• Title/Summary/Keyword: freezing air temperature

Search Result 159, Processing Time 0.022 seconds

The statistical factors affecting the freezing of the road pavement (도로포장체의 동결에 영향을 미치는 통계적 요인)

  • Kim, Hyun-Ji;Lee, Jea-Young;Kim, Byung-Doo;Cho, Gyu-Tae
    • Journal of the Korean Data and Information Science Society
    • /
    • v.27 no.1
    • /
    • pp.67-74
    • /
    • 2016
  • Due to the character of the climate of Korea, the pavement of a road is Influenced by freezing in winter season and thawing in thawing season. In the last few years, several articles have been devoted to the study to minimize the damage of freezing and thawing action. The purpose of this paper is to identify appropriacy of factors that influence road pavement thickness. We conduct the decision tree analysis on the field data of road pavement. The target variable is 'Frost penetration'. This value was calculated from the temperature data. The input variables are 'Region', 'Type of road pavement', 'Anti-frost layer', 'Month' and 'Air temperature'. The region was divided into 9 regions by freezing index $350{\sim}450^{\circ}C{\cdot}day$, $450{\sim}550^{\circ}C{\cdot}day$, $550{\sim}650^{\circ}C{\cdot}day$. The type of road pavement has three-section such as area of cutting, boundary area of cutting and bankin, lower area of banking. As the result, the variables that influence 'Frost penetration' are Month, followed by anti-frost layer, air temperature and region.

Performance Simulation of a R744-R717 Cascade Refrigeration System According to Operating Conditions (R744-R717 캐스케이드 냉동시스템에서 운전조건 변화에 따른 성능 해석)

  • Ryu, Jiho;Cho, Honghyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.497-505
    • /
    • 2015
  • The evaporating temperature range required for the low temperature freezing system is from $-50^{\circ}C$ to $-30^{\circ}C$. Since it is difficult to keep the required capacity in a cabinet, it is advantageous to design the system using a cascade refrigeration system. Use of carbon dioxide and ammonia would be advantageous since ammonia is an environment-friendly working fluid and has a high capacity for performance improvement. To investigate the performance characteristics of the R744-R717 cascade refrigeration system, a theoretical model was developed and performance was analyzed according to cascade heat exchanger operating temperature. The optimal cascade R744 condensing temperature was $-5^{\circ}C$, and maximum COP was 1.13 when the temperature difference of the cascade heat exchanger was $5^{\circ}C$. In addition, the total system COP increased by 1.17 when the cascade temperature gap was $3^{\circ}C$ at the middle temperature of $-7.5^{\circ}C$.

An Experimental Study on the Low-Temperature Behavior of Stratified Fluids in the Square Cavity (저온에서 정방형 공간내 성층화된 유체의 열적거동에 관한 실험적 연구)

  • 강한용;이동석;김병철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.4
    • /
    • pp.381-387
    • /
    • 2000
  • An experimental study on the stratified fluids was carried out to investigate the flow characteristics, heat transfer through the interface of fluids, and the applications of thermal behaviors in the square cavity. The same volume of water and silicon oil was filled in it. The experiments were performed with the variations of initial temperatures and cooling surface temperatures. And the effect of vertical or horizontal cooling surface positions in the square cavity was investigated. When the cooling surface temperatures were $-4^{\circ}C$ , the supercooling phenomena were observed for both cases of cooling surface positions in the full region regardless of the initial temperature of fluid. In the square cavity with horizontal cooling surfaces, the lower the initial temperatures were, the longer the supercooling durations were, and with vertical cooling surface the lower the initial temperatures were, the shorter the supercooling durations were.

  • PDF

Freeze Protection for Passive Solar Water Heating System (자연순환형 태양열온수기 동파방지기술)

  • Kim, Jong-Hyun;Hong, Hi-Ki;Chung, Jae-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.5
    • /
    • pp.327-333
    • /
    • 2011
  • In the present work, a new freeze protection method has been proposed for a natural circulation system of solar water heater. Though electrothermal wire is popularly used for the purpose, there are freezing troubles by wire cut-off and shortage of excessive electric power consumption. In the experimental device, hot water in storage tank was used to heat the outlet pipe from the tank if the pipe surface temperature falls lower than a set point. The cold water pipe to the storage tank was installed to directly contact the hot water pipe surface temperature rose by transferred heat.

An Experimental Study on the Strength Properties of Concrete for Curing Method at Early Age and kinds of Admixture in Winter (동절기 초기양생방법 및 혼화제 종류에 따른 콘크리트의 강도발현특성에 관한 실험적 연구)

  • 최성우;이민호;반성수;최봉주;유득현
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.183-188
    • /
    • 2002
  • When Concrete work during winter is placed, it has anxiety that concrete freeze at low temperature. As concrete's freezing cause reduction of durability, it is necessary for mixing to pay attention to Air content and W/C ratios. Accordingly, in this study, we set up three series and evaluate a frost-resistance of concrete with admixture, like fly-ash and blast-furnace slag, for early curing method and types of chemical admixture..The study is composed as; I series : Analysis for early curing method and types of chemical admixture in laboratory II series : Analysis for early curing method and types of chemical admixture in batcher plant and measured concrete' temperature. The result of this study, it was more effective the use of super-plasticizers than air entraining agent.

  • PDF

Cold Thermal Energy Storage Characteristics of Spherical PCM Capsule (상변화물질을 충진한 구형 캡슐의 축냉 특성)

  • Yun, Hong-Sun;Kwon, Jin-Kyung;Jeong, Hoon;Lee, Hyun-Dong;Kim, Young-Geon
    • Journal of Biosystems Engineering
    • /
    • v.33 no.5
    • /
    • pp.303-308
    • /
    • 2008
  • The freezing characteristics of two kinds of phase change materials (PCM) encapsulated in a spherical container were investigated with various cooling air temperatures and velocities. The super cooling and solidification time of PCM were highly affected by cooling air temperature and velocity. The experimental equations are derived to express total solidification time of the PCM in terms of Nusselt number and dimensionless temperature.

Development of Bin Weather Data for Simplified Energy Calculations (간역열부하계산용(簡易熱負荷計算用) Bin기상(氣象)데이터)

  • Kim, Doo Chun;Choi, Jin Hee
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.1
    • /
    • pp.28-43
    • /
    • 1988
  • The purpose of this research is to produce bin weather data for Seoul from Standard Weather Data. The intended use of these data is for input to recently developed models for simplified energy calculations and for generating variable-base degree-day information. The data produced under this study include $3^{\circ}C$ bin data covering the full range of dry-bulb temperatures with mean coincident wet-bulb and daytime coincident solar radiation, wet-bulb bins down to freezing temperature, wind speed bins with prevailing directions, and heating and cooling degree hours to nine different temperature bases. All of these data are tabulated in six separate time periods and total daily categories for monthly and annual periods.

  • PDF

Experimental Study for Development of Air Eject Defrost Equipment (공기분사식 제상장치 개발에 관한 실험적 연구)

  • Han, In-Geun;Kim, Chang-Yeong;Kim, Jae-Dol;Yun, Jeong-In
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.3
    • /
    • pp.277-284
    • /
    • 2001
  • One of the problems in a refrigerator operation is the frost formation on a cold surface of the evaporator. The frost layer is formed by the sublimation of water vapor when the surface temperature is below the freezing point. This frost layer is usually porous and formed on the cold surface of the evaporator. The frost layer on the surface of a evaporator will make side effect such as thermal resistance. However, these important factors have not been used in determining the defrosting period. Therefore, the proper defrosting operation period based on the new defrosting method is very important, and make a comparison between conventional method like electric defrost and new method in compression work, evaporation pressure, evaporation temperature.

A theoretical analysis on the inviscid stagnation-flow solidification problem (비점성 정체 유동 응고 문제에 대한 이론적 해석)

  • 유주식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.1
    • /
    • pp.1-11
    • /
    • 2000
  • This study investigates the problem of phase change from liquid to solid in the inviscid stagnation flow. The solution of dimensionless governing equations is determined by the three dimensionless parameters of (temperature ratio/conductivity ratio), Stefan number, and diffusi-vity ratio. The solution at the initial stage of freezing is obtained by expanding it in powers of time, and the final equilibrium state is determined from the steady-state governing equations. The equilibrium state is dependent on (temperature ratio/conductivity ratio), but is independent of Stefan number and diffusivity ratio. The effect of fluid flow on the pure conduction problem can be clearly seen from the solution of the initial stage and the final equilibrium state, and the characteristics of the solidification process for all the dimensionless parameters are elucidated.

  • PDF

Fruit Quality and Storability by Harvest Time at 'Fuji'/M.9 Apple Orchard Located in the Area with a High Air Temperature during the Fall Season (가을철 기온이 높은 지역에 위치한 '후지'/M.9 사과원의 수확시기에 따른 과실품질과 저장성)

  • Sagong, Dong-Hoon;Kweon, Hun-Joong;Song, Yang-Yik;Park, Moo-Yong;Kang, Seok-Beom;Yoon, Tae-Myung
    • Horticultural Science & Technology
    • /
    • v.31 no.4
    • /
    • pp.437-446
    • /
    • 2013
  • This study was conducted for three years (2007, 2009, and 2010) to investigate the changes in fruit quality during maturation, and the quality and storage ability of fruits harvested at different times of 'Fuji' apple in Daegu region with a high air temperature during the fall season. Changes in apple fruit quality during the maturation period were investigated from 120-135 days to 183-198 days after full bloom. In comparing quality and storage ability of fruits harvested at different times, fruits harvested more than 180 days after full bloom were used. During the maturation period, poor coloring was the problem for 'Fuji' apple in Daegu region by the high air temperature about $20^{\circ}C$. In comparing quality of fruits harvested at different times, the soluble solid contents and hunter a value were increased by the extended harvest time. Fruit weight during harvest was not affected by different harvest time, while the fruit firmness and titratable acidity during harvest were decreased critically when the freezing damage happened. Ethylene production, fruit firmness, and titratable acidity during cold storage for twenty weeks did not differ according to the different harvest time. Soluble solid contents of fruits harvested at 216 days after full bloom in 2009 were similar at the time of harvest and cold storage. For fruits harvested at 201 days after full bloom, soluble solid content during cold storage was higher than during harvest time. However fruit firmness, soluble solid content, and titratable acidity after cold storage of fruit harvested after freezing damage was lower than those of the fruit harvested before freezing damage. The results show that the extended harvest time of 'Fuji' apples about 2-4 weeks from 180-200 days after full bloom in area with above-air temperature during fall season was seemed to be beneficial to enhancing soluble solid contents and fruit red color, but harvesting after the middle of November was dangerous because minimum air temperature began to fall under $-3.0^{\circ}C$.