• Title/Summary/Keyword: freezing air temperature

Search Result 159, Processing Time 0.02 seconds

Changes in Quality during Frozen Storage of Meat with Thermal Equalized Freezing (균온처리 동결에 의한 식육의 저장중 품질변화)

  • Jeong, Jin-Woong;Lee, Ho-Jun;Park, Noh-Hyun
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.688-696
    • /
    • 1999
  • Changes in quality during frozen storage of meat with thermal equalized freezing and various freezing methods were investigated. When beef were frozen at freezing rate of $0.39{\sim}0.66\;cm/h$, average diameter of ice crystal were about $30{\sim}50\;{\mu}m$ and showed broken tissues or irregular cracks. At freezing velocity of $1.14{\sim}2.26\;cm/h$, ice crystals of about $10{\sim}30\;{\mu}m$ was formed mainly inside or between fiber and slight destruction of tissues was occurred. The average diameter (D) of the ice crystals were related to the characteristic freezing time $(t_c)$ by the equation: $D({\mu}m)=4.089+26.88logt_c\;(r^2=0.913)$. Beef with still-air freezing showed higher drip loss than methods of immersion and thermal equalized freezing. Also, drip loss of pork was relatively lower than beef and showed highest value to 7.39% during storage on 40 days at air-blast freezing method. No apparent change of pH during storage of frozen beef and pork by freezing methods were detected. However, least changes for sample with thermal equalized freezing was found compare to sample with still-air and air blast freezing in VBN and TBA value. The fluctuation of frozen storage temperature did not cause noticeable changes on pH and water content. However, drip loss, VBN and TBA values were increased slowly as frequency of fluctuation increased.

  • PDF

Storage Characteristics of Rough Rice by Storage Method (저장방법에 따른 벼의 저장특성)

  • Lee, J.S.;Hong, H.K.;Kang, T.H.;Li, H.;Ham, T.M.;Kim, Y.H.;Han, C.S.
    • Journal of Biosystems Engineering
    • /
    • v.33 no.3
    • /
    • pp.167-172
    • /
    • 2008
  • The objective of this study was to investigate the adequate storage method that was able to maintain the high quality of rough rice according to storage methods and period. The quality change of the rough rice during the storage period was evaluated by storage method such as cooling bin using winter cold air, ordinary temperature bin, freezing, refrigeration and indoor storage. Moisture content, brown rice whiteness, hardness, crack ratio and germination ratio were measured in this study. Moisture content of rough rice stored in cooling bin using winter cold air and ordinary temperature bin were decreased by 0.07% and 0.42%, respectively, which were lower than the other storage method. The hardness of brown rice increased in order of storage method such as winter cooling bin, normal bin, freezing storage, refrigeration storage and indoor storage. Crack ratio by indoor and ordinary temperature bin storage were increased by 2.68% and 3.63%, respectively, whereas cooling bin using winter cold air, refrigeration and freezing storage showed below 1.0%. The highest germination rate was found in cooling bin using winter cold air. As a result, cooling bin using winter cold air can be evaluated for the adequate storage method of rough rice.

Case Studies on Freezing Rain over the Korean Peninsula Using KLAPS (KLAPS를 이용한 한반도 어는비 사례 연구)

  • Kwon, Hui-Nae;Byun, Hi-Ryong;Park, Chang-Kyun
    • Atmosphere
    • /
    • v.25 no.3
    • /
    • pp.389-405
    • /
    • 2015
  • In this study, the occurrence circumstances of 3 cases (12 Jan 2006, 11 Jan 2008, 22 Feb 2009) when the freezing rain was observed at more than two observatories in a day with more than three times each observatory, were investigated. Following the advanced study about the same cases, we have tried to find more delicate differences in using the Korea Local Analysis and Prediction System (KLAPS; 5 km reanalysis data) that has the smallest grid scale at current situation. As results, three common characteristics are found: (1) Just before the occurrence of the freezing rain, the wind direction was consistently continuous and the wind speed was constant or gradually increased for at least 3 hr more. (2) Surface air temperature (Relative humidity) was respectively $3.08^{\circ}C$ (28.76%), $0.47^{\circ}C$ (50.07%) and $-3.60^{\circ}C$ (71.07%) 3 hr ago to break out the freezing rain. It means the freezing rain occurs in a wide range of atmospheric environments. However, the closer it got to the occurrence time of the freezing rain, the closer the surface air temperature was to $0^{\circ}C$, and the bigger the humidity of the surface air was. (3) The liquid precipitation formed in the upper atmosphere, met a cold advection bellower than 950 hPa level and suspected to be changed to the super-cooled condition.

Nature of Cold Injury and Resistance in Wheat and Barley (맥류의 한해와 내동성에 관하여)

  • 남윤일;연규복;구본철
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.34 no.s02
    • /
    • pp.96-114
    • /
    • 1989
  • There are several meterorolgical stresses in the winter cereal crops. Among these stresses, cold injury is one of the most important stresses for wheat and barley production in Korea. The reduction in grain yield of the wheat and barley due to cold injury has occurred almost every year in Korea. The objective of the study was to get the basic information in relation to the cold injury and to detect the method minimizing the damage of cold injury. When the air temperature was the ranges of -13$^{\circ}C$ to -15$^{\circ}C$, the soil temperature at the crown part of the plant was very stable, whereas in the ranges of -2$^{\circ}C$ to -3$^{\circ}C$ the soil surface temperature was more unstable and cold than air and subterranean temperatures. The different parts of the plant in wheat and barley possess the different levels of cold hardiness. In comparison to the cold hardiness of plant parts, the leaf and crown are the less sensitive to cold injury than root and vascular transitional zone. The type and extent of stress is determined by the redistribution pattern of water during freezing. These types from freezing processes were three types: a) Equilibrium freezing pattern b) Non -equilibrium freezing pattern, c) Non-equilibrium freezing pattern typical of tender tissues. Cold hardiness in wheat plants were more harder than barley plants at vegitative stage, but inverted at the reproductive stage. Injuries by low temperature during the seasons of barley cultivation in Korea were occured mainly in four stage; in the first and third stage, frost injury occurs, the second stage, freezing injury, and the fourth stage, chilling injury.

  • PDF

Freezing Injury of Evergreen Broad-Leaved Trees in Warm-Temperature in the Southern Region in Korea -A Case of Machilus Thunbergii Siebold & Zucc. on the Jungma-dong, Gwangyang-city, Jeollanam Province- (한국 남부지방 난온대성 상록활엽수의 동해피해 -전라남도 광양시 중마동의 후박나무를 중심으로-)

  • Lee, Ki-Won;Kim, Do-Gyun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.20 no.1
    • /
    • pp.77-96
    • /
    • 2017
  • This study was carried out to clarify the climatic factors of the freezing injury for the judgement on the adaptation areas of evergreen broad-leaved trees. We surveyed and analyzed the climatic factors of the freezing injury to Machilus thunbergii Siebold & Zucc. on the streets with the analyzation of planting grounds, soil conditions and the surrounding buildings. This study showed that only the minimum air temperature factor out of the other climate elements, which were the annual precipitation; the average annual temperature; the average monthly temperature of january; the average monthly minimum temperature of January; the average temperature of the coldest month; the warmth index and the coldness index, was matched up with the previous theories and reports on the freezing damages on the evergreen broad leaved trees and Machilus thunbergii Siebold & Zucc. The freezing injury of Machilus thunbergii Siebold & Zucc was occurred when the mean minimum temperature of the coldest month(TMC) in winter season fell down below $-4.1^{\circ}C$ and the temperature fell down below $-9.2^{\circ}C$. The freezing damage on Machilus thunbergii Siebold & Zucc surrounded by high buildings were less than those surrounded by low buildings or at non buildings.

Computing Procedure of Daily Average Air Temperature using Field Data and Frost Index Calibration for Anti-Frost Heave Layer Design (현장계측 데이터를 이용한 일평균 대기온도 산정방법과 동상방지층 설계를 위한 동결지수 보정)

  • Cho, Myung-Hwan;Kim, Nakseok;Shim, Jaepill
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3D
    • /
    • pp.433-439
    • /
    • 2011
  • The frost depth(frost penetration) is used to install anti-frost heave layers in pavement designs. The freezing index is calculated by an annual accumulated value of multiplying the period of time with temperatures below zero, and the corresponding temperature. Therefore, the DAAT(daily average air temperature) calculation method may play an effect on the FI(freezing index). The Weather Observatory used to supply 4 average air temperatures per day, but currently supplies 8 per day. With this study, we divided the southern part(below FI=$350^{\circ}C{\cdot}day$) of the Korean peninsula into 6 areas according to site conditions(low embankment, embankment-cutting slope, and the cutting slope) and established a field measurement system for 15 positions to check the effects on the result of FI according to differing DAAT calculation methods. The air temperatures obtained by the field measurement system was used to calculate and compare the FI. As a result, the freezing index calculated based on the $DAAT_4(T_4)$ is normally greater by 3% than the one on $DAAT_8(T_8)$. In addition, the calibration equation for the freezing index using air temperatures was proposed through the research.

An Experimental Study on Sea Water Freezing Behavior Along Horizontal Cooled Cylinder With Bubbly Flow (기포를 동반한 유동장에서의 냉각원과 주위의 해수동결에 관한 실험적 연구)

  • Park, D.S.;Yoon, S.H.;Kim, M.H.;Lee, Y.H.;Oh, C.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.825-832
    • /
    • 2001
  • This study was experimentally performed to investigate freezing behavior of sea water along horizontal cooled a circular tube with bubbly flow. The experiments were carried out for a variety of parameter, such as sea water velocity, air-bubble flow rate, and cooled-tube temperature. The shape of freezing layer, freezing rate and salinity of frozen layer were observed and measured. And the flow patterns around cooled tube were visualized using the PIV to analyze the relationship between the flow structure and the freezing characteristics. It was found that the experimental parameters gave a great influence on the freezing rate and the salinity of the frozen layer.

  • PDF

Phase-change Temperature of Micro-encapsulated Phase-change Material (미립 피복 상변화 물질의 상변화 온도에 대한 연구)

  • 최은수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.2
    • /
    • pp.168-174
    • /
    • 2002
  • In order to obtain a new heat transfer fluid having a high thermal capacity, micro-capsules of a phase-change material can be a successful candidate to be added into water. In this study, 25, 50, 100, and $200\mu$m diameter micro-encapsulated Lauric acids were tested by a differential scanning calorimeter. The Lauric acid itself had a single freezing curve, but the micro-encapsulated Lauric acid had double freezing curves. The second freezing dominated for $25\mu$m diameter Lauric acids. But the first freeing energy became big as the size of the capsule increased.

AN EXPERIMENTAL STUDY ON SEA WATER FREEZING BEHAVIOR FOR DEVELOPMENT OF SEA WATER DESALINATION SYSTEM (해수 동결담수화장치 개발을 위한 해수동결에 관한 실험적 연구)

  • Park, D.S.;Kim, M.H.;Oh, C.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.6
    • /
    • pp.1250-1259
    • /
    • 2001
  • This study was experimentally performed to investigate sea water freezing behavior along parallel cooled plate with bubbly flow The experiments were carried out for a variety of parameter, such as sea water velocity, air-bubble flow rate, and cooled-plate temperature. The shape of freezing layer, freezing rate and salinity of frozen layer were observed and measured. It was found that the experimental parameters gave a great influence on the freezing rate and the salinity of the frozen layer.

  • PDF

An Experimental Study on the Sea Water Freezing Behavior Around Parallel Cooled Plate in the Rectangular Duct (평행냉각평판을 갖는 구형용기내에서의 해수동결거동에 관한 연구)

  • Park, D.S.;Park, S.K.;Kim, M.H.;Yoon, S.H.;Oh, C.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.249-257
    • /
    • 2001
  • This study was experimentally performed to investigate sea water freezing behavior along parallel cooled plate with bubbly flow. The experiments were carried out for a variety of parameter, such as sea water velocity, air-bubble flow rate, and cooled-plate temperature. The shape of freezing layer, freezing rate and salinity of frozen layer were observed and measured. It was found that the experimental parameters gave a great influence on the freezing rate and the salinity of the frozen layer.

  • PDF