• 제목/요약/키워드: full-mode

검색결과 880건 처리시간 0.028초

Microwave Orbital Angular Momentum Mode Generation and Multiplexing Using a Waveguide Butler Matrix

  • Lee, Wangjoo;Hong, Ju Yeon;Kang, Min Soo;Kim, Bong Su;Kim, Kwang Seon;Byun, Woo Jin;Song, Myung Sun;Cho, Yong Heui
    • ETRI Journal
    • /
    • 제39권3호
    • /
    • pp.336-344
    • /
    • 2017
  • In this paper, we propose a convenient microwave orbital angular momentum (OAM) mode generation and multiplexing method operating in the 18 GHz frequency band, based on a $2{\times}2$ uniform circular array and a $4{\times}4$ Butler matrix. The three OAM modes -1, 0, and +1 were generated and verified using spatial S-parameter measurements; the measured back-to-back mode isolation was greater than 17 dB in the full 17 GHz to 19 GHz range. However, the radiated OAM beam centers were slightly dislocated and varied with both frequency and the mode index, because of the non-ideal characteristics of the Butler matrix. This resulted in mode isolation degradation and transmission distance limitations.

Multimode Hybrid Control Strategy of LLC Resonant Converter in Applications with Wide Input Voltage Range

  • Li, Yan;Zhang, Kun;Yang, Shuaifei
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.201-210
    • /
    • 2019
  • This paper proposes a multimode hybrid control strategy that can achieve zero-voltage switching of primary switches and zero-current switching of secondary rectifier diodes in a wide input voltage range for full-bridge LLC resonant converters. When the input voltage is lower than the rated voltage, the converter operates in Mode 1 through the variable-frequency control strategy. When the input voltage is higher than the rated voltage, the converter operates in Mode 2 through the VF and phase-shift control strategy until the switching frequency reaches the upper limit. Then, the converter operates in Mode 3 through the constant-frequency and phase-shift control strategy. The secondary-side diode current will operate in the discontinuous current mode in Modes 1 and 3, whereas it will operate in the boundary current mode in Mode 2. The current RMS value and conduction loss can be reduced in Mode 2. A detailed theoretical analysis of the operation principle, the voltage gain characteristics, and the realization method is presented in this paper. Finally, a 500 W prototype with 100-200 V input voltage and 40 V output voltage is built to verify the feasibility of the multimode hybrid control strategy.

Parametric Approaches to Sliding Mode Design for Linear Multivariable Systems

  • Kim, Kyung-Soo;Park, Young-Jin
    • International Journal of Control, Automation, and Systems
    • /
    • 제1권1호
    • /
    • pp.11-18
    • /
    • 2003
  • The parametric approaches to sliding mode design are newly proposed for the class of multivariable systems. Our approach is based on an explicit formula for representing all the slid-ing modes using the Lyapunov matrices of full order. By manipulating Lyapunov matrices, the sliding modes which satisfy the design criteria such as the quadratic performance optimization and robust stability to parametric uncertainty, etc., can be easily obtained. The proposed ap-proach enables us to adopt a variety of Lyapunov- (or Riccati-) based approaches to the sliding mode design. Applications to the quadratic performance optimization problem, uncertain systems, systems with uncertain state delay, and the pole-clustering problem are discussed.

Resonant vibration of piezoceramic plates in fluid

  • Lin, Yu-Chih;Ma, Chien-Ching
    • Interaction and multiscale mechanics
    • /
    • 제1권2호
    • /
    • pp.177-190
    • /
    • 2008
  • In this paper, both experimental measurement and theoretical analysis are used to investigate the out-of-plane resonant characteristics of a cantilevered piezoceramic plate in air and three different kinds of fluid. The experimental method, amplitude-fluctuation electronic speckle pattern interferometry (AF-ESPI), is the major technique used in this study to measure the resonant characteristics of the cantilivered piezoceramic plate. Both resonant frequencies and full-field mode shapes are obtained from this experimental technique. Numerical computations based on the finite element analysis are presented for comparison with the experimental results. Good quality of mode shapes for the cantilevered piezoceramic plate in air is obtained from the AF-ESPI technique. However, the quality decreases as the viscosity of fluids increases. From the results provided from experimental measurements and numerical computations, it is indicated that the resonant frequencies of the cantilevered piezoceramic plate in fluid decrease with the increase of the viscosity of fluids. Good agreements between the experimental measured data and the numerical calculated results are found for both resonant frequencies and mode shapes of the cantilevered piezoceramic plate in fluid.

Output Voltage Regulation for Harmonic Compensation under Islanded Mode of Microgrid

  • Lim, Kyungbae;Choi, Jaeho
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.464-475
    • /
    • 2017
  • This study examines a P+multi resonant-based voltage control for voltage harmonics compensation under the islanded mode of a microgrid. In islanded mode, the inverter is defined as a voltage source to supply the full local load demand without the connection to the grid. On the other hand, the output voltage waveform is distorted by the negative and zero sequence components and current harmonics due to the unbalanced and nonlinear loads. In this paper, the P+multi resonant controller is used to compensate for the voltage harmonics. The gain tuning method is assessed by the tendency analysis of the controller as the variation of gain. In addition, this study analyzes the slight voltage magnitude drop due to the practical form of the P+multi resonant and proposes a counter method to solve this problem by adding the PI-based voltage restoration method. The proposed P+multi resonant controller to compensate for the voltage harmonics is verified through the PSIM simulation and experimental results.

스펙트럼 영역에서의 마이크로스트립-슬롯 결합 선로 해석 (Analysis of a Coupled Microstrip-Slot Line in the Spectral Domain)

  • 이승엽;박한규
    • 한국통신학회논문지
    • /
    • 제19권3호
    • /
    • pp.553-559
    • /
    • 1994
  • 본 논문에서는 마이크로스트립-슬롯 결합 선로에 대한 Green함수를 스펙트럼 영역에서 유도하고, 수치적 결과를 정확히 얻기 위해 마이크로스트림 선로와 슬롯 부분에서의 전류분호에 대한 특이점을 고려한 기저함수를 이용한 Galerkin방법을 적용하여 선로의 특성 파라미터를 계산하였다. 특히, 마이크로스트림-슬롯 결합선로의 특성 중 마이크로스트립 선로에의한 우모드(even mode)와 슬롯에 의한 기모드(odd mode)의 특성에 의한 선로의 각 특성을 구하였고, 계산 결과값의 정확성을 비교하기 위해 기존의 데이터와 비교하였다.

  • PDF

폴링된 폴리머 광도파로의 광축을 조절하여 제작한 수동형 편광 변환기 (Passive Polarization Converter Fabricated by Controlling Optic Axis of Poled Polymer Waveguides)

  • 오민철;신상영
    • 전자공학회논문지A
    • /
    • 제32A권12호
    • /
    • pp.166-172
    • /
    • 1995
  • A novel passive TE/TM polarization mode converter is fabricated by using poled polymer waveguides. The optic axis of the poling induced waveguide is slowly rotated by using a slowly varying structure of poling electrodes. Thus the polarization conversion is achieved as the guided mode propagates through the waveguide. The proposed device is simulated by a full vectorial beam propagation method (VBPM) for anisotropic medium. For the rotation length of 1 mm, the TE polarization of the guided mode is successfully converted to the TM polarization with negligible loss. Based on the simulation results, we fabricated the polarization converter which is tested by using 1.3 $\mu$m laser diode. TE to TM mode conversion is observed with a polarization extinction ratio higher than 30 dB, and the excess loss is less than 1 dB. The polarization conversion is relatively insensitive to wavelength since the device contains no periodic structures. These devices are easier to fabricate than others containing periodic structures.

  • PDF

$TE^z_{mn}$ 모드정합법을 이용한 다중포트($2{\times}2$포트, 1포트) 직사각형 도파관의 일반화 산란행렬 추출 (Generalized Scattering Matrix of Multi-port($2{\times}2$port, 1port) Rectangular Waveguide Using $TE^z_{mn}$ Mode Matching Method)

  • 이준광;문상윤;박기언;허유강;조영기
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2003년도 종합학술발표회 논문집 Vol.13 No.1
    • /
    • pp.79-83
    • /
    • 2003
  • Multi-port($2{\times}2$port, 1port) rectangular waveguide discontinuity problem has been analyzed by use of $TE^x_{mn}$ (mono)mode matching method. Matrix size can be reduced significantly in comparison with $TE_{mn}&TM_{mn}$(full-wave)mode matching method. the present results is compared with those by CST MicroWave Studio to validate the presint method.

  • PDF

공진형 보조 회로를 이용한 연속 전류 모드 $S^4$-PFC 컨버터에 관한 연구 (A Study on the Continuous Current Mode $S^4$-PFC Converter using Auxiliary Resonant Circuit)

  • 한대희;김용;배진용;이은영;권순도
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.200-203
    • /
    • 2002
  • This paper presents Continuous-current mode of $S^4$-PFC(Single-Stage Single-switch Power Factor Correction) converter. Proposed converter operates in the continueous current mode(CCM) at full load and discontinuous current mode(DCM) at light load. So, characteristic of proposed converter is no bus voltage stress and Zero Voltage Switching(ZVS) using resonant auxiliary circuit. And. This paper presents characteristic of $S^4$-PFC converter and effect of circuit parameter of proposed converter through the input inductor, PFC capacitor's variation. All of these theory and characteristic verified through the experiment with a 72W(12V, 6A), $90^{kHz}$ prototype converter.

  • PDF

PID 형 슬라이딩모우드에 의한 전기.유압서보계의 위치제어에 관한 연구 (A Study on the Position Control of Electro-hydraulic Sevosystem using PID Sliding Mode)

  • 하석홍
    • 한국정밀공학회지
    • /
    • 제9권4호
    • /
    • pp.126-135
    • /
    • 1992
  • Up to now, there has been a lot of researches on the sliding mode control which has the insensitive characteristics to the variations of plant parameters, nonlinearities and external disturbances. One difficulty in applying the sliding mode control is the need for the knowledge of the full-state vector. The use of state observer is a natural step towards the relaxation of this condition. However, the exact plant-modeling is assumed to be known. Recently, there has been a remarkable advance in the microprocessor and one can construct the controller which could not realize due to hardware restriction in the past. Therefore in this paper, the PID sliding mode controller which has only one output feedback signal is suggested by means of microprocessor and the performance of electro-hydraulic servosystem compensated with this controller is proved.

  • PDF