• 제목/요약/키워드: gamma model

검색결과 1,205건 처리시간 0.026초

The Effects of Zingiber officinale Roscoe Extracts on Mouse $IFN-{\gamma}$ and IL-10 Production (생강 추출물 투여가 전구염증성 사이토카인 $IFN-{\gamma}$와 항염증성 사이토카인 IL-10 분비량에 미치는 영향)

  • Ryu, Hye-Sook
    • The Korean Journal of Food And Nutrition
    • /
    • 제20권3호
    • /
    • pp.259-264
    • /
    • 2007
  • Ginger(Zingiber officinale Roscoe) has been used as a raw material in many various traditional preparations since the ancient times. As a component of traditional health products, ginger is known to be effective as an appetite enhancer, and has anti-cold and anti-inflammatory activities. This study was performed to investigate the immunomodulative effects of Zingiber officinale Roscoe in mice, using ex vivo experiments. In order to elucidate ginger's immunomodulative effects of Ginger, water extracts were orally administered to mice, and isolated macrophages were used as the experimental model. To identify the ex vivo effects, six to seven week old Balb/c mice were fed a chow diet ad libitum and the ginger water extracts were administered orally every other day for two or four weeks at two different concentrations(50 and 500 mg/kg b.w.). The results show that IL-IO and $IFN-{\gamma}$ were detected in the 500 mg/kg b.w. supplemented group with LPS stimulation in all cases. Also, the $IFN-{\gamma}$ /IL-10 ratio ranged from 3~5 with mitogen stimulation such as Con A and LPS. In conclusion, this study suggests that ginger extracts may enhance the immune function by regulating the cytokine(IL-10 and $IFN-{\gamma}$) production capacity of activated macrophages in mice.

A GPU-based point kernel gamma dose rate computing code for virtual simulation in radiation-controlled area

  • Zhihui Xu;Mengkun Li;Bowen Zou;Ming Yang
    • Nuclear Engineering and Technology
    • /
    • 제55권6호
    • /
    • pp.1966-1973
    • /
    • 2023
  • Virtual reality technology has been widely used in the field of nuclear and radiation safety, dose rate computing in virtual environment is essential for optimizing radiation protection and planning the work in radioactive-controlled area. Because the CPU-based gamma dose rate computing takes up a large amount of time and computing power for voxelization of volumetric radioactive source, it is inefficient and limited in its applied scope. This study is to develop an efficient gamma dose rate computing code and apply into fast virtual simulation. To improve the computing efficiency of the point kernel algorithm in the reference (Li et al., 2020), we design a GPU-based computing framework for taking full advantage of computing power of virtual engine, propose a novel voxelization algorithm of volumetric radioactive source. According to the framework, we develop the GPPK(GPU-based point kernel gamma dose rate computing) code using GPU programming, to realize the fast dose rate computing in virtual world. The test results show that the GPPK code is play and plug for different scenarios of virtual simulation, has a better performance than CPU-based gamma dose rate computing code, especially on the voxelization of three-dimensional (3D) model. The accuracy of dose rates from the proposed method is in the acceptable range.

Effect of Tocopherols and $\beta$-Carotene on the Oxidation of Linoleic Acid Mixture in the Solid Model System (리놀레산 함유 고형 모델시스템의 산화에 미치는 토코페롤 및 베타 카로틴의 영향)

  • Kim, Myung;Rhee, Sook-Hee;Cheigh, Hong-Sik
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • 제24권1호
    • /
    • pp.67-73
    • /
    • 1995
  • Effects of tocopherols and $\beta$-carotene on the oxidation of the solid model system of a free fatty acid mixture (64.5% of linolic acid ; 26.4% of oleic acid ; 5.0% of palmitic acid) with tocopherols and $\beta$-carotene were studied. $\alpha$-tocopherol revealed an antioxidant activity at the concentration below 0.05%, however, it showed a prooxidant activity when the concentration was higher than 0.05%. The antioxidant activity of ${\gamma}$ -tocopherol was not affected by the concentrations in the range of 0.01~0.10% in the model and ${\gamma}$-tocopherol showed higher antioxidant activity than that of $\alpha$-tocopherol. It seemed that $\alpha$-tocopherol was unstable compared to ${\gamma}$-tocopherol during oxidation. $\beta$-carotene showed a weak antioxidative activity at the initial stage of this system while $\beta$-carotene showed a prooxidant activity in the presence of tocopherol. $\beta$ -carotene was highly susceptible to autoxidative degradation during oxidation.

  • PDF

A comparative study on applicability and efficiency of machine learning algorithms for modeling gamma-ray shielding behaviors

  • Bilmez, Bayram;Toker, Ozan;Alp, Selcuk;Oz, Ersoy;Icelli, Orhan
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.310-317
    • /
    • 2022
  • The mass attenuation coefficient is the primary physical parameter to model narrow beam gamma-ray attenuation. A new machine learning based approach is proposed to model gamma-ray shielding behavior of composites alternative to theoretical calculations. Two fuzzy logic algorithms and a neural network algorithm were trained and tested with different mixture ratios of vanadium slag/epoxy resin/antimony in the 0.05 MeV-2 MeV energy range. Two of the algorithms showed excellent agreement with testing data after optimizing adjustable parameters, with root mean squared error (RMSE) values down to 0.0001. Those results are remarkable because mass attenuation coefficients are often presented with four significant figures. Different training data sizes were tried to determine the least number of data points required to train sufficient models. Data set size more than 1000 is seen to be required to model in above 0.05 MeV energy. Below this energy, more data points with finer energy resolution might be required. Neuro-fuzzy models were three times faster to train than neural network models, while neural network models depicted low RMSE. Fuzzy logic algorithms are overlooked in complex function approximation, yet grid partitioned fuzzy algorithms showed excellent calculation efficiency and good convergence in predicting mass attenuation coefficient.

A(Q, r) Spare-Part Inventory Model with Gamma Leadtime

  • Park, Young-Taek;Park, Won-Jae;Hur, Jun
    • Journal of Korean Society for Quality Management
    • /
    • 제24권1호
    • /
    • pp.44-49
    • /
    • 1996
  • This paper deals with a (Q, r) spare-part inventory model with gamma leadtime. In the model, if the inventory level falls to a reorder point r, a replenishment order quantity Q is ordered. Assumming that the number of operating units is one and the lifetime of a unit follows an exponential distribution, we derive the expected cost rate and suggest a procedure to obtain the optimal pair of (Q, r) minimizing the cost rate. A numerical example is presented to explain the model.

  • PDF

Accuracy Measures of Empirical Bayes Estimator for Mean Rates

  • Jeong, Kwang-Mo
    • Communications for Statistical Applications and Methods
    • /
    • 제17권6호
    • /
    • pp.845-852
    • /
    • 2010
  • The outcomes of counts commonly occur in the area of disease mapping for mortality rates or disease rates. A Poisson distribution is usually assumed as a model of disease rates in conjunction with a gamma prior. The small area typically refers to a small geographical area or demographic group for which very little information is available from the sample surveys. Under this situation the model-based estimation is very popular, in which the auxiliary variables from various administrative sources are used. The empirical Bayes estimator under Poissongamma model has been considered with its accuracy measures. An accuracy measure using a bootstrap samples adjust the underestimation incurred by the posterior variance as an estimator of true mean squared error. We explain the suggested method through a practical dataset of hitters in baseball games. We also perform a Monte Carlo study to compare the accuracy measures of mean squared error.

A fast gamma-ray dose rate assessment method for complex geometries based on stylized model reconstruction

  • Yang, Li-qun;Liu, Yong-kuo;Peng, Min-jun;Li, Meng-kun;Chao, Nan
    • Nuclear Engineering and Technology
    • /
    • 제51권5호
    • /
    • pp.1436-1443
    • /
    • 2019
  • A fast gamma-ray dose rate assessment method for complex geometries based on stylized model reconstruction and point-kernel method is proposed in this paper. The complex three-dimensional (3D) geometries are imported as a 3DS format file from 3dsMax software with material and radiometric attributes. Based on 3D stylized model reconstruction of solid mesh, the 3D-geometrical solids are automatically converted into stylized models. In point-kernel calculation, the stylized source models are divided into point kernels and the mean free paths (mfp) are calculated by the intersections between shield stylized models and tracing ray. Compared with MCNP, the proposed method can implement complex 3D geometries visually, and the dose rate calculation is accurate and fast.

A Determination of an Optimal Repair Number under Achieved Availability Constraint (성취가용도를 고려한 최적 수리횟수 결정모델에 관한 연구)

  • Na, In-Sung;Park, Myeong-Kyu
    • Journal of Applied Reliability
    • /
    • 제7권1호
    • /
    • pp.13-22
    • /
    • 2007
  • A preventive maintenance model, caller FNBM (${\alpha},{\delta},{\gamma}$) model, is proposed to decide an optimal repair number under achieved availability requirements (r) along with taking two types of failures (repairable or irrepairable) into account. In this model, the current system is replaced by a new one in case when it doesn't meet the achieved availability requirement, even though it is repairable failure; Othewise it is replaced in time of the first irrepairable failure. Assumed that the j-th failure is repairable with probability ${\alpha}_j$ minimal repairs are allowed for repairable failure between replacements. Expected cost rate for preventive maintenance model is developed using NHPP (Non - Homogeneous Poisson Process) in order to de term in the optimal number $n^*$, also numerical examples are shown in order to explain the proposed model. Since the proposed FNBM (${\alpha},{\delta},{\gamma}$) model includes Park FNBM model (1979) and Nakagawa FNBM (p) model (1983) m this proposed model is thought to be better than previous model, especially for weapon system which requires availability as primary parameter.

  • PDF

The Changes of P-glycoprotein Activity by Interferon-γ and Tumor Necrosis Factor-α in Primary and Immortalized Human Brain Microvascular Endothelial Cells

  • Lee, Na-Young;Rieckmann, Peter;Kang, Young-Sook
    • Biomolecules & Therapeutics
    • /
    • 제20권3호
    • /
    • pp.293-298
    • /
    • 2012
  • The purpose of this study was to investigate the modification of expression and functionality of the drug transporter P-glycoprotein (P-gp) by tumor necrosis factor-alpha (TNF-${\alpha}$) and interferon-gamma (IFN-${\gamma}$) at the blood-brain barrier (BBB). We used immortalized human brain microvessel endothelial cells (iHBMEC) and primary human brain microvessel endothelial cells (pHBMEC) as in vitro BBB model. To investigate the change of p-gp expression, we carried out real time PCR analysis and Western blotting. To test the change of p-gp activity, we performed rhodamin123 (Rh123) accumulation study in the cells. In results of real time PCR analysis, the P-gp mRNA expression was increased by TNF-${\alpha}$ or IFN-${\gamma}$ treatment for 24 hr in both cell types. However, 48 hr treatment of TNF-${\alpha}$ or IFN-${\gamma}$ did not affect P-gp mRNA expression. In addition, co-treatment of TNF-${\alpha}$ and IFN-${\gamma}$ markedly increased the P-gp mRNA expression in both cells. TNF-${\alpha}$ or IFN-${\gamma}$ did not influence P-gp protein expression whatever the concentration of cytokines or duration of treatment in both cells. However, P-gp expression was increased after treatments of both cytokines together in iHBMEC cells only compared with untreated control. Furthermore, in both cell lines, TNF-${\alpha}$ or IFN-${\gamma}$ induced significant decrease of P-gp activity for 24 hr treatment. And, both cytokines combination treatment also decreased significantly P-gp activity. These results suggest that P-gp expression and function at the BBB is modulated by TNF-${\alpha}$ or/and IFN-${\gamma}$. Therefore, the distribution of P-gp depending drugs in the central nervous system can be modulated by neurological inflammatory diseases.

Gamma Dosimetry and Clinical Application with $Al_2O_3$ Thermoluminescent Dosimeter ($Al_2O_3$ 열형광(熱螢光) 특성(特性)을 이용(利用)한 감마선(線)의 측정(測定) 및 임상응용(臨床應用))

  • Chu, Seong-Sil;Park, Chang-Yoon
    • Journal of Radiation Protection and Research
    • /
    • 제9권1호
    • /
    • pp.3-10
    • /
    • 1984
  • The properties of $Al_2O_3$ thermoluminescent phosphor have been observed to apply for gamma dosimetry in vivo. Glow peaks at 380, 420, 490 kelvin temperature with emission in the blue region have been detected and calculated as 1.4 eV the activation energy by means of heat response rising time method. Sensitization and supralinearity in $Al_2O_3$ phosphor could be consistently explained by the deep trap model. Studies of the thermoluminescence growth rate with gamma ray exposure showed linearly to $10^4$ Roentgen and then supralinear rate detected 1.2 power of exposure dose sensitization of $Al_2O_3$ is described five times more than TLD-100 and the fading time is shorter and then tried to apply for gamma dosimetry in vivo.

  • PDF