• 제목/요약/키워드: fuzzy factor method

검색결과 227건 처리시간 0.024초

Hybrid of the fuzzy logic controller with the harmony search algorithm to PWR in-core fuel management optimization

  • Mahmoudi, Sayyed Mostafa;Rad, Milad Mansouri;Ochbelagh, Dariush Rezaei
    • Nuclear Engineering and Technology
    • /
    • 제53권11호
    • /
    • pp.3665-3674
    • /
    • 2021
  • One of the important parts of the in-core fuel management is loading pattern optimization (LPO). The loading pattern optimization as a reasonable design of the in-core fuel management can improve both economic and safe aspects of the nuclear reactor. This work proposes the hybrid of fuzzy logic controller with harmony search algorithm (HS) for loading pattern optimization in a pressurized water reactor. The music improvisation process to find a pleasing harmony is inspiring the harmony search algorithm. In this work, the adjustment of the harmony search algorithm parameters such as the bandwidth and the pitch adjustment rate are increasing performance of the proposed algorithm which is done through a fuzzy logic controller. Hence, membership functions and fuzzy rules are designed to improve the performance of the HS algorithm and achieve optimal results. The objective of the method is finding an optimum core arrangement according to safety and economic aspects such as reduction of power peaking factor (PPF) and increase of effective multiplication factor (Keff). The proposed approach effectiveness has been tried in two cases, Michalewicz's bivariate function problem and NEACRP LWR core. The results show that by using fuzzy harmony search algorithm the value of the fitness function is improved by 15.35%. Finally, with regard to the new solutions proposed in this research it could be used as a trustworthy method for other optimization issues of engineering field.

Adaptive Fuzzy Inference System using Pruning Techniques

  • Kim, Chang-Hyun;Jang, Byoung-Gi;Lee, Ju-Jang
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2003년도 ISIS 2003
    • /
    • pp.415-418
    • /
    • 2003
  • Fuzzy modelling has the approximation property far the given input-output relationship. Especially, Takagi-Sugeno fuzzy models are widely used because they show very good performance in the nonlinear function approximation problem. But generally there is not the systematic method incorporating the human expert's knowledge or experience in fuzzy rules and it is not easy to End the membership function of fuzzy rule to minimize the output error as well. The ANFIS (Adaptive Network-based Fuzzy Inference Systems) is one of the neural network based fuzzy modelling methods that can be used with various type of fuzzy rules. But in this model, it is the problem to End the optimum number of fuzzy rules in fuzzy model. In this paper, a new fuzzy modelling method based on the ANFIS and pruning techniques with the measure named impact factor is proposed and the performance of proposed method is evaluated with several simulation results.

  • PDF

Intelligent fuzzy weighted input estimation method for the input force on the plate structure

  • Lee, Ming-Hui;Chen, Tsung-Chien
    • Structural Engineering and Mechanics
    • /
    • 제34권1호
    • /
    • pp.1-14
    • /
    • 2010
  • The innovative intelligent fuzzy weighted input estimation method which efficiently and robustly estimates the unknown time-varying input force in on-line is presented in this paper. The algorithm includes the Kalman Filter (KF) and the recursive least square estimator (RLSE), which is weighted by the fuzzy weighting factor proposed based on the fuzzy logic inference system. To directly synthesize the Kalman filter with the estimator, this work presents an efficient robust forgetting zone, which is capable of providing a reasonable compromise between the tracking capability and the flexibility against noises. The capability of this inverse method are demonstrated in the input force estimation cases of the plate structure system. The proposed algorithm is further compared by alternating between the constant and adaptive weighting factors. The results show that this method has the properties of faster convergence in the initial response, better target tracking capability, and more effective noise and measurement bias reduction.

Predicting Successful Defibrillation in Ventricular Fibrillation using Wave Analysis and Neuro-fuzzy

  • Shin Jae-Woo;Lee Hyun-Sook;Hwang Sung-Oh;Yoon Young-Ro
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권2호
    • /
    • pp.47-52
    • /
    • 2006
  • The purpose of this study was to predict successful defibrillation in ventricular fibrillation using parameters extracted by wave analysis method and neuro-fuzzy. Total 15 dogs were tested for predicting successful defibrillation. Feature parameters were extracted for return of spontaneous circulation (ROSC) and non-ROSC by wave analysis method, and these parameters are an irregularity factor, spectral moments, mean power of level-crossing spectrum, and mean of alpha-significant value. Additionally, two parameters by analyzing method of frequency were extracted into a mean of power spectrum and a mean frequency. Then extracted parameters were analyzed in which parameters result to have high performance of discriminating ROSC and non-ROSC by a statistical method of t-test. The average of sensitivity and specificity were 62.5% and 75.0%, respectively. The average of positive predictive factor and negative predictive factor were 61.2% and 75.8%, respectively.

퍼지 규칙기반제어기에서 시스템의 성능평가 (The Performance Evaluation of Fuzzy Rule-Based System)

  • 김영철;최종수;최한수;김성중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.261-264
    • /
    • 1992
  • In designing the fuzzy rule-based system, it has effected by the four significant factors such as the choice of membership function, scaling factor, the numbers of fuzzy control rule, the method of defuzzification. In this paper we design the fuzzy rule based system and evaluate by three factors, as followes reaching time, overshoot, and amplitude. And then we wiII show that the significant factors are the choice of scaling factor and the numbers of fuzzy control rule, and the system performance can be improved by the proper selection of the scaling factors.

  • PDF

Parallel Fuzzy Inference Method for Large Volumes of Satellite Images

  • Lee, Sang-Gu
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제1권1호
    • /
    • pp.119-124
    • /
    • 2001
  • In this pattern recognition on the large volumes of remote sensing satellite images, the inference time is much increased. In the case of the remote sensing data [5] having 4 wavebands, the 778 training patterns are learned. Each land cover pattern is classified by using 159, 900 patterns including the trained patterns. For the fuzzy classification, the 778 fuzzy rules are generated. Each fuzzy rule has 4 fuzzy variables in the condition part. Therefore, high performance parallel fuzzy inference system is needed. In this paper, we propose a novel parallel fuzzy inference system on T3E parallel computer. In this, fuzzy rules are distributed and executed simultaneously. The ONE_To_ALL algorithm is used to broadcast the fuzzy input to the all nodes. The results of the MIN/MAX operations are transferred to the output processor by the ALL_TO_ONE algorithm. By parallel processing of the fuzzy rules, the parallel fuzzy inference algorithm extracts match parallelism and achieves a good speed factor. This system can be used in a large expert system that ha many inference variables in the condition and the consequent part.

  • PDF

A Study on Performance Assessment Methods by Using Fuzzy Logic

  • Kim, Kwang-Baek;Kim, Cheol-Ki;Moon, Jung-Wook
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제3권2호
    • /
    • pp.138-145
    • /
    • 2003
  • Performance assessment was introduced to improvement of self-directed learning and method of assessment for differenced learning as the seventh educational curriculum is enforced. Performance assessment is overcoming limitation about problem solving ability and higher thinking abilities assessment that is problem of a written examination and get into the spotlight by way for quality of class and school normalization. But, performance assessment has problems about possibilities of assessment fault by appraisal, fairness, reliability, and validity of grading, ambiguity of grading standard, difficulty about objectivity security etc. This study proposes fuzzy performance assessment system to solve problem of the conventional performance assessment. This paper presented an objective and reliable performance assessment method through fuzzy reasoning, design fuzzy membership function and define fuzzy rule analyzing factor that influence in each sacred ground of performance assessment to account principle subject. Also, performance assessment item divides by formation estimation and subject estimation and designed membership function in proposed performance assessment method. Performance assessment result that is worked through fuzzy performance assessment system can pare down burden about appraisal's fault and provide fair and reliable assessment result through grading that have correct standard and consistency to students.

퍼지제어기의 최적 설계에 관한 연구 (A Study on the Optimal Design of Fuzzy Logic Controller)

  • 노기갑;김성호;주영훈;박진배
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1997년도 추계학술대회 학술발표 논문집
    • /
    • pp.50-54
    • /
    • 1997
  • In general, the design of fuzzy logic controller has difficulties in the acquisition of expert's knowledge. So, some methods that can optimize the parameters for fuzzy logic controller automatically without expert knowledge was provided. Recently, tuning method for fuzzy logic controller using genetic algorithm(GA) were proposed in many papers. However, those are tuning methods for a part or some part of fuzzy logic controller. In this paper, we proposes auto tuning method for the whole part of tuzzy logic controller, such as parameters of membership functions for antecedence and consequence parts, rule base, scaling factor and the number of rule. Finally, second order dead time plant is provided to show the advantages of the proposed method.

  • PDF

퍼지제어 시스템에서의 파라미터 동조방법 (A parameter tuning method in fuzzy control systems)

  • 최종수;김성중;권오신
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.479-483
    • /
    • 1992
  • This paper defines the relationship between PI type fuzzy control system and conventional PI control system, and discusses the relationship of parameters and control action in fuzzy controller. The tuning algorithm that updates ouput variable scaling factor of fuzzy controller is proposed .The proposed sheme is applied to the simulations of 2 selected dynamical plants. The simulation results show that the controller is effective in controlling dynamical plants.

  • PDF

퍼지논리를 이용한 저온저장고의 온도제어시스템 개발 (Development of Temperature Control System for Cold Storage Room Using Fuzzy Logic)

  • 양길모;고학균;조성인
    • Journal of Biosystems Engineering
    • /
    • 제25권2호
    • /
    • pp.107-114
    • /
    • 2000
  • Low temperature storage method is to increase the value of agricultural products by reducing quality loss and regulate consignment time by controlling respiration rates of agricultural products. Respiration rate of agricultural products depends on several factors such as temperature, moisture, gas composition and a microbe inside the storage room. Temperature is the most important factor among these, which affects respiration rate and causes low or high temperature damage. Fuzzy logic was used to control the temperature of a storage room ,which uses information of uncertain facts and mathematical model for room temperature control . Room temperature was controlled better by using fuzzy logic control method rather than on-off control method. Refrigerant flow rates and temperature deviations were measured for on-off system using TEV(temperature expansion valve) and for fuzzy system using EEV(Electrical Expansion Valve) . Temperature of the Storage room was lowered faster by using fuzzy system than on -off system. Temperature deviation was -0.6~+0.9$^{\circ}C$ for on-off system and $\pm$0.2$^{\circ}C$ for fuzzy system developed. Temperature deviation and variation of temperature deviation were used as inout parameters for fuzzy system. The most suitable input and output value were found by experiment. Cooling rate of the storage room decreased while temperature deviation increased for the sampling time of 20 sec.

  • PDF