• Title/Summary/Keyword: freeze-thaw environment

Search Result 43, Processing Time 0.022 seconds

Polylactic Acid Coating Affects the Ring Crush Strength of Linerboards

  • Lee, Jun-Ho;Rhim, Jong-Whan
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.38 no.5 s.118
    • /
    • pp.54-59
    • /
    • 2006
  • Paperboards used for linerboard of corrugated fiberboard box were coated with different concentrations of polylactic acid (PLA) solution and the effects of harsh environmental conditions such as high humidity and temperature (96% RH at $30^{\circ}C$ for up to 5 days), and freeze-thaw ($-20^{\circ}C$ for a day and then thaw at room temperature for 30 min) conditions on the ring crush (RC) strength of the boards were investigated. One to five percent PLA solutions were coated onto SC manila linerboard ($20{\times}27cm$) using a No. 20 wire bar coater and the ring crush strength was measured using a computer-controlled Advanced Universal Testing System in accordance with TAPPI Test Method T 822 om-93. The RC strength increased significantly when the concentration of coating solution increased and appreciable changes were found when the concentration increased from 0 to 2% (P<0.05). Similar pattern of results was found after 5-day storage at $30^{\circ}C$ and 96% RH. Although such highly humid condition increased moisture content in the samples up to 3.95 from 0.97 times, the RC strength decreased in the range from 29.9 to 48.5%. The freeze-thaw treatment increased the moisture content only up to 1.27% and the reduction in the RC strength ranged from 21.1 to 28.1 %. The results were promising: the samples coated with 5% PLA solution showed 29.9% reduction in the RC strength while that of control was 48.5% during highly humid condition stated above.

A Study on Comparison of Phycocyanin Extraction Methods for Hyperspectral Remote Sensing of Cyanobacteria in Turbid Inland Waters (국내 담수역 남조류 원격탐사를 위한 피코시아닌 추출법 비교 연구)

  • Ha, Rim;Shin, Hyunjoo;Nam, Gibeom;Park, Sanghyun;Kang, Taegu;Song, Hyunoh;Lee, Hyuk
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.520-527
    • /
    • 2016
  • Phycocyanin (PC) is one of the water-soluble accessory pigments of cyanobacteria species, and its concentration is used to estimate the presence and relative abundance of cyanobacteria. In laboratory experiments, PC content of field data were determined using Sarada's freeze-thaw method in algal bloom season. The effectiveness of three selected extraction methods (repeated freeze-thaw method, homogenization, power control) for PC were determined. The extraction efficiency of phycocyanin was the highest (of the methods compared) when a single freezing-thawing cycle was followed by pre-sonication. Applying this optimized method to surface water of Korean inland waters, the average concentration distribution was estimated at $2.9{\sim}51.9mg/m^3$. It has been shown that the optimized pre-sonication method is suitable to measure cyanobacteria PC content for the characterization of inland waters. The approach and results of this study indicates the potential of effective methods for remote monitoring and management of water quality in turbid inland waters using hyperspectral remote sensing.

A Study of Landfill Coyer Liners by Freezing/Thawing (동결/융해에 따른 폐기물 매립지 복토층 연구)

  • Jai-Young Lee
    • Journal of Korea Soil Environment Society
    • /
    • v.1 no.1
    • /
    • pp.103-109
    • /
    • 1996
  • The cover liners at municipal and hazardous waste landfill is not emphasized as much as the bottom liners. However, one of the most effective reason of landfill destroy is the cover liner failure. The cover system at municipal and hazardous waste landfill, 1 perform the following functions, at minimum: promote surface runoff, impede infiltration, protect settlement in the landfill, and provide a buffer from surface exposure of the waste. This research was to expand the existing knowledge base of landfill cover liner behavior during period of freeze/thaw Also, the great Lysimeter was built in the laboratory to provide as much as same condition with the field and three designs were simulated by actual cover materials. The result of simulation indicated the clay was effected by freezing/thawing. The degradation of cover liners in the frost penetration affects the physical, engineering properties of clay. these factors may consider to design and construct of the landfill. This paper provides the description of testing cover liners, experimental results and a discussion of the results of the simulation.

  • PDF

A Study on the Durability of Glass Fiber Reinforced Plastics Rebars (GFRP 리바의 내구성에 관한 연구)

  • Moon, C.K.;Kim, Y.H.;Park, Y.H.
    • Journal of Power System Engineering
    • /
    • v.9 no.2
    • /
    • pp.50-56
    • /
    • 2005
  • The mechanical properties of glass fiber reinforced polymer reinforcing bars(rebar) in various environment conditions such as moisture, chloride, alkali and freeze-thaw actions at temperature ranging from room temperature($25^{\circ}C$) to high temperature of up to $80^{\circ}C$ have been studied. The test results indicated that tensile strength and interfacial shear strength of GFRP bar were decreased with the increasing of temperature and holding time of each environment condition. The degradation in alkali environment. was more serious than those in the other environments.

  • PDF

Evaluation of Freeze-Thaw Damage on Concrete Using Nonlinear Ultrasound (초음파의 비선형 특성을 이용한 콘크리트 동결융해 손상 평가)

  • Choi, Ha-Jin;Kim, Ryul-Ri;Lee, Jong-Suk;Min, Ji-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.4
    • /
    • pp.56-64
    • /
    • 2021
  • Leakage due to deterioration and damage is one of the major causes of volume change by freezing and thawing, and it leads micro-cracking and surface scaling in concrete structures. The deterioration of damaged concrete accelerates with the chloride attack. Thus, in the detailed guidelines for facility performance evaluation (2020), the quality of cover concrete and the freeze-thaw (FT) repetition cycle were newly suggested for concrete durability assessment. The quality of cover concrete should be evaluated by the rebound hammer test and the FT repetition cycle should be also considered in the deterioration environmental assessment. This study suggested the application of fast dynamic based nonlinear ultrasound method to monitor initial micro-scale damage under freezing and thawing environment. Concrete specimens were fabricated with different water-cement ratios (40%, 60%) and air contents (1.5% and 3.0%). The compressive strength, rebound number, relative dynamic modulus, and nonlinear ultrasound were measured with different FT cycles. The scanning electron microscopy was also performed to investigate the micro-scale FT damage. As a result, both the rebound number and the relative dynamic modulus had difficulty to detect early damage but the proposed method showed a potential to detect initial micro-scale damage and predict the FT resistance performance of concrete.

Evaluation of Maintenance Coating Materials for Steel Bridges

  • Lee, Chan-Young;Cheong, Haimoon;Kim, Ok-Sun
    • Corrosion Science and Technology
    • /
    • v.4 no.5
    • /
    • pp.207-210
    • /
    • 2005
  • Coating performance of various coating systems including chlorinated rubber and epoxy/urethane used most for steel structures of highway in Korea, was evaluated by exposing test specimen to complex deterioration factors such as ultraviolet ray, moisture, freeze-thaw cycle and salt. Deteriorated specimens were evaluated by chalking and rust grades according to ASTM, and measurement of color differences and adhesion. In overall coating performances such as corrosion resistance, photochemical stability, and adhesion, ceramic/ urethane, moisture-curable urethane/ urethane, etc. were superior. As for other coating materials tested in this study, superior materials against certain deterioration factors may be inferior against other factors. Accordingly, in order to select suitable maintenance coating materials for the use, it is thought that investigation of suitability through experiment should precede selection of materials, especially for unusual coatings or paints.

Freeze and Thaw Durability of Concrete Using Recycled Aggregates (재생골재를 사용한 콘크리트의 동결융해 저항성)

  • 문대중;팽우선;문한영
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.3
    • /
    • pp.307-314
    • /
    • 2002
  • Utilization of demolished-concrete as recycled aggregate has been researched for the purpose of substituting for insufficient natural aggregate, saving resources and protecting environment. There, however, are some Problems not only the large difference of dualities in recycled aggregates but also a little deterioration of mechanical properties in recycled aggregate concrete in comparison with that of natural aggregate concrete. In this study, the test results of freez and thaw durability of concrete with demolished-concrete recycled aggregate(DRA) arc as follows. Improvement of crushing process is an important assignment because that adhered mortar on source-concrete recycled aggregate(SRA) and DRA highly affects thc qualifies of recycled aggregate. The compressive strength of recycled aggregate concrete was not highly different in comparison with that of control concrete. But the resistance to penetration of Cl in recycled aggregate concrete was shown smaller than that of control concrete because of adhered mortar on recycled aggregate. The resistance to frcezing and thawing of recycled aggregate concrete was highly different due to adhered mortar on recycled aggregate, and durability factor of concrete with NA-SRA and DRA was more decreased than that of control concrete. On the other hand, durability factor of concrete with AA-SRA was larger than that of control concrete. It, therefore, is necessarily required that recycled aggregate including adequate entrained air should be used for satisfying the freez and thaw durability of recycled aggregate concrete.

Evaluation of Freezing-thawing Resistance by Sea water with Variation of micropores of slag concrete (슬래그 콘크리트의 미세 공극구조 변화에 따른 해수 동결융해 저항성능 평가)

  • Song, Gwon-Yong;Kim, Gyu-Yong;Lee, Bo-Kyeong;Kim, Rae-Hwan;Kim, Hong-Seop;Han, Sang-Hyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.129-130
    • /
    • 2014
  • In the case of concrete structures which have been recently exposed to the marine environment, durability is greatly reduced by the freezing-thawing action. When it is used by appropriately replacing the ground granulated blast-furnace slag(GGBS) that is a industrial by-product, the concrete structure of marine environment is known to have a durability to freezing-thawing resistance. In this experiment, micropore in accordance with a replacement ratio of GGBS was confirmed to show different results respectively. The freeze-thaw resistance was showed different aspects respectively because it is different the amount of water in the pore due to the difference of micropore. Therefore, in this study, the freezing-thawing resistance of sea water by variation of micropores of slag concrete had been evaluated.

  • PDF

Engineering Performance and Applicability of Eco-Friendly Concrete for Artificial Reefs Using Electric Arc Furnace Slags (전기로 슬래그를 활용한 인공리프용 친환경콘크리트의 공학적 성능 및 적용성)

  • Jo, Young-Jin;Choi, Se-Hyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.3
    • /
    • pp.533-544
    • /
    • 2015
  • Unlike the concrete structure built on land, that exposed to the marine environment is greatly degraded in durability due to the exposure to not only the physical action caused by sea wind, tide, and wave, but also the harsh conditions, including the chemical erosion and freeze-thaw which result from $SO_4{^{2-}}$, $Cl^-$ and $Mg^{2+}$ ions in seawater. In the process of the large scaled construction of submerged concrete structures, of course environmental hazardous substance, such as alkaline (pH) and heavy metals, may be leached. Thus, this issue needs to be adequately reviewed and studied. Therefore, this study attempted to develop a CSA (Calcium Sulfo Aluminate) activator using electric arc furnace reducing slags, as well as the eco-friendly concrete for artificial reefs using electric arc furnace oxidizing slag as aggregate for concrete. The strength properties of the eco-friendly concrete exposed to the marine environment were lower than those of the normal concrete by curing 28 days. This suggest that additional studies are needed to improve the early strength of the eco-friendly concrete. With respect to seawater resistance of the eco-friendly concrete, the average strength loss against 1 year of curing days reached 8-9%. the eco-friendly concrete using high volume of ground granulated blast furnace slags and high specific gravity of electronic arc furnace oxidizing slag demonstrated the sufficient usability as a freeze-thaw resistant material. With respect to heavy metal leaching properties of the eco-friendly concrete, heavy metal substances were immobilized by chemical bonding in the curing process through the hydration of concrete. Thus, heavy metal substances were neither identified at or below environmental hazard criteria nor detected, suggesting that the eco-friendly concrete is safe in terms of leaching of hazardous substances.

A Study on Stability evaluation in the freezing/thawing process of urine specimen analytes (소변 검체 분석물질의 냉/해동 과정 안정성 평가 연구)

  • Kim, Min Kyung;Kim, Sung Wook;Hwang, You Seong;Oh, Eunha
    • Journal of the Korean Applied Science and Technology
    • /
    • v.39 no.1
    • /
    • pp.52-62
    • /
    • 2022
  • The purpose of this study was to find a way to improve the stability and quality of urinalysis by checking the changes in the measurement values of representative clinical chemistry test items according to the repeated freezing and thawing before the urine test and the thawing process. All subjects were 10 healthy males, and the freeze and thaw stability test was performed using their urine samples. In the case of micro-albumin and amylase, there was no statistical significance at 37℃ with time, but at 42℃ and 60℃, there was a statistically significant change in the results with time. There were statistically significant changes in BUN, creatinine, uric acid, and glucose. As a result of long-term stability, after 7 days, glucose mutation increased and amylase decreased at 60℃. In the case of glucose and amylase, there was a statistically significant change in the results over time. To obtain accurate test results, accurate standardization of urinalysis including appropriate collection, storage, and storage methods of urine samples is required and systematic study of conditions for securing stability for each biomaterial is required.