• Title/Summary/Keyword: frequency standard

Search Result 3,338, Processing Time 0.033 seconds

Field Strength Standards in 30~ 1000MHz Frequency Range (30~1000MHz 주파수 범위에서의 전자기장의 세기 표준)

  • 김정환;강찬구
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.12
    • /
    • pp.1893-1901
    • /
    • 1993
  • This paper presents the field strength standard established using a standard antenna method in the frequency range of 30~1000MHz at KRISS(Korea Research Institute of Standards and Science). Designs on antenna elements and a balun, and the characteristics of an antenna voltmeter are described. The uncertainties in generation the standard fields are analzed and estimated to be 5~14%.

  • PDF

The Frequency Protection of Distribution System with Photovoltaic System (태양광 연계 계통의 주파수 보호 기준 정립)

  • Seo, Hun-Chul;Kim, Chul-Hwan;Yoon, Young-Min
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.440_441
    • /
    • 2009
  • The standard for the frequency protection of distributed generation in Korea Electric Power Corporation (KEPCO)'s standard doesn't include the setting of frequency protection. Therefore, this paper analyzes the correlation between the frequency protection requirements and the stability of grid-connected PV system for the adjustable operating setting of frequency protection. The distribution system interconnected with 3 MW PV system is modeled by Matlab/Simulink. The various value of frequency is simulated. For studied cases, the stability of PV system is analyzed. It is concluded that the operating setting of frequency protection can be determined by the stability of PV system.

  • PDF

Noise Evaluation Considering the Uncertainty Variation According to Frequency

  • Lee, Chulwon;Koo, SeungJun;Kong, Young Mo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.04a
    • /
    • pp.191-196
    • /
    • 2014
  • In the evaluation of measured noise data, tolerance shall be decided based on the uncertainty. The uncertainty has frequency variations due to the different standard deviations at each frequency. Therefore, tolerance shall be differently decided for each frequency with the same confidence probability. In the report, the evaluation method considering the frequency variation of uncertainty will be introduced. From the approach, considering the actual noise distribution characteristics of the ships, the tolerance shall be decided for each frequency with the same probability, but the overall averaged value shall be kept to the value designated in each notation.

  • PDF

Cesium Frequency Standard Based on a Continuous Slow Atomic Beam (연속 저속 원자빔을 이용한 세슘 주파수 표준기)

  • Lee, Ho-Sung;Park, Sang-Eon;Kwon, Taek-Yong;Yang, Sung-Hoon;Cho, Hyuk
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.194-195
    • /
    • 2000
  • Laser-cooled slow atoms can lead to a considerable improvement in both the accuracy and the frequency stability of atomic frequency standards. Most of the developed frequency standards with the slow atoms use atomic fountain scheme that includes pulsed atomic beam. Although this type of frequency standard has already demonstrated the accuracy about 10$^{-15}$ level$^{(1)}$ , a continuous beam of slow atoms may become an alternative approach, because the pulsed operation of the atomic fountain has some drawbacks such as the collisional shift and the limitation in the short-term frequency stability. (omitted)

  • PDF

The Systematic Management for Trace Hazard Compounds in Drinking Water (수돗물에서 미량유해물질의 체계적 관리방안 연구)

  • Park, Sun-Ku;Rim, Yeon-Taek
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.5
    • /
    • pp.431-441
    • /
    • 2005
  • The study was carried out to improve and regulate the drinking water quality standard and drinking water quality monitoring substances. For the reliability and safety of finished water, It has been monitored for trace organic and inorganic compounds of 333 in finished water of water treatment plants during 1989 to 2003. As a result of monitoring, 51 compounds were detected from 333 compounds, and it has been regulated the drinking water quality standard of 26 substances and 20 mitoring substance. Improvement and regulation method of the drinking water quality standard was performed by comparing and analyzing with detection concentration, detection frequency, risk assessment and foreign drinking water quality standard.

Design of a wavelet adaptive filter for removal of the baseline wandering (기저선 변동 제거를 위한Wwavelet Adaptive Filter의 설계)

  • 박광리;이경중;윤형로
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.10
    • /
    • pp.80-88
    • /
    • 1997
  • This paper describes a design of a Wavelet Adaptive Filter(WAF) for the removal of the baseline wandering and the minimization of the signal distortion using by wavelet transform and adaptive filter in the ECG signal. WAF consists of two parts. The first part is wavelet transform that decomposes the ECG signal into seven frequency bands using Vaidyanathan and Hoang wavelet. The second part is adaptive filter that uses the signal of seventh low frequency band among the wavelet transformed signals as primary input and a unit impulse sequence as reference input. For the evaluation of the performance of WAF, we used several baseline wandering elimination filters such as commerical standard filter with cutoff frequency of 0.5Hz and general adaptive filter. We made use of MIT/BIH database and real patient data for the evaluation. In conclusion, WAF showed a lower ST segement distortion than standard filter and adaptive filter and has a higher eliminated noise power than standard filter and adaptive filter.

  • PDF

Vibration Fatigue Analysis of Automotive Fuel Tank Using Transfer Function Method (Transfer Function Method를 이용한 자동차 연료탱크의 진동 피로 해석에 대한 연구)

  • Ahn, Sang Ho
    • Journal of Auto-vehicle Safety Association
    • /
    • v.12 no.3
    • /
    • pp.27-33
    • /
    • 2020
  • In this paper, the process of predicting efficient durability performance for vibration durability test of automobile parts using vibration test load on automobile fuel tank is presented. First of all, the common standard load that can be applied to the initial development process of the automobile was used for the fuel tank and the vulnerability of the fuel tank to the vibration fatigue load was identified through frequency response analysis. In addition, the vulnerability of the fuel tank was re-enacted through vibration durability test results, and the scale factor was applied to the standard load. In order to predict the vibration durability performance required for detailed design, vibration fatigue analysis was performed on the developed vehicle with the frequency of vibration severity equivalent to the durability test, and the vulnerability and life span of the fuel tank were identified through the process of applying weights to these selected standard loads, thereby reducing the test time of the development vehicle.

Suggestion of standard color code for displaying ground acceleration (지진가속도 간의 칼라코드 표준화)

  • 지헌철;전정수;신진수;이희일;박정호
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.09a
    • /
    • pp.61-71
    • /
    • 2002
  • Color-code imaging should be one of the best display tools for the quick perception of both damage area and its intensity, In this study we proposed the standard color code corresponding to maximum observed acceleration value. Since the acceleration value changes with frequency contents, we suggested to limit the frequency band less than 10Hz. The background considerations of this limitation, magnitude vs. dominant frequency, natural characteristics of artificial noises and the relationship between velocity and acceleration, were reviewed in detail. The standard of color code was assigned from 0.001%g to 20%g based on the possible earthquakes at Korean peninsula and the color imaging given by RGB value was shown to be very consistent, irrespective of hardware configuration.

  • PDF

An Experimental Study on the Performance of Inverter Heat Pump with a Variation of Frequency and Capillary Size

  • Choi, Jong-Min;Kim, Yong-Chan;Kim, Jong-Yup
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.27-35
    • /
    • 1998
  • An experimental study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4,141 W(3,550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of l,000mm(optimum size for the frequency of 60Hz) and ASHRAE Test condition "A" was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycles were investigated by varying the length of capillary tube at each frequency level of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency level. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher energy efficiency ratio(EER), while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF

An experimental study on the performance of inverter heat pump with a variation of frequency and capillary size (인버터 열펌프의 주파수 및 모세관 길이 변화에 따른 시스템 성능특성의 실험적 연구)

  • Choi, J.M.;Kim, Y.C.;Kim, J.Y.;Bae, Y.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.64-72
    • /
    • 1997
  • An experiment study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4141W(3550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of 1000mm which was optimum size for the frequency of 60Hz and ARHRAE Test condition A was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycle was invesigated by varying the length of capillary tube at each frequency levels of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency levels. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher EER, while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF