• Title/Summary/Keyword: full bridge inverter

Search Result 295, Processing Time 0.027 seconds

Self-Discharge Effects on Multi-Lamps Backlight Driven by a High Speed Switching Inverter

  • Kwon, Nam-O;Kim, Young-M;Kim, Sung-J;Cho, Tae-Sung;Cho, Guang-Sup;Kim, Bong-Soo;Kang, June-G
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.539-540
    • /
    • 2002
  • A self-discharge in multi-EEFLs and CCFLs has been found to provide a high luminance and efficiency. With a fast rising and falling times of $2{mu}s$, and the peak voltage over 1.6KV, the self-discharge occurs in EEFLs and CCFLs driven by a full bridge switching inverter. Particularly in CCFLs connected with a typical value of ballast capacitance, a self-discharge follows by the main discharge when the voltage falls to the ground.

  • PDF

The Development of the Buck Type Electronic Dimming Ballast for 250W MHL

  • Jung, Dong-Youl;Park, Chong-Yeon
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.4
    • /
    • pp.496-502
    • /
    • 2006
  • In this paper, we studied the development of the electronic ballast for 250W MH (Metal-Halide) lamps. We were able to improve the input power factor by using a PFC IC. To provide the lamp with the rated voltage required, we used the buck-type dc-dc converter. The stress of the switching devices in the inverter could be reduced by this method. To eliminate the acoustic resonance phenomena of MH lamps, the voltage of the lamp added the high frequency sine-wave to the low frequency square-wave by using the full bridge typed inverter. We have developed a simple igniter using the L and C elements. We could control the dimness of the lamp by varying the output voltage of the buck converter. The buck converter output voltage could be controlled by using a microprocessor.

Design and characteristics analysis of Double resonant type High frequency Inverter using Phasor shift (복 공진형 고주파 인버터의 특성해석과 설계)

  • Kim, Jong-Hae;Won, Jae-Sun;Kim, Dong-Hee;Cho, Kyu-Phan;Sim, Kwang-Yul;Lee, Bong-Seop
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2100-2102
    • /
    • 1998
  • A full bridge double resonant type inverter using Phasor shift suitable for heating magnetic and nonmagnetic at high frequency is described. A series-parallel arrangement of capacitor is adopted and optimum mode of operation is proposed. Also, Based on the characteristics value, a method of circuit design is proposed.

  • PDF

Maximum Power Point Tracking Photovoltaic Invert (최대전력 추적 태양광 인버터 시스템)

  • Kim, Man-Sig;Kim, Sil-Keun;Hong, Jung-Pyo;Hong, Soon-Ill
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1191-1192
    • /
    • 2006
  • This paper propose method of maximum power point tracking using boost converter for a connected single phase inverter. The maximum power point tracking control is based on generated circuit control MOSFET switch of two boost converter and single phase inverter uses predicted current control to control four IGBT's switch in full bridge. The predicted current control provide current with sinusoidal wave shape and inphase with voltage.

  • PDF

Development of 60KV Pulse Power Supply using IGBT Stacks (IGBT 직렬구동에 의한 60KV 펄스 전원장치 개발)

  • Ryoo, H.J.;Kim, J.S.;Rim, G.H.;Sytykh, D.;Gussev, G.I.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.917-918
    • /
    • 2006
  • In this paper, a novel new pulse power generatorbased on IGBT stacks is proposed for pulse power application. Proposed scheme consists of series connected 9power stages to generate maximum 60kV output pulse and one series resonant power inverter to charge DC capacitor voltage. Each power stages are configured as 8 series connected power cells and each power cell generates up to 850VDC pulse. Finally pulse output voltage is applied using total 72 series connected IGBTs. The synchronization of gating signal is importantfor series operation of IGBTs. For gating signal synchronization, full bridge inverter and pulse transformer generates on-off signals of IGBT gating and specially designed gate power circuit was used.

  • PDF

Modeling and Analysis of Three Phase PWM Converter (3상 PWM 컨버터의 모델링 및 해석)

  • 조국춘;박채운;최종묵
    • Proceedings of the KSR Conference
    • /
    • 1999.05a
    • /
    • pp.328-335
    • /
    • 1999
  • Three phase full bridge rectifier has been used to obtain dc voltage from three phase ac voltage source. The rectifier system has drawbacks that power factor is low and power flow is unidirectional. Therefore, when dc voltage increases due to regeneration of power the dynamic resister for dissipation of regeneration power must be installed. But three phase PWM converter can be controlled to operate with unity power factor and bidirectional power flow. Therefore when the PWM converter is used as do supply system, the dissipating resistor is not necessary. On this thesis, in order to design a controller having good performance, the hee phase PWM converter is completely modeled by using circuit DQ-transformation and thus a general and simple instructive equivalent circuit is obtained; the inductor set becomes a second order gyrator-coupled system and three phase inverter becomes a transformer as well. Under given phase angle(${\alpha}$) and modulation index(MI) of the three phase inverter, the dc and ac characteristics are obtained by analysis of the transformed equivalent circuit The validity of the equivalent circuit is confirmed through PSPICE simulation. And based on the dc and ac characteristics a controller with unity power factor is proposed.

  • PDF

A Study on the Electrical Fan Heater using High Efficiency Induction Heating (고효율 유도가열형 전기온풍기에 관한 연구)

  • Shin, Dae-Chul;Woo, Hyoung-Gyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.3
    • /
    • pp.24-30
    • /
    • 2012
  • A proposed the electrical fan heater using induction heating is innovative system which applied IH(Induction Heating) magnetic induction heating generated from induction-heated metallic package and high-frequency power circuit technique for thermal converse technique. In this occurs not burning, so that the working environment and deterioration of products can be improved. The existing heater that low efficiency by heated resistance or using fossil fuel of coal, diesel, kerosene has problems about burden for high cost price. In this paper are compared efficiency the existing heaters and designed electrical fan heaters using 3[kW]-Class full-bridge resonant inverter. In addition, action analysis and application of system are discussed.

The development of power supply for dry scrubber (건식 세정기용 전원장치 개발)

  • 김수석;원충연;최대규;최상돈
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.5
    • /
    • pp.394-399
    • /
    • 2001
  • In this Paper, the development of the power supply for dry scrubber is discussed. 1500w, 100kHz power supply Is designed and tested. The main power stage is used for the FB PWM inverter with an LC filter in the secondary circuit. The operation characteristics of power supply are verified by simulation and experimental results.

  • PDF

A Study on Reactor Capacitance Estimation Algorithm and 5kW Plasma Power Supply Design for Linear Output Control of Wide Range (넓은 범위의 선형 출력 제어를 위한 5kW 플라즈마 전원장치 설계 및 반응기 커패시턴스 추정 알고리즘의 관한 연구)

  • Noh, Hyun-Kyu;Lee, Jun-Young;Kim, Min-Jea
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.6
    • /
    • pp.514-524
    • /
    • 2016
  • This work suggests a study on 5 kW plasma power supply design and reactor capacitance estimation algorithm for a wide range of linear output control to operate a plasma reactor. The suggested study is designed to use a two-stage circuit and control the full-bridge circuit of the two-stage circuit using the buck converter output voltage of the single-stage circuit. The switching frequency of the full-bridge circuit is designed to operate through high-frequency switching and obtain maximum output using LC parallel resonance. Soft switching technique(ZVS) is used to reduce the loss caused by high-frequency switching, and duty control of the buck converter is applied to control a wide range of linear output. The internal capacitance of the reactor cannot easily be extracted, and thus, the reactor cannot be operated in an optimized resonant state. To address this issue, this work designs the internal capacitance of the reactor such that estimations can be performed with the developed reactor capacitance estimation algorithm applied to the internal capacitance of the reactor. A 5 kW plasma power supply is designed for a wide range of linear output control, and the validity of the study on the reactor capacitance estimation algorithm is verified.

The Characteristics Analysis and Design of High-Frequency Isolated Type ZVZCS PS-PWM DC-DC Converter with Fuel Cell Generation System (연료전지 발전시스템에 적용된 고주파 절연형 ZVZCS PS-PWM DC-DC 컨버터의 설계 및 특성 해석)

  • Suh, Ki-Young;Mun, Sang-Pil;Kim, Dong-Hun;Lee, Hyun-Woo;Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.21-28
    • /
    • 2006
  • In this paper, the proposed full-bridge high frequency isolated zoo voltage and zero current switching phase shifted pulse width modulation(ZVZCS PS-PWM)DC-DC converter among fuel cell generation system consist of 1.2[kW] fuel cell of Nexa Power Module, full-bridge DC-DC converter to boost the fuel cell low voltage($28{\sim}43[%]$) to 380[VDC] and a single phase full-bridge inverter is implemented to produce AC output(220[VAC], 60[Hz]). A tapped inductor filter with freewheeling diode is newly implemented in the output filter of the proposed full-bridge high frequency isolated ZVZCS PS-PWM DC-DC converter to suppress circulating current under the wide output voltage regulation range, thus to eliminate the switching and transformer turn-on/off over-short voltage or transient phenomena. Besides the efficiency of $93{\sim}97[%]$ is obtained over the wide output voltage regulation ranges and load variations.