• 제목/요약/키워드: free gas

검색결과 1,033건 처리시간 0.03초

난류 효과를 포함한 다중 충돌 제트의 냉각 특성에 대한 수치적 연구 (NUMERICAL STUDY ON COOLING CHARACTERISTICS OF MULTIPLE IMPINGING JETS INCLUDING THE EFFECT OF TURBULENCE)

  • 전진호;손기헌
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 춘계학술대회논문집
    • /
    • pp.321-328
    • /
    • 2009
  • Free surface impinging jet on a moving plate, which is applicable to cooling of hot metals in a steel-making process, is investigated numerically by solving the Navier-Stokes equations in the liquid and gas phases. The free surface of liquid-gas interface is tracked by a level-set method which is improved by incorporating the ghost fluid approach based on a sharp-interface representation. The method is further improved by employing a nonequilibrium $\kappa-\varepsilon$ turbulence model including the effect of low Reynolds number. The computations are made to investigate the effects of the nozzle pitch, moving velocity of plate and jet velocity on the interfacial motion and the associated flow and temperature fields.

  • PDF

Steady-State and Transient Performance Simulation of a Turboshaft Engine with a Free Power Turbine

  • King, Chang-Duk;Chung, Suk-Choo
    • Journal of Mechanical Science and Technology
    • /
    • 제14권11호
    • /
    • pp.1296-1304
    • /
    • 2000
  • A program of steady-state and transient performance analysis for a 200kW-class small turboshaft engine with free power turbine was developed. An existing turbojet engine was used for the gas generator of the developed turboshaft engine, which was modified to satisfy performance requirements of this turboshaft engine. To verify the accuracy of steady-state performance program for this engine: the program was applied to the gas turbine test unit of the same type, and the analysis results were compared with experimental results. The developed transient performance analysis program using the CMF (Constant Mass Flow) method was utilized to analyze the cases of step increase and ramp increase of the fuel.

  • PDF

극저온 자화 유도 결합 플라즈마를 이용한 Platinum 식각에 관한 연구 (A study on platinum dry etching using a cryogenic magnetized inductively coupled plasma)

  • 김진성;김정훈;김윤택;황기웅;주정훈;김진웅
    • 한국진공학회지
    • /
    • 제8권4A호
    • /
    • pp.476-481
    • /
    • 1999
  • Characteristics of platinum dry etching were investigated in a cryogenic magnetized inductively coupled plasma (MICP). The problem with platinum etching is the redeposition of sputtered platinum on the sidewall. Because of the redeposits on the sidewall, the etching of patterned platinum structure produces feature sizes that exceed the original dimension of the PR size and the etch profile has needle-like shape [1]. The main object of this study was to investigate a new process technology for fence-free Pt etching As bias voltage increased, the height of fence was reduced. In cryogenic etching, the height of fence was reduced to 20% at-$190^{\circ}C$ compared with that of room temperature, however the etch profile was not still fence-free. In Ar/$SF_6$ Plasma, fence-free Pt etching was possible. As the ratio of $SF_6$ gas flow is more than 14% of total gas flow, the etch profile had no fence. Chemical reaction seemed to take place in the etch process.

  • PDF

자연급기 무가습 연료전지의 Dry-out조건 (Dry-out conditions of free-breathing PEMFC with dry $H_2$ gas)

  • 박상균
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.225-230
    • /
    • 2006
  • This study investigates drying condition when a small fan is added to a operating the free-breathing proton exchange membrane fuel cells (PEMFCs) with dry $H_2$ and Air. Polarization tests were conducted on PEMFCs at cell temperatures between 30 and $50^{\circ}C$ under dry operation. In the results, the cell performance strongly depended on the cell temperature and the cathode gas stoichiometric flow rates. The cell performance increases as cell temperature decreases from 50 to $30^{\circ}C$. In the domain where the stoichiometry of air is quite large, reduction of the concentration overpotential compensated the increased internal resistance due to drying. The maximum performance was obtained at the small air flow rate beyond which flooding occurs. This indicates that the fan should be operated in the stoichiometry domain with a well designed cell structure to avoid flooding.

기체 Chromatograph를 이용한 체액내 Volatile Free Acid의 분석연구 (Volatile Free Acid Profiling of Body Fluids by Gas Chromatography)

  • 김경례;한미경
    • 약학회지
    • /
    • 제32권1호
    • /
    • pp.6-13
    • /
    • 1988
  • A gas chromatographic method is described for the determination of volatile free acids(VFAs) in body fluids. VFAs were trace enriched from body fluids by liquid-solid extraction using Chromosorb P as the solid sorbent and ether as the eluant. The enriched VFAs were injected in splitless injection mode onto a HP-20M fused silica capillary column. The flame ionization detector was used as the detector. The present method was applied to the profiling of VFAs in body fluids from patients suffering from the infectious disease, hepatitis. The VFAs concentrations were high in saliva of hepatitis patients and isobutyric acid detected in sera of hepatitis patients compared to healthy subjects.

  • PDF

가변 파장형 적외선 가스 센서에 의한 생체표지자 분석 (Analysis of biomarkers with tunable infrared gas sensors)

  • 이승환
    • 센서학회지
    • /
    • 제30권5호
    • /
    • pp.314-319
    • /
    • 2021
  • In this study, biomarkers were analyzed and segmented using tunable infrared gas sensors after performing the principal component analysis. The free spectral range of the device under test (DUT) was around 30 nm and DUT-5580 yielded the highest output voltage property among the others. The biomarkers (isoprophyl alcohol, ethanol, methanol, and acetone solutions) were sequentially mixed with deionized water and their mists were carried into the gas chamber using high-purity nitrogen gas. A total of 17 different mixed gases were tested with three tunable infrared gas sensors, namely DUT-3144, DUT-5580, and DUT-8010. DUT-8010 resolved the infrared absorption spectra of whole mixed gases. Based on the principal component analysis with each DUT and their combinations, each mixed gas and the trends in increasing gas concentration could be well analyzed when the contributions of the eigenvalues of the first and second were higher than 70% and 10%, respectively, and their sum was greater than 90%.

ICP 광원 시스템의 Ne:Xe 및 Ne:Ar 혼합가스의 전자온도 및 전자밀도 특성 (The Electron Temperature and Density Properties of Mixed Gases in ICP Lighting System : (Ne:Xe, Ne:Ar))

  • 이종찬;최용성;박대희;최기승
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권3호
    • /
    • pp.156-160
    • /
    • 2006
  • In whole world consciousness of environment maintenance have increased very quickly for the end of the 20th century. To use and disuse toxic substances have been controled at the field of industry. Also the field of lighting source belong to environmental control. And in the future the control will be strong. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem and root. In the mercury free lighting source system the Xe gas lamp is one type. And the Ne:Xe and Ne:Ar mixed gas lamp improve firing voltage of Xe gas lamp. Purpose of this study is to understand ideal mixing-ratio of Ne:Xe and Ne:Ar gas by electron temperature and electron density for mercury free lamp. Before ICP was designed, basic parameters of plasma, which are electron temperature and electron density, were measured and calculated by single-Langmuir probe. Property of electron temperature and electron density were confirmed by changing ratio of Ne:Xe and Ne:Ar.

LCD 배면광원용 무수은 형광램프의 전기.광학적 특성 (Electro-Optical Characterization of Hg-Free Fluorescent Lamps for LCD Backlight)

  • 이순석;임성규
    • 한국콘텐츠학회논문지
    • /
    • 제6권12호
    • /
    • pp.163-168
    • /
    • 2006
  • LCD의 배면광원으로 활용될 무수은 형광램프를 제작한 다음, 전기 광학적 특성을 평가하였다. PDP 형광체, nitro-cellulose 및 n-butyl acetate를 혼합하여 유리관 내부에 얼룩 없이 균일하게 코팅하였다. 또 $550^{\circ}C$에서 20 분 동안 소성하였고, 가스혼합장치를 이용하여 $10^{-6}$ torr까지 배기시킨 다음 방전가스를 주입하여 형광램프를 완성시켰다. 형광체 두께 및 유리관 직경 등을 변화시켜 제작, 평가한 결과 이들 변수들에 대하여 최적의 값을 찾아 낼 수 있었다. 또한 Ne+Xe 방전가스를 주입하여 제작된 형광램프에 75 kHz의 정현파 전압을 공급시킨 결과 휘도 $6,270cd/m^2$, 발광효율 13 lm/W를 얻었다.

  • PDF

헬륨 기체분류의 정상적 비정상적 거동에 관한 연구 (A Study on Steady and Unsteady Behavior of Helium Jet in the Stationary Atmosphere)

  • 김봉곤;서용권;하종률;권순석
    • 한국자동차공학회논문집
    • /
    • 제1권3호
    • /
    • pp.34-45
    • /
    • 1993
  • This study aims to analyze the mixing characteristics of hydrogen considered as a new fuel for internal combustion engines. As the physical property of helium gas is similar to that of hydrogen, helium gas was used in this study. To analyze the steady and unsteady behavior of jet, helium gas was injected into the stationary atmosphere at the normal temperature and pressure. Concentration of helium gas in the center of jet flow is in inverse proportion with axial distance from the nozzle tip. This agrees with the free jet theory of Schlichting. The relative equation for dimensionless concentration to radial/axial distance the axial distance of potential core region, the cone angle a of the jet flow and the relative equation for arriving distance of the front of jet flow to the lapse of time are obtained. But free jet theory of Schlichting in the dimensionless concentration is not in agreement with the present experimental results of the distance of the radial direction. It needs more study. When the arrival frequency of jet flow is used as a parameter, the transition area changing from unsteady flow area into steady flow area becomes gradually wider downstream, but its ratio for the whole unsteady flow area gradually decreases.

  • PDF

중공사막 접촉기를 이용한 암모니아 물질전달 모델링 (Modeling of Ammonia Mass Transfer Using a Hollow Fiber Membrane Contactor)

  • 오대양;정주영;최원호;박주양
    • 상하수도학회지
    • /
    • 제25권4호
    • /
    • pp.503-510
    • /
    • 2011
  • Ammonia in water which is toxic to human, its concentration is regulated below 0.5 mg/L in drinking water. Current study aimed to develop appropriate models for ammonia stripping using hollow fiber membrane contactor. Two different models were developed during the study. Model 1 was assumed only free ammonia ($NH_3$) transfer in stripping process, whereas the Model 2 was assumed with total ammonia ($NH_3+{NH_4}^+$) transfer. Ammonium chloride ($NH_4CI$), sodium hydroxide(NaOH) were used to make ammonia solution, which was concentration of 25 mg as N/L at a pH of 10.5. The experimental conditions were such that, the liquid flow was in tube-side in upward direction and t he gas flow was on shell-side in downward direction a t room temperature. The experimental and modeling results showed that marginal difference were observed at low gas flux. However the difference between the both models and experimental value were increased when the gas flux was increased. The study concludes that the Model 1 with free ammonia is more appropriate when both models were compared and useful in ammonia stripping process at low gas flux.