• Title/Summary/Keyword: full bridge inverter

Search Result 295, Processing Time 0.028 seconds

2MHz, 2kW RF Generator (2MHz, 2kW RF 전원장치)

  • Lee J.H.;Choi D.K.;Choi S.D.;Choi H.Y.;Won C,Y.;Kim S.S
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.260-263
    • /
    • 2003
  • When ICP(Inductive Coupled Plasma type etching and wafer manufacturing is being processed in semiconductor process, a noxious gas in PFC and CFC system is generated. Gas cleaning dry scrubber is to remove this noxious gas. This paper describes a power source device, 2MHz switching frequency class 2kW RF Generator, used as a main power source of the gas cleaning dry scrubber. The power stage of DC/DC converter is consist of full bridge type converter with 100kHz switching frequency Power amplifier is push pull type inverter with 2MHz switching frequency, and transmission line transformer. The adequacy of the circuit type and the reliability of generating plasma in various load conditions are verified through 50$\Omega$ dummy load and chamber experiments result.

  • PDF

A Load Identification Method for ICPT System Utilizing Harmonics

  • Xia, Chen-Yang;Zhu, Wen-Ting;Ma, Nian;Jia, Ren-Hai;Yu, Qiang
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2178-2186
    • /
    • 2018
  • Online identification of load parameters is the premise of establishing a stable and highly-efficient ICPT (Inductive Coupled Power Transfer) system. However, compared with pure resistive load, precise identification of composite load, such as resistor-inductance load and resistance-capacitance load, is more difficult. This paper proposes a method for detecting the composite load parameters of ICPT system utilizing harmonics. In this system, the fundamental and harmonic wave channel are connected to the high frequency inverter jointly. The load parameter values can be obtained by setting the load equation based on the induced voltage of secondary-side network, the fundamental wave current, as well as the third harmonic current effective value received by the secondary-side current via Fourier decomposition. This method can achieve precise identification of all kinds of load types without interfering the normal energy transmission and it can not only increase the output power, but also obtain higher efficiency compared with the fundamental wave channel alone. The experimental results with the full-bridge LCCL-S type voltage-fed ICPT system have shown that this method is accurate and reliable.

High precision Automatic Voltage Regulator by using series transformer (직렬 변압기를 이용한 고정밀 자동전압조절기)

  • Zhang, Lei;Lee, Hwa-Chun;Jung, Tae-Uk;Nam, Hae-Kon;Nam, Soon-Ryul;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.574-576
    • /
    • 2008
  • Now there are two types Non-contact compensation AC automatic voltage regulator (A.V.R). One is transformer compensation regulator, whose principle is the combination of multiple compensation transformers, do the compensation by turning on and off the connections of the transformer through the multi-full bridge circuit. This method removed the mechanical drive and contacts, which increases the life and the dynamic performance of the A.V.R. However, the compensation is multilevel, and it needs many compensation transformers and switches, the circuit is complex, the compensation precision is low. Another type is PWM switch AC regulator, whose principle is getting the AC voltage from the input, then induce the AC compensation voltage through commutating and high frequency PWM transforming, and phase tracking. Here the compensation is step-less, the compensation precision is high, and the response is fast. But the circuit is complex, and it needs an inverse compensation transformer, which is difficult to realize high-power applications. In this paper, it shows an Automatic Voltage Regulator which use high frequency PWM inverter do compensation. This A.V.R has the function as the custom-power, which make the performance of the power supply in a high level.

  • PDF

The Realization of a Single-Phase Parallel Active Power Filter to Eliminate Harmonics of Source Current Generated by Nonlinear Loads (비선형부하에 의해 발생한 전원 전류의 고조파를 제거하기 위한 단상 병렬형 Active Power Filter의 구현)

  • Jang, Mok-Soon;Lee, Hu-Chan;Kim, Sang-Hoon;Park, Jong-Yeon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.220-221
    • /
    • 2006
  • This paper presents a single-phase parallel active power filter with an analog control circuit to eliminate for harmonic source currents generated by nonlinear loads. The proposed system removes the harmonic source currents by injecting a compensation current that is 180' out of phase with the load harmonic current. The detection of the load harmonics is realized by a simple new structure, referred to the Notch Filter with GIC (Generalized Impedance Converter), which has higher Q than existing harmonic detecters and a simpler structure. The compensation current is obtained using the proposed harmonic detection circuit, DC-Link voltage, and output current of the full-bridge inverter controlled current mode PWM controller. The operation of the proposed system is verified experimentally.

  • PDF

Development of 6kW ZVS Boost Converter by 4-Parallel Operation (4-병렬 제어 기법을 적용한 6kW 영전압 스위칭 승압형 컨버터 개발)

  • Rho, Min-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.86-92
    • /
    • 2009
  • This paper presents development of 6kw ZVS(Zero Voltage Switching) boost converter by 4-parallel operation. To realize a high capacity converter with 6 kw, 4-parallel operation of 1.5kW unit module is proposed in this paper. To meet high ratio input to output voltage, isolated type booster converter is designed. To achieve ZVS operation of 4-switches of full bridge and protect a voltage overshoot caused by switch turn-off, simple active-clamp circuit is applied to the primary side. For parallel operation of 4-modules, master-slave control method is proposed to achieve input current sharing of 4-unit converter modules accurately. For performance tests, simulation is carried out. Also, load and experimental tests of the developed booster converter, 230Vdc/6kW, are carried out under various conditions. For field tests, the developed converter is applied for boosting a battery power to high DC_link voltage for a VSI inverter which starts a micro-turbine(MT) installed in vehicle and it's performance is verified through high speed motoring a MT up to tens of thousands of rpm.

Comparative study of proportional-integral, proportional-resonant, and predictive deadbeat controllers in a PV PCS (태양광 전력변환장치의 PI, PR 및 PD 제어기 비교 연구)

  • Le, Dinh-Vuong;Kim, Chang-Soon;Hwang, Chul-Sang;Park, Minwon;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1050-1051
    • /
    • 2015
  • In industry, there are several different controllers which can be implemented for power conditioning systems (PCS) such as proportional-resonant (PR), predictive deadbeat (PD), or proportional-integral (PI) controller. But there are not any comparison studies about these controllers. To investigate the differences between the three types of the controllers, this paper presents a comparative study of PR, PI, and PD controllers in a photovoltaic (PV) PCS. These controllers are designed mathematically and simulated for the comparative analysis. The PI controller is designed in the rotating reference (dq) frame. The PR and PD controllers are implemented in the natural (abc) reference frame. The PCS is composed of a DC-DC boost converter and a full bridge inverter. The filter of the PCS is an LCL filter including a passive damping resistor. The parameters of PCS are 3 kW, 25 kHz switching frequency and 220 V-60 Hz grid voltage. The comparison results between these controllers for the grid-connected PCS are clearly shown. The simulation results demonstrate the detailed characteristics of each controller for the PV PCS in order to choose the controller for individual target properly.

  • PDF

Design Method of Adaptive Ignitor for HID Lamps (HID 램프를 위한 상태 적응형 점화기 설계 방법)

  • Jo, Gye-Hyun;Song, Myoung-Suk;Park, Chong-Yeun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.7-14
    • /
    • 2004
  • The metal halide lamps are now widely used in the application and commercial lighting due to their attracting properties such as good color rendering and high efficiency. But, they have a serious problem of acoustic resonance using high frequency operation and they need a high voltage to ignite. So, they have not been applied to indoors. Over the past few years, a considerable number of studies have been conducted on the electronic ballast with hot restarting and resonance phenomenon. But, Very few attempts have been made at adaptive ignition method according to lamp state. In this paper is proposed electronicballast for metal halide lamps with an igniter for adaptive ignition. The proposed electronic bllast can generate a different ignition voltage according to the arc tube state.

The Development Of the Electronic Ballast for HPS lamp using the RCD Snubber and Quasi-Square Wave (RCD 스너버 및 준구형파를 이용한 250[W] HPS lamp용 전자석 안정기 개발)

  • 강도형;박종연
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.18-25
    • /
    • 2002
  • In this paper, We have researched about the Electronic Ballast for 250W HPS(High Pressure Sodium) lamp. This Electronic Ballast is capable to operate the Ignition and Steady State Using the Class D LCC resonant tank, and minimizing the full-bridge inverter's Switching Stress by implementation Quasi-square ZC-ZVS Soft Switching Method. And also, We have reduced the heat of MOS-FETs and high frequency switching surge noise using the RCD damp snubber. Therefore, We are sure that the developed ballast has the properties of the stable & reliable Control and the function of minimizing the total noise of the system.

Fuzzy logic Controlled Electronic Ballast for HID Lamps (HID 램프용 퍼지제어 전자식 안정기)

  • Kim, Byeong-Cheol;Cha, Hyeon-Rok;Kim, Gwang-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.10
    • /
    • pp.587-594
    • /
    • 2002
  • A low frequency square wave electronic ballast for the high intensity discharge(HID) lamps using fuzzy logic controller is developed. This electronic ballast consists a buck converter, a low frequency square wave full bridge inverter, a high voltage pulse generator for the HID lamp ignition, an over current protection circuit and an 8-bit microcontroller. The ballast system is operated on the constant current mode during the HID lamp start-up process and the system is operated on the constant power mode during steady state. Experimental results show that the fuzzy logic control operation is carried out successfully by the 8-bit microcontroller PIC16F877 In this electronic ballast system, in spite of the limited control bandwidth caused by low operating speed of the microcontroller, the good performance in the constant lamp current characteristic is obtained. Acoustic resonance of the HID lamps can be effectively avoided because the instantaneous In lamp power is fully constant due to the low frequency square wave drive.

Phase-Shift Full-Bridge DC/DC Converter with Fixed-Phase Operation Inverter (고정 위상 동작 인버터를 포함하는 위상천이 풀 브리지 DC/DC 컨버터)

  • Kim, Jin-Ho;Park, Jae-Sung;Kim, Hong-Kwon;Park, Jun-Woo;Shin, Yong-Saeng;Ji, Sang-Keun;Cho, Sang-Ho;Roh, Chung-Wook;Hong, Sung-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.335-336
    • /
    • 2012
  • 본 논문에서는 출력 인덕터 전류의 리플을 저감할 수 있는 새로운 방식의 위상천이 풀 브리지 컨버터를 제안한다. 제안된 회로는 2개의 풀 브리지 인버터가 연결된 구조로 되어 있으며 하나의 풀 브리지 인버터가 고정 위상($0^{\circ}$)으로 동작할 때, 다른 풀 브리지 인버터의 위상을 조절하여 출력 전압을 제어하는 방식이다. 정상 동작 시, 제안회로는 기존 위상천이 풀 브리지 컨버터에 비해 출력 인덕터 전류 리플이 매우 작고, 2차 측 정류기의 공진 전압도 작아져 출력 LC 필터의 소형화 및 고효율화가 가능하여 대전류 사양에 매우 적합한 장점을 갖는다. 본 논문에서는 제안된 회로의 이론적인 특성을 분석하고, 450W 전원장치를 시작품으로 제작하여 그 우수성을 확인하였다.

  • PDF