• Title/Summary/Keyword: frequency standard

Search Result 3,338, Processing Time 0.03 seconds

FREQUENCY STANDARD AND CLOCK SYSTEM IN VLBI (VLBI의 기준 주파수와 시각 동기 시스템)

  • OH SE-JIN;CHUNG HYUN-SOO;ROH DUK-GYOO;KIM KWANG-DONG
    • Publications of The Korean Astronomical Society
    • /
    • v.19 no.1
    • /
    • pp.93-99
    • /
    • 2004
  • In this paper, we describe a principle of the atomic frequency standard and clock system in VLBI(Very Long Baseline Interferometry). The hydrogen maser is a usual VLBI standard. During VLBI observations, signals emitted by distant sources of radio frequency energy(quasars) are received and recorded at several antennas. At each antenna(VLBI station), a very stable frequency standard(hydrogen maser) provides a reference signal which enables time-tagging to the quasar signals as they are being recorded on magnetic tapes or hard-disk modules. For each VLBl experiment, correlation of the time-tagged recorded information between the participating antennas is used to yield the arrival time differences of any specific quasar radio wave between the antennas. These time differences are used to calculate the relative antennas to each other. In this paper, we also introduce the KVN(Korean VLBI Network) atomic frequency standard and clock system.

A Study on Effectiveness of Application of the IEC 61689 Standard to Ultrasonic Physiotherapy Systems with Frequency Range over 5MHz (5MHz 초과 초음파자극기에 대한 IEC 61689 규격 적용의 유효성에 관한 연구)

  • Youn, Ju-Shin;Choi, Gi Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.3
    • /
    • pp.69-78
    • /
    • 2015
  • Ultrasonic physiotherapy systems should comply with IEC 60601-2-5(particular requirements for safety of ultrasonic physiotherapy equipment) standard for safety of patients and clinical performances. One of the most important parameters in the standard is the effective radiating area ($A_{ER}$). It has to be measured in accordance with IEC 61689 (field specifications and methods of measurement in the frequency range 0.5MHz to 5MHz). Typical ultrasonic physiotherapy system works in the frequency range 1MHz ~ 3MHz to comply with the IEC 61689. However, ultrasonic physiotherapy system using frequencies over 5MHz is out of the IEC 61689's scope. That is, even if such ultrasonic physiotherapy systems are developed by demands of the market, there is no standard to apply. It is the motivation for this study. Whereas there are other parameters to be considered, this study focuses on the effective radiating area and shows effectiveness of applying IEC 61689 in measuring effective radiating area of ultrasonic physiotherapy systems using frequency range over 5MHz by comparing the results of computer simulation and experiment. Results of this study shows that applying the IEC 61689 standard to ultrasonic physiotherapy system using frequency range over 5MHz is possible.

Effects of the Phase Noise in the Frequency Synthesizer on the SFH/M-NCFSK System (주파수 합성기의 위상 잡음이 SFH/M-NCFSK 시스템에 미치는 영향)

  • 손종원;이준서;유흥균;박진수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.7
    • /
    • pp.685-691
    • /
    • 2003
  • This paper newly analyzes the effect of the phase noise in the frequency synthesizer on the performance of SFH/M-NCFSK system by standard frequency deviation(equation omitted) when noncoherent FSK demodulation of the square-law detector is considered. We derive the SER in the SFH system and analyze the effect of phase noise on the SFH/M-NCFSK system performance according to the hopping frequency spacing (1/T$\_$h/) and the variation of the standard frequency deviation (equation omitted). The required SNR is about 13.4 dB to meet Ps=10$\^$-3/ when the standard frequency deviation is about 4.0 Hz and the hopping frequency spacing (1/T$\_$h/) in the SFH/2-NCFSK system is 30. So, there is about 2.4 dB power penalty than the phase noise-free system. If the hopping frequency spacing 1/T$\_$h/ is under 30, the error floor may happen and SER considerably grows up. We show that the analytic results closely match with the simulation results.

Obstructive Sleep Apnea Analysis Based on Heart Rate Variability (폐쇄성 수면 무호흡 검출을 위한 심박동변이율 분석)

  • Ye, Soo-Young;Kim, Jung-Guk;Kim, Dong-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.7
    • /
    • pp.605-608
    • /
    • 2011
  • In this study, OSA (the obstructive sleep apnea) periods were detected in patients with OSA during sleep because of the treatment was different according to the frequency and symptoms of obstructive sleep apnea. ANS (autonomic nervous activity) was changed by obstructive sleep apnea periods so we intended to detect the periods to care the obstructive sleep apnea patients. RR intervals, SDNN (standard deviation of normal to normal) and RMSSD (root mean square standard deviation) were calculated in time domain analysis and LF (low frequency), HF (high frequency), NHF (normalized high frequency), NLF (normalized low frequency) were calculated in frequency domain analysis of HRV (heart rate variability) with obstructive sleep apnea patients. In this paper, SDNN (standard deviation of normal to normal) of time domain analysis were decreased in the obstructive sleep apnea periods. And NLF and LF/HF ratio were increased and NHF (normalized high frequency) was decreased in the frequency domain analysis. The parameters can be used to treat obstructive sleep apnea patients by detecting the obstructive sleep apnea periods such as CPAP (continuous positive airway pressure).

Frequency Stabilization of Femtosecond Lasers for Dimensional Metrology (거리 및 형상 측정을 위한 펨토초 레이저의 주파수 안정화)

  • Kim Young-Jin;Jin Jong-Han;Kim Seung-Woo
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.188-191
    • /
    • 2005
  • A common feature in various methods of optical interferometry for absolute distance measurements is the use of multiple monochromatic light components either in sequence or in parallel at the same time. Two or multiple wavelength synthesis has been studied though its performance is vulnerable to the frequency instability of the light source. Recently continuous frequency modulation is considered a promising method with availability of wide band tunable diode lasers, which also have frequency instability errors. We can lock frequencies of these third-party light sources to the modes of the femtosecond laser which is stabilized to the precision of the standard radio frequency. To this end, we have stabilized all the modes of the femtosecond laser to the atomic frequency standard by using powerful tools of frequency-domain laser stabilization.

  • PDF

The Study on Standard Bodytype for Korean Women between the ages of 18 and 24 years old(Part II) -Standard proportion and Standard bodytype- (18~24세 한국인 여성의 표준체형에 관한 연구(제2보) -표준프로포션과 표준체형에 대하여-)

  • 이정임;남윤자
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.6
    • /
    • pp.801-810
    • /
    • 2002
  • The purpose of this study is to suggest standard bodytype which offers criterion for the sizes and shapes to interpret various bodytypes, to estimate fitting, and to construct ready-made clothing. There were two ways of analyzing bodytypes of subjects from the viewpoint of statistic and beauty. We had carried on the analysis from the viewpoint of statistic in the Part(1) and we carried on the analysis from the viewpoint of beauty in this Part(2). Taken as a sample, the subjects were ninety-seven females who were between the aloes of 18 and 24 rears o1d. They were measured on November 1999. The data of seven hundred and four females,18∼24 year-old, from the National Somatometry Survey of 1997 were used for analysis, too. The first analysis from the viewpoint of beauty was executed to the front and side photographs of the subjects to analyze the general traits of the beautiful bodytype. The second analysis from the viewpoint of beauty was executed to subjects who were in both High-frequency proportion range and Beautiful bodytype group. As the result, four groups in Beautiful and High-frequency proportion range were selected. The standard proportion was analyzed with the size and shape of four groups. Based on the standard proportion, the size, shape and silhouette of the standard bodytype were analyzed. To verify the size, shape and silhouette of the standard bodytype, the location of the standard bodytype in the 1997 National Somatometry Survey group was analyzed. As the result, the standard bodytype was verified as proper criterion to interpret various bodytypes, to estimate fitting, and to construct ready-made clothing.

Analysis of IEC 61727 Photovoltaic (PV) systems Characteristics of the utility interface

  • Lee, Jeong Hyeon;Yoon, Yong Ho;Kim, Jae Moon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.2
    • /
    • pp.90-95
    • /
    • 2015
  • This paper describes IEC 61727 standard of Photovoltaic (PV) systems -Characteristics of the utility interface. IEC 61727 standard tests include utility compatibility and personnel safety and equipment protection of PV inverter performance functions. Especially utility compatibility part includes test items of 1) voltage, current and frequency, 2) normal voltage operating range, 3) flicker, 4) DC injection, 5) normal frequency operating range, 6) harmonics and 7) waveform distortion, 8) power factor of PV inverter. Also personnel safety and equipment protection part includes test items 1)loss of utility voltage, 2)over/under voltage and frequency, 3)Islanding protection, 4)response to utility recovery, 5)earthing, 6)short circuit protection, 7)Isolation and switching of PV inverter. In this paper, each item of IEC 61727 standard test is studied and analyzed and finally full tested by PV inverter performance function.

The Effect of the Physical Therapy Treatment Room Environment Using Microwave Diathermy on the Autonomic Nervous System of Human Body (극초단파치료기를 사용하는 물리치료실의 환경이 물리치료사의 인체자율신경계에 미치는 영향)

  • Shin, Han-Ki;Lee, Tae-Kyu;Jun, Je-Yoon;Kim, Ju-Seung;Kang, Jong-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.1
    • /
    • pp.37-43
    • /
    • 2015
  • PURPOSE: The purpose of this study is to investigate the effect of the physical therapy treatment room environment using microwave diathermy on the autonomic nervous system of human body. METHODS: Participants were 24 healthy adults. Standard deviation of all normal R-R intervals(SDNN), root mean square of successive differences(RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were compared in microwave irradiation and non-irradiation group. Data were analyzed in Wilcoxon's signed-ranks test and Mann-Whitney U test. RESULTS: Standard deviation of all normal R-R intervals (SDNN), root mean square of successive differences (RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were not significantly different in microwave irradiation group. Standard deviation of all normal R-R intervals(SDNN), root mean square of successive differences (RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were not significantly different in microwave non-irradiation group. Standard deviation of all normal R-R intervals(SDNN), root mean square of successive differences (RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were not significantly different between two groups. CONCLUSION: There was no significant change in the sympathetic nervous system and parasympathetic nervous system regardless of the presence of microwave irradiation. There was no significant change in the autonomic nervous system adaptability regardless of the presence of microwave irradiation.According to this study, microwave diathermy does not have significant effect on the autonomic nervous system.Future study is necessary to investigate the long term effect of the physical therapy treatment room environment using microwave diathermy on the autonomic nervous system of the human body.

Measurement of Liquid Density using Tuning Fork (튜닝포크를 이용한 액체밀도의 계측)

  • Kim, Choong-Hyun;Lee, Yong-Bok;Lee, Sung-Chul
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.1
    • /
    • pp.86-91
    • /
    • 2007
  • A sensor using quartz toning fork is presented for measuring liquid density. It consists of a PZT plate as an actuator for piezoelectric excitation and a quartz tuning fork as a sensor for resonant frequency detection. The resonant frequency is determined from the sensing voltage measured in tuning fork when the excitation frequencies of PZT actuator are swept around the resonant frequencies of tuning fork. The resonant frequency determined the liquid density. The density values of three kinds of organic solvents are measured and compared with the standard values. The experimental results are in agreement with the standard values and the maximum standard deviation is less than 9%.

Noise and Vibration Characteristics of Construction structures in Standard Laboratory (표준실험동의 구조별 소음 진동 특성)

  • Jeong, Young;Yoo, Seung-Yub;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.390-393
    • /
    • 2005
  • In this study, examined heavy-weight floor impact sound to rahmen structure(steel reinforced concrete structure) and bearing-wall structure(box frame type structure) that have slab thickness of 4 form at a standard laboratory through noise and vibration measured. The results of ANSYS modeling of structures was predicted that the nature natural frequency increased according to change of thickness of each slab by finite element analysis, and acceleration value decreased. Rahmen structures compares with bearing-wall structure, nature frequency was predicted low. Measurement results of natural frequency and acceleration level for structures at a standard laboratory, tendency department such as ANSYS modeling appeared. Rahmen structures appeared that reduction effect is less in Acceleration level and heavy impact sound transmission level comparing with bearing-wall structure.

  • PDF