• Title/Summary/Keyword: gamma particle

Search Result 245, Processing Time 0.025 seconds

Verification of Secondary Electron Generated by Head Screw in Gamma Knife Using Monte Carlo N-Particle Simulation

  • Kim, Heesoo;Lee, Jeong-Woo
    • Progress in Medical Physics
    • /
    • v.31 no.2
    • /
    • pp.29-34
    • /
    • 2020
  • Purpose: The interaction of various substances inserted into the human body and radiation can confirm the radiation enhancement effect. A Leksell frame inserted into the human body for gamma knife treatment will cause not only pain and inconvenience to the patient, but also additional exposure to the patient's normal tissues. In this study, we attempt to confirm the additional exposure caused by the interaction of the Leksell frame and thermoplastic mask, and 60Co used for gamma knife treatment. Methods: A 60Co energy of 1.17, 1.33 MeV is applied using Monte Carlo simulation, and fixation screws and thermoplastic mask are fabricated using aluminum and titanium alloy, and Carbon compounds. Results: Results show a dose enhancement of up to 396.27% higher compared with that without a Leksell frame and up to 391.25% in thermoplastic mask. Conclusions: Hence, appropriate treatment methods and materials must be used to reduce additional exposure to normal tissues.

Prediction of Maximum Dry Unit Weight of Sandy Soils From Grain-Size Distribution Parameters (입도분포계수를 이용한 사질토의 최대건조단위중량 예측)

  • Song, Young-Woo;Jin, Myung-Sub;Hong, Ki-Nam
    • International Journal of Highway Engineering
    • /
    • v.6 no.3 s.21
    • /
    • pp.55-64
    • /
    • 2004
  • Maximum dry unit weight, ${\gamma}_{dmax}$, is the most important engineering properties for subgrade soil. Existing models to predict ${\gamma}_{dmax}$ containing many parameters, seem to be rather complex. This paper presents new simple models to predict ${\gamma}_{dmax}$. for sandy soils, A number of sieve analysis and compaction tests for 36 types of sands were conducted to develop the regression-based models. Parameters used to estimate ${\gamma}_{dmax}$ are both the geometric mean and geometric standard deviation of the soils, or the particle-size distribution curve parameters. Maximum dry unit weights predicted by the models are in good agreement with the laboratory measurements for the soil samples obtained at 16 locations within the Korea.

  • PDF

A Study on the Optical Properties of γ-Fe2O3 Nano Particles (γ-Fe2O3 nano 입자의 광학적 특성에 관한 연구)

  • Lee, Kwon-Jai;An, Jeung-Hee;Shin, Jae-Soo;Kim, Chang-Man;Ozaki, Hajime;Koh, Jae-Gui
    • Korean Journal of Materials Research
    • /
    • v.16 no.12
    • /
    • pp.739-742
    • /
    • 2006
  • The ${\gamma}-Fe_2O_3$ nano particles in the size range of $5{\sim}30$ nm were prepared by a chemical coprecipitation method. The nano particles were coated with 2nd surfactants for obtaining the water-based. The size effect of ${\gamma}-Fe_2O_3$ nano particles for the ultraviolet protection was investigated. The variation of the UV-Vis transmittance spectra as a function of wavelength for a ${\gamma}-Fe_2O_3$ nano particles were showed red-shifted increase with the particle size. The protective effects of UVA onset at near 469, 494, 591 nm for a particle size of 8.7, 9.1 and 12 nm. It is shown that the ${\gamma}-Fe_2O_3$ nano particles was good materials for protect of UV.

Comparison of nano/micro lead, bismuth and tungsten on the gamma shielding properties of the flexible composites against photon in wide energy range (40 keV-662 keV)

  • Asgari, Mansour;Afarideh, Hossein;Ghafoorifard, Hassan;Amirabadi, Eskandar Asadi
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.4142-4149
    • /
    • 2021
  • In the radiation protection application, the metal-polymer composites have been developed for their radiation shielding properties. In this research, the elastomer composites doped by 10 ㎛ and 100nm size of lead, bismuth and tungsten particles as filler with 30 and 60 wt percentages were prepared. To survey the shielding properties of the polymer composites using gamma-ray emitted from 152Eu and 137Cs sources, the gamma flux was measured by using NaI(Tl) detector, then the linear attenuation coefficient was calculated. Also, the Monte Carlo simulation (MCs) method was used. The results showed a direct relationship between the linear attenuation coefficients of the absorbent and filler ratio. Also, the decrease in the particle size of the shielding material in each weight percentage improved the radiation shielding features. When the dimension of the particles was in the order of nano-size, more attenuation was achieved. At low energies used for medical diagnostic X-ray applications due to the predominance of the photoelectric effect, bismuth and lead were suitable selection as filler.

Detection of Tobamoviruses and Survey on Contamination Rate in Commercial Pepper Seeds Using Gelatin Particle Agglutination Test (젤라틴입자응집반응법을 이용한 국내 시판 고추종자의 Tobamovirus 검출 및 오염률 조사)

  • 한정헌;장태호;이철호;김영호;나용준
    • Research in Plant Disease
    • /
    • v.7 no.3
    • /
    • pp.170-174
    • /
    • 2001
  • Gelatin particle agglutination test (GPAT) was optimized for detection of Tobamovirus and contamination of the virus in commercial pepper seeds was evaluated. The optimum concentration of ${\gamma}$-globulin G, specific to tobacco mosaic virus pepper strain, was 100 ug/ml. The sensitivity of GPAT for the detection of Tobamovirus in pepper seeds was as high as enzyme-linked immunosorbent and dot immunoblotting assays. Optimum dilution ranges of the seed extract for GPAT was 5-25 folds. Using the optimized GPAT with above conditions, the rate of Tobamovirus contamination in seeds was turned out to be average of 79.1%.

  • PDF

Design and Fabrication of CLYC-Based Rotational Modulation Collimator (RMC) System for Gamma-Ray/Neutron Dual-Particle Imager

  • Kim, Hyun Suk;Lee, Jooyub;Choi, Sanghun;Bang, Young-bong;Ye, Sung-Joon;Kim, Geehyun
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.3
    • /
    • pp.112-119
    • /
    • 2021
  • Background: This work aims to develop a new imaging system based on a pulse shape discrimination-capable Cs2LiYCl6:Ce (CLYC) scintillation detector combined with the rotational modulation collimator (RMC) technique for dual-particle imaging. Materials and Methods: In this study, a CLYC-based RMC system was designed based on Monte Carlo simulations, and a prototype was fabricated. Therein, a rotation control system was developed to rotate the RMC unit precisely, and a graphical user interface-based software was also developed to operate the data acquisition with RMC rotation. The RMC system was developed to allow combining various types of collimator masks and detectors interchangeably, making the imaging system more versatile for various applications and conditions. Results and Discussion: Operational performance of the fabricated system was studied by checking the accuracy and precision of the collimator rotation and obtaining modulation patterns from a gamma-ray source repeatedly. Conclusion: The prototype RMC system showed reliability in its mechanical properties and reproducibility in the acquisition of modulation patterns, and it will be further investigated for its dual-particle imaging capability with various complex radioactive source conditions.

Statistical Analysis of Synthesis of Gamma-alumina (γ-Al2O3) Nanoparticles Using Reverse Micelles (역미셀을 이용한 감마-알루미나 나노입자 합성에 대한 통계적 분석)

  • Lee, Kil Woo;Yoo, Kye Sang
    • Applied Chemistry for Engineering
    • /
    • v.28 no.3
    • /
    • pp.351-354
    • /
    • 2017
  • An experimental design method was used to optimize the synthesis of gamma-alumina with a superior thermal stability using the reverse micelle method. First, twelve experimental conditions were derived by using the mixture design method to optimize conditions for the ratio of surfactant, water and oil, which are main factors in the synthesis process. When the particles synthesized by reverse micelle method were calcined at $900^{\circ}C$ under the designed condition, they all had gamma-alumina crystal structure although there were differences in particle sizes. The coefficient of determination of the second-order regression model using the derived experimental results was 93.68% and the P-value was 0.002. The synthesis conditions forgamma-alumina with various particle sizes were presented using surface and contour lines. As a result, it was calculated that the smallest particle size of about 2.8 nm was synthesized when the ratio of surfactant/water/oil was 0.3450/0.0729/0.5821.

A novel radioactive particle tracking algorithm based on deep rectifier neural network

  • Dam, Roos Sophia de Freitas;dos Santos, Marcelo Carvalho;do Desterro, Filipe Santana Moreira;Salgado, William Luna;Schirru, Roberto;Salgado, Cesar Marques
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2334-2340
    • /
    • 2021
  • Radioactive particle tracking (RPT) is a minimally invasive nuclear technique that tracks a radioactive particle inside a volume of interest by means of a mathematical location algorithm. During the past decades, many algorithms have been developed including ones based on artificial intelligence techniques. In this study, RPT technique is applied in a simulated test section that employs a simplified mixer filled with concrete, six scintillator detectors and a137Cs radioactive particle emitting gamma rays of 662 keV. The test section was developed using MCNPX code, which is a mathematical code based on Monte Carlo simulation, and 3516 different radioactive particle positions (x,y,z) were simulated. Novelty of this paper is the use of a location algorithm based on a deep learning model, more specifically a 6-layers deep rectifier neural network (DRNN), in which hyperparameters were defined using a Bayesian optimization method. DRNN is a type of deep feedforward neural network that substitutes the usual sigmoid based activation functions, traditionally used in vanilla Multilayer Perceptron Networks, for rectified activation functions. Results show the great accuracy of the DRNN in a RPT tracking system. Root mean squared error for x, y and coordinates of the radioactive particle is, respectively, 0.03064, 0.02523 and 0.07653.

Influence of constraint MgO deposition onto phosphors on luminance properties in AC Plasma Display Panels

  • Jeoung, Jin-Man;OH, P.Y.;Moon, M.W.;Lee, J.H.;Jeong, J.E.;Lee, H.J.;Han, Y.K.;Lee, S.B.;Jeong, S.H.;Yoo, C.K.;Yoo, N.R.;Choi, E.H.;Ko, B.D.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1215-1217
    • /
    • 2005
  • One of the important problems in recent AC-PDP technology is the image sticking. In this research, we have investigated the PDP cell with constraint deposition MgO on phosphor, the electrical and optical properties in the PDP cell were examined. Also, we have investigated the correlation with image sticking and degraded MgO protective layer, phosphor in AC-PDP. As a result, we measured the secondary electron emission coefficient ${\gamma}$, discharge characteristics and Brightness for the constraint degraded phosphor are compared with those of nondegraded phosphor.

  • PDF