• Title/Summary/Keyword: full scale experiments

Search Result 189, Processing Time 0.027 seconds

Strengthening of hollow brick infill walls with expanded steel plates

  • Cumhur, Alper;Altundal, Adil;Aykac, Sabahattin;Aykac, Bengi
    • Earthquakes and Structures
    • /
    • v.11 no.5
    • /
    • pp.887-904
    • /
    • 2016
  • An efficient, economical and practical strengthening method for hollow brick infill walls was proposed and investigated in the present study, experimentally and numerically. This method aims at increasing the overall lateral strength and stiffness of the structure by increasing the contribution of the infill walls and providing the non-bearing components of the structure with the capability of absorbing earthquake-induced energy to minimize structural damage during seismic excitations. A total of eleven full-scale infill walls strengthened with expanded mild steel plates were tested under diagonal monotonic loading to simulate the loading condition of the non-bearing walls during an earthquake. The contact surface between the plates and the wall was increased with the help of plaster. Thickness of the plates bonded to both faces of the wall and the spacing of the bolts were adopted as test parameters. The experiments indicated that the plates were able to carry a major portion of the tensile stresses induced by the diagonal loads and provided the walls walls with a considerable confining effect. The composite action attained by the plates and the wall until yielding of the bolts increased the load capacities, rigidities, ductilities and energy-absorption capacities of the walls, considerably.

Experiments for the Vibration Control of Steel Frame Structure Using Toggle Brace and Lead Rubber Damper (토글가새와 납-고무 제진장치를 적용한 구조물 진동제어 실험)

  • Park, Jung-Woo;Park, Jin-Young;Lee, Wan-Ha;Kim, Ki-Man;Park, Kun-Nok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.171-176
    • /
    • 2011
  • The purposes of the research were to evaluate system performance and response of building structure under external load for full scale modal-testing-tower applied toggle bracing and lead rubber damper(LRD). The dynamic properties of the structure were measured before and after installing damper under harmonic excitation using the AMD and the results were compared. The harmonic excitation condition is to increase 0.01Hz sine sweep signal from 0.49Hz to 0.63Hz. As a result of measuring resonant frequency, before installing damper is 0.55Hz and after installing damper is 0.62Hz. The experimental results after installing damper were also distinguished from simulation results and the main cause of this results is temperature dependency property of rubber material.

  • PDF

Large Capacity Passive Flow Control Vortex Valve (대용량 피동형 유량제어 와류 밸브)

  • Choi, N. H.;Chu, I.-C.;Chung, C. H.;Cho, B. H.;Song, C.-H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.635-640
    • /
    • 2004
  • The present paper provides the design specifications and working principle of flow controlling vortex valve which will be adopted in a Korean next generation reactor (APR1400). The vortex valve is installed inside the pressurized safety injection tank of APR1400, and it passively controls the water discharge flowrate from the tank. In the present study, the performance of the vortex valve have been evaluated throughout the repeated experiments in the full-scale test facility called VAPER(VAlve Performance Evaluation Rig). Based on the experimental results, it is confirmed that the currently developed vortex valve satisfies the major performance requirements of APR1400 plant design in view of the peak discharge flowrate, pressure loss coefficient, and total discharge duration time. To achieve the highest quality of the experimental results, a quality assurance program for vortex valve tests has been strictly applied.

  • PDF

A Study of a Correlation between Experiments and Calculations of Pressure Fluctuation on Hull Surface (선체 변동 압력에 관한 실험과 이론의 비교 연구)

  • Moon-Chan Kim;Ki-Sup Kim;In-Haeng Song
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.33 no.1
    • /
    • pp.19-26
    • /
    • 1996
  • An experimental and computational study of the pressure fluctuation induced by a propeller on a hull surface was carried out with three ship models and seven model propellers. The fluctuation of pressure on a flat plate was measured at KRISO cavitation tunnel and calculated by a panel and lifting surface method(XForShip code). To extend the measurement data on the flat plate into that on complex hull forms, the correction factor was determined as a ratio of the solid boundary factor(SBF). The computation of pressure fluctuation around complex hull forms was also performed to make the full scale prediction and compared with the corrected experimental data. The calculated values agreed well with the compensated experimental data and it was found that the correction factor was about 0.65-0.7.

  • PDF

Analytical evaluation of a modular CFT bridge pier according to directivity

  • Kim, Dongwook;Jeon, Chiho;Shim, Changsu
    • Steel and Composite Structures
    • /
    • v.20 no.6
    • /
    • pp.1193-1203
    • /
    • 2016
  • This paper focuses on the analytical behavior of modular circular concrete-filled tubular (CFT) column with enhanced bracing details. To design a full-scale bridge pier of multiple circular concrete-filled tubes, numerical analysis was used to evaluate structural performance according to load directivity. In previous research (Ma et al. 2012, Shim et al. 2014), low cycle fatigue failure at bracing joints was observed, so enhanced bracing details to prevent premature failure are proposed in this analysis. The main purpose of this research is to investigate seismic performance for the diagonal direction load without premature failure at the joints when the structure reaches the ultimate load. The ABAQUS finite-element software is used to evaluate experimental performance. A quasi-static loading condition on a modular bridge pier is introduced to investigate structural performance. The results obtained from the analysis are evaluated by comparing with load-displacement responses from experiments. The concrete-filled tubes with enhanced bracing details showed higher energy dissipation capacity and proper performance without connection failure for a diagonal load.

Experimental investigation for failure analysis of steel beams with web openings

  • Morkhade, Samadhan G.;Gupta, Laxmikant M.
    • Steel and Composite Structures
    • /
    • v.23 no.6
    • /
    • pp.647-656
    • /
    • 2017
  • This paper presents an experimental study on the behaviour of steel beams with different types of web openings. Steel beams with web openings became progressively more accepted as a well-organized structural form in steel construction since their existence. Their complicated design and profiling method provides better flexibility in beam proportioning for strength, depth, size and location of holes. The objective of this study is to carry out the experiments on steel beams with different types of web openings and performed non-linear finite element (FE) analysis of the beams that were considered in the experimental study in order to determine their ultimate load capacity and failure modes for comparison. Ten full scale models of steel beam with web openings have been tested in the experimental investigation. The finite element method has been used to predict their entire response to increasing values of external loading until they lose their load carrying capacity. FE model of each specimen that is utilized in the experimental studies is carried out. These models are used to simulate the experimental work to verify test results and to investigate the nonlinear behaviour of failure modes such as local buckling, lateral torsional buckling, web-post buckling, shear buckling and Vierendeel bending of beams.

Implementation of High Magnetization System for Performance Enhancement of Magnetic Flux Leakage Tool

  • Cho, Sung-Ho;Yoo, Hui-Ryong;Kim, Dong-Ku;Park, Dae-Jin;Rho, Yong-Woo;Seo, Kang;Park, Gwan-Soo;Choi, Doo-Hyun;Song, Sung-Jin
    • Journal of Magnetics
    • /
    • v.15 no.4
    • /
    • pp.199-203
    • /
    • 2010
  • This paper discusses the effectiveness of high magnetization saturation in ILI (In-Line Inspection) using an MFL (Magnetic Flux Leakage) tool, and introduces a practical method for improving the magnetization level together with the piggability. Thin steel plates, replacing the conventional wire brushes were used as conductors to transfer the magnetic flux to the pipe wall. The newly designed MFL tool was compared with the conventional version by means of FEM (Finite Element Method) analysis and full-scale experiments. In the results, the newly developed magnetization system obtained a stronger MFL signal amplitude, specially 2.7 times stronger, than that obtained by the conventional magnetization system for the same defect dimensions.

A Study on Surface Treatment and Configuration Design of Cellular Phone (핸드폰의 형상디자인과 표면처리에 대한 연구)

  • Lee, Jung-Hyun;Park, Jae-Won
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.3
    • /
    • pp.7-13
    • /
    • 2011
  • In Korea, the car mobile phone service had started in 1961 and with this Korea Mobile Telecommunications Services was established in 1984. Its service was mainly focused on the mobile phone service for the car which led the popularity of the full-scale mobile phone service. There are many kinds of materials, colors and patterns which are the elements of surface coating techniques. In light of that, we are focused on the UV coating that is ranked as an important part of the techniques in this study. In the first, the use of various materials for the cellular phone and surface processing techniques for the cellular phone were searched. On the basis of the results, the experiments of actual consumer experience with the exfoliation of the surface were done and through that we proposed the best way of processing the surface for the cellular phone and the materials. The result of the Wear Test showed that thick coating was detached more slowly and each company differed in their results with UV paints despite the same thickness of UV coating. The seal (UV) exfoliation of cellular phone is deeply related with the film thickness and the film formation when the users use the cellular phones and the exfoliation of the cellular phone surface will be decreased if the manufacturers meet the best conditions for the cellular phone.

Development of integrated test facility for human factors experiments in nuclear power plant (원자력발전소에서의 인간공학적 실험평가를 위한 종합 실험설비 개발)

  • 오인석;이현철;천세우;박근옥;심봉식
    • Journal of the Ergonomics Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.107-117
    • /
    • 1997
  • It is necessary to evaluate HMI inaspects of human factors in the design stage of MMIS(man machine interface system) and feedback the result of evaluation because operators performance is mainly influenced by the HMI. Therefore, the MMIS design should be reflected the operators psychological, behavioral and physiological characteristics in the interaction with human machine interface(HMI) in order to improve the safety and availability of the MMIS of a nuclear power plant(NPP) by reduction of human error. The development of human factors experimental evaluation techniques and integrated test facility(ITF) for the human factors evaluation become an important research field to resolve hi,am factors issues on the design of an advanced control room(ACR). We developed am ITF, which is aimed to experiment with the design of the ACR and the human machine interaction as it relates to the control of NPP. This paper presents the development of an ITF that consists of three rooms such as main test room(MTR), supporting test room(STR) and experiment control room(ECR). And, the ITF has a various facilities such as a human machine simulator(HMS), experimental measurement systems and data analysis and experiment evaluation supporting system(DAEXESS). The HMS consists of full-scope simulation model of Korean standard NPP and advanced HMI based on visual display nits (VDUS) such as touch color CRT, large scale display panel(LSDP), flat panel display unit and so on.

  • PDF

UV Immune System of Personalized Space (개별공간의 자외선 살균 시스템)

  • Jeong, Ky-Bum;Choi, Sang-Gon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.63-70
    • /
    • 2009
  • The air sterilization systems are investigated experimentally in this paper. The goal is to reduce bacteria, mold and viruses in office air by using a UV sterilizer installed inside a partition panel and wall-mounted unit. These systems allow occupants to turn the system on/off and to control the incoming air speed and direction. The partition air sterilization system conditions and sterilizes the air, and then delivers the clean air into the personal task area through the partition panels, which are connected to the pressurized under-floor plenum. Room air exits through the return grills mounted on the ceiling. The wall-mounted air sterilization system sterilizes the air, and then delivers the clean air to the personal task area from the wall. In this study a full-size experimental environment is established to investigate the immunization performance of these air sterilization systems. A typical office space scale is used in this study in order to find an optimal system to achieve a sterilized healthy micro-environment. Multiple system parameters, including volume flow rate and velocity of supplied air, were regulated during the experiments. The more air contact these air sterilization systems had, the better disinfection performance. Over 90% of eradication ratios were obtained by these two air sterilization systems. The results indicate that these systems can efficiently disinfect office air contamination.