• Title/Summary/Keyword: gait cycle

Search Result 148, Processing Time 0.04 seconds

A 3D Posture Measuring and Display System for Hemiplegic Patients (편마비 환자를 위한 3차원 보행 자세 측정 및 디스플레이 시스템)

  • Hwang, Yong-Ha;Kim, Yong-Seok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.8
    • /
    • pp.119-127
    • /
    • 2014
  • TIn this paper, Hemiplegic patients have gait characteristics different from normal persons. This paper presents a posture measuring and display system reflecting their characteristics. Patients wear 3 sensor modules on thigh, calf and foot. To enhance measuring precision of each sensor module, 3D accelerometer and 3D gyroscope are combined. Gait posture is displayed in 3D by modeling thigh, calf and foot as connected 3D objects based on data of the sensor modules. For convenience in inspecting unusual gait posture of hemiplegic patients, any view angle of the 3D display can be selected. In addition, the current gait phase of RLA(Rancho Los Amigos) gait cycle is determined and displayed in real-time by utilizing the posture information, The phase sequence and duration of each phase can be used in evaluating gait quality of patients.

Effective Gait Imbalance Judgment Method based on Thigh Location (대퇴부 위치 기반 효과적인 보행 불균형 측정 방법)

  • Kim, Seojun;Kim, Yoohyun;Shim, Hyeonmin;Lee, Sangmin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.541-545
    • /
    • 2014
  • In this paper, the angle of the thighs that appear during walking condition to balance estimation to the left and right leg was occurred during normal walking. Get over to the limitations of gait analysis using image processing or foot pressure that was used a lot in the previous, the angle of the thigh were used for estimation of asymmetric gait. We implemented heathy five adult male to test targeting and gait and obtained cycle data from 10 times. For this research, Thigh-Angle measurement device were developed, and attached to in a position of $20^{\circ}$ for flexion and $15^{\circ}$ for extension to measure the angle of the thigh. Also, in order to verify the reliability of estimation of asymmetric gait using thigh-angle, it was compared with the result of asymmetric gait estimation using foot pressure. The results of this paper, using the thigh angle is the average of 16.84% higher than using pressure to accuracy of determine the gait imbalance.

Feasibility test for dynamic gait of quadruped walking robot (4각 보행로봇의 동적 걸음새 평가)

  • 김종년;홍형주;윤용산
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.6
    • /
    • pp.1455-1463
    • /
    • 1990
  • In this study the feasibility of a dynamic gait for a given quadruped walking robot is investigated through a computer simulation of the walking with certain drivings of the actuators. Two planar inverted pendulums are used to represent the dynamic model of the leg of the walking robot. It's gait motion is assumed to be periodic and symmetric between left and right sides only with half cycle delay. The dynamics of the walking robot is simplified by introducing two virtual legs to produce two planar inverted pendulums in two orthogonal planes and on the basis that certain legs in pair act as one. The feasibility of the dynamic gait motion is established from the following two necessary conditions:(1) The position and velocity of a foot must satisfy the stroke and velocity requirements.(2) The gait motion should be periodic without falling down. The gait feasibility test was applied to a walking robot design showing the specific acceptable speed range of the robot in trot. Also it showed that the higher body height may produce the faster trot gait.

Gait Recognition using Modified Motion Silhouette Image (개선된 움직임 실루엣 영상을 이용한 발걸음 인식에 관한 연구)

  • Hong Sung-Jun;Lee Hee-Sung;Oh Kyong-Sae;Kim Eun-Tai
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.16 no.3
    • /
    • pp.266-270
    • /
    • 2006
  • In this paper, we propose the human identification system based on Hidden Markov model using gait. Since each gait cycle consists of a set of continuous motion states and transition across states has probabilistic dependences, individual gait can be modeled using Hidden Markov model. We assume that individual gait consists of N discrete transitions and we propose gait feature representation, Modified Motion Silhouette Image (MMSI) to represent and recognize individual gait. MMSI is defined as a gray-level image and it provides not only spatial information but also temporal information. The experimental results show gait recognition performance of proposed system.

New Fluid Flow System for Simulation of Mechanical Loading to Bone Cells During Human Gait Cycle

  • Ahn, Jae-Mok
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.377-386
    • /
    • 2007
  • Mechanical loading to bone cells using simple sine wave or constant wave fluid flow has been widely used for in vitro experiments. Human gait is characterized by a complex loading to bones of lower extremities which results from a series of events consisting of heel strike, foot flat and push-off during the stance phase of the gait cycle. Telemetric force analyses have shown that human femora are subject to multiphasic loading. Therefore, it would be ideal if the physiologic loading conditions during human walking can be used for in vitro mechanotransduction studies. Here, for a mechanotransduction study, we develop it fluid flow system (FFS) in order to simulate human physiologic mechanicalloading on bone cells. The development methods of the FFS including the COR (Center for Orthopedic Research), monitor program are presented. The FFS could generate various multiphasic loading conditions of human gaits with output flow. Wall shear distribution was very uniform, with 81 % of the effective loading area of the culture on a glass slide. Our results demonstrated that the FFS, provide a new translational approach for unveiling molecular mechanotransduction pathways in bone cells.

Comparisons of Kinematic Factors and Stiffnesses of the Lower-limb Joints between Transfemoral Amputees and Normal Adults (대퇴절단자와 정상인 걸음걸이의 운동학적 요인과 발목관절 강성 비교)

  • Yi, Jae-Hoon;Lee, Jung-Ho;Hah, Chong-Ku
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.1
    • /
    • pp.77-83
    • /
    • 2013
  • The purpose of this study was to compare kinematic variables and stiffnesses of ankle joints between normal person and transfemoral amputee gait in order to develop or fit prosthetic leg. Twenty subjects (ten normal persons and ten transfemoral amputees) participated in this experiment, and walked three trials at a self-selected pace. The gait motions were captured with Vicon system and variables were calculated with Visual-3D. The velocity, stride length, stride width, cycle time, double limb support time and right swing time of gaits were statistically significant. Because coefficients of variability of normal persons on velocity, double limb support time and swing time were greater than transfemoral amputees, normal persons controlled these gait variables effectively. The stiffnesses of ankle joints were not statistically significant, but patterns of stiffnesses of ankle joints during three rockers were absolutely different. The negative correlations between stiffnesses of ankle joints and cycle time and swing time were presented. These differences suggest that developing and fitting prosthetic leg were demanded. Further studies should develop fitting program and simulator of prosthetic leg.

Three-Dimensional Video Analysis of the Gate Patterns in Normal Children and Hemiplegic Children with Cerebral Palsy (정상아와 편마비 뇌성마비아의 삼차원 보행분석)

  • Lee Jin-Hee;Bae Sung-Soo;Kim Chung-Sun
    • The Journal of Korean Physical Therapy
    • /
    • v.9 no.1
    • /
    • pp.127-145
    • /
    • 1997
  • The purpose of this study wa9 to analyse the gait patterns of two female children with hemiplegic cerebral palsy by using the three-dimensional video motion analysis technique. Case 1 has mild spastic hemiplegia on the right side while Case 3 has moderate spastic hemiplegia on the left side. A group of 10, normal female children of the same age(7-8 years old) were selected as the control group for comparison. Time and distance variables as well as the Center of Mass displacement, and the pelvic and joint motions in three anatomical planes were analysed for this purpose. The following observations were made through the analysis : Case 1 revealed an asymmetrical gait pattern in which the step length of the unaffected side was shorter than that of the affected side, which wan a result of the effort to minimize loading on the affected leg by shortening the swing phase of the unaffected leg. Case 1 scored similar phase ratios, cadence and walking velocity to the normal group. A slight posterior tilt of the pelvis was observed throughout the gait cycle. Less hip and knee flexion than the normal group was observed, and demonstrated hyperextension of the knee in the terminal stance phase. The main problem in case 1 originated from the insufficient dorsiflexion of the affected foot during the swing phase. Therefore, Case 1 has difficulty with foot clearance in the swing phase. Usually, this is compensated for by using exessive hip abduction and medial rotation in conjuction with trunk elevation as well as increased vortical displacement of the center of mass. Case 1 revealed a foot-flat initial contact pattern. Case 2 was characterized by a consistent retraction ef the affected aide of the body througout the gait cycle, As a result, an asymmetrical gait pattern with increased stance phase ratios of the unaffected side was observed. In spite of this the step lengths of both sieds were similar. Case 2 scored lower cadence and walking speed than the normal group with lower gait stability. The main problem in Case 2 originated from an excessive plantaflexion of the affected foot which, in turn, rebutted in high hip and knee flexion. Hyperextension of the knee was observed at mid-stance, and execessive anterior tilt of the pelvis throughout the gait cycle was noticed. A gait pattern with high hip abduction and medial circumduction was maintained for the stability in the stance phase and foot clearance in the swing phase. Case 2 revealed a forefoot-contact initial contact pattern.

  • PDF

Development of the Automatic Knee Joint Control System for a Knee-Ankle-Foot Orthosis Using an Electromechanical Clutch (전자-기계식 클러치를 이용한 장하지 보조기용 무릎관절 자동 제어 장치의 개발)

  • 이기원;강성재;김영호;조강희
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.4
    • /
    • pp.359-368
    • /
    • 2001
  • A new knee-ankle-foot-orthosis(KAFO) which uses an automatically-controlled electromechanical wrap spring clutch for the knee joint was developed in the present study. It was found that the output voltage from the foot switches of the developed KAFO was proportionally increased with respect to the applied load. The output voltage from the infrared sensor also decreased as the knee flexion angle increased. The knee joint system for the new KAFO weighs only 780g lighter than any other commercially available developed system. In addition, the solenoid reduces the reaction time for the automatic control of the knee joint. The static torque of the clutch was measured for three persons, and it satisfied the normal knee extension moment during the pre-swing. Three-dimensional gait analyses for three different gait patterns (normal gait, locked-knee gait, controlled-knee gait) from five normal subjects were conducted. Controlled-knee gait showed the maximum knee flexion angle of 40.56$\pm9.55^{\circ}$ and the maximum knee flexion moment of 0.20$\pm$0.07Nm/kg at similar periods in the normal gait. Our KAFO system satisfies both stability during stance phase and free knee flexion during the swing phase at the proper period during the gait cycle. Therefore, our KAFO system would be very useful in various low extremity orthotic applications.

  • PDF

The Effect of Using a Two Step Verbal Cue to a Visual Target above Eye Level on the Parkinsonian Gait (파킨슨병 환자 보행에서 눈 높이 위수준의 시작 목표에 대한 두 걸음 구두 암시의 효과)

  • Kim, Jong-Man;Ahn, Duk-Hyun;Choi, Woon-Sung
    • Physical Therapy Korea
    • /
    • v.1 no.1
    • /
    • pp.92-97
    • /
    • 1994
  • It is well known that visual cues can improve the motor performance of Parkinsonian patients. Previous laboratory studies have examined the effects of visual cueing to the floor. This case study examined the effects of using a visual cue above eye level on the gait of a Parkinsonian man. It was found that cueing the patient to a target above eye level while waking not only improved the kinematic parameters of the gait cycle but also facilitated a more functional gait pattern with re-intergration of arm swing, rhythm, heel strike and a more erect posture. Visual targeting above eye level may serve as an important clinical tool for physiotherapists treating Parkinsonian patients.

  • PDF

The Effect of Elastic Taping on the Quadriceps Femoris to the Gait Cycle (대퇴사두근에 대한 탄력테이핑 적용이 보행주기에 미치는 효과)

  • Jung, Byeong-Ok;Ma, Sang-Yeol;Park, Jae-Young
    • Journal of Korean Physical Therapy Science
    • /
    • v.15 no.2
    • /
    • pp.53-60
    • /
    • 2008
  • Background: The purpose of present study was to investigate the effect of quadriceps femoris taping in normal gait using 3D motion capture technique. Method: Twenty healthy volunteers, have no musculoskeletal problems, were recruited as subjects for this study. In experimental group, 10 males (mean age : 23.6${\pm}$.40) and 10 females (mean age : 21.3${\pm}$.36) were included. Methods of therapeutic taping that taping of patellar inferior and medial gliding and quadriceps. To obtain the dynamic data, we captured the motion of subject attached markers without taping during repeated gaits five times or more in 7 m Capture volume of gait analysis center. The result was obtained as a mean value in three times. After taping on quadriceps femoris, the same procedure was carried out. Statistical analyses were performed using statistical software packagess SPSS WIN 12.0(SPSS, Chicago, IL, USA). Differences were tested for statistical significance using paired t-test, independent t-test, chi-squared test for comparisons between the male and female. Results: The date of 20 subjects who carried out the whole experimental course were statistically analyzed. 1. gait velocity was showed that female group had more significantly increased than male group(p<.05). 2. step length was showed that female group had more significantly increased than male group(p<.05). 3. step width was showed that female group had more significantly increased than male group(p<.05). Conclusion: Elastic taping on quadriceps femoris promoted cadence, gait velocity, step length and step width in normal subject group.

  • PDF