• 제목/요약/키워드: full-scale bridge monitoring

검색결과 28건 처리시간 0.026초

Rapid full-scale expansion joint monitoring using wireless hybrid sensor

  • Jang, Shinae;Dahal, Sushil;Li, Jingcheng
    • Smart Structures and Systems
    • /
    • 제12권3_4호
    • /
    • pp.415-426
    • /
    • 2013
  • Condition assessment and monitoring of bridges is critical for safe passenger travel, public transportation, and efficient freight. In monitoring, displacement measurement capability is important to keep track of performance of bridge, in part or as whole. One of the most important parts of a bridge is the expansion joint, which accommodates continuous cyclic thermal expansion of the whole bridge. Though expansion joint is critical for bridge performance, its inspection and monitoring has not been considered significantly because the monitoring requires long-term data using cost intensive equipment. Recently, a wireless smart sensor network (WSSN) has drawn significant attention for transportation infrastructure monitoring because of its merits in low cost, easy installation, and versatile on-board computation capability. In this paper, a rapid wireless displacement monitoring system, wireless hybrid sensor (WHS), has been developed to monitor displacement of expansion joints of bridges. The WHS has been calibrated for both static and dynamic displacement measurement in laboratory environment, and deployed on an in-service highway bridge to demonstrate rapid expansion joint monitoring. The test-bed is a continuous steel girder bridge, the Founders Bridge, in East Hartford, Connecticut. Using the WHS system, the static and dynamic displacement of the expansion joint has been measured. The short-term displacement trend in terms of temperature is calculated. With the WHS system, approximately 6% of the time has been spent for installation, and 94% of time for the measurement showing strong potential of the developed system for rapid displacement monitoring.

Structural Health Monitoring of short to medium span bridges in the United Kingdom

  • Brownjohn, James M.W.;Kripakaran, Prakash;Harvey, Bill;Kromanis, Rolands;Jones, Peter;Huseynov, Farhad
    • Structural Monitoring and Maintenance
    • /
    • 제3권3호
    • /
    • pp.259-276
    • /
    • 2016
  • Historically the UK has been a pioneer and early adopter of experimental investigation techniques on new and operation structures, a technology that would now be descried as 'structural health monitoring' (SHM), yet few of these investigations have been enduring or carried out on the long span or tall structures that feature in flagship SHM applications in the Far East.

Structural health rating (SHR)-oriented 3D multi-scale finite element modeling and analysis of Stonecutters Bridge

  • Li, X.F.;Ni, Y.Q.;Wong, K.Y.;Chan, K.W.Y.
    • Smart Structures and Systems
    • /
    • 제15권1호
    • /
    • pp.99-117
    • /
    • 2015
  • The Stonecutters Bridge (SCB) in Hong Kong is the third-longest cable-stayed bridge in the world with a main span stretching 1,018 m between two 298 m high single-leg tapering composite towers. A Wind and Structural Health Monitoring System (WASHMS) is being implemented on SCB by the Highways Department of The Hong Kong SAR Government, and the SCB-WASHMS is composed of more than 1,300 sensors in 15 types. In order to establish a linkage between structural health monitoring and maintenance management, a Structural Health Rating System (SHRS) with relevant rating tools and indices is devised. On the basis of a 3D space frame finite element model (FEM) of SCB and model updating, this paper presents the development of an SHR-oriented 3D multi-scale FEM for the purpose of load-resistance analysis and damage evaluation in structural element level, including modeling, refinement and validation of the multi-scale FEM. The refined 3D structural segments at deck and towers are established in critical segment positions corresponding to maximum cable forces. The components in the critical segment region are modeled as a full 3D FEM and fitted into the 3D space frame FEM. The boundary conditions between beam and shell elements are performed conforming to equivalent stiffness, effective mass and compatibility of deformation. The 3D multi-scale FEM is verified by the in-situ measured dynamic characteristics and static response. A good agreement between the FEM and measurement results indicates that the 3D multi-scale FEM is precise and efficient for WASHMS and SHRS of SCB. In addition, stress distribution and concentration of the critical segments in the 3D multi-scale FEM under temperature loads, static wind loads and equivalent seismic loads are investigated. Stress concentration elements under equivalent seismic loads exist in the anchor zone in steel/concrete beam and the anchor plate edge in steel anchor box of the towers.

Innovative cable force monitoring of stay cables using piezoelectric dynamic strain responses

  • ;;이지용;신성우;김정태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.830-834
    • /
    • 2013
  • This study presents a method to monitor cable force of a long-span cable-stayed bridge using a smart piezoelectric sensor system. The following approaches are implemented in order to achieve the objective. Firstly, the method to utilize piezoelectric materials for the health monitoring of stay cables is presented. For strain measurement of a stay cable, a PZT-embedded smart skin is designed to overcome the difficulties of bonding PZT sensors directly on stay cables. Secondly, a piezoelectric strain monitoring system for stay cables is designed. For the operation of the sensor board, the Imote2 sensor platform is used to provide the computation, wireless communication and power supply units. The feasibility of the proposed monitoring system is then evaluated on a full-scale cable of a cable-stayed bridge.

  • PDF

Solar-powered multi-scale sensor node on Imote2 platform for hybrid SHM in cable-stayed bridge

  • Ho, Duc-Duy;Lee, Po-Young;Nguyen, Khac-Duy;Hong, Dong-Soo;Lee, So-Young;Kim, Jeong-Tae;Shin, Sung-Woo;Yun, Chung-Bang;Shinozuka, Masanobu
    • Smart Structures and Systems
    • /
    • 제9권2호
    • /
    • pp.145-164
    • /
    • 2012
  • In this paper, solar-powered, multi-scale, vibration-impedance sensor node on Imote2 platform is presented for hybrid structural health monitoring (SHM) in cable-stayed bridge. In order to achieve the objective, the following approaches are proposed. Firstly, vibration- and impedance-based hybrid SHM methods are briefly described. Secondly, the multi-scale vibration and impedance sensor node on Imote2-platform is presented on the design of hardware components and embedded software for vibration- and impedance-based SHM. In this approach, a solar-powered energy harvesting is implemented for autonomous operation of the smart sensor nodes. Finally, the feasibility and practicality of the smart sensor-based SHM system is evaluated on a full-scale cable-stayed bridge, Hwamyung Bridge in Korea. Successful level of wireless communication and solar-power supply for smart sensor nodes are verified. Also, vibration and impedance responses measured from the target bridge which experiences various weather conditions are examined for the robust long-term monitoring capability of the smart sensor system.

Bridge deflection evaluation using strain and rotation measurements

  • Sousa, Helder;Cavadas, Filipe;Henriques, Abel;Bento, Joao;Figueiras, Joaquim
    • Smart Structures and Systems
    • /
    • 제11권4호
    • /
    • pp.365-386
    • /
    • 2013
  • Monitoring systems currently applied to concrete bridges include strain gauges, inclinometers, accelerometers and displacement transducers. In general, vertical displacements are one of the parameters that more often need to be assessed because their information reflects the overall response of the bridge span. However, the implementation of systems to continuously and directly observe vertical displacements is known to be difficult. On the other hand, strain gauges and inclinometers are easier to install, but their measurements provide no more than indirect information regarding the bridge deflection. In this context, taking advantage of the information collected through strain gauges and inclinometers, and the processing capabilities of current computers, a procedure to evaluate bridge girder deflections based on polynomial functions is presented. The procedure has been implemented in an existing software system - MENSUSMONITOR -, improving the flexibility in the data handling and enabling faster data processing by means of real time visualization capabilities. Benefiting from these features, a comprehensive analysis aiming at assessing the suitability of polynomial functions as an approximate solution for deflection curves, is presented. The effect of boundary conditions and the influence of the order of the polynomial functions on the accuracy of results are discussed. Some recommendations for further instrumentation plans are provided based on the results of the present analysis. This work is supported throughout by monitoring data collected from a laboratory beam model and two full-scale bridges.

Wind characteristics at Sutong Bridge site using 8-year field measurement data

  • Xu, Zidong;Wang, Hao;Wu, Teng;Tao, Tianyou;Mao, Jianxiao
    • Wind and Structures
    • /
    • 제25권2호
    • /
    • pp.195-214
    • /
    • 2017
  • Full-scale wind characteristics based on the field measurements is an essential element in structural wind engineering. Statistical analysis of the wind characteristics at Sutong Cable-stayed Bridge (SCB) site is conducted in this study with the recorded long-term wind data from structural health monitoring system (SHMS) between 2008 and 2015. Both the mean and turbulent wind characteristics and power spectra are comprehensively investigated and compared with those in the current codes of practice, such as the measured wind rose diagram, monthly maximum mean wind speed, turbulence intensity, integral length scale. Measurement results based on the monitoring data show that winds surrounding the SCB site are substantially influenced by the southeast monsoon in summer and strong northern wind in winter. The measured turbulence intensity is slightly higher than the recommended values in specifications, while the measured ratio of lateral to longitudinal turbulence intensity is slightly lower. An approximately linear relationship between the measured turbulence intensities and gust factors is obtained. The mean value of the turbulence integral length scale is smaller than that of typical typhoon events. In addition, it is found that the Kaimal spectrum is suitable to be adopted as the power spectrum for longitudinal wind component at the SCB site. This contribution would provide important wind characteristic references for the wind performance evaluation of SCB and other civil infrastructures in adjacent regions.

실측 데이터를 이용한 공용중인 강사장교의 버페팅 응답 분석 (A Study on Buffeting Responses of a In-service Steel Cable-stayed Bridge Using Full-scale Measurements)

  • 이덕근;공민준;유동우
    • 대한토목학회논문집
    • /
    • 제36권3호
    • /
    • pp.349-359
    • /
    • 2016
  • 공용 중인 교량의 버페팅 응답을 해석적으로 평가하기 위해서는 교량 현장의 난류강도, 난류 스펙트럼, 조도계수, 거스트 계수 등 풍하중에 대한 분석이 우선되어야 하고, 해석 결과는 정적 공기력 계수, 플러터계수, 구조 감쇠비, 공기역학적 감쇠비, 고유 진동수 등 여러 변수에 의해 영향을 받는다. 본 논문에서 대상으로 한 교량은 32년째 공용 중에 있는 교량으로써 교량 주변의 지형조건은 설계 및 시공 당시에 비해 많은 변화가 발생하였으며 최근 기후 변화로 인한 풍 환경 역시 큰 변화가 있다. 이러한 이유로 대상교량에서 실측한 풍속 데이터를 분석하여 난류강도, 난류길이, 지표조도계수, 풍속 스펙트럼 등 교량 현장의 풍하중을 평가하였다. 교량 주변의 풍환경 평가 결과, 대상 교량은 해상교량임에도 불구하고 지표조도구분 II의 특성을 나타내고 있었다. 또한 실측한 구조물의 가속도, 변위 응답 데이터를 통해 대상교량의 감쇠비, 정적 공기력 계수, 고유진동수를 평가하여 계측기반 버페팅 해석 변수를 산정하였다. 계측데이터 기반의 해석 변수와 케이블강교량설계지침에 제시된 해석 변수를 적용하여 총 4가지 경우에 대한 버페팅 해석을 수행하였으며, 그 결과 10분 평균 풍속 25m/s이하에서 측정된 버페팅 응답과 계측 기반 해석 변수를 적용한 해석 응답이 가장 잘 일치함을 확인하였고, 계측 풍속과 Gumbel 확률분포를 이용하여 추정한 200년 재현기대 풍속인 45m/s에서의 버페팅 응답을 제시하였다.

Structural Health Monitoring System of Long-Span Bridges in Korea

  • Chang, Sung-Pil
    • Corrosion Science and Technology
    • /
    • 제3권2호
    • /
    • pp.39-46
    • /
    • 2004
  • Development and application of structural health monitoring system in Korea have become active since the early 1990's. In earlier applications, health monitoring systems were installed in several existing bridges in order to collect initial field data by full scale load capacity test for design verification and subsequently monitor long-term performance and durability of the bridge as part of an inspection and maintenance program. Recently, modem and integrated monitoring systems have been introduced in most of the newly constructed long-span bridges since the design stage. This paper outlines the progresses and applications of monitoring systems in Korea for both existing and newly constructed bridges and describes their aims and characteristics.

Damage detection of bridges based on spectral sub-band features and hybrid modeling of PCA and KPCA methods

  • Bisheh, Hossein Babajanian;Amiri, Gholamreza Ghodrati
    • Structural Monitoring and Maintenance
    • /
    • 제9권2호
    • /
    • pp.179-200
    • /
    • 2022
  • This paper proposes a data-driven methodology for online early damage identification under changing environmental conditions. The proposed method relies on two data analysis methods: feature-based method and hybrid principal component analysis (PCA) and kernel PCA to separate damage from environmental influences. First, spectral sub-band features, namely, spectral sub-band centroids (SSCs) and log spectral sub-band energies (LSSEs), are proposed as damage-sensitive features to extract damage information from measured structural responses. Second, hybrid modeling by integrating PCA and kernel PCA is performed on the spectral sub-band feature matrix for data normalization to extract both linear and nonlinear features for nonlinear procedure monitoring. After feature normalization, suppressing environmental effects, the control charts (Hotelling T2 and SPE statistics) is implemented to novelty detection and distinguish damage in structures. The hybrid PCA-KPCA technique is compared to KPCA by applying support vector machine (SVM) to evaluate the effectiveness of its performance in detecting damage. The proposed method is verified through numerical and full-scale studies (a Bridge Health Monitoring (BHM) Benchmark Problem and a cable-stayed bridge in China). The results demonstrate that the proposed method can detect the structural damage accurately and reduce false alarms by suppressing the effects and interference of environmental variations.