• Title/Summary/Keyword: g-factor

Search Result 5,003, Processing Time 0.029 seconds

Analysis of Subthreshold Behavior of FinFET using Taurus

  • Murugan, Balasubramanian;Saha, Samar K.;Venkat, Rama
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.1
    • /
    • pp.51-55
    • /
    • 2007
  • This paper investigates the subthreshold behavior of Fin Field Effect Transistor (FinFET). The FinFET is considered to be an alternate MOSFET structure for the deep sub-micron regime, having excellent device characteristics. As the channel length decreases, the study of subthreshold behavior of the device becomes critically important for successful design and implementation of digital circuits. An accurate analysis of subthreshold behavior of FinFET was done by simulating the device in a 3D process and device simulator, Taurus. The subthreshold behavior of FinFET, was measured using a parameter called S-factor which was obtained from the $In(I_{DS})\;-\;V_{GS}$ characteristics. The value of S-factor of devices of various fin dimensions with channel length $L_g$ in the range of 20 nm - 50 nm and with the fin width $T_{fin}$ in the range of 10 nm - 40 nm was calculated. It was observed that for devices with longer channel lengths, the value of S-factor was close to the ideal value of 60 m V/dec. The S-factor increases exponentially for channel lengths, $L_g\;<\;1.5\;T_{fin}$. Further, for a constant $L_g$, the S factor was observed to increase with $T_{fin}$. An empirical relationship between S, $L_g$ and $T_{fin}$ was developed based on the simulation results, which could be used as a rule of thumb for determining the S-factor of devices.

Theoretical gravity studies on roles of convection in crystal growth of $Hg_2Cl_2$-Xe by physical vapor transport under normal and high gravity environments

  • Kim, Geug-Tae;Kwon, Moo-Hyun
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.3
    • /
    • pp.107-115
    • /
    • 2009
  • Particular interest in the role of convection in vapor crystal growth has arisen since some single crystals under high gravity acceleration of $10g_0$ appear considerably larger than those under normal gravity acceleration ($1g_0$). For both ${\Delta}T=60\;K$ and 90 K, the mass flux increases by a factor of 3 with increasing the gravity acceleration from $1g_0$ up to $10g_0$. On the other hand, for ${\Delta}T=30\;K$, the flux is increased by a factor of 1.36 for the range of $1g_0{\leq}g{\leq}10g_0$. The maximum growth rates for $1g_0$, $4g_0$, $10g_0$ appear approximately in the neighborhood of y = 0.5, and the growth rates shows asymmetrical patterns, which indicate the occurrence of either one single or more than one convective cell. The maximum growth rate for $10g_0$ is nearly greater than that for $1g_0$ by a factor of 2.0 at $P_B=20\;Torr$. For three different gravity levels of $1g_0$, $4g_0$ and $10g_0$, the maximum growth rates are greater than the minimum rates by a factor of nearly 3.0, based on $P_B=20\;Torr$. The mass flux increases with increasing the gravity acceleration, for $1g_0{\leq}g_y{\leq}10g_0$, and decreases with increasing the partial pressure of component B, xenon (Xe), $P_B$. The $|U|_{max}$ is directly proportional to the gravity acceleration for $20\;Torr{\leq}P_B{\leq}300\;Torr$. As the partial pressure of $P_B$ (Torr) decreases from 300 Torr to 20 Torr, the slopes of the $|U|_{max}s$ versus the gravity accelerations increase from 0.1 sec to 0.17 sec. The mass flux of $Hg_2Cl_2$ is exponentially decayed with increasing the partial pressure of component B, $P_B$ (Torr) from 20 Torr up to 300 Torr.

Antigenicity Studies of M3S Tumor Necrosis Factor-$\alpha$(M3S TNF), a TNF Mutein (M3S Tumor Necrosis Factor-$\alpha$(M3S TNF)의 항원성)

  • 한형미;손경희;오현정;최경백;정승태;선우연;신남규;신항철
    • Toxicological Research
    • /
    • v.13 no.3
    • /
    • pp.203-208
    • /
    • 1997
  • The antigenic potential of M3S tumor necrosis factor-$\alpha$(M3S TNF), which is a mutated form of TNF(TNF mutein) designed to reduce adverse effects of wild type human TNF, was investigated in the present study. The antigenicity of M3S TNF was examined by conducting active systemic anaphylaxis (ASA) test in guinea pigs, heterologous(mouse-rat) passive cutaneous anaphylaxis(PCA) test and passive hemagglutination(PHA) test. The experimental animals were divided into low, medium, high and the highest dose groups and the groups with or without immunoadjuvant, sensitized according to the appropriate schedule and challenged. In ASA test, when challenged with 120 $\mu\textrm{g}$ /animal, moderate to severe positive anaphylactic responses were observed in groups sensitized with 12 $\mu\textrm{g}$ /animal, 120 $\mu\textrm{g}$ /animal and 120 $\mu\textrm{g}$ /animal+Freund's complete adjuvant. In PCA test, positive responses were observed in the group sensitized with the highest dose emulsified with an alum(12 $\mu\textrm{g}$ /animal+alum). In PHA test, positive responses were observed in the group sensitized with 3 $\mu\textrm{g}$ /animal emulsified with an alum. All the other groups in each experiment showed negative responses. Based on these results, M3S TNF is considered to have some antigenic potential.

  • PDF

Predicting the Capability Curve of Cellulose Acetate Filters (셀롤로오스 아세테이트 필터의 특성곡선 예측)

  • Kim Soo-HO;Lim Sung-Jin;Kim Chung-Ryul;Shin Chang-Ho;Rhee Moon-Soo;Kim Jong-Yeol
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.27 no.2
    • /
    • pp.163-170
    • /
    • 2005
  • A theoretical model for predicting the capability curve of cellulose acetate filter is derived. The pressure drop is expressed as a function of the filter dimensions, the tow fiber characteristics, the filter weight, the fluid flow rate, and a filter fiber factor. Where, the filter fiber factor is affected by the distribution of the tow fibers within the filter, the relative orientations of the tow fibers, and their cross-sectional shapes. The minimum and maximum fraction of solids in capability curves determined from experimental data. Also, the filter fiber factor is expressed as a function of the filter length, tow fiber length, and tow fiber diameter. Capability curves predicted by the suggested model in this work correspond well with capability curves by experimental data.

Efficacy of subcutaneous granulocyte colony-stimulating factor infusion for treating thin endometrium

  • Banerjee, Kaberi;Singla, Bhavana;Verma, Priyanka
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.49 no.1
    • /
    • pp.70-73
    • /
    • 2022
  • Objective: This study was conducted to assess the efficacy of subcutaneous granulocyte colony-stimulating factor (G-CSF) for treating thin endometrium. Methods: Data from 88 infertile women with thin endometrium (<7 mm) aged 23 to 40 years were evaluated retrospectively over a period of 1 year. In group 1, subcutaneous infusion of G-CSF (300 ㎍/mL) was administered to 44 women along with other supplemental treatments. If the lining did not exceed 7 mm within 72 hours, a second infusion was administered. In group 2, which also had 44 women, only estradiol valerate and sildenafil were administered, while subcutaneous G-CSF infusion was not. Embryo transfers were performed once the lining exceeded 7.5 mm. The efficacy of G-CSF was evaluated by assessing the thickness of the endometrium before embryo transfer, pregnancy rates, and clinical pregnancy rates. Results: There were no differences between the groups regarding demographic variables, egg reserves, sperm parameters, the number of embryos transferred, and embryo quality. The pregnancy rate was significantly higher in group 1 (60%, 24 of 40 cases) than in group 2 (31%, 9 of 29 cases) (p<0.001). The clinical pregnancy rate was also significantly higher in group 1 (55%) than in group 2 (24%) (p<0.001). Conclusion: Subcutaneous G-CSF infusion improved the thickness of the endometrium when it was thin. To the best of our knowledge, this is the first documented study to clearly demonstrate the benefits of subcutaneous G-CSF infusion for treating thin endometrium.

A Study on the Enhancement of Inventories for Precursors (NOx, SOx) Released from Open Burning of Agricultural Waste Vinyl Causing the Secondary Generation of Particulate Matters

  • Kim, Tae-Han;Choi, Boo-Hun
    • Journal of People, Plants, and Environment
    • /
    • v.24 no.2
    • /
    • pp.195-207
    • /
    • 2021
  • Background and objective: While response measures to particulate matters in rural areas are limited due to poor inventory record keeping in the agricultural sector, it is necessary to control agricultural waste vinyl and the emission of precursors released from open burning and the secondary generation of particulate matters. Currently, the open burning emission calculation method uses the definition prescribed in CAPSS by the National Institute of Environmental Research. Methods: This study presented an open burning emission calculation formula for agricultural waste vinyl, which is included as agricultural waste. As for activity data, the open burning ratio of agricultural waste vinyl, and the annual incineration volume provided in the Status Survey by the Ministry of Agriculture, Food, and Rural Affairs were applied. The emission factor was generated through incineration tests on three agricultural plastic film samples collected by the Korea Environment Corporation. Results: Among precursors, SOx and NOx were selected and their emission features were monitored with incineration experiment infrastructure based on the EPA 5G method. The highest emission concentration by agricultural waste type was concentrated in the first and second quarters. As for emission factor of SO2, it was calculated at 98.25 g/kg for mulching-use LDPE, 52.31 g/kg for greenhouse-use LDPE, and 14.40 g/kg for HDPE. As for NOx, it was calculated at 18.21 g/kg for mulching-use LDPE, 16.49 g/kg for greenhouse-use LDPE, and 10.67 g/kg for HDPE. Conclusion: This test confirmed the incineration features of PE-based plastics, ascertained the SOx emission factor that had not been included in open burning in the past, and established that low NOx emission concentration is interfered by soil mixed with livestock excretions. The findings from this study are expected to contribute to improving the system for controlling air pollutants in rural environments.

Therapeutic Effect of Different Doses of Recombinant Human Granulocyte Colony-Stimulating Factor(rhG-CSF) on Neonatal Sepsis Complicated by Neutropenia (호중구 감소증이 합병된 신생아 패혈증에서 Recombinant Human Granulocyte Colony-Stimulating Factor(rhG-CSF)의 투여 용량에 따른 치료 효과)

  • Choi, Moon Young;Jung, Yeon Sook;Son, Dong Woo;Ahn, Hyo Seop
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.4
    • /
    • pp.439-448
    • /
    • 2002
  • Purpose : The aim of this study is to determine and compare the effects of adjunctive therapy with different doses of recombinant human granulocyte-colony stimulating factor(rhG-CSF) on reversing sepsis-associated neonatal neutropenia, and their survival rate in a group I/II-type trial. Methods : RhG-CSF was injected subcutaneously to 10 septic-neutropenic neonates with doses of $10{\mu}g/kg$ from Oct. 1995 to Sep. 1996, and was administered to another 12 septic-neutropenic neonates with doses of $5{\mu}g/kg$ from Oct. 1996 to Sep. 1997. Neutrophilic responses and the outcomes of both groups were compared. Results : In the rhG-CSF $10{\mu}g/kg$ treated group and in the $5{\mu}g/kg$ treated group, the absolute neutrophil count(ANC) was $1,065{\pm}89$($mean{\pm}SEM$) and $1,053{\pm}131$, respectively. The only difference between the two groups was the peak ANC at 48 hours. Eight patients from the remaining nine of rhG-CSF $10{\mu}g/kg$ treated group(88.9%) and ten in $5{\mu}g/kg$ treated group(83.3%) survived the sepsis and were discharged without any problems. Conclusions : RhG-CSF can increase the neutrophil count in critically ill septic neutropenic neonats. The survival rate of both groups were up to 90%. This finding suggests that both doses of rhG-CSF may be effective in a therapeutically useful time frame to treat septic neonates with neonatal neutropenia attributable to bone marrow supression or neutrophil consumption.

Growth Factor Receptor Expression on Brain Tumor Cell Lines : Preliminary Study for in vitro and in vivo Experiments of Immunotoxin Therapy (뇌종양세포주에서의 성장인자수용체의 발현 : 면역독소 치료의 연구를 위한 예비실험)

  • im, Ki-Uk;Ni, Hsiao-Tzu;Low, Walter C.;Hall, Walter A.
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.6
    • /
    • pp.731-737
    • /
    • 2000
  • Objective : Growth factor receptors on the tumor cells are known to be expressed highly allowing the tumor cells to bind growth factors to stimulate cellular division. Immunotoxin therapy is one of the novel approaches to the primary malignant brain tumor, and expression of cell-surface receptor is essential for the immunotoxin to have specific anti-tumor activity. Despite promising cytotoxic activity of immunotoxin, tumor responses are not curative on clinical trials, and additional studies are needed regarding various factors influencing the efficacy of the immunotoxin. The purpose of this study is to detect the expression of various growth factor receptors on brain tumor cell lines which are going to be used in these studies. Materials and Methods : The authors detected transferrin receptor(TR), insulin-like growth factor-1 receptor(IGF-1R), and interleukin-4 receptor(IL-4R) on medulloblastoma cell line(Daoy) and glioblastoma cell lines(U373 MG and T98 G) by flow cytometric analysis. Results : TR was expressed on Daoy, U373 MG, and T98 G. IGF-1R was expressed on Daoy and U373 MG, but not on T98 G. IL-4R was expressed on all cell lines tested. Conclusion : The transferrin and interleukin-4 receptors might be good targets for immunotoxin therapy. The results should be considered in additional in vitro and in vivo studies regarding immunotoxin and in establishing the proper treatment model of the immunotoxin therapy including selection of the adequate immunotoxin.

  • PDF

Correlations between Gastroscopy Results and Zone-5 Data from the 7-zone-Diagnostic System (7구역진단기의 5구역 정보와 위내시경 소견의 상관성에 관한 연구)

  • Jung, Jung Da;Im, Jeong Gyun;Lee, Hyung Geol;Yook, Tae Han;Kim, Jong Uk
    • Journal of Acupuncture Research
    • /
    • v.30 no.1
    • /
    • pp.1-11
    • /
    • 2013
  • Objectives : The 7-zone-diagnostic system is a device for predetermining bodily locations by measuring the energy of the living body. The purpose of this study is to examine correlations between gastroscopy results and zone-5 data from the 7-zone-diagnostic system. Methods : This study was carried out with data from gastroscopy procedures. It involved 115 patients who had been diagnosed with gastritis, esophagitis, or gastric ulcers. These patients were divided into three groups according to the different patterns of zone-5 factors AA, FL2 and FL1. Group A was made up of patients for whom the red bar graph of zone-5 was higher than the normal range for factor AA. Group B was made up of patients for whom the red bar graph of zone-5 was within the normal range for factor AA. Group C was made up of patients for whom the red bar graph of zone-5 was lower than the normal range for factor AA. Group D E and F were made up of same way as group A B and C for factor FL2. Group G H and I were made up of same way as group A B and C for factor FL1. After the collection of gastroscopy results and data on zone-5 from the 7-zone-diagnostic system, the data was analyzed statistically. Results : 1. Group D had a higher ratio of medication than group E, and this result was statistically significant. 2. Group D G had a higher ratio of medication than group E G and group E H, and this result was statistically significant. 3. Group G had a higher ratio of esophagitis than group H, and this result was statistically significant. 4. A Group B H had a higher ratio of esophagitis than group B G, group C G, and group C H, and this result was statistically significant. 5. The medication group had a high score on the function index than the non-medication group, and this result was statistically significant. Conclusions : This study suggests that there is a slight correlation between gastroscopy results and zone-5 data from the 7-zone-diagnostic system. The research resulted in significant data that are helpful for diagnosing digestive system problems through the use of the 7-zone-diagnostic system.