• Title/Summary/Keyword: frequency comb

Search Result 123, Processing Time 0.025 seconds

Integration of a micro lens on a in-plane positioning actuator with 2-DOF (마이크로 렌즈가 집적된 2-자유도 평면구동기의 설계 및 제작)

  • Kim, Che-Heung;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3322-3324
    • /
    • 1999
  • This paper studies on the design and fabrication of a micro in-plane positioning actuator integrated with a microlens. Proposed in-plane actuator is a micro XY-stage which is composed of two linear comb drive actuators being orthogonal to each other. In the fabrication of actuator, the single crystalline silicon substrate anodically bonded with a #7740 glass substrate is used because of simple release and passivation. The structure of actuator is formed on the silicon facet of bonded fixture by chlorine-based deep RIE and then released by isotropic wet etching of glass (#7740) in hydrofluoric acid solution. Fabricated actuator has a large travel range up to $30({\pm}15){\mu}m$ and high resolution less than 0.01f1l1l in each direction. Experimented resonant frequency of this actuator is 630Hz. The micro-Fresnel lens is fabricated on the square-shape glass structure prepared in the center of actuator.

  • PDF

Ultrafast Femtosecond Lasers: Fundamentals and Applications (펨토초 레이저의 원리 및 응용)

  • Kim, Young-Jin;Kim, Yun-Seok;Kim, Seung-Man;Kim, Seung-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.6
    • /
    • pp.7-16
    • /
    • 2010
  • Physical fundamentals of ultrashort femtosecond lasers are addressed along with emerging applications for precision manufacturing and metrology. Femtosecond lasers emit short pulses whose temporal width is in the range of less than a picosecond to a few femtoseconds, thereby enabling extremely high peak-power machining with less thermal damages. Besides, the broad spectral bandwidth of femtosecond lasers constructed in the form of frequency comb permits absolute distance measurements leading to ultraprecision positioning control and dimensional metrology.

Effect of Acoustic Reflector's Surface Density on Sound Absorption Characteristics and Stage Acoustics (음향 반사판의 밀도별 흡음특성 및 무대음향에의 영향)

  • Kim, Young-Sun;Jeong, Jeong-Ho;Jeon, Jin-Yong;Kim, Myeong-Seok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.5
    • /
    • pp.429-436
    • /
    • 2012
  • In concert halls and auditoriums, acoustic reflector and stage enclosure is one of the main factors on the room and stage acoustic characteristics. As a stage enclosure and acoustic reflector honey comb based light-weight reflector is widely used, because it is easy to install. However, there was not enough research on the surface density effect on room and stage acoustics. In this study, sound absorption coefficient tests on three kinds of wooden acoustic reflectors with different surface density were conducted. Surface density of acoustic reflector was changed from 11 kg/$m^2$ to 41 kg/$m^2$. For the low frequency excitation, sub-woofer was used with omnidirectional loud-speaker simultaneously. From the experiments, it was found that sound absorption coefficient below 250 Hz band was decrease by the increment of surface density. In order to check the influence of the surface density on room and stage acoustic parameters, room acoustic simulation was conducted with sound absorption coefficients, which were tested in reverberation chamber. By the increment of surface density of acoustic reflector, RT(reverberation time) and EDT(early decay time) were increased. Also, ST(stage support) was improved in low frequency bands.

Study on the Radiation Pattern of Radiated Emission above 1 GHz (1 GHz 이상에서의 복사 방출 방사 패턴에 관한 연구)

  • Chung, Yeon-Choon;Lee, Soon-Yong;Kwun, Suk-Tai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.3
    • /
    • pp.336-344
    • /
    • 2011
  • The purpose of this study is to analyze the radiation-pattern characteristics above 1 GHz for the electromagnetic wave radiated from multi-slot such as ventilations, etc. on the enclosure of an EUT and so to make recommendations for suitable test methods. An experimental EUT was formed by putting a comb-generator at the center of a rectangular enclosure with 4 slots, and its radiation pattern was analyzed in the frequency range of 1~6 GHz. As analysis results, multi-lobe appears above 2 GHz and the number of multi-lobes is growing as the frequency increases. And real radiated-emission measurements were performed for the experimental EUT by scanning a receiving antenna in the height of 1~4 m and tilting toward maximum radiation, as well as setting the height of a receiving antenna to the central position of the EUT which is prescribed at the present standards. The measured results are +12.8 dB in the scanning and +16.4 in the scanning and tilting compared with the present standard test method. Therefore, the latter must be revised in order to consider the radiation pattern above 1 GHz.

Development of Ultrasound Sector B-Scanner(III)-Pulsed Ultrasonic Doppler System- (초음파 섹터 B-스캐너의 개발(III)-초음파 펄스 도플러 장치-)

  • 백광렬;안영복
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.139-146
    • /
    • 1986
  • Pulsed ultrasonic Doppler system is a useful diagnostic instrument to measure blood-flow-velocity, velocity profile, and volume-blood-flow. This system is more powerful compare with 2-dimensional B-scan tissue image. A system has been deve- loped and ii being evaluated using TMS 32010 DSP. We use this DSP for the purpose of real-time spectrum analyzer to obtain spectrogram in singlegate pulsed Doppler system and for the serial comb filter to cancel clutter and zero crossing counter to estimate Doppler mean frequency in multigate pulsed Doppler system. The Doppler shift of the backscattered signals is sensed in a phase detector. This Doppler signal corresponds to the mean velocity over a some region in space defined by the ultrasonic beam dimensions, transmitted pulse duration, and transducer ban(iwidth. Multi- gate pulsed Doppler system enable the transcutaneous and simultaneous assessment of the velocities in a number of adjacent sample volumes as a continuous function of time. A multigate pulsed Doppler system processing the information originating from presented.

  • PDF

Channel Estimation for Scattered Pilot Based OFDM Systems (분산 파일럿 기반의 OFDM 시스템의 채널 추정)

  • Kim, See-Hyun
    • Journal of IKEEE
    • /
    • v.15 no.3
    • /
    • pp.235-240
    • /
    • 2011
  • The scattered pilots employed in DVB-T take advantage of the merits of both the block type and comb type pilot arrangement to increase the transmission efficiency. To estimate the channel transfer functions for data subcarriers, it is required to conduct time-frequency domain 2D estimation using the pilots. Though 2D Wiener estimator is optimal in sense of MSE (mean square error), it is too complex to implement in hardware. In this paper a new channel estimation method for the scattered pilot based OFDM system by measuring the power of AWGN and removing the noise in the LS (least square) estimate of the channel is proposed. And the simulation results reveal the proposed method outperforms the 2D linear interpolation in the fading channel.

Electrostatic Microactuators operated at low drive voltages Using Triangular Tip (삼각 팁을 이용한 저전압 구동형 정전방식 마이크로액추에이터)

  • Kim, Bong-Hwan;Seong, U-Gyeong;Jeon, Guk-Jin
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.9
    • /
    • pp.605-610
    • /
    • 2001
  • Electrostatic comb-drive microactuators with sub-micron gap were fabricated and tested. We designed and fabricated two type of electrodes which are rectangular and triangular tip. The fabricated microactuators with triangular tip resulted in the electrode gaps in the range of 0.55 ${\mu}{\textrm}{m}$~1.35 ${\mu}{\textrm}{m}$ Displacement of 1 ${\mu}{\textrm}{m}$ and electrostatic force of 2.3 $\mu$N were observed in a triangular-tip microactuator with 0.55 ${\mu}{\textrm}{m}$ gap when a DC drive voltage of 13 volts was applied. Measured 1st resonance frequency of microactuators was about 23 kHz.

  • PDF

A Design of the Demapper Using Channel State Information for COFDM Demodulator (COFDM 복조기에서의 채널상태정보를 이용한 디매퍼의 설계)

  • Kang, Kyung-Jin;Lee, Weon-Cheol
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.10
    • /
    • pp.21-29
    • /
    • 1999
  • This paper is concerning about the demapping method using the pilots inserted in transmitter in COFDM(Coded Orthogonal Frequency Division Multiplexing) demodulator which is the standard transmission method of terrestrial digital TV system in Europe(DVB-T). We have presented a simple and efficient method of CSI(Channel State Information) generation and demapping method using CSI. The CSI was derived from the pilot carriers inserted with comb-type among the received active carriers, which is defined as a SNR. From the simulation results for the 3 different constellations of the receiver, we could confirm that the system performance comparing with conventional soft decision method has been improved under DVB-T standard Rayleigh and Ricean fading channel.

  • PDF

Performance Comparison of Channelization Schemes for Flexible Satellite Transponder with Digital Filter Banks (디지털 필터뱅크 기반 플렉서블 위성중계기를 위한 채널화 기법의 성능비교 연구)

  • Lee, Dong-Hun;Kim, Ki-Seon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.405-412
    • /
    • 2010
  • The purpose of this paper is to compare complexity and to assess flexibility of competing transponder architectures for satellite communication services. For performance comparison, we consider three channelization techniques: digital down converter(DDC) based on the use of the cascaded integrator-comb(CIC) filter, tuneable pipeline frequency transform(T-PFT) based on the tree-structure(TS) and variable oversampled complex-modulated filter banks(OCM-FB) based on the polyphase FFT(P-FFT). The comparison begins by presenting a basic architecture of each channelization method and includes analytical expressions of the number of multiplications as a computational complexity perspective. The analytical results show that DDC with CIC filter requires the heavy computational burden and the perfect flexibility. T-PFT based on the TS provides the almost perfect flexibility with the low complexity over DDC with the CIC filter for a large number of sub-channels. OCM-FB based on the P-FFT shows the high flexibility and the best computational complexity performance compared with other approaches.

A Comparative Study on the Characteristics of Thermoacoustic Waves by the Stack Channel Number (스택의 채널 수에 다른 열음향파의 특성 비교 연구)

  • Park, Sung-Seek;Cheon, Won-Gi;Kim, Nam-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.8-14
    • /
    • 2013
  • The conversion of solar energy into acoustic waves is experimentally studied. Measurements were made on the Sound Pressure Level(SPL), onset time and the temperature gradient across the stack, with the Cell Per Square Inch(CPSI) of stack changed. A pyrex resonance tube is used with a honey-comb structure ceramic stack along with Ni-Cr and Cu wires. An AL1 acoustical analyzer was used to measure the SPL and frequency of acoustic waves whereas K-type thermocouples were hired to estimate temperature gradients. As a result, when the supply electric power was 25W, maximum SPLs of 104.1 dB, 109.4 dB and 112.8 dB were detected for the stacks of 200, 300 and 400 CPSI and their respective stack positions of 70mm, 60mm and 50mm from the closed end.