• 제목/요약/키워드: frictional damper

검색결과 28건 처리시간 0.026초

변위비례식 마찰댐퍼의 특성에 관한 연구 (A Study on the Characteristics of an Amplitude Proportional Friction Damper)

  • 박동훈;최명진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.717-720
    • /
    • 2002
  • An Amplitude Proportional Friction Damper (APFD) system is considered in order to improve the stick-slip characteristics of Coulomb friction damper. The frictional force is proportional to the amplitude in APFD system and the system is non-linear as is Coulomb damper system. The free vibration analysis on an 1-DOF system has conducted to demonstrate the characteristics of the APFD system and the results show that the APFD system has similar damping characteristics to the viscous damper system. It is concluded that the APFD system may become a cost effective substitution for the viscous damper and it also has certain advantages over Coulomb damper system since the APFD system can be designed to work with no stick-slip.

  • PDF

The effect of mainshock-aftershock on the residual displacement of buildings equipped with cylindrical frictional damper

  • Mirtaheri, Masoud;Amini, Mehrshad;Rad, Moosa Doosti
    • Earthquakes and Structures
    • /
    • 제12권5호
    • /
    • pp.515-527
    • /
    • 2017
  • Recently, Friction dampers become popular due to the desirable performance in the energy dissipation of lateral loads. A lot of research which has been conducted on these dampers results in developing friction dampers with low sensitivity to the number of cycles and temperature increases. Friction dampers impose high residual drifts to the buildings because of low post-yield stiffness of the damper which results from increasing lateral displacement and period of buildings. This issue can be more critical under strong aftershocks which results in increasing of structural damages. In this paper, in addition to the assessment of aftershock on steel buildings equipped with friction dampers, methods for controlling residual drifts and decreasing the costs of retrofitting are investigated. Utilizing rigid connections as a lateral dual system and activating lateral stiffness of gravity columns by adding elastic braces are as an example of effective methods investigated in this research. The results of nonlinear time history analyses on the low to medium rise steel frames equipped with friction dampers illustrate a rise in residual drifts as the result of aftershocks. In addition, the results show that different slip loads of friction damper can affect the residual drifts. Furthermore, elastic stories in comparison to rigid connections can reduce residual drifts of buildings in an effective fashion, when most slip loads of friction dampers are considered.

Pilot study for investigating behavior of recentering frame connection equipped with friction damper

  • Kim, Young Chan;Hu, Jong Wan
    • Steel and Composite Structures
    • /
    • 제44권4호
    • /
    • pp.569-586
    • /
    • 2022
  • This study introduces a novel friction damper as a component of a recentering frame connection, to solve the problem of structural repair costs, caused by stiffness deterioration and brittle fracture of the central brace frame (CBF). The proposed damper consists of shape memory alloy (SMA) bars with pretension applied to them to improve the stability. SMAs reduce the residual displacement by virtue of the properties of the materials themselves; in addition, a pretension can be applied to partially improve their energy dissipation capacity. The damper also consists of a friction device equipped with friction bolts for increased energy dissipation. Therefore, a study was conducted on the effects of the friction device as well as the pretension forces on the friction damper. For performance verification, 12 cases were studied and analyzed using ABAQUS program. In addition, the friction and pretension forces were used as variables in each case, and the results were compared. As a result, when the pretension and friction force are increased, the energy dissipation capacity gradually increases by up to about 94% and the recentering capacity decreases by up to about 55%. Therefore, it has been shown that SMA bars with adequate pretension in combination with bolts with adequate frictional force effectively reduce residual deformation and increase damper capacity. Thus, this study has successfully proposed a novel friction damper with excellent performance in terms of recentering and energy dissipation capacity.

승용차 동력전달계의 히스테리시스 영향에 관한 연구 (A Study on the Hysteresis Effects on a Passenger Car Driveline)

  • 김영흡;박동훈
    • 한국자동차공학회논문집
    • /
    • 제16권5호
    • /
    • pp.140-146
    • /
    • 2008
  • A friction damper is installed in the passenger car driveline in order to dissipate the torsional vibration energy. The frictional damping hysteresis has considerable influences on the driveline vibration characteristics and, therefore, it is one of the most important parameters in the damper design. To investigate the hysteresis effects on the driveline vibration, a dynamic model of the passenger car driveline with manual transmission has developed, and simulations were executed on the several different driving conditions for various hysteresis values. To verify the model, vehicle tests are preformed and the test data were compared with the simulations results. The simulation and test results show good agreements and the model could be used to determine the optimal hyteresis values in early design stage of the damper.

Seismic performance of a rocking bridge pier substructure with frictional hinge dampers

  • Cheng, Chin-Tung;Chen, Fu-Lin
    • Smart Structures and Systems
    • /
    • 제14권4호
    • /
    • pp.501-516
    • /
    • 2014
  • The rocking pier system (RPS) allows the columns to rock on beam or foundation surfaces during the attacks of a strong earthquake. Literatures have proved that seismic energy dissipated by the RPS through the column impact is limited. To enhance the energy dissipation capacity of a RPS bridge substructure, frictional hinge dampers (FHDs) were installed and evaluated by shaking table tests. The supplemental FHDs consist of two brass plates sandwiched by three steel plates. The strategy of self-centering design is to isolate the seismic energy by RPS at the columns and then dissipate the energy by FHDs at the bridge deck. Component tests of FHD were first conducted to verify the friction coefficient and dynamic characteristic of the FHDs. In total, 32 shaking table tests were conducted to investigate parameters such as wave forms of the earthquake (El Centro 1940 and Kobe 1995) and normal forces applied on the friction dampers. An analytical model was also proposed to compare with the tested damping of the bridge sub-structure with or without FHDs.

구조물 내진보강을 위한 다중 마찰댐퍼의 성능 평가 (Performance Evaluation of Multi-Friction Dampers for Seismic Retrofitting of Structures)

  • 김성배;권형오;이종석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권6호
    • /
    • pp.54-63
    • /
    • 2022
  • 이 연구는 구조물 내진보강 장치의 하나인 마찰댐퍼에 관한 것으로, 내부 마찰재를 복합재료의 일종인 초고분자량 폴리에틸렌으로 대체하여 댐퍼를 개발하였다. 또한 마찰력이 발생하는 내부 구조를 여러 층으로 적층하는 다중 마찰방식을 적용하였다. 개발된 다중 마찰댐퍼의 성능 검증을 위해서 재료에 대한 기초 물성과 마모 특성, 디스크 스프링에 대한 특성 분석 시험을 수행하였다. 마모시험 시험결과, UHMWPE의 질량 감소율은 0.003%로 복합재료 기반의 마찰재 중에서 가장 우수한 성능을 보였다. 디스크 스프링은 유한요소해석과 시험결과로부터 설계기초자료를 확보하였다. 또한 개발된 다중 마찰댐퍼의 품질 안정성을 확인하기 위해 토크값에 따른 마찰력 변화와 감쇠장치에 대한 지진하중 시험을 수행하였다. 품질성능 시험결과, 토크 값 조절에 따라 선형적인 마찰력 변화를 보였으며, 지진하중 시험 결과, 마찰댐퍼의 허용오차는 설계기준에서 요구하는 15% 미만으로 나타나 내진보강 장치로서의 요구조건을 만족하는 것으로 나타났다.

Study on Application of Reinforcement Device to Provide Greater Dynamic Stability for Power Transmission Towers and its Effect

  • Yang, Kyeong-hyeon;Bae, Choon-hee;Jeong, Nam-geun;Kim, Doo-young;Kim, Sung-min;Jang, Yong-hee
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권1호
    • /
    • pp.33-41
    • /
    • 2016
  • To verify that the friction damper used to high buildings as a kind of control technology of wind vibration can reduce dynamic behaviors of PTTs effectively, slip dampers in this paper are proposed to absorb the energy through relatively frictional movement of slip dampers applied to main post of a PTT (Power Transmission Tower) when dynamic displacement of a PTT occurs. The result of dynamic analysis is presented to determine the capacity of the damper system by controlling damping ratio on the resonance condition. It is observed that by installing slip dampers at a PTT the strain amplitudes of the main post caused by wind load are effectively reduced. Therefore it is shown that the proposed damper satisfies the strengthened wind-load design standards, and its efficacy was also validated experimentally by field testing.

수직력의 변화를 고려한 마찰댐퍼의 거동 분석 (Performance Analysis of Friction Damper Considering the Change of the Vertical Force)

  • 조성국;박웅기;이성태
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권1호
    • /
    • pp.59-66
    • /
    • 2017
  • 이 논문에서는 원자력발전소나 각종 플랜트 시설물에서 배관을 보호하기 위하여 마찰방식을 이용한 댐퍼를 개발하여 성능을 분석하는 연구를 수행하였다. 마찰방식댐퍼는 MER-Spring에 압축력을 가하여 베어링과 샤프트에 마찰력을 발생시켜 진동을 감쇠시키는 장치이다. 댐퍼의 성능을 분석하기 위하여 MER-Spring과 마찰재의 재료특성을 분석하고, 마찰의 영향에 대한 연구를 수행하였으며, 이에 대한 거동 방정식을 수립하였다. 또한 재료의 변형 여부를 판단 및 수립된 거동방정식의 신뢰성 검토를 위하여 시작품을 제작하였고 시편으로 제작된 댐퍼의 성능 시험과 유한요소 해석을 통하여 이를 분석하였다. 그 결과, 재료의 신뢰성이 확인되었고 마찰계수는 속도에 따른 보정이 필요하며, 반복재하 실험 및 유한요소해석 결과 우수한 결과를 나타냄을 확인하였다. 또한, 추후에 동적하중에 대한 검토가 수행되어 이 연구의 성과가 더 넓은 범위에 적용되었으면 한다.

Seismic progressive collapse mitigation of buildings using cylindrical friction damper

  • Mirtaheri, Masoud;Omidi, Zobeydeh;Salkhordeh, Mojtaba;Mirzaeefard, Hamid
    • Earthquakes and Structures
    • /
    • 제20권1호
    • /
    • pp.1-12
    • /
    • 2021
  • The occurrence of progressive collapse induced by the removal of the vertical load-bearing element in the structure, because of fire or earthquake, has been a significant challenge between structural engineers. Progressive collapse is defined as the complete failure or failure of a part of the structure, initiating with a local rupture in a part of the building and can threaten the stability of the structure. In the current study, the behavior of the structures equipped with a cylindrical friction damper, when the vertical load-bearing elements are eliminated, is considered in two cases: 1-The load-bearing element is removed under the gravity load, and 2-The load-bearing element is removed due to the earthquake lateral forces. In order to obtain a generalized result in the seismic case, 22 pair motions presented in FEMA p 695 are applied to the structures. The study has been conducted using the vertical push down analysis for the case (1), and the nonlinear time-history analysis for the second case using OpenSEES software for 5,10, and 15-story steel frames. Results indicate that, in the first case, the load coefficient, and accordingly the strength of the structure equipped with cylindrical friction dampers are increased considerably. Furthermore, the results from the second case demonstrate that the displacements, and consequently the forces imposed to the structure in the buildings equipped with the cylindrical friction damper substantially was reduced. An optimum slip load is defined in the friction dampers, which permits the damper to start its frictional damping from this threshold load. Therefore, the optimum slip load of the damper is calculated and discussed for both cases.