• Title/Summary/Keyword: frequency and correlation analysis

Search Result 2,821, Processing Time 0.026 seconds

Validity of Self-administered Semiquantitative Food Frequency Questionnaire by Conditions of One Portion Size (식품섭취빈도조사법의 1회 섭취분량 제시여건에 따른 정확도에 관한 연구)

  • 김미자;김영옥;김석일
    • Korean Journal of Community Nutrition
    • /
    • v.3 no.2
    • /
    • pp.273-280
    • /
    • 1998
  • This study was designed to estimate the improvement of Validity for food frequency questionnaire(FFQ) by offering multiple choice portion size in developing a questionnaire. Validity of the two methods(food frequency questionnaire I=FFQ I & Food frequency questionnaire II=FFQ II) was tested in comparison with reference method of the 7-day weighed record(7DWR). Dietary consumption data of the three methods(FFQ I, FFQ II & 7DWR) were collected from 101 female university students for the analysis. Validity was measured in two categories : One was the nutrient intake value from the three methods, the other was the identification of between individual variation within the group. Spearman's rank order correlation test and distribution graphs were used for the analysis. The result showed that individual intake value of the FFQII was closer to that of the 7DWR than that of the FFQ I.Spearman's rank order correlation between the FFQII and the 7DWR did not show any improved correlation. The distribution graphs of nutrient intake derived from both the FFQ I and the FFQII were different from that of the 7DWR. Therefore, it could be suggested that single one portion size food frequency questionnaire is an equally efficient method as a multiple choice food frequency questionnaire to be adopted in epidemiologic studies.

  • PDF

Vibration Characteristics of Boxthorn(Lycium chinense Mill) (구기자 가지의 진동 특성)

  • 서정덕
    • Journal of Biosystems Engineering
    • /
    • v.26 no.2
    • /
    • pp.105-114
    • /
    • 2001
  • Modulus of elasticity, modulus of rigidity, damping ratio, and natural frequency of three varieties of boxthorn (Lycium chinense Mill) (Cheongyang #2, Cheongyang gugija, and Cheongyang native) branches were analyzed. Modulus of elasticity and modulus of elasticity and modulus of rigidity of the boxthorn branch was determined using standard formula after simple beam bending and torsion test, respectively, using an universal testing machine. Damping ratio and natural frequency of branches were determined using a system consisted of an accelerometer, a PC equipped with A/D converter, and a software for data analysis. Relationship between the elastic modulus and branch diameter in overall varieties and branch types showed a good correlation (r -0.81). There was, however, no correlation between torsional rigidity and branch diameter. The internal damping results were highly variable and the overall range of the damping ratio of the boxthorn branch was 0.014-0.087, which indicated that the branch was a lightly damped structure. The natural frequency of the boxthorn branch was in the range of 89-363 rad/s for the overall varieties and branch types. A good correlation (r 0.82) existed between the natural frequency and branch diameter in overall varieties and branch type.

  • PDF

Study of Design Flood Estimation by Watershed Characteristics (유역특성인자를 이용한 설계홍수량 추정에 관한 연구)

  • Park, Ki-Bum
    • Journal of Environmental Science International
    • /
    • v.15 no.9
    • /
    • pp.887-895
    • /
    • 2006
  • Through this research of the analysis on the frequency flood discharges regarding basin property factors, a linear regression system was introduced, and as a result, the item with the highest correlation with the frequency flood discharges from Nakdong river basin is the basin area, and the second highest is the average width of basin and the river length. The following results were obtained after looking at the multi correlation between the flood discharge and the collected basin property factors using the data from the established river maintenance master plan of the one hundred twenty-five rivers in the Nakdong river basin. The result of analysis on multivariate correlation between the flood discharges and the most basic data in determining the flood discharges as basin area, river length, basin slope, river slope, average width of basin, shape factor and probability precipitation showed more than 0.9 of correlation in terms of the multi correlation coefficient and more than 0.85 for the determination coefficient. The model which induced a regression system through multi correlation analysis using basin property factors is concluded to be a good reference in estimating the design flood discharge of unmeasured basin.

A Study on the Precise Distance Measurement for Radar Level Transmitter of FMCW Type using Correlation Anaysis Method (상관분석법을 이용한 FMCW 타입 레이더 레벨 트랜스미터의 정밀 거리 측정에 관한 연구)

  • Ji, Suk-Joon;Lee, John-Tark
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.7
    • /
    • pp.1024-1031
    • /
    • 2012
  • In this paper, FMCW type radar level transmitter using correlation analysis method is implemented for precise distance measurement of cargo tank. FMCW type radar level transmitter is the device for distance measurement which calculates the distance by analyzing the beat frequency, that is, the frequency difference between Tx and RX signal from radar antenna using Fast Fourier Transform(FFT), but compensated algorithm like Zoom FFT is needed for the improvement of the frequency precision because the frequency precision of FFT is limited depending on sampling frequency and the number of sampling data. In case of Zoom FFT, the number of sampling data and noisy signal are the main factor influencing the measurement accuracy of Zoom FFT like FFT. Therefore, in order to overcome the limited environment and achieve the precise measurement, correlation coefficient is used for the distance measurement and the errors of measurement are verified to be in the range of ${\pm}1mm$.

An Empirical Analysis on the Certificate Examination for Marine Officer (해기사 국가 자격 시험 실증 분석)

  • Park, Jong-Un;Lee, Hak-Hun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.19 no.1
    • /
    • pp.19-28
    • /
    • 2007
  • The aim of this study is to analyze the frequency of the mark points of all examination subjects, the correlation between all examination subjects and the factors to influence pass of the examination. The methodology of this study are as follows.1. The descriptive analysis mark points of the examination subjects. 2. The correlation analysis between the examination subjects. 3. The multiple regression analysis among the examination subjects. Every mark points tend to be changed in wide ranges according to the student's learning ability. On the certificates examination for marine officers, Students in deck part recorded higher in rate of successful applicants, but showed more subject failure than those in engine part. It is especially suggested for the students to improve the teaching and learning skills of the subject. The high correlation subject to total and average points were found in English subject. The high correlation subject was shown between English & Ship handling, Engineering 1&2 and English & Engineering 1,2,3. The most influential subjects to pass the examination were Navigation, English, Engineering 3.

Continuous Variable Regression Analysis for Frequency of Damage Analysis in Heat Pipe (연속형 변수 회귀분석을 통한 열수송관 파손빈도 분석)

  • Myeongsik Kong;Jaemo Kang;Sungyeol Lee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.12
    • /
    • pp.47-52
    • /
    • 2023
  • In order to efficiently maintain heat pipes operated by district heating operators, the facility history and damage history data built by the operator are used to identify key independent variables that are related to the occurrence of damage. Afterwards, the correlation with the frequency of damage was analyzed, and a basic model for estimating the frequency of damage was derived. Considering the correlation with the estimation model based on the use time currently being used by domestic and foreign district heating operators, a simple regression analysis basic model was presented as the independent variable with the highest correlation between continuous variables such as the use time, pipe diameter, burial depth, and insulation level of monitoring system, and the frequency of damage. The remaining independent variables were reflected as factors that modify and supplement the basic model. As a result of the analysis, as in previous research cases, it was confirmed that the analysis model between use time and frequency of damage had the highest correlation between the two variables and could be used as a basic model. Pipe diameter, burial depth, and insulation level of monitoring system information have also been confirmed to have a correlation with the frequency of damage, so they can be used as factors to supplement the basic model.

An improved cross-correlation method based on wavelet transform and energy feature extraction for pipeline leak detection

  • Li, Suzhen;Wang, Xinxin;Zhao, Ming
    • Smart Structures and Systems
    • /
    • v.16 no.1
    • /
    • pp.213-222
    • /
    • 2015
  • Early detection and precise location of leakage is of great importance for life-cycle maintenance and management of municipal pipeline system. In the past few years, acoustic emission (AE) techniques have demonstrated to be an excellent tool for on-line leakage detection. Regarding the multi-mode and frequency dispersion characteristics of AE signals propagating along a pipeline, the direct cross-correlation technique that assumes the constant AE propagation velocity does not perform well in practice for acoustic leak location. This paper presents an improved cross-correlation method based on wavelet transform, with due consideration of the frequency dispersion characteristics of AE wave and the contribution of different mode. Laboratory experiments conducted to simulate pipeline gas leakage and investigate the frequency spectrum signatures of AE leak signals. By comparing with the other methods for leak location identification, the feasibility and superiority of the proposed method are verified.

Severity of Obstructive Sleep Apnea and Heart Rate Variability : Detrended Fluctuation Analysis (폐쇄성 수면 무호흡증의 심각도와 심박동 변이율 : 탈경향변동분석)

  • Ju, Gawon;Shin, Chul-Jin;Park, Doo-Heum
    • Korean Journal of Biological Psychiatry
    • /
    • v.16 no.2
    • /
    • pp.69-75
    • /
    • 2009
  • Objectives : The detrended fluctuation analysis is one of the nonlinear methods for the investigation of biological time series. It quantifies the fractal scaling properties and is known to be useful in the evaluation of long-range correlations in time series. The heart rate variability(HRV) of obstructive sleep apnea syndrome (OSAS) patients during nighttime was analyzed by detrended fluctuation analysis to assess its relationship with the severity of the symptoms. Methods : Fifty nine untreated male OSAS patients with moderate to severe symptoms(mean age=45.4${\pm}$11.7 years, apnea-hypopnea index, AHI${\geq}$15) underwent nocturnal polysomnography. Moderate(AHI=15-30, N=22) and severe(AHI>30, N=37) OSAS patients were compared for the indices derived from detrended fluctuation analysis and frequency domain analysis of HRV. Results : In the detrended fluctuation analysis, the alpha values were 0.75${\pm}$0.11 and 0.82${\pm}$0.07 for the severe and the moderate OSAS groups respectively. The difference was significant(p<.01). The alpha value had negative correlation with AHI(r=-.425, p=.001). Negative correlation coefficients were also found in the relationships between the alpha values and very low frequency(VLF)(r=-.425, p=.001), low frequency(LF)(r=-.633, p= <.001) and the LF/HF ratio(r=-.305, p=.019) respectively. LF/HF ratio(p=.005) was higher in the severe OSAS group compared to that of the moderate OSAS group. Conclusion : In this study, the detrended fluctuation analysis showed the significant difference between the two OSAS groups classified according to their severity of symptoms. The scaling exponent showed the negative correlation with AHI and indicies of frequency domain analysis. This result suggests that detrended fluctuation analysis can be helpful to estimate the severity of OSAS.

  • PDF

Replica Correlation-Based Synchronization with Low Complexity and Frequency Offset Immunity

  • Chang, Kapseok;Bang, Seung Chan;Kim, Hoon
    • ETRI Journal
    • /
    • v.35 no.5
    • /
    • pp.739-747
    • /
    • 2013
  • This paper investigates the multifarious nature of the long-term evolution (LTE) scheme and that of the modified LTE scheme for symbol timing synchronization (STS). This investigation allows us to propose a new replica correlation-based STS scheme to overcome the inherent weaknesses of the other two schemes. The proposed STS signal combines a gold sequence and a half sine wave in the time domain, whereas conventional STS signals specify either binary sequences or complex sequences in the time domain or in the frequency domain. In the proposed scheme, a sufficient correlation property is realized by the gold sequence, and robustness against the frequency offset (FO) is achieved through the sine wave. Compared to the existing LTE-related schemes, the proposed scheme can better achieve immunity to FO and reduction in detector complexity, as well as a low peak-to-average power ratio and a low detection error rate. Performance evaluations through analysis and simulation are provided in the paper to demonstrate these attributes.

Estimation of Fault Location on a Power Line using the Time-Frequency Domain Reflectometry (절연전선 결함 위치 추정에 대한 시간-주파수 영역 반사파 계측법의 적용)

  • Doo, Seung-Ho;Kwak, Ki-Seok;Park, Jin-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.268-275
    • /
    • 2008
  • In this paper, we introduce a new method for detecting and estimating faults on a power line using the time-frequency domain reflectometry system. The system rests upon time-frequency signal analysis and uses a chirp signal which is multiplied by Gaussian envelope. The chirp signal is used as a reference signal, and we can get the reflected signal from a fault on a wire. To detect and estimate faults, we analyze the reflected signal by Wigner time-frequency distribution function and normalized time-frequency cross correlation function. In this paper we design an optimal reference signal for power line and implement a system for estimating fault distance on a power line with the TFDR implemented by PXI equipments. This approach is verified by some experiments with HIV 2.25mm power lines.