• 제목/요약/키워드: frequency responses

검색결과 2,010건 처리시간 0.026초

직사각형 평판의 비선형 진동 (Non-linear Vibration of Rectangular Plates)

  • Chang, Seo-Il;Lee, Jang-Moo
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1994년도 추계학술대회논문집; 한국종합전시장, 18 Nov. 1994
    • /
    • pp.35-39
    • /
    • 1994
  • One of the important characteristics of the response of nonlinear systems is the existence of subharmonic resonances. When some conditions in parameter space are satisfied. It is possible even in the presence of damping for a periodically excited nonlinear system to possess a response which is the combination of a contribution at the excitation frequency and a component at the system natural frequency. The system natural frequency being a submultiple of the excitation frequency implies that the resulting response is a subharmonic oscillation. In general, there also co-exists, for the system, a response at the excitation frequency, and initial conditions determine which of the steady-state responses is achieved in an experiment or a numerical simulation. In single-degree-of-freedom systems with harmonic excitation, depending on the type of the nonlinearity, e.g., cubic or quadratic the frequency of subharmonic response is respectively, one-third or one-half of that of the excitation frequency. Although subharmonic resonance is one of the principal characteristics of a nonlinear system the subharmonic responses of structures in the presence of internal resonances have been studied very rarely. In this work, we consider subharmonic responses in the two-mode approximation of the plate equations. It is assumed that the two modes are in one-to-one internal resonance. Constant and periodic steady-state solutions of the averaged equations are studied. Finally, the results of direct time integration of the original equations of motion are presented and compared with those obtained from the averaged equations.

  • PDF

국내 지진센서의 저주파 응답의 신뢰성에 관한 고찰 (Review on the reliability of low frequency responses of locally operating sensors)

  • 박동희;연관희;장천중
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.35-42
    • /
    • 2002
  • Frequency responses for most of the local seismic sensors in Korea have been roughly checked by mutual comparison of Fourier spectra of seismic records from accelerometer and seismometer, both of which are installed at the same location. Especially, because the frequency content of the seismic energy is usually above 1 Hz for local earthquakes, the reliability of low frequency response could have not been evaluated. Fortunately a recent large earthquake, Ms=7.2 on 02/06/29 containing dominant low frequency energy makes it possible to check the low frequency response of the seismic sensors, especially EpiSensor and JC-V100. Considering two types of sensor pairs, (STS-2 and EpiSensor, JC-V100 and EpiSensor), the low frequency response of EpiSensor is confirmed first by comparison with STS-2 which has proved low frequency response. Second, reliable low frequency limit of instrumentally corrected seismic data from JC-V100 data is estimated to be about 0.03 Hz by comparison with EpiSensor data.

  • PDF

Adaptive compensation method for real-time hybrid simulation of train-bridge coupling system

  • Zhou, Hui M.;Zhang, Bo;Shao, Xiao Y.;Tian, Ying P.;Guo, Wei;Gu, Quan;Wang, Tao
    • Structural Engineering and Mechanics
    • /
    • 제83권1호
    • /
    • pp.93-108
    • /
    • 2022
  • Real-time hybrid simulation (RTHS) was applied to investigate the train-bridge interaction of a high-speed railway system, where the railway bridge was selected as the numerical substructure, and the train was physically tested. The interaction between the two substructures was reproduced by a servo-hydraulic shaking table. To accurately reproduce the high-frequency interaction responses ranging from 10-25Hz using the hydraulic shaking table with an inherent delay of 6-50ms, an adaptive time series (ATS) compensation algorithm combined with the linear quadratic Gaussian (LQG) was proposed and implemented in the RTHS. Testing cases considering different train speeds, track irregularities, bridge girder cross-sections, and track settlements featuring a wide range of frequency contents were conducted. The performance of the proposed ATS+LQG delay compensation method was compared to the ATS method and RTHS without any compensation in terms of residual time delays and root mean square errors between commands and responses. The effectiveness of the ATS+LQG method to compensate time delay in RTHS with high-frequency responses was demonstrated and the proposed ATS+LQG method outperformed the ATS method in yielding more accurate responses with less residual time delays.

주파수 응답을 이용한 CF/Epoxy 복합적층판의 낙추충격 특성평가 (Characteristic Analysis of Falling Weight Impact Response in CF/Epoxy Composite Plates Using Frequency Responses)

  • 임광희;박노식;김영남;김선규;양인영
    • Composites Research
    • /
    • 제16권2호
    • /
    • pp.9-17
    • /
    • 2003
  • 낙추충격 시험시스템을 제작하여 CFRP적층판의 충격흡수특성 및 충격강도가 평가가 가능하였다. 충격에너지 대략 7J이상에서는 동일한 T300 섬유와 적층배향으로 구성된 직교이방성 시험편이 의사등방성(quasi-isotropic)보다 높게 나타났으나 T700 섬유의 경우에는 크게 차이가 나타나지 않았다. 또한 동일한 T300섬유와 적층수로 구성된 시험편이 T700 섬유로 된 시험편보다 높게 나타났으나 T700섬유인 의사등방성 시험편의 경우에는 크게 차이가 나타나지 않았다 초음파 C-스캐너를 이용하여 내부손상영역을 관찰하여 시험편의 손상면적과 흡수에너지의 상관관계를 고찰하였으며, 충격손상유무에 따라 박리면적과 주파수응답계수를 평가하였다 주파수응답계수와 박리면적사이에는 상관관계가 있음을 알 수 있었으며 충격손상으로 인한. 손상의 유무 및 정도를 주파수응답계수로 평가가 가능하였다.

시간영역에서 ISSC TLP의 비선형 응답 특성 (Nonlinear Response Characteristics of the ISSC TLP in Time Domain)

  • 이창호
    • 한국해양공학회지
    • /
    • 제20권5호
    • /
    • pp.30-35
    • /
    • 2006
  • In tire presence of incident waves with different frequencies, there are second order sum and difference frequency wave exciting forces due to the nonlinearity of tire incident waves. Although the magnitude of these nonlinear wave forces are small, they act on TLPs at sum and difference frequencies away from those of the incident waves. So, the second order sum and difference frequency waveexciting forces occurring close to tire natural frequencies of TLPs often give greater contributions to high and law frequency resonant responses. Nonlinear motion responses and tension variations in the time domain are analyzed by solving the motion equations with nonlinear wave exciting forces using tire numerical analysismethod. The numerical results of time domain analysis for the nonlinear wave exciting forces on the ISSC TLP in regular waves are compared with the numerical and experimental ones of frequency domain analysis. The results of this comparison confirmed tire validity of the proposed approach.

메탄올 액적 화염의 음향파 가진에 의한 재점화 (Reignition of Methanol Droplet Flames Under Acoustic Pressure Oscillation)

  • 김홍집;손채훈;정석호
    • 대한기계학회논문집B
    • /
    • 제23권1호
    • /
    • pp.114-122
    • /
    • 1999
  • Reignition as special cases of acoustic pressure responses of flame are numerically studied by employing methanol droplet flame as a laminar flamelet. Quasi-steady flame responses occur in the range of small amplitude, low frequency oscillation. Reignition phenomena can occur when, by increasing the frequency of large amplitude acoustic pressure, the magnitude of characteristic acoustic time is the same order of that of characteristic reaction time of flames. And more increasing of amplitude of acoustic pressure induces the direct extinction of flame. Flame can sustain its own intensity even under the steady extinction temperature in case of high frequency acoustic oscillation, and this tendency is remarkable with increasing frequency. Reignition regime with respect to amplitude and frequency of acoustic pressure doesn't exist in low frequency($10^2$ Hz, in this study), but broadens with frequency of acoustic pressure.

Effects of the Insulation Quality on the Frequency Response of Power Transformers

  • Abeywickrama Nilanga;Ekanayake Chandima;Serdyuk Yuriy V.;Gubanski Stanislaw M.
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권4호
    • /
    • pp.534-542
    • /
    • 2006
  • This paper presents results of frequency domain spectroscopy (FDS) measurements on oil-impregnated pressboard insulation, their analyses and use of the data for modeling high frequency response (FRA) of transformers. The dielectric responses were measured in a broad frequency range, i.e. from 0.1 mHz to 1 MHz, on model samples containing different amount of moisture. The responses were parameterized with terms representing dc conductivity, low frequency dispersion and Cole-Cole polarization mechanisms and they were thereafter used to model the FRA response of a three-phase transformer.

푸리에 변환과 주파수 민감도를 이용한 시변자장 시스템에서의 과도상태 해석 (Transient Analysis of Magnetodynamic Systems Using Fourier Transform and Frequency Sensitivity)

  • 최명준;김창현;박일한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.64-66
    • /
    • 1998
  • This paper presents a new efficient method for transient analysis in magnetodynamic systems of linear eddy current problems. This mehtod employs the Fourier transform and the high-order frequency sensitivity of harmonic finite element method. By taking into account the time-constant of magnetodynamic system, the Fourier integral of continuous frequency is converted into the Fourier series of discrete frequency. And with the results of Fourier series expansion of converted input wave form, the responses of each sinusoids is superposed to give the total response of the magnetodynamic systems. But, if the frequency band of input wave form is broad, it takes long computational time since all responses for each sinusoids must be calculated. Therefore, the high-order frequency sensitivity method is employed to estimate the response variation to frequency. The proposed algorithm is applied to an induction heating system to validate its numerical efficiency.

  • PDF

경부미주신경의 전기자극에 의한 지속성 심박반응 및 이의 심전도적 고찰 (The Prolonged Heart Rate Responses to Electrical Stimulation of Vagus Nerve in Dogs)

  • 신홍기;김기순
    • The Korean Journal of Physiology
    • /
    • 제6권2호
    • /
    • pp.31-37
    • /
    • 1972
  • The right cervical vagus nerve was electrically stimulated for 30 sec, and 30 minutes recording cardiac rate responses and electrocardiogram. The main purposes of the present experiment are to determine effect of stimulation frequency on the maintenance of cardiac rate responses and to determine recovery time of sinus rhythm after asystole period followed by idioventricular rhythm during prolonged electrical stimulation of the vagus, and the optimal stimulation parameters for vagal stimulation were studied as well. The results obtained are summarized as follows: 1. The maximum negative chrontropic responses were obtained with the following ranges of electrical parameters. Intensity: 3V-7V, Frequency: 20/sec-60/sec, and pulse duration: 5 msec-20 msec. 2. Compared with the responses from sympathetic effectors, cardiac rate responses to electrical stimulation of vagus nerve were well maintained with all stimulation frequencies. 3. At all stimulation frequencies except 20/sec, sinus node started to take over primary pacemaker activity when cardiac rates were restored to about 38-40/min. 4. It was indicated that upper limit of idioventricular rhythm does not exceed 38-40/min. 5. With the stimulation parameter set of 20/sec-5 msec-3 V, sinus rhythm did not appear during 30 minutes of stimulation period. Therefore, this electrical parameter set appears to be optimal for elicitation of prolonged and maximum cardiac rate responses by vagal stimulation.

  • PDF

CF/Epoxy 복합적층판의 저속충격 특성평가에 관한 연구 (A Study on Characteristics Analysis of Low Velocity Impact Response of CF/Epoxy Composite Plates)

  • 임광희;박노식;김영남;김정호;김선규;심재기;양인영
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 춘계학술발표대회 논문집
    • /
    • pp.85-88
    • /
    • 2002
  • We have implemented a system of falling weight impact tester. Absorbed energy of orthotropic composites with using T300 fiber, which are composed of the same fiber and stacking number is higher than that of quasi-isotropic specimen over impact energy 7J, but in case of using T700 fiber, much difference does not show. Also, absorbed energy of orthotropic composites with using T300 fiber, which are composed of stacking number and orientation became more than that of T700 fiber specimen; however great change doesn't show in case of quasi-isotropic specimens. Delamination area of impacted specimens was measured with ultrasonic C-scanner to find correlation between impact energy and delamination area. Delamination area and frequency responses was evaluated between impacted and unimpacted specimens. There is a strong correlation between frequency responses and impact-induced delamination. The presence and scale of damages have been investigated based on the variations of frequency responses.

  • PDF