• 제목/요약/키워드: freezing air temperature

검색결과 159건 처리시간 0.03초

장방형내 함수 다공성 물질의 동결거동에 관한 실험적 연구 (An Experimental study on the Freezing Phenomena of Saturated Porous Media in a Rectangular Cavity)

  • 김병철;김종일;김진흥
    • 설비공학논문집
    • /
    • 제3권5호
    • /
    • pp.386-394
    • /
    • 1991
  • Freezing of saturated porous media contained in a rectangular cavity has been studied experimentally. Water and different diameter glass beads consitituted the liquid and porous media. Solidification front shape, the effects of bead diameter and initial liquid temperature was investigated. When the hot wall temperature was below $4^{\circ}C$, the freezing rate was higher at the top than at the bottom due to the density inversion, but with increasing the hot wall temperature the freezing rate at the top was effected by the liquid temperature and was lower than at the bottom. With increasing the bead diameter, the difference of freezing rate between top and bottom was increased and depends on thermal conductivity. When the liquid temperature was low in the beginning, the freezing rate was high, but with increasing the time almost the same with those of high temperature liquid.

  • PDF

상변화물질(PCM)을 이용한 열교환기용 동파방지밸브에 관한 실험적 연구 (An Experimental Study on the Freezing Protection Valve Using Phase Change Material(PCM) for the Heat Exchanger)

  • 윤재호;김종하;정순영;양윤섭;김성현;송덕용
    • 한국태양에너지학회 논문집
    • /
    • 제32권6호
    • /
    • pp.127-133
    • /
    • 2012
  • This paper is an experimental study on the freezing protection valve used for solar water heating, air-conditioning systems, and plumbing systems. When the phase change occurs from liquid to solid, most of the substances except water volumetrically shrink. And referred to as PCM(Phase Change Material) a substance with such properties, the phase change temperature varies depending on the material. To prevent the freezing of the plumbing system, such as air-conditioning system in the winter season, we developed a several types of freezing protection valve using PCM whose freezing temperature are $2-4^{\circ}C$. The working principle of the freezing protection valve is that the fluid inside the pipe is released to prevent the system-collapse when fluid temperature reaches the freezing temperature of the PCM. And then the valve is closed and returned to the original position automatically when the temperature of the operating fluid rises. In this paper, the operating temperatures, discharge flow rate and the response characteristics of the valve during the operation are tested and investigated. From the results of this research the freezing protection valves employing PCM are expected to be commercialized in the near future.

Evaluation of the Relationship between Freezing Rate and Quality Characteristics to Establish a New Standard for the Rapid Freezing of Pork

  • Yun, Young-Chan;Kim, Honggyun;Ramachandraiah, Karna;Hong, Geun-Pyo
    • 한국축산식품학회지
    • /
    • 제41권6호
    • /
    • pp.1012-1021
    • /
    • 2021
  • This study evaluated the effect of freezing rate on the quality characteristics of pork loin to establish an objective standard for rapid freezing. To generate various freezing rates, three air flow rates (0, 1.5, and 3.0 m/s) were applied under three freezing temperatures (-20℃, -30℃, and -40℃). Based on the results, freezing rates ranged from 0.26-1.42 cm/h and were graded by three categories, i.e, slow (category I, >0.4 cm/h), intermediate (category II, 0.6-0.7 cm/h) and rapid freezing (category III, >0.96 cm/h). Both temperature and the air flow rate influenced the freezing rate, and the freezing rate affected the ice crystal size and shear force in pork loin. However, the air flow rate did not affect thawing loss, drip loss or the color of pork loins. In the comparison of freezing rates, pork belonging to category II did not show a clear difference in quality parameters from pork in category I. Furthermore, pork in category III showed fresh meat-like qualities, and the quality characteristics were clearly distinct from those of category I. Although the current standard for rapid freezing rate is 0.5 cm/h, this study suggested that 0.96 cm/h is the lowest freezing rate for achieving meat quality distinguishable from that achieved with conventional freezing, and further increasing the freezing rate did not provide advantages from an energy consumption perspective.

Von-Kármán 회전 유동 하에서의 물의 결빙 (Freezing of Water in Von-Kármán Swirling Flow)

  • 유주식
    • 설비공학논문집
    • /
    • 제8권3호
    • /
    • pp.413-422
    • /
    • 1996
  • Freezing of water in von-$K{\acute{a}}rm{\acute{a}}n$ swirling flow is considered. The transient behavior of the temperature distribution in both solid and liquid phases and freezing rate are determined. The fluid flow induced by the rotation of solid strongly inhibits the freezing process. The thickness of frozen layer is inversely proportional to the square root of the angular velocity of solid. As the angular velocity or initial liquid temperature becomes larger, the freezing process is more strongly inhibited by the fluid flow. When phase change is present, the transient heat transfer rate is greater than the case with no phase change.

  • PDF

냉동 방법에 따른 떡의 품질특성 변화 (Quality Characteristics of Korean Rice Cake by Freezing Methods)

  • 이혜진;구수경;최희돈;박종대;성정민;김영붕;최현욱;최윤상
    • 한국식품조리과학회지
    • /
    • 제33권2호
    • /
    • pp.148-154
    • /
    • 2017
  • Purpose: Frozen Korean traditional rice cakes (Sulgitteok and Garaetteok) were evaluated different conditions ($-20^{\circ}C$ and $-10^{\circ}C$) freezing (magnetic resonance quick freezing and air blast freezing) to study differences in quality characteristics. Methods: Experiments analyze Korean rice cakes for water content, water activity, color, textural properties, and sensory characteristics. Results: Moisture content showed high value at $-20^{\circ}C$ freezing regardless of freezing method. Water activity was higher at $-20^{\circ}C$ than $-10^{\circ}C$, and water activity higher magnetic resonance quick freezing than air blast freezing. The lightness values were higher $-20^{\circ}C$ freezing temperature compare to $-10^{\circ}C$ freezing temperature. Hardness and chewiness were the lowest $-20^{\circ}C$ magnetic resonance quick freezing. sensory evaluation both Sulgitteok and Garaetteok showed better overall acceptability at $-20^{\circ}C$ magnetic resonance quick freezing. Conclusion: Therefore, the $-20^{\circ}C$ magnetic resonance quick freezing method resulted in favorable textural properties and sensory characteristics.

동결피해 후의 수확시기가 사과 '후지' 품종의 저장 중 과실품질에 미치는 영향 (Influence of Harvest Time after Freezing Damage on Fruit Quality during Storage of 'Fuji' Apples)

  • 권헌중;이상규;박무용;송양익;남종철;사공동훈
    • 원예과학기술지
    • /
    • 제28권6호
    • /
    • pp.990-995
    • /
    • 2010
  • 본 시험은 이상저온($-3.5^{\circ}C$ 이하에서 7시간 지속)에 의해 수체 상에서 동결된 사과 '후지' 과실들의 수확시기에 따른 품질차이를 비교하고자 실시하였다. 수확 시기는 동결피해 1일 전, 동결피해 2일 후, 동결피해 6일 후였다. 시험에 조사된 과실들의 수확시 가용성 고형물 함량은 $14^{\circ}Bx$ 이상이었다. 동결피해 후 수확한 과실의 수확 시 경도 및 산 함량은 동결피해 전에 수확한 과실보다 낮았다. 저온저장 중의 에틸렌 발생량은 동결피해 후 수확한 과실이 동결피해 전에 수확한 과실보다 높았다. 동결피해 후 수확한 과실의 저온 저장 동안의 품질저하는 동결피해 전에 수확한 과실보다 심하였다. 동결피해 후에 수확한 과실의 저온저장 출고 후 실온 1주일째의 품질 저하는 동결피해 전에 수확한 과실보다 더 심하였다. 동결피해 후에 수확한 시험구들간의 비교에서는 저온저장 8주까지 동결피해 6일 후에 수확한 시험구의 에틸렌 발생량 및 과실품질 저하가 동결피해 2일 후에 수확한 시험구보다 낮았으나, 이러한 차이는 저온저장 8주 이후로는 없었다. 과육 갈변증상 발생률은 $-3.5^{\circ}C$ 이하에서 7시간 동결될 경우 영향을 받지 않은 것으로 나타났다.

경사냉각면에 따른 함수정방형내의 동결현상에 관한 실험적 연구 (An experimental study on freezing phenomena of water saturated square cavity with inclined cold surface)

  • 이춘희;김종준;김병철
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.435-445
    • /
    • 1997
  • It was studied the phenomena of transient freezing of an inclined water-saturated enclosure. One side of the test section was cooled and the other sides were insulated. The effects of the initial temperature, the inclination angle on the temperature field and the shape of the ice-water interface were observed. In the beginning of freezing, with increasing the inclination angle the freezing rate was increased and in the stable density layer centered $4^{\circ}C$, the freezing was fast as the convective fluid flow became small. When the initial temperature was above the $4^{\circ}C$, the frozen thickness in the upper part of inclined surface was thinner than that in the lower part, but with time the frozen thickness of upper part was thicker than that of lower part, below the $4^{\circ}C$, the frozen thickness in the upper part was thicker than that of lower part from the begining, and above the $8^{\circ}C$ in the beginning upper part was thinner with concave, but with time thicker the upper part, vanishing concave.

  • PDF

다공성 물질이 충전된 정방형 밀폐용기 내에서 수용성 혼합용액의 동결거동에 관한 실험적 연구 (Experimental Study on the freezing of Aqueous Binary Solution Saturated Packed bed in a Square Cavity)

  • 최주열;김병철
    • 설비공학논문집
    • /
    • 제4권3호
    • /
    • pp.175-182
    • /
    • 1992
  • Freezing of the binary solution ($H_2O-NaCl$) saturating a packed bed of spheres is investigated experimentally. The system is cooled through its top surface, and the bottom is maintained at a temperature above the liquidus. Experiments are performed on the hypolutectic side, and the cold wall temperature is lower than the eutectic point. The effects of initial mixture concentration, superheat and glass bead diameter on temperature and concentration distributions are investigated. Supercooling was observed only at early times of the freezing process for experiments with 5% initial salt concentration. Flow visualization experiments and mushy-liquid interface position observations revealed natural convection in the liquid region. Remelting phenomena was not observed at both the solid-mushy and mushy-liquid interfaces.

  • PDF

선박용 제빙장치의 개발을 위한 해수동결거동에 관한 연구 (A study on sea-water freezing behavior for ice maker for fishing boat)

  • 최영규;김정식;김경근;오철
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.233-238
    • /
    • 2005
  • According to change of flow around a circular tube for freezing, measured a variety of salinity of frozen layer. This study was experimentally performed to investigate freezing behavior of sea water along a vertical cooled a circular tube with bubbly flow. The experiments were carried out for a variety of parameter, such as air-bubble method, cooled -tube temperature and air-flow rate. It was found that the experimental parameters gave a great influence on the freezing rate and the salinity of the frozen layer.

  • PDF

열분석을 통한 열전용 보일러동 실내배관의 동파 가능성 예측 (Prediction of Possibility of Indoor Pipe Freezing in Heat Only Boiler Room through Thermal Analysis)

  • 임병익;정광섭;김영일
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권3호
    • /
    • pp.19-28
    • /
    • 2012
  • In a heat only boiler system of a steam power plant, outdoor air required for combustion is made to pass through indoor space for increasing the boiler efficiency. Due to heat generated by various equipments, temperature of the air that enters the boiler will increase resulting in combustion efficiency. If the outdoor air temperature is low, however, this will cause freezing and bursting of pipes which are filled with water. It is especially fatal to small diameter pipes and pipes connected to measuring instruments. The purpose of this study is find operation and outdoor conditions where this phenomena can happen and also establish preventive measures to avoid this problem.