• Title/Summary/Keyword: functional analysis of variance

Search Result 146, Processing Time 0.023 seconds

The Evaluation of Clinical Usefulness on Application of Myocardial Extract in Quantitative Perfusion SPECT (QPS 프로그램에서 Myocardial extract 적용에 따른 임상적 유용성 평가)

  • Yun, Jong-Jun;Lim, Yeong-Hyeon;Lee, Mu-Seok;Song, Hyeon-Seok;Jeong, Ji-Uk;Park, Se-Yun;Kim, Jae-Hwan;Kim, Jeong-Uk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.88-93
    • /
    • 2011
  • Purpose: As to analytical method of data, the AutoQUANT software in which it is used quantitative rating of the myocardial perfusion SPECT are reported that there is a difference. Therefore the measured value error of the mutual program is expected to be generated even if the quantitative analysis is made data of the same patient. The purpose of this study is to offer the comparative analysis of myocardial extract method in Quantitative Perfusion SPECT. Materials and methods: We analyzed the 51 patients who were examined by Tc-99m MIBI gated myocardial SPECT in nuclear medicine department of Pusan National University Hospital from June to December 2010(34 men, 17 women, mean age $66.5{\pm}9.9$). We acquired the extracted image in myocardial extract protocol. QPS program that uses the AutoQUANT software measured TID(Transient Ischemic Dilation), ESD(Extent of Stress Defect), SSS(Summed Stress Score). Then analyzed the results. Results: The correlation of appyling myocardial extract is TID(r=0.98), ESD(r=0.99), SSS(r=0.99). In the 95% confidence limit, there was no satistically significant difference(TID p=0.78, ESD p=0.31, SSS p=0.19). After blinding test with a physician for making a qualitative analysis, there was no difference. Conclusion: Quantitative indices in QPS program showed good correlation and the results showed no statistically signigicant difference. The variance between method was small. therefore, the functional parameters by each method can be used interchangeably. Also, we expect patient's satisfaction.

  • PDF

The Impact of e-Store Personality on e-Store Loyalty-Focus on the Mediating Role of Identification, Trust, and Engagement (온라인에서 점포 개성이 점포 충성도에 미치는 영향-동일시, 신뢰, 인게이지먼트의 매개 역할을 중심으로)

  • Park, Hyo-Hyun;Jung, Gang-Ok;Lee, Seung-Chang
    • Journal of Distribution Research
    • /
    • v.16 no.2
    • /
    • pp.57-94
    • /
    • 2011
  • Nowadays, it is common that most consumers are purchasing goods in e-stores. The e-stores eager to attract, revisit, retain, and finally convert them into loyal customers. The e-store marketers have planned and executed numerous marketing efforts. As one of the marketing activities, e-store managers attempt to build web sites that meet customers' functional and psychological needs. A wide array of studies has been done to identify factors that could affect customers' response of web sites. Majority of studies were conducted to verify technology-related and functional variables of the website which facilitate transactions and enhance customer responses such as purchase intention and website loyalty. However, there has been little research on the external cues of website and psychological variables of consumer that could have positive influences on customer response. The purpose of this study is to investigate the influence of e-store personality on e-store loyalty through mediating variables such as e-store identification, e-store trust, and e-store engagement. The authors of this study develop the model and set up the six main hypotheses and a set of sub-hypotheses based on a literature review, shown in

    . This model is composed of four paths such as dimensions of e-store personality${\rightarrow}$e-store identification, e-store identification${\rightarrow}$e-store loyalty, e-store identification ${\rightarrow}$e-store trust${\rightarrow}$e-store loyalty, and e-store identification${\rightarrow}$e-store engagement${\rightarrow}$e-store loyalty. II. Research Method Ladies under 30s were the respondents of this survey. Data were collected from January 20th to February 26th in 2010. A total of 200 questionnaires were distributed and 169 respondents were analysed finally to test hypotheses because 31 questionnaires had incorrect or missing responses. SPSS 12.0 and LISREL 7.0 program were used to test frequency, reliability, factor, and structural equation modeling analysis. III. Result and Conclusion According to results from factor analysis, eigen value was over 1.0 and items which were below 0.6 were deleted. Consequently, 9 factors(% of total variance is 72.011%) were searched. All Cronbach's ${\alpha}$ values are over the recommended level(${\alpha}$ > 0.7). The overall fit indices are acceptable such as ${\chi}^2$=2028.36(p=0.00), GFI=0.87, AGFI=0.82, CFI=0.81, IFI=0.92, RMR=0.075. All factor loadings were over the recommended level. As the result of discriminant validity check with chi-square difference test between paired constructs, each construct has good discriminant validity. The overall fit indices of final model are acceptable such as ${\chi}^2$=340.73(df=36, p=0.00), GFI=0.92, AGFI=0.81, CFI=0.91, IFI=0.91, RMR=0.085. As test results, 5 out of 6 hypotheses are supported because there are statistically significant casual relationships in structural equation model, shown in . First of all, hypothesis 1 is partially supported because sub-hypothesis 1-1 and 1-2 are supported, whereas sub-hypothesis 1-3, 1-4, and 1-5 are rejected. Specifically, it reveals that warmth and sophistication dimensions in e-store personality have positive influence on e-store identification, however, activity, progressiveness, and strictness does not have any significant relationship on e-store identification. Secondly, hypothesis 2 was supported. Therefore, it can be said that e-store identification has a positive impact on e-store trust. Thirdly, hypothesis 3 is also supported. Hence, there is a positive relationship between e-store identification and e-store engagement. Fourthly, hypothesis 4 is supported too. e-store identification has a positive influence on e-store loyalty. Fifthly, hypothesis 5 is also accepted. This indicates that e-store trust is a precedent variable which positively affects e-store loyalty. Lastly, it reveals that e-store engagement has a positive impact on e-store loyalty. Therefore, hypothesis 6 is supported. The findings of the study imply that some dimensions of e-store personality have a positive influence on e-store identification, and that e-store identification has direct and indirect influence on e-store loyalty through e-store trust and e-store engagement positively. These results also suggest that the e-store identification in e-store personality is a precedent variable which positively affects e-store loyalty directly and indirectly through e-store trust and engagement as a mediating variable. Therefore, e-store marketers need to implement website strategy based on e-store personality, e-store identification, e-store trust, and e-store engagement to meet customers' psychological needs and enhance e-store loyalty. Finally, the limitations and future study directions based on this study are discussed.

  • PDF
  • A Prospective Clinical Trial on the Mg Oxidized Clinical Implants (마그네슘 양극산화 임플란트의 성공률에 관한 전향적 임상연구)

    • Im, So-Min;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra;Um, Heung-Sik;Lee, Jae-Kwan
      • Journal of Dental Rehabilitation and Applied Science
      • /
      • v.27 no.1
      • /
      • pp.25-39
      • /
      • 2011
    • In animal studies, Magnesium (Mg) - incorporated oxidized implants showed significant enhancement of the bone response. This prospective clinical trial was performed to investigate the success rate, implant stability and marginal bone loss of Mg oxidized clinical implant. The experimental protocol was approved by Institutional Review Board of the Gangneung-Wonju National University Dental Hospital. Fifty healthy patients had partial edentulism were included in this study. Mg oxidized clinical implants (Implant M, Shinhung, Korea) were installed and restored with conventional protocol. The patients were recalled at 1, 3, 6 months after functional loading. Implant stability quotient (ISQ) was measured and periapical radiographic images were obtained. Amount of marginal bone loss was calculated with calibrated images from periapical radiographs. Repeated measured analysis of variance and post hoc Tukey test were used to compare the mean ISQ and bone level. A total of 101 implants were analyzed. The mean ISQ values increased continuously with time lapse from 68.4 at fixture installation to 71.5 at 6 months after loading. Implant stability was correlated with gender, fixture diameter, bone quality and implant sites. The mean marginal bone loss during 6 months after loading was 0.26 mm. There was no failed implant and six-month success rate was 100%. Within the limitations of this study, the six-month success rate of Mg oxidized implant was satisfactory. The implant stability and marginal bone level were excellent. However, further longer clinical studies will be needed to confirm the success of Mg oxidized clinical implant.

    Optimization Mixture Ratio of Petasites japonicus, Luffa cylindrica and Houttuynia cordata to Develop a Functional Drink by Mixture Design (혼합물 실험계획법에 의한 머위 및 부원료의 혼합비율 최적화)

    • Jeong, Hae-Jin;Lee, Kyoung-Pil;Chung, Hun-Sik;Kim, Dong-Seop;Kim, Han-Soo;Choi, Young-Whan;Im, Dong-Soon;Seong, Jong-Hwan;Lee, Young-Guen
      • Journal of Life Science
      • /
      • v.25 no.3
      • /
      • pp.329-335
      • /
      • 2015
    • This study was performed to determine the optimal ratio of Petasites japonicus, Luffa cylindrica, and Houttuynia cordata, all of which are supposed to have anti-respiratory disease effects, such as against rhinitis. The experiment incorporated a mixture design and included 12 experimental points with center replicates for three different independent variables (Petasites japonicus 30~70%; Luffa cylindrica 10~30%; and Houttuynia cordata 10~30%). Based on this design, the mixture was extracted in hot water at 121℃ for 45 min and anti-allergy and anti-microbial activities were observed. The response surface and trace plot described for the anti-allergy activity showed Petasites japonicas was a relatively important factor. The correlation coefficient (R2) value 82.10% for the inhibition effect of degranulation was analyzed by the regression equation. The analysis of variance showed the model fit was statistically significant (p<0.05). The optimal ratio of the mixture was Petasites japonicus 0.75%, Luffa cylindrica 0.11%, and Houttuynia cordata 0.14%. The anti-microbial activity for each extraction of the mixture was valid on gram-positive, such as Staphylococcus aureus (KCCM 40881) and Staphylococcus epidermidis (KCCM 35494), while it was less effective on gram-negative, such as Escherichia coli (KCCM 11234) and Pseudomonas aeruginosa (KCCM 11328).

    Development and Animal Tests of Prototype Oxygen Concentrator (국산 산소 농축기의 개발 및 동물실험)

    • 변정욱;성숙환;이태수
      • Journal of Chest Surgery
      • /
      • v.31 no.7
      • /
      • pp.643-649
      • /
      • 1998
    • Background: For the patient with chronic obstructive pulmonary disease requiring long-term oxygen therapy, oxygen concentrator machines are already widely available for use in home. In this study, we used mongrel dogs as test subjects to compare the functional efficiency and safety of the oxygen concentrator developed by our own research team with those of the imported FORLIFE(TM) machine made by AIRSEP Corp. Method and method: To test mechanical reliability, the concentrations of oxygen delivered were measured after 4 hours of continuous operation. Sixteen mongrel dogs were divided into two equal groups. Mongrel dogs in group A were given oxygen using the imported oxygen concentrator, and those in group B using the machine developed. 5 l/min of oxygen were given, after which vital signs were analyzed, arterial blood gases measured, and blood chemistry tests carried out. Results: After 4 hours of continuous operation, the imported model performed better, giving 98${\pm}$3% oxygen, compared to our model, which gave 91${\pm}$1%. In the animal experiments, oxygen concentrations were measured at the inlet of face mask 1, 2, 3, and 4 hours after continuous administration, and there was no statistically significant difference(repeated measures of analysis of variance p=0.70) between the values of 70.6${\pm}$2.5%, 67.1${\pm}$2.9%, 68.2${\pm}$2.6%, and 64.9${\pm}$3.9% that were measured from group A, and the values of 65.1${\pm}$4.8%, 65.2${\pm}$3.6%, 68.7${\pm}$4.3%, and 66.0${\pm}$5.0% measured from group B. Before oxygen administration, and at 1, 2, 3, and 4 hours after oxygen administration, arterial blood partial pressure of oxygen 87.2${\pm}$2.5 mmHg, 347.4${\pm}$29.3 mmHg, 353.4${\pm}$21.2 mmHg, 343.0${\pm}$28.8 mmHg, and 321.6${\pm}$24.4 mmHg, respectively, were read from group A, which were not statistically different (p=0.24) to the values of 102.5${\pm}$9.6 mmHg, 300.3${\pm}$17.1 mmHg, 321.6${\pm}$23.7 mmHg, 303.4${\pm}$27.4 mmHg, and 273.5${\pm}$25.9 mmHg read from group B. Nonetheless, the arterial blood partial pressure of oxygen values appear to be somewhat higher in dogs that were given oxygen using the imported oxygen concentrator. Conclusions: From these results the prototype oxygen concentrator developed appears to function relatively satisfactorily compared to the imported, established model, but may be criticized for the excessive noise generated and poor long-term endurance or consistency, which need improvement.

    • PDF

    Cardioprotective Effect by Preconditioning with Calcium-free Solution (칼슘결핍용액 투여 전처치에 의한 심근보호 효과)

    • 조대윤;이종화;김호덕
      • Journal of Chest Surgery
      • /
      • v.32 no.9
      • /
      • pp.773-780
      • /
      • 1999
    • Background: It has been demonstrated that brief periods of calcium depletion and repletion (calcium-free preconditioning, CP) have cardioprotective effects as seen in ischemic preconditioning(IP) which enhances the recovery of post-ischemic contractile dysfunction and reduces the incidence of reperfusion-induced arrhythmia or infarct size after a prolonged ischemia. In the present study, we tested this paradoxical phenomenon in isolated rabbit hearts. Material and Method: Hearts isolated from New Zealand white rabbits(1.5∼2.0 Kg body weight) were perfused with Tyrode solution using the Langendorff technique. After stabilizing the baseline hemodynamics, the hearts were subjected to 45 minutes of global ischemia followed by 120 minutes of reperfusion with IP(IP group, n=7) or without IP (ischemic control group, n=7). IP was induced by a single episode of 5 minutes global ischemia and 10 minutes reperfusion. In the CP group(n=7), the hearts were subjected to perfusion with Tyrode solution with calcium depletion for 5 minutes and repletion for 10 minutes, and 45 minutes of ischemia and 120 minutes of reperfusion. Left ventricular function including developed pressure, dP/dt, heart rate, left ventricular end-diastolic pressure and coronary flow was measured. Infarct size was determined by staining with 1% triphenyltetrazolium chloride and planimetry. Data were analyzed by a one-way analysis of variance and Tukey's post-hoc test. Result: In comparison with the ischemic control group, IP significantly enhanced the recovery of the left ventricular function including the left ventricular developed pressure, contractility, and coronary flow; in contrast, these functional parameters of the CP group tended to be lower than those of the ischemic control group. However, the infarct size was significantly reduced by IP or CP(p<0.05). Conclusion: These results suggest that in isolated Langendorff-perfused rabbit heart model, CP(induced by single episode of 5 minutes calcium depletion and 10 minutes repletion) could not improve the post-ischemic contractile dysfunction(after a 45-minute global ischemia) but it has an infarct size-limiting effect.

    • PDF

    (34141) Korea Institute of Science and Technology Information, 245, Daehak-ro, Yuseong-gu, Daejeon
    Copyright (C) KISTI. All Rights Reserved.