Dielectric Barrier Discharge for Ultraviolet Light Generation and Its Efficient Driving Inverter Circuit

  • Oleg, Kudryavtsev;Ahmed, Tarek;Nakaoka, Mutsuo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.3
    • /
    • pp.101-105
    • /
    • 2004
  • The efficient power MOSFET inverter applied for a simple and low cost power supply is proposed for driving the dielectric barrier discharge (DBD) lamp load. For decades, the DBD phenomenon has been used for ozone gas production in industry. In this research, the ultraviolet and visible light sources utilizing the DBD lamp is considered as the load for solid-state high frequency power supply. It is found that the simple voltage-source single-ended quasi-resonant ZVS inverter with only one active power switch could effectively drive this load with the output power up to 700 W. The pulse density modulation based control scheme for the single-ended quasi-resonant ZVS inverter using a low voltage and high current power MOSFET switching device is proposed to provide a linear power regulation characteristic in the wide range 0-100% of the full power as compared with the conventional control based Royer type parallel resonant inverter type power supplies.

Practical Photovoltaic Simulator with a Cross Tackling Control Strategy Based on the First-hand Duty Cycle Processing

  • Wang, Shuren;Jiang, Wei;Lin, Zhengyu
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.1018-1025
    • /
    • 2015
  • This paper proposes a methodological scheme for the photovoltaic (PV) simulator design. With the advantages of a digital controller system, linear interpolation is proposed for precise fitting with higher computational efficiency. A novel control strategy that directly tackles two different duty cycles is proposed and implemented to achieve a full-range operation including short circuit (SC) and open circuit (OC) conditions. Systematic design procedures for both hardware and algorithm are explained, and a prototype is built. Experimental results confirm an accurate steady state performance under different load conditions, including SC and OC. This low power apparatus can be adopted for PV education and research with a limited budget.

Improvement of Transient Characteristics of Brush-less Type Synchronous Generator for Emergency Driven by Internal-Combustion Engine (내연기관 구동 비상용 브러시리스형 동기발전기의 과도특성 개선)

  • An, Young-Joo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.4
    • /
    • pp.268-272
    • /
    • 2016
  • A brush-less type synchronous generator is driven by an internal-combustion engine that is used for emergency source. This kind of generator has to maintain output voltage in a range of some degree under the abrupt load irregular conditions such as a full load trip. This paper suggests a suppression method of increasing the output voltage over the rating. Automatic voltage regulator detects excessive rising of output voltage of the generator and supplies the signals to a switch installed in the rotating exciter through the photo-coupler. The current of main field rapidly decreases by additional resistor of the main filed circuit. Therefore, the output voltage of the generator is maintained effectively. The experimental results verified that the excessive value of the output voltage is limited in the range of 7% of the rated voltage.

The study of frictional damper with various control algorithms

  • Mirtaheri, Masoud;Samani, Hamid Rahmani;Zandi, Amir Peyman
    • Earthquakes and Structures
    • /
    • v.12 no.5
    • /
    • pp.479-487
    • /
    • 2017
  • Frictional dampers are used in structural engineering as means of passive control. Meanwhile, frictional damper shave a disadvantage compared to viscous rivals since the slippage force must be exceeded to activate the device, and cannot be ideal full range of possible events. The concept of semi-active control is utilized to overcome this shortcoming. In this paper, a new semi-active frictional damper called Smart Adjustable Frictional (SAF) damper is introduced. SAF damper consists of hydraulic, electronic units and sensors which are all linked with an active control discipline. SAF acts as a smart damper which can adapt its slippage threshold during a dynamic excitation by measuring and controlling the structural response. The novelty of this damper is, while it controls the response of the structure in real time with acceptable time delay. The paper also reports on the results of a series of experiments which have been performed on SAF dampers to obtain their prescribed hysteretic behavior for various control algorithms. The results show that SAF can produce the desired slippage load of various algorithms in real time. Numerical models incorporating control simulations are also made to obtain the hysteretic response of the system which agrees closely with test results.

A Review of EOS Thermal Control Logic for MSC on KOMPSAT-2

  • Heo H.P.;Kong J.P.;Kim Y.S.;Park J.E.;Youn H.S.;Paik H.Y.
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.452-455
    • /
    • 2004
  • MSC (Multi-Spectral Camera) system is a remote sensing instrument to obtain high resolution ground image. EOS (Electro-Optic System) for MSC mainly consists of PMA (Primary Mirror Assembly), SMA (Secondary Mirror Assembly), HSTS (High Stability Telescope Structure) and DFPA (Detector Focal Plane Assembly). High performance of EOS makes it possible for MSC system to provide high resolution and high quality ground images. Temperature of the EOS needs to be controlled to be in a specific range in order not to have any thermal distortion which can cause performance degradation. It is controlled by full redundant CPU based electronics. The validity of thermistor readings can be checked because a few thermistors are installed on each control point on EOS. Various kinds of thermal control logics are used to prevent 'Single Point Failure'. Control logic has a few set of database in order not to be corrupted by SEU (Single Event Upset). Even though the thermal control logic is working automatically, it can also be monitored and controlled by ground-station operator. In this paper, various ways of thermal control logic for EOS in MSC will be presented, which include thermal control mode and logic, redundancy design and status monitoring and reporting scheme.

  • PDF

Improvement of Transient Performance of Synchronous Generator using Feedforward Controller (피드포워드 제어기를 사용한 동기발전기의 과도특성 개선)

  • An, Young-Joo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.2
    • /
    • pp.57-62
    • /
    • 2018
  • A brush-less type synchronous generator driven by an internal-combustion engine is used for emergency electric source. These types of generators have to maintain a certain range of output voltage even under the sudden load change conditions such as full load application and removal. This paper describes a method for suppressing the output voltage of a synchronous generator that operates excessively when the load fluctuates. The method used in this paper is a feedforward control method in which the main voltage control consists of a feedback loop using a typical PID controller and the load current is detected as a disturbance element and compensated directly. A feedforward system is constructed in which the load current is regarded as disturbance, and the appropriate feedforward controller configuration and parameters are found through simulation. Finally, it can be seen through the experiment that the feedforward control is performed properly. It can be seen that the generator terminal voltage is recovered to the steady state in a short period of time as compared with the existing PID control method even when the entire load of the generator is changed.

Seismic control of concrete buildings with nonlinear behavior, considering soil structure interaction using AMD and TMD

  • Mortezaie, Hamid;Zamanian, Reza
    • Structural Engineering and Mechanics
    • /
    • v.77 no.6
    • /
    • pp.721-734
    • /
    • 2021
  • The seismic analysis of structures without applying the effects of soil can undermine functional objectives of structure so that it can affect all the desired purposes at the design and control stages of the structure. In this research, employing OpenSees and MATLAB software simultaneously and developing a definite three-dimensional finite element model of a high-rise concrete structure, designed using performance-based plastic design approach, the performance of Tuned Mass Damper (TMD) and Active Mass Damper (AMD) is both examined and compared. Moreover some less noted aspects such as nonlinear interaction of soil and structure, uplift, nonlinear behavior of structure and structural torsion have received more attention. For this purpose, the analysis of time history on the structural model has been performed under 22 far-field accelerogram records. Examining a full range of all structural seismic responses, including lateral displacement, acceleration, inter-story drift, lost plastic energy, number of plastic hinges, story shear force and uplift. The results indicate that TMD performs better than AMD except for lateral displacement and inter-story drift to control other structural responses. Because on the one hand, nonlinear structural parameters and soil-structure interaction have been added and on the other hand, the restriction on the control force applied that leads up to saturation phenomenon in the active control system affect the performance of AMD. Moreover, the control force applied by structural control system has created undesirable acceleration and shear force in the structure.

A Study on Status of Student Health Service in Universities and Colleges in Korea (우리나라 대학(大學) 학생보건관리실태(學生保健管理實態)에 관(關)한 조사연구(調査硏究))

  • Kwun, Byung-Nim;Choi, Sam-Sop
    • Journal of Preventive Medicine and Public Health
    • /
    • v.12 no.1
    • /
    • pp.3-12
    • /
    • 1979
  • A survery was carried out in order to know the status of student health service and student medical insurance of universities and colleges in Korea from 1 July to 30 September. 1978. And the following results were obtained; 1. Out of seventy universities and colleges, 54.8% of them had student health service facility such as student health conte. (30.0%) or health room (24.8%). 2. Out of twenty-seven national and public universities and colleges, 44.4% of them had student health service facility and out of forty-three private universities and colleges, 60.5% of them had student health service facilities. 3. Each of 80.0% of 25 universities, 43.3% of 30 colleges and 33.3% of 15 junior colleges had student health service facility. 4. Major roles of student health service were physical examination (92.1%), health counselling (86.8%), primary medical care (78.9%), tuberculosis control (68.4%), insect and rodent control (52.6%), parasite control(47.4%), water source sanitation (44.7%), and dental health care (28.9%). 5. Out of 21 universities and colleges, 66.7% of them had full time doctor and 81.0% of them had full time nurse for student health center. And out of 17 universites and colleges, 5.9% of them had full time doctor and 33.3% of then had full time nurse for student health room. 6. The range of health fee was varied from 100 won to 1,400 won per student per semester and the average was 520 won. 7. Among 55 universities and colleges, 78.6% of them had carried out annual physical examination in 1977 and the rate of physical examination was 57.4%. 8. Out of 70 universities and colleges. 45.7% of them had tuberculosis control program and the prevalence rate was 6.0 per 1,000 students. 9. Student medical insurance program was developed by ten universities and one college among 25 universities and 45 colleges. 10. Student medical insurance benefit was varied according to university and college; the reduction rate of medical fee was 20% to 80% for not only in-patient but also out-patient. 11. The upper limit of pay claim was varied according to the university and college from 5,000 won to no-limitation for out-patient and from 30,000 won to no-limitation for in-patient. 12. The highest utility rate of student medical insurance program was found in university 'F' with the rate of 791 for out-patient and 12 for admitted patient per 1,000 students.

  • PDF

EFFECTS OF DIETARY FULL-FAT SOYBEAN LEVELS ON GROWTH PERFORMANCE AND FEED UTILIZATION AND PHOSPHORUS EXCRETION OF CARP (Cyprinus carpio)

  • Kim, J.D.;Kim, K.S.;Song, J.S.;Woo, Y.B.;Jeong, K.S.;Won, T.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.8 no.6
    • /
    • pp.587-594
    • /
    • 1995
  • In order to estimate the nutritive value of roasted full-fat soybean (FFS) in carp diet, growth performance and excretion of protein and phosphorus were examined using carps having mean body weight of 111 g. Growth trial was conducted for 4 weeks using the fishes fed 5 diets (Control, $F_{24}S_{13}$, $F_{16}S_{27}$, $F_8S_{40}$ and $F_0S_{56}$) containing 32%, 24%, 16%, 8% and 0% of fish meal (F) and 0%, 13%, 27%, 40% and 56% of full-fat soybean, respectively. A total of 800 fishes were allotted randomly by groups of 40 to 5 treatments with 4 replicates per treatment. Fishes were fed to station eight times daily. Feeding trial was conducted for 4 weeks. As dietary FFS increased from 0% to 56%, weight gain of fish decreased from 91 g to 39 g and feed conversion ratio increased from 1.06 to 1.95. Protein efficiency ratio (PER) was highest (2.35) in control group which had the highest protein intake, while PER significantly decreased with decrease in protein intake as dietary FFS level increased. Although dietary protein and energy levels were maintained constant, protein excretion per kg weight gain varied from 273 g to 579 g for the groups control and $F_0S_{56}$, respectively. However, the value for control group was not significantly different to those for the groups $F_{24}S_{13}$ and $F_{16}S_{27}$. On the other hand, the highest protein retention efficiency was found in group fed the diet $F_{24}S_{13}$. Fish fed the diet $F_8S_{40}$ excreted the lowest phosphorus (P) based on kg weight gain showing the highest P retention efficiency of 62%. P excretion per kg feed intake was in the range of 5 g to 10 g for the groups $F_8S_{40}$ and $F_{24}S_{13}$, respectively. The present results indicated that as dietary FFS level increased, growth performance and feed utilization decreased while excretion of protein and phosphorus increased. Therefore, it was concluded that more than 25% substitution by FFS for fish meal could exert negative effects on growth and feed utilization of carp.

Performance Improvement of Power Control System for Driving MGT

  • Lee Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.7
    • /
    • pp.744-749
    • /
    • 2005
  • This paper describes the performance improvement of power control system of magnetron (MGT) for microwave oven. The MGT is used extensively in household microwave oven and industrial microwave heating devices, and is operated by 3.0[kV] $\∼$5.0[kV] dc high voltage. The proposed power supply is consisted of a bridge rectifier, step-up converter(SUC) and its controller, half bridge inverter(HBI) and its controller, and full wave double voltage rectifier(DVR). In the proposed system, a good power factor can be obtained by the SUC' switching method that the inductor current waveforms follows that of the rectified voltage, and a line input power can be controlled to a range of 17.5[$\%$] by duty ratio (DR) adjustment of the HBI.