• Title/Summary/Keyword: gadolinium

Search Result 329, Processing Time 0.028 seconds

The Properties of Beam Intensity Scanner (BInS) for Dose Verification in Intensity Modulated Radiation Therapy (방사선 세기 조절 치료에서 선량을 규명하는 데 사용된 BlnS System의 특성)

  • 박영우;박광열;박경란;권오현;이명희;이병용;지영훈;김근묵
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • Patient dose verification is one of the most Important responsibilities of the physician in the treatment delivery of radiation therapy. For the task, it is necessary to use an accurate dosimeter that can verify the patient dose profile, and it is also necessary to determine the physical characteristics of beams used in intensity modulated radiation therapy (IMRT) The Beam Intensity Scanner (BInS) System is presented for the dosimetric verification of the two dimensional photon beam. The BInS has a scintillator, made of phosphor Terbium-doped Gadolinium Oxysulphide (Gd$_2$O$_2$S:Tb), to produce fluorescence from the irradiation of photon and electron beams. These fluoroscopic signals are collected and digitized by a digital video camera (DVC) and then processed by custom made software to express the relative dose profile in a 3 dimensional (3D) plot. As an application of the BInS, measurements related to IWRT are made and presented in this work. Using a static multileaf collimator (SMLC) technique, the intensity modulated beam (IMB) is delivered via a sequence of static portals made by controlled leaves. Thus, when static subfields are generated by a sequence of abutting portals, the penumbras and scattered photons of the delivered beams overlap in abutting field regions and this results in the creation of “hot spots”. Using the BInS, inter-step “hot spots” inherent in SMLC are measured and an empirical method to remove them is proposed. Another major MLC technique in IMRT, the dynamic multileaf collimator (DMLC) technique, has different characteristics from SMLC due to a different leaf operation mechanism during the irradiation of photon and electron beams. By using the BInS, the actual delivered doses by SMLC and DMLC techniques are measured and compared. Even if the planned dose to a target volume is equal in our experimental setting, the actual delivered dose by DMLC technique is measured to be larger by 14.8% than that by SMLC, and this is due to scattered photons and contaminant electrons at d$_{max}$.

  • PDF

Determination of Electron Spin Relaxation Time of the Gadolinium-Chealted MRI Contrast Agents by Using an X-band EPR Technique (EPR을 통한 상자성 자기공명 조영제의 전자스핀 이완시간의 결정)

  • Sung-wook Hong;Yongmin Chang;Moon-jung Hwang;Il-su Rhee;Duk-Sik Kang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.27-33
    • /
    • 2000
  • Purpose: To determine the electronic spin relaxation times, $T_{le}$, of three commercially available Gd-chelated MR contrast agents, Gd-DTPA, Gd-DTPA-BMA and Gd-DOTA, using Electron Paramagnetic Resonance(EPR) technique. Material and Methods: The paramagnetic MR contrast agents, Gd-DTFA(Magnevist) , Gd-DTFA-BMA(OMNISCAN) and Gd-DOTA(Dotarem), were used for this study, The EPR spectra of these contrast agents, which were prepared 2:1 methanol/water solution, were obtained at low temperatures, from $-160^{\circ}C~20^{\circ}C$. The glassy-state EPR spectra for these contrast agents were then fitted by the simulation spectra generated with different zero-field splitting (ZFS) parameters by a computer simulation program 'GEN', which generates the EPR powder spectrum using a given ZFS in $3{\times}3$ tensor. Finally, the spin relaxation times of the contrast agents were then determined from the $T_{2e}$, D, and E values of the best simulation spectra using the McLachlan's theory of average relaxation rate. Results: The electronic transverse spin relaxation times, $T_{2e}'s$, of Gd-DTPA, Gd-DTPA-BMA and Gd-DOTA were 0.113ns, 0.147ns and 1.81ns respectively. The g-values were 1.9737, 1.9735 and 1.9830 and the electronic spin relaxation times, $T_{1e}'s$, were 18.70ns, 33.40ns and $1.66{\mu}s$, respectively. Conclusion: The results of these studies reconfirm that the paramagnetic MR contrast agents with larger ZFS parameters should have shorter $T_{1e}'s$. Among three contrast agents used for this study, Gd-DOTA chelated with cyclic ligand structure shows better electronic property then the others with linear structure. Thus, it is concluded that the exact determination of ZFS parameters is the important factor in evaluating relaxation enhancement effect of the agents and in developing new contrast agents.

  • PDF

Synthesis of Cyclen-Based Copper Complexes as a Potential Estrogen Receptor Ligand (에스트로젠 수용체 리간드로서 사이클렌을 기본 구조로 한 구리 착물의 합성)

  • Park, Jeong-Chan;Pandya, Darpan N.;Jeon, Hak-Rim;Lee, Sang-Woo;Ahn, Byeong-Cheol;Lee, Jae-Tae;Yoo, Jeong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.326-334
    • /
    • 2007
  • Purpose: The estrogen receptor (ER), which is over-expressed in ER-positive breast tumors, has been imaged by positron emission tomography (PET) using $[^{18}F]$ labeled estrogen ligands, especially $[^{18}F]FES$. However, $[^{18}F]$ has relatively short-lived half-life ($t_{1/2}$ =1.8 h) and the labeling yield of radio-fluorination is usually low compared with $^{64}Cu\;(t_{1/2}=12.7\;h)$. 1,4,7,10-tetraazacyclododecane (cyclen) is used to form stable metal complexes with copper, indium, gallium, and gadolinium. With these in mind, we prepared cyclen-based Cu complexes which mimic estradiol in aspect of two hydroxyl groups. Materials and Methods: 1.7-Protected cyclen, 1.7-bis (benzyloxycarbonyl)-cyclen was synthesized according to the reported procedure. After introducing two 4-benzyloxybenzyl groups at 4,10-positions, the benzyloxycarbonyl and benzyl groups were removed at the same time by hydrogenation on Pd/C to give 1,7-bis(4-hydroxybenzyl)-1,4,7,10-tetraazacyclododecane (1). Results: The prepared ligand 1 was fully characterized by $^1H,\;^{13}C$ NMR, and mass spectrometer. The synthesized ligand was reacted with copper chloride and copper perchlorate to give copper complexes $[Cu(1)]^{2+}2(CIO_4^-)\;and\;[Cu(1)Cl]^+Cl^-$ which were confirmed by high-resolution mass (FAB). Conclusion: We successfully synthesized a cyclen derivative of which two phenol groups are located on trans position of N-atoms. And, two Cu(ll) complexes of +2 and +1 overall charge, were prepared as a potential PET tracers for ER imaging.

Synthesis and Electrochemical Properties of (La0.6Sr0.4)(Co0.2Fe0.8)O3 cathode for SOFC on pH Control Using Modified Oxalate Method (Modified Oxalate Method 의해 합성한 SOFC용(La0.6Sr0.4)(Co0.2Fe0.8)O3 Cathode의 pH 변화에 따른 특성)

  • Lee, Mi-Jai;Choi, Byung-Hyun;Kim, Sei-Ki;Park, Sang-Sun;Lee, Kyung-Hee
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.4
    • /
    • pp.288-294
    • /
    • 2007
  • The LSCF cathode far Solid Oxide Fuel Cell was investigated to develop high performance unit cell at intermediate temperature by modified oxalate method with different electrolytes and different pH. The LSCF powders employed La, Sr, Co and Fe oxides, oxalic acid, ethanol and $NH_4OH$ solution were synthesized with pH controlled as 2, 6, 7, 8, 9 and 10 at $80^{\circ}C$ Single crystalline phase was obtained from pH $2{\sim}9$. on the other hand, $La_2O_3$ appeared from pH 10. Very fine powder with particle size of 50 nm was obtained at calcination temperature of $800^{\circ}C$ for 4 hours. LSCF cathode synthesized at pH 7 showed the highest electric conductivity in the temperature range of $600^{\circ}C$ to $900^{\circ}C$ its value was 950 S/cm at $900^{\circ}C$ Under same synthesis conditions, polarization resistance of each LSCF cathode was changed with different calcination temperatures. As-prepared powder presented 2.52, 1.54 and $2.58\;{\Omega}$ at $600^{\circ}C$ with ScSZ, 8Y-YSZ and GDC as its electrolyte respectively after calcination at $800^{\circ}C$ for 4 hours.

MR Imaging Findings of Uterine Cervical Adenocarcinoma (자궁경부 선암종의 자기공명영상 소견)

  • 김종철
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.113-119
    • /
    • 1998
  • Purpose : Because adenocarcinomas of the uterine cervix have lower 5-year survival rate than squamous cell carcinomas due to early lymph node metastasis and local extension, scrutiny of lymph node metastasis and local extension by radiologic examination is necessary in case of clinically diagnosed or suspected adenocarcinomas. The purpose of this study is to evaluate whether there are specific findings of these tumors, compared with squamous cell carcinomas, through the analysis of magnetic resonance (MR) imaging findings. Materials and Methods : Of 21 pathologically proven cervical adenocarcinomas, MR imaging findings of 18 tumors (histologic staging : two Ib, four IIa, two IIb, one IIIa, and one IIIb) were retrospectively analyzed and compared with those of 40 wquamous cell carcinoma in consecutive patients as a control group. T1-wetighted and fast spin echo T2-weighted images were obtained on the axial and sagittal planes, using a 1.5-T MR scanner. The largest diameter, location, signal intensity and degree of contrast enhancement contour, shape and longitudinal extent of the tumor and associated findings on MR image were analyzed. Results : The largest diameters of cervical adenocarcinomas ranged from 0.8 to 4.1 cm(mean, 2.2 cm). Of 18 adenocarcinomas, nine were of endocervical type. All adenocarcinomas were isointense to surrounding cervical stroma on T1-weighted images and hyperintense(homogeneous in ten, inhomogeneous in eight) on fast spin echo T2-weighted images. Adenocarcinomas enhanced on contrast study in all patients (homogeneous in six, inhomogeneous in 12 with hyperintese enhnacing rim in two). Eight adenocarcinomas had smooth contours and ten had irregular ones. The shape of adenocarcinoma was irregular in eight patients, barrel shape in six, papillary/polypod in three, and nodular in one. All adenocarcinomas involved lower half of the uterine cervix and six tumors extended up to the upper half. Pelvic lymph nodes of more than 1.5cm in diameter in two adenocarcinomas pateints and no detectable small pelvic lymph nodes on MR imaging in one patient were pathologically positive. Hydrometra was associated in two adenocarcinomas patients, and hematometra in one patient. Compared with squamous cell carcinomas, more frequent MR findings of endocervical type and barrel shape in cervical adenocarcinomas were statistically significant. Conclusion : Cervical adenocarcinomas had more frequent MR findings of endocervical type and barrel shape, compared with wquamous cell carcinomas. Adenocarcinoma of the uterine cervix may be suspected on MR imaging, when a cervical carcinoma is of barrel shape along the endocervical canal and tends to involve lymth nodes in earlier stages.

  • PDF

Glomus Tumor in Soft Tissue (연부 조직에 발생한 사구종)

  • Kim, Do-Yeon;Lee, Soo-Hyun;Kim, Min-Ju;Shin, Kyoo-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.15 no.1
    • /
    • pp.34-43
    • /
    • 2009
  • Purpose: Glomus tumors are rare benign vascular tumors, usually located in the skin or soft tissue of extremities. Approximately 30-50% of glomus tumors occur in subungal area, but glomus tumors have been described in every location even where glomus bodies are not or rarely present. The purpose of this study was to identify clinical, histologic and MRI characteristics of soft tissue glomus tumor. Materials and Methods: Between 1993 and 2008, eight patients underwent surgery of soft tissue Glomus tumor at our institution. Exclusion criteria were patients with Glomus tumors in digits, stomach, trachea and glomus tympanicum. We analyzed medical records, interviews, physical examinations, MR findings and histolocial types retrospectively. Results: There were four men and four women. The mean age was fourty-seven years. The mean prevalence time was eight-point-nine years. In the classic triad of symptoms, all eight patients had pain and tenderness. Two patients complained of cold sensitivity. Two showed skin color changes. After surgery, two showed symptom improvement (VAS $9^{\circ}{\rightarrow}8$, $8^{\circ}{\rightarrow}5$) and?six showed complete disappearance of symptoms. Slightly symptom improvemented (VAS $9^{\circ}{\rightarrow}8$) one had additional surgery two times after first surgery due to relapse/remaining Glomus tumor. The mean size was 13.9 mm. In histology, six were 'solid glomus tumor', one was a mixture of 'solid glomus tumor' and 'lomangioma' and one was 'malignant glomus tumor'. MR findings showed isointense signal on T1 image, high signal on T2 image and strong enhancement on the Gadolinium enhanced image. Conclusion: Glomus tumor has low recurrence rate and malignant change, rapid diagnosis and surgical excision is critical in treatment to prevent unnecessary pain of patient.

  • PDF

주사용 요오드화 조영제 및 MRI용 가돌리늄 조영제 유해 반응에 대한 한국 임상진료지침: 개정된 임상적 합의 및 권고안(2022년 제3판)

  • Se Won Oh;So Young Park;Hwan Seok Yong;Young Hun Choi;Min Jae Cha;Tae Bum Kim;Ji Hyang Lee;Sae Hoon Kim;Jae Hyun Lee;Gyu Young Hur;Jae Yeon Hwang;Sejoong Kim;Hyo Sang Kim;Ji Young Ryu;Miyoung Choi;Chi-Hoon Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.254-264
    • /
    • 2022
  • The Korean Society of Radiology and Medical Guidelines Committee amended the existing 2016 guidelines to publish the "Korean Clinical Practice Guidelines for Adverse Reactions to Iodide Contrast for Injection and Gadolinium Contrast for MRI: The Revised Clinical Consensus and Recommendations (2022 Third Edition)." Expert members recommended and approved by the Korean Society of Radiology, the Korean Academy of Asthma, Allergy and Clinical Immunology, and the Korean Nephrology Society participated together. According to the expert consensus or systematic literature review, the description of the autoinjector and connection line for the infection control while using contrast medium, the acute adverse reaction, and renal toxicity to iodized contrast medium were modified and added. We would like to introduce the revised contents.

Quantitative Evaluation of Liver Fibrosis on T1 Relaxometry in Comparison with Fibroscan (Fibroscan과 비교를 통한 T1 MR Relaxometry를 이용한 간섬유화의 정량적 평가)

  • Byeong Hak Sim;Suk Hee Heo;Sang Soo Shin;Seong Beom Cho;Yong Yeon Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.2
    • /
    • pp.365-378
    • /
    • 2020
  • Purpose This study was performed to determine whether the T1 relaxation time of gadoxetic acid-enhanced liver MR imaging is useful for detecting and staging liver fibrosis in patients with chronic liver disease. Materials and Methods One hundred and three patients with suspected focal liver lesion underwent MR imaging and Fibroscan. Fibroscan was chosen as the reference standard for classifying liver fibrosis. T1 relaxation times were acquired before (preT1), 20 minutes after (postT1) contrast administration, and reduction rate of T1 relaxation time (rrT1) on transverse 3D VIBE (volumetric interpolated breath-hold examination) sequence using 3T MR imaging. The optimal cut-off values for the fibrosis staging were determined with ROC analysis. Results PreT1 and postT1 increased and rrT1 decreased constantly with increasing severity of liver fibrosis according to the METAVIR score (F0-F4). There were statistically significant differences between F2 and F3 in preT1 (F2, 836.0 ± 74.7 ms; F3, 888.6 ± 77.5 ms, p < 0.05) and between F3 and F4 in postT1 (F3, 309.0 ± 80.2 ms; F4, 406.6 ± 147.7 ms, p < 0.05) and rrT1 (F3, 65.4 ± 7.7%; F4, 57.3 ± 11.4%, p < 0.05). ROC analysis revealed that combination test (preT1 + postT1) was the best test for predicting liver fibrosis. Conclusion PreT1 and postT1 increased constantly with increasing severity of liver fibrosis. T1 mapping in gadoxetic acid-enhanced liver MR imaging could be a helpful complementary sequence to determine the liver fibrosis stage.

[ $Gd(DTPA)^{2-}$ ]-enhanced, and Quantitative MR Imaging in Articular Cartilage (관절연골의 $Gd(DTPA)^{2-}$-조영증강 및 정량적 자기공명영상에 대한 실험적 연구)

  • Eun Choong-Ki;Lee Yeong-Joon;Park Auh-Whan;Park Yeong-Mi;Bae Jae-Ik;Ryu Ji Hwa;Baik Dae-Il;Jung Soo-Jin;Lee Seon-Joo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.100-108
    • /
    • 2004
  • Purpose : Early degeneration of articular cartilage is accompanied by a loss of glycosaminoglycan (GAG) and the consequent change of the integrity. The purpose of this study was to biochemically quantify the loss of GAG, and to evaluate the $Gd(DTPA)^{2-}$-enhanced, and T1, T2, rho relaxation map for detection of the early degeneration of cartilage. Materials and Methods : A cartilage-bone block in size of $8mm\;\times\;10mm$ was acquired from the patella in each of three pigs. Quantitative analysis of GAG of cartilage was performed at spectrophotometry by use of dimethylmethylene blue. Each of cartilage blocks was cultured in one of three different media: two different culture media (0.2 mg/ml trypsin solution, 1mM Gd $(DTPA)^{2-}$ mixed trypsin solution) and the control media (phosphate buffered saline (PBS)). The cartilage blocks were cultured for 5 hrs, during which MR images of the blocks were obtained at one hour interval (0 hr, 1 hr, 2 hr, 3 hr, 4 hr, 5 hr). And then, additional culture was done for 24 hrs and 48 hrs. Both T1-weighted image (TR/TE, 450/22 ms), and mixed-echo sequence (TR/TE, 760/21-168ms; 8 echoes) were obtained at all times using field of view 50 mm, slice thickness 2 mm, and matrix $256\times512$. The MRI data were analyzed with pixel-by-pixel comparisons. The cultured cartilage-bone blocks were microscopically observed using hematoxylin & eosin, toluidine blue, alcian blue, and trichrome stains. Results : At quantitation analysis, GAG concentration in the culture solutions was proportional to the culture durations. The T1-signal of the cartilage-bone block cultured in the $Gd(DTPA)^{2-}$ mixed solution was significantly higher ($42\%$ in average, p<0.05) than that of the cartilage-bone block cultured in the trypsin solution alone. The T1, T2, rho relaxation times of cultured tissue were not significantly correlated with culture duration (p>0.05). However the focal increase in T1 relaxation time at superficial and transitional layers of cartilage was seen in $Gd(DTPA)^{2-}$ mixed culture. Toluidine blue and alcian blue stains revealed multiple defects in whole thickness of the cartilage cultured in trypsin media. Conclusion : The quantitative analysis showed gradual loss of GAG proportional to the culture duration. Microimagings of cartilage with $Gd(DTPA)^{2-}$-enhancement, relaxation maps were available by pixel size of $97.9\times195\;{\mu}m$. Loss of GAG over time better demonstrated with $Gd(DTPA)^{2-}$-enhanced images than with T1, T2, rho relaxation maps. Therefore $Gd(DTPA)^{2-}$-enhanced T1-weighted image is superior for detection of early degeneration of cartilage.

  • PDF