• 제목/요약/키워드: friction resistance coefficient

검색결과 324건 처리시간 0.02초

CHANGES OF ABUTMENT SCREW AFTER REPEATED CLOSING AND OPENING

  • Kim Hee-Jung;Chung Chae-Heon;Oh Sang-Ho;Choi Han-Cheol
    • 대한치과보철학회지
    • /
    • 제42권6호
    • /
    • pp.628-640
    • /
    • 2004
  • Statement of problem. Wear as a result of repeated closing/opening cycles may decrease the friction coefficient of screw head, threads, and other mating components and, consequently, resistance to opening gradually decreases. It may cause screw loosening, which is one of the most common failures in implant prosthesis. Purpose. The purpose of this study is to evaluate the changes on the head and thread surface of the abutment screws after repeated closing and opening through the examination of tested screws in SEM(scanning electron microscope). Materials and methods. Five species of abutments were selected (3i-three, Avana-two) respectively by two pieces. The implant fixtures were perpendicularly mounted in liquid unsaturated polyesther(Epovia, Cray Valley Inc.) with dental surveyor. Each abutment was secured to the implant fixture by each abutment screw with recommended torque value using a digital torque controller. The abutment screws were repeatedly tightened and removed 20 times with a digital controller. FESEM (field emission scanning electron microscope, Netherland, Phillips co., model:XL 30 SFEG) was used to observe changes of each part caused by repeatedly closing/opening expeiment. First, the Photomicrographs of pre-test screws provided by each manufacturer were taken. The changes of each screw were investigated after every fifth closing and opening experiment with FESEM. Scaning electron microscope photomicrographs of each screw were taken four times. Results. As the number of closing and opening was increased, the wear or distortion of hexed or squared slot that contacted with the driver tip was more severely progressed. Wear or distortion of hexed slot was more severe than that of squared slot and it was more remarkable in the titanium screw than in the gold screw. All the tested screws showed that the width in the crest of their screw thread decreased gradually as the test was proceeded. Conclusions. Conclusively, we recommend the clinical use of gold screw, a periodic exchanges of abutment screws and avoiding repeated closing/opening unnecessarily. We also suggest a more careful manipulation of the abutment screw and screw-driver and using of abutment screw with an acute-angled slot design rather than an obtuse-angled one. Finally, it is suggested that the new slot design and the surface treatment for enduring wear or distortion should be devised.

임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이 전하중에 미치는 영향에 관한 연구 (INFLUENCE OF TUNGSTEN CARBIDE/CARBON COATING ON THE PRELOAD OF IMPLANT ABUTMENT SCREWS)

  • 최진욱;정창모;전영찬;임장섭;정희찬;엄태관
    • 대한치과보철학회지
    • /
    • 제44권2호
    • /
    • pp.229-242
    • /
    • 2006
  • Statement of problem: In order to increase preload with reducing the friction coefficient, abutment screws coated with pure gold and Teflon as dry lubricant coatings have been introduced. But the reported data indicate that if screw repeated tightening and loosening cycle, an efficiency of increasing preload was decreased by screw surface wearing off. Purpose: This study was to evaluate the influence of tungsten carbide/carbon coating, which has superior hardness and frictional wear resistance, on the preload of abutment screws and the stability of coating surface after repeated closures. Material and method: The rotational values of abutment screws and the compressive forces between abutment and fixture were measured in implant systems with three different joint connections, one external butt joint and two internal cones. Moreover the stability and the alteration of coating surface were examined by comparison of the compressive force and the removable torque values during 10 consecutive trials, observation with scanning electron microscope and analyzed the elemental composition with energy dispersive x-ray spectroscopy Results and conclusion: 1. Application of coating resulted in significant increase of compressive force in all implant systems(P<.05). The increasing rate of compressive force by coating in external butt joint was gloater than those in internal cones (P<.05). 2. Coated screw showed the significant additional rotation compared to non-coated screw in all implant systems (P<.05). There were no significant differences in the increasing rate of rotation among implant systems (P>.05). 3. Removable torque values were greater with non-coated screw than that with coated screw (P<.05). 4. Coated screw showed insignificant variations in the compressive forces during 10 consecutive trials(P>.05) 5. After repeated trials, the surface layer of coated screw was maintained relatively well. However surface wearing and irregular titanium fragments were found in non-coated screw.

주파수 변동에 따른 초음파방오장비의 파울링제거효과 (Antifouling Effect of an Ultrasonic System Operating at Different Frequencies)

  • 배진우;박관식;류명록;박권하
    • 해양환경안전학회지
    • /
    • 제25권5호
    • /
    • pp.609-616
    • /
    • 2019
  • 선박에 파울링이 발생되면 운항 중 선박의 저항이 증가하게 되고 이로 인해 연료 소모량도 높아지게 된다. 또한 파울링의 제거에 많은 시간이 필요하게 되어 전체적으로 선박의 유지보수 비용이 증대되는 문제점이 있다. 이러한 문제점을 해결하고 환경오염을 방지하기 위해 주석과 같은 독성 물질을 포함하지 않는 자기연마형 방오도료를 개발하고 있다. 이와 같은 종래기술은 해수와의 마찰이나 진동이 많이 발생하는 운항 중에는 연마기능이 촉진되어 방오성능이 증대되나, 정박 중과 같이 실제로 파울링이 심화되는 경우에는 해수의 흐름이 없어 연마기능이 저하되어 방오성능이 떨어지는 문제점이 있다. 이러한 문제점을 해결하기 위해 선체의 진동 및 해수의 흐름이 없어서 연마 기능이 저하되는 정박 중에도 진동을 부여하여 연마 기능의 저하를 방지하는 제품을 개발하였다. 개발된 초음파 방오장비의 성능의 신뢰성을 위해 파형발생기의 반복성을 확인하였고 장치의 파울링 제거효율의 정성적인 경향은 시편을 통해 파악하였다. 실험 결과 주파수와 진폭의 반복성의 변동계수 값은 평균 0.2 %, 4.0 %를 나타냈고 시편의 파울링 발생량은 No.5 시편에서 73.3 g으로 가장 많았고 파울링 제거효율은 장치를 설치하지 않은 시편과 비교하여 평균 93.2 % 값을 확인할 수 있었다.

화강암질풍화토(花崗岩質風化土)의 역학적(力學的) 성질(性質)에 관(關)한 연구(硏究) -전단강도(剪斷强度)의 영향요소(影響要素)와 견밀도(堅密度)에 대(對)하여- (Studies on the Mechanical Properties of Weathered Granitic Soil -On the Elements of Shear Strength and Hardness-)

  • 조희두
    • 한국산림과학회지
    • /
    • 제66권1호
    • /
    • pp.16-36
    • /
    • 1984
  • 화강암질풍화토(花崗岩質風化土)의 미교란(未攪亂) 시료(試料)를 사용하여 일면(一面) 직접(直接) 전단시험(剪斷試驗)으로 측정(測定)한 전단강도(剪斷强度)와 함수비(含水比), 간극비(間隙比), 건조밀도(乾燥密度), 비중(比重)과의 관계(關係)를 통계(統計) 분석(分析)하였고, 화강암질풍화토(花崗岩質風化土)의 사방시공지(砂防施工地)에 식재(植栽)된 리기다소나무림(林)과 리기테-다소나무림(林)에서 토양단면(土壤斷面)을 만들어 산중식토양경도계(山中式土壤硬度計)로 토양(土壤)의 견밀도(堅密度)를 측정(測定)하고 수근분포(樹根分布)를 조사(調査)하여 통계(統計) 분석(分析)한 결과(結果) 다음과 같다. 1) 함수비(含水比), 간극비(間隙比)와 전단강도(剪斷强度) 간(間)에는 유의적(有意的)인 부(負)의 상관(相關)이며 직접적(直接的)인 관계(關係)에 있었다. 2) 건조밀도(乾燥密度)와 전단강도(剪斷强度) 사이에는 정(正)의 상관(相關)이며 직접적(直接的)인 관계(關係)에 있었다. 3) 비중(比重)과 전단강도(剪斷强度) 간(間)에는 유의적(有意的)인 상관관계(相關關係)를 인정(認定)할 수 없었다. 4) 전단강도(剪斷强度)에 영향(影響)을 미치는 영향요소(影響要素)의 직접효과(直接效果)의 크기는 함수비(含水比)>간극비(間隙比)>건조밀도(乾燥密度)의 순위(順位)이다. 5) 다중선형(多重線型) 회귀방정식(回歸方程式)의 분산분석결과(分散分析結果) 함수비(含水比)만이 회귀성(回歸性)이 인정(認定)되므로 함수비(含水比)를 독립변수(獨立變數)로 하여 전단강도(剪斷强度)를 추정(推定)하기 위한 회귀방정식(回歸方程式)은 제한(制限)된 건조밀도(乾燥密度)의 범위내(範圍內)에서 적합도(適合度)가 매우 높게 평가(評價)되었다. 6) 토양(土壤)의 견밀도(堅密度)는 토심(土深)이 깊어짐에 따라 높아진다. 7) 토양(土壤)의 지표경도(指標硬度)와 수근수(樹根數) 간(間)에는 유의적(有意的)인 부(負)의 상관(相關)이며 직접적(直接的)인 관계(關係)에 있었다. 8) 리기다소나무와 리기테-다소나무의 수근(樹根)은 토심(土深) 20cm까지에 대부분 분포(分布)하고 있었다. 9) 리기다소나무림(林)과 리기테-다소나무림(林)에서 측정(測定)한 토양(土壤)의 지표경도(指標硬度)를 독립변수(獨立變數)로한 회귀방정식(回歸方程式)으로 수근수(樹根數)를 추정(推定)할 수 있었으나 낮은 적합도(適合度)를 나타내었다.

  • PDF