfully, while the CNU 70-6 marker produced the expected 1,500 bp band, by which those markers were nominated by CNU 70-1_900 and CNU 70-6_1500 SCARs, respectively. The developed SCAR markers can be an applicable tool in sod industry where illegal appropriation hampers breeder's right and profits due to the turfgrass plant vegetatively propagating.

An Experimental Study on Density Tool Calibration (밀도검층 검출기 보정에 관한 기초 연구)

  • Kim, Yeonghwa;Kim, Kiju;Lim, Heontae;Kim, Jihoon;Kong, Nam-Young
    • Journal of the Korean Geophysical Society
    • /
    • v.7 no.4
    • /
    • pp.237-245
    • /
    • 2004
  • Series of basic experiments for current density calibration by user process and for density calibration using geophysical model borehole were made. We tried to find the sonde response characteristics for current calibration using water and aluminium field jig, and using the equation of half life of 137Cs source. The result of calibration test made in a geophysical model borehole built first in Korea shows a perfect linear calibration equation. By adopting this calibration equation we could estimate the limitation as well as possibility of current density calibration by user process.

  • PDF

Uncertainty quantification of PWR spent fuel due to nuclear data and modeling parameters

  • Ebiwonjumi, Bamidele;Kong, Chidong;Zhang, Peng;Cherezov, Alexey;Lee, Deokjung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.715-731
    • /
    • 2021
  • Uncertainties are calculated for pressurized water reactor (PWR) spent nuclear fuel (SNF) characteristics. The deterministic code STREAM is currently being used as an SNF analysis tool to obtain isotopic inventory, radioactivity, decay heat, neutron and gamma source strengths. The SNF analysis capability of STREAM was recently validated. However, the uncertainty analysis is yet to be conducted. To estimate the uncertainty due to nuclear data, STREAM is used to perturb nuclear cross section (XS) and resonance integral (RI) libraries produced by NJOY99. The perturbation of XS and RI involves the stochastic sampling of ENDF/B-VII.1 covariance data. To estimate the uncertainty due to modeling parameters (fuel design and irradiation history), surrogate models are built based on polynomial chaos expansion (PCE) and variance-based sensitivity indices (i.e., Sobol' indices) are employed to perform global sensitivity analysis (GSA). The calculation results indicate that uncertainty of SNF due to modeling parameters are also very important and as a result can contribute significantly to the difference of uncertainties due to nuclear data and modeling parameters. In addition, the surrogate model offers a computationally efficient approach with significantly reduced computation time, to accurately evaluate uncertainties of SNF integral characteristics.

Preparation of High GABA-Enriched Yeast Extract by Non-Saccharomyces Yeasts Isolated from Korean Traditional Fermented Soybean Product

  • Song, Nho-Eul;Lee, Da-Bin;Lee, Seon-Hye;Baik, Sang-Ho
    • Microbiology and Biotechnology Letters
    • /
    • v.49 no.3
    • /
    • pp.320-328
    • /
    • 2021
  • High GABA-enriched yeast extract, for various nutritionally and pharmaceutically important functional foods, was prepared using a novel isolate of Debaryomyces hansenii JBCC541. Under optimized conditions, GABA conversion rates are significantly enhanced up to 7.55 g/l by D. hansenii JBCC541, increasing their synthesis yield 40 times. The total amino acid content of the prepared yeast extract was 10733.86 mg/l (257.36 mg/g), consisting of alanine, lysine, glutamine, leucine, and valine as the primary amino acids. The GABA content was significantly enhanced up to 6790 mg/l (162.80 mg/g) in the presence of glutamic acid, with approximately 10-fold higher GABA production. Flavor amino acids were also highly enhanced, indicating that the prepared yeast extract might be useful for preparing various functional and sensuous foods. Our results were promising as a GABA-enriched yeast extract preparation tool ensuring a suitable food material level with the potential for functionally enhanced food industrial applications.

Anomaly Detection and Diagnostics (ADD) Based on Support Vector Data Description (SVDD) for Energy Consumption in Commercial Building (SVDD를 활용한 상업용 건물에너지 소비패턴의 이상현상 감지)

  • Chae, Young-Tae
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.579-590
    • /
    • 2018
  • Anomaly detection on building energy consumption has been regarded as an effective tool to reduce energy saving on building operation and maintenance. However, it requires energy model and FDD expert for quantitative model approach or large amount of training data for qualitative/history data approach. Both method needs additional time and labors. This study propose a machine learning and data science approach to define faulty conditions on hourly building energy consumption with reducing data amount and input requirement. It suggests an application of Support Vector Data Description (SVDD) method on training normal condition of hourly building energy consumption incorporated with hourly outdoor air temperature and time integer in a week, 168 data points and identifying hourly abnormal condition in the next day. The result shows the developed model has a better performance when the ${\nu}$ (probability of error in the training set) is 0.05 and ${\gamma}$ (radius of hyper plane) 0.2. The model accuracy to identify anomaly operation ranges from 70% (10% increase anomaly) to 95% (20% decrease anomaly) for daily total (24 hours) and from 80% (10% decrease anomaly) to 10%(15% increase anomaly) for occupied hours, respectively.

Development of a dose estimation code for BNCT with GPU accelerated Monte Carlo and collapsed cone Convolution method

  • Lee, Chang-Min;Lee Hee-Seock
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1769-1780
    • /
    • 2022
  • A new method of dose calculation algorithm, called GPU-accelerated Monte Carlo and collapsed cone Convolution (GMCC) was developed to improve the calculation speed of BNCT treatment planning system. The GPU-accelerated Monte Carlo routine in GMCC is used to simulate the neutron transport over whole energy range and the Collapsed Cone Convolution method is to calculate the gamma dose. Other dose components due to alpha particles and protons, are calculated using the calculated neutron flux and reaction data. The mathematical principle and the algorithm architecture are introduced. The accuracy and performance of the GMCC were verified by comparing with the FLUKA results. A water phantom and a head CT voxel model were simulated. The neutron flux and the absorbed dose obtained by the GMCC were consistent well with the FLUKA results. In the case of head CT voxel model, the mean absolute percentage error for the neutron flux and the absorbed dose were 3.98% and 3.91%, respectively. The calculation speed of the absorbed dose by the GMCC was 56 times faster than the FLUKA code. It was verified that the GMCC could be a good candidate tool instead of the Monte Carlo method in the BNCT dose calculations.

Determination of optimum gamma ray range for radiation mutagenesis and hormesis in quinoa (Chenopodium quinoa Willd.)

  • Park, Chan Young;Song, Seon Hwa;Sin, Jong Mu;Lee, Hyeon Young;Kim, Jin Baek;Shim, Sang In
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.240-240
    • /
    • 2017
  • Quinoa (Chenopodium quinoa Willd.) is one of the ancient crops cultivated in the Andes region at an altitude of 3,500-4000m in Chile and Bolivia from 5000 BC. It contains a large amount of protein, minerals and vitamins in comparison with other crops. The cultivation area has been increasing worldwide because of its excellent resistance to various abiotic stress such as salinity, drought and low temperature. ${\gamma}$-Ray radiation of high dose is often used as a tool to induce mutations in plant breeding, but it has a deleterious effect on organisms. However, the radiation may have a positive stimulatory effect of 'hormesis' in the low dose range. This experiment was carried out to investigate the optimum dose range for creating the quinoa genetic resources and to investigate the hormesis effect at low dose on the quinoa. This experiment was performed for 120 days from November, 2016 to February, 2017 in the greenhouse of Gyeongsang National University. ${\gamma}$-Ray radiation was irradiated to seeds at 0 Gy, 50 Gy, 100 Gy, 200 Gy, 300 Gy, 400 Gy, 600 Gy, 800 Gy and 1000 Gy for 8 hours. (50 Gy) using the low level radiation facility ($Co^{60}$) of Cooperative Research Institute of Radiation Research Institute, KAERI. Fifty seeds were placed on each petri dish lined with wet filter paper and germination rate was measured at a time interval of 2 hours for 40 hrs. The length of the root length was measured one week after germination. Each treatment was carried out in 3 replicates. The growth of seedlings were investigated for 10 days after transplanting of 30 day-old seedlings. The plant height, NDVI, SPAD, Fv/Fm, and panicle weight were measured. The germination rate was highest at 50Gy and 0Gy and the rate of seeds treated with 400Gy or higher rate decreased to 25% of the seeds treated with 50Gy. The emergence rate of seedling in pot experiment was higher at the dose of 200 Gy, 300 Gy and 400 Gy than at 0 and 50Gy. However, the rate was lower at strong radiation higher than 600Gy at which $1^{st}$ leaf was not expanded fully and dead due to extreme overgrowth at 44 days after treatment (DAT). The highest value of panicle weight was observed at 50Gy (6.15g) and 100Gy (5.57g). On the other hand, the weight at high irradiated dose of 300Gy and 400Gy was decreased by about 55% compared to low dose (50 Gy). NDVI measurement also showed the highest value at 50 Gy as the growth progressed. SPAD was the highest at 400 Gy and showed positive correlation with irradiation dose except 0 Gy. Fv/Fm was high at 50 Gy up to 30 DAT and no difference between treatments was observed except for 400 Gy from 44 DAT. The plant height was the highest in 50Gy during the growing period and was higher in the order of 50Dy, 100Gy, 0Gy, 200Gy, 300Gy and 400Gy in 88 DAT. In this experiment, the optimal radiation dose for hormesis was 50Gy and 100Gy, and the optimal radiation dose for mutagenesis seems to be 400 Gy.

  • PDF

Verification of Non-Uniform Dose Distribution in Field-In-Field Technique for Breast Tangential Irradiation (유방암 절선조사 시 종속조사면 병합방법의 불균등한 선량분포 확인)

  • Park, Byung-Moon;Bae, Yong-Ki;Kang, Min-Young;Bang, Dong-Wan;Kim, Yon-Lae;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.277-282
    • /
    • 2010
  • The study is to verify non-uniform dose distribution in Field-In-Field (FIF) technique using two-dimensional ionization chamber (MatriXX, Wellhofer Dosimetrie, Germany) for breast tangential irradiation. The MatriXX and an inverse planning system (Eclipse, ver 6.5, Varian, Palo Alto, USA) were used. Hybrid plans were made from the original twenty patients plans. To verify the non-uniform dose distribution in FIF technique, each portal prescribed doses (90 cGy) was delivered to the MatriXX. The measured doses on the MatriXX were compared to the planned doses. The quantitative analyses were done with a commercial analyzing tool (OmniPro IMRT, ver. 1.4, Wellhofer Dosimetrie, Germany). The delivered doses at the normalization points were different to average 1.6% between the calculated and the measured. In analysis of line profiles, there were some differences of 1.3-5.5% (Avg: 2.4%), 0.9-3.9% (Avg: 2.5%) in longitudinal and transverse planes respectively. For the gamma index (criteria: 3 mm, 3%) analyses, there were shown that 90.23-99.69% (avg: 95.11%, std: 2.81) for acceptable range ($\gamma$-index $\geq$ 1) through the twenty patients cases. In conclusion, through our study, we have confirmed the availability of the FIF technique by comparing the calculated with the measured using MatriXX. In the future, various clinical applications of the FIF techniques would be good trials for better treatment results.

Optimization of Parallel-Hole Collimator for Small Gamma Camera Based on Pixellated Crystal Array (배열형 섬광결정을 이용한 소형 감마카메라의 평행구멍형 조준기 최적화 연구)

  • Chung, Yong-Hyun;Beak, Cheol-Ha;Lee, Seung-Jae;Park, Jin-Hyung
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.291-297
    • /
    • 2008
  • The purpose of this study is to optimize a parallel-hole collimator for small gamma camera having the pixellated crystal array and evaluate the effect of crystal-collimator misalignment on the image quality using a simulation tool GATE (Geant4 Application for Tomographic Emission). The spatial resolution and sensitivity were measured for the various size of hexagonal-hole and matched square-hole collimators with a Tc-99m point source and the uniformity of flood image was estimated as a function of the angle between crystal array and collimator by misalignment. The results showed that the spatial resolution and sensitivity were greatly improved by using the matched collimator and the uniformity was reduced by crystal-collimator misalignment.

  • PDF

Olfactory Dysfunction in Chromium Exposed Workers (크롬 취급 근로자의 후각장애에 관한 조사연구)

  • Yu, Yeong-Jin;Ohm, Sang-Hwa;Lee, Jong-Tae;Yu, Byung-Chul;Jung, Kui-Oak;Cho, Kyu-Il;Pai, Ki-Tack
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.3 s.51
    • /
    • pp.678-689
    • /
    • 1995
  • Chromium is one of the representative toxic substance by occupational exposure which damage the mucosa of respiratory tract including nasal septal perforation. The aim of this study is to evaluate the effect of chromium exposure on olfactory function and to obtain the fundamental information about chromium exposure. The authors performed olfactory function test, laboratory tests and questionnaire interview on the subject of three groups, that is, two exposed groups and one nonexposed group from May 1 to June 30, 1994. Exposed group 1 was 15 male workers without nasal septal perforation, exposed group 2 was 15 male workers with nasal septal perforation among 103 workers in 22 chromium plating factories, and nonexposed group was 15 male medical students. The gathered informations were histories of chromium exposure, habits of smoking and alcohol drinking, the concentrations of chromium in serum and urine, and asparate aminotransferase(AST), alanine aminotransferase(ALT), gamma-glutamyl transferase, etc. Olfactory function was checked by T and T olfectometer using phenyl ethyl alcohol(material A), methyl cyclopentenolone(material B), iso-valeric acid(material C), $\gamma$-undecalactone(material D), skatole(material E) and the results were expressed by detection threshold(DT) and recognition threshold(RT). There was a significant difference between exposed groups and nonexposed group in A, B, C, D, E substances by DT and in A, B, C, D substances by RT(P<0.01). The degree of olfactory dysfunction was highest in the exposed group 2 and lowest in the nonexposed group in all five substances by DT and it was same in A B, D substances RT and the difference of RT and DT. As summary, olfactory dysfunction by chromium exposure was recognized and the degree of olfactory dysfunction was higher in the exposed group with nasal septal perforation. Therefore, it would be helpful to apply olfactory function test for the early detection of olfactory dysfunction, and this test would be considered as the basic tool within workers' compensation system.

  • PDF