• 제목/요약/키워드: fractured surface

검색결과 370건 처리시간 0.026초

베벨각도와 미세기공에 따른 필렛 용접부의 피로강도평가에 관한 연구 (Fatigue Strength Estimation of the Fillet Weldments with Different Beveling Angle and Porosity)

  • 홍춘희;오세종;이원석;이현우
    • 대한기계학회논문집A
    • /
    • 제30권11호
    • /
    • pp.1439-1446
    • /
    • 2006
  • The fatigue test of the fillet weldments was executed with different beveling angles and porosities. The beveling angles of $0^{\circ}$, $45^{\circ}$ and $55^{\circ}$ were compared with fatigue lives. After the fillet weldment failure, the porosities which found at the fractured surface were observed to account the effect on fatigue life. Finite element analysis was performed to correlate the fatigue strength and the sizes and the locations of porosities. The stress-strain field was severely affected by the length of notch and the sizes and locations of porosities. Based on the quantitative analysis of porosity effect, the total volume of porosities was a key factor for fatigue strength of the fillet weldment.

GFRP 복합재료의 층간파괴인성치에 관한 연구 (A Study on the Interlaminar Fracture Toughness of Glass Fiber Reinforced Plastic Comosites)

  • 박기호
    • 수산해양기술연구
    • /
    • 제35권4호
    • /
    • pp.410-420
    • /
    • 1999
  • The value of the mode I interlamina fracture toughness, GIC, is calculated by experimental compliance method, modified compliance method and beam theory. The value of the mode II interlamina fracture toughness, GIC, is evaluated by beam method, theory beam theory and compliance method. This paper describes the effect of load pint displacement rate and speicimen geometries for mode I and II interlaminar fracture toughness of glass fiber reinforced plastic composites by using double cantilever beam (DCB) and end notched flexure (ENF) specimen. For the load point displacement rate of increases whereas the value of 2,6 and 10 mm/min the value of GIC decrease as load point displacement rate increases whereas the value of GIC is found to be no significant effect. The value of GIC decreases as initial crack length increases. The fractured surface of the DCB and ENF samples are examined by scanning electron microscopy (SEM).

  • PDF

소형펀치 시험법을 이용한 INCONEL Alloy 617의 수소취화거동 평가 (Evaluation of Hydrogen Embrittlement Behavior in INCONEL Alloy 617 by Small Punch Test)

  • 서현욱;마영화;윤기봉
    • 한국수소및신에너지학회논문집
    • /
    • 제21권4호
    • /
    • pp.340-345
    • /
    • 2010
  • For the conversion into hydrogen society, not only studying facilities of hydrogen production, storage, transportation and charging system but also developing technique of ensuring safety are essentially needed. Hence, for the first step of that, evaluated the hydrogen embrittlement of Inconel alloy 617, Ni-based super heat-resisting alloy, by small punch test. Prepared the various specimens through changing electrochemical charging time and measured the toughness degradation of the specimens by small-punch test. The analysis of hydrogen embrittlement behavior were carried out by investigating the fractured surface of specimens. This study has significance on revealing mechanism of hydrogen embrittlement behavior and the factor affecting hydrogen embrittlement in the future study.

필렛 용접 시 그루브 각도와 미세기공에 따른 피로강도의 영향 (Effect of Fatigue Strength in Fillet Weldments with Different Groove Angle and Porosity)

  • 구본철
    • 한국기계가공학회지
    • /
    • 제6권2호
    • /
    • pp.9-16
    • /
    • 2007
  • The fatigue test of the fillet weldments were executed with different groove angles and porosity. The groove angles of $90^{\circ}$, $45^{\circ}$ and $55^{\circ}$ were compared with fatigue lives. After the fillet weldment failure, the porosity which found at the fractured surface were observed to account the effect on fatigue life. Finite element analysis were performed to correlate the fatigue strength and the size & the location of porosity. The stress-strain field were severely affected by the length of notch and the size & location of porosity. Based on the quantitative analysis of porosity effect, the total volume of porosity was key factor for fatigue strength of the fillet weldment.

  • PDF

원자로 냉각재배관 엘보우 및 서포트 스컷트용 (Fracture Resistance Characteristics of SA516-Gr.70 Steel Plate for RCS Piping Elbow and Support Skirt)

  • 손종동;임만배
    • 한국안전학회지
    • /
    • 제21권4호
    • /
    • pp.49-54
    • /
    • 2006
  • The evaluation of elastic-plastic fracture characteristic was investigated in ferrite steel SA 516- Gr70 used for reactor coolant piping elbow and support skirt of pressure vessels. This paper describes the effect of temperature on J-R curve characteristic of this material. The elastic-plastic fracture mechanics parameter J is obtained with unloading compliance method. The test method were analyzed according to ASTM E 813-89 and E 1152-89. Unloading compliance $J_{IC}$ tests were performed on 1 CT specimens at varied temperatures from $25^{\circ}C$ to about $400^{\circ}C$ using a high temperature extensometer. At all temperature, valid $J_{IC}$ measurements could be made and $J_{IC}$ decreased with increasing temperature. SEM fractography schematically illustrates microvoid initiation, growth and coalescence at the tip of a preexisting crack.

Fabrication via Ultrasonication and Study of Silicon Nanoparticles

  • Kim, Jin Soo;Sohn, Honglae
    • 통합자연과학논문집
    • /
    • 제8권3호
    • /
    • pp.147-152
    • /
    • 2015
  • Photoluminescent porous silicon (PSi) were prepared by an electrochemical etch of n-type silicon under the illumination with a 300 W tungsten filament bulb for the duration of etch. The red photoluminescence emitting at 620 nm with an excitation wavelength of 450 nm is due to the quantum confinement of silicon nanocrystal in porous silicon. As-prepared PSi was sonicated, fractured, and centrifuged in toluene to obtain photoluminescence silicon quantum dots. BET and BHJ methods were employed to study the specific surface area of as-prepared PSi. Optical characterization of red photoluminescent silicon nanocrystal was investigated by UV-vis and fluorescence spectrometer. Also SEM and TEM images of porous silicon and nanoparticles were investigated.

On the electropolymerization of acrylonitrile as effected by cyclic voltammetry and chronoamperometry method

  • Seo, H.J.;Cho, M.S.;Nam, J.D.;Lee, Y.
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.335-335
    • /
    • 2006
  • Polyacrylonitrile (PAN) was deposited as an adherent film on Cu-substrate by the cathodic electropolymerization. This work is an attempt to compare the molecular weight and the fractured surface of PAN prepared by CV and chronoamperometry. The molecular weight and increase weight of PAN measured the according to AN-concentration, scan rate, and cycle number (or time) using CV and chronoamperometry. The morphology of PAN was characterized by SEM image. Mechanism and optimal conditions for electropolymerization of acrylonitrile on Cu-substrate were investigated and discussed.

  • PDF

혼합강화 복합재료의 인장 및 내마모 특성 (The Tensile Properties and Wear Behavior of Mixing-reinforced Composites by Squeeze Casting Process)

  • 김용현;이광학
    • 한국재료학회지
    • /
    • 제9권4호
    • /
    • pp.392-397
    • /
    • 1999
  • The tensile strength and water resistance of ADC12 alloy matrix composites reinforced with saffil/ceraklwool and saffil/Si particle prepared by squeeze casting have been investigated in room temperature and $250^{\circ}C$. Adhesive and scuffing wear phenomena was studied when load was changed to 10~40N and wear velocity was 2.0m/s at room temperature and $250^{\circ}C$. Generally, the morphology of tensile fractured surface revealed dimple pattern which implies ductile fracture of the composites. However, cleavage fracture was also observed in case of ADC12 alloy based saffil/Si particle composite. The maximum tensile strength of 320MPa was obtained in ADC12 alloy based composites reinforced by saffil/cerakwool(5:5) preformed fibers. In the results of dry wear test, it was observed that scuffing was occurred at 40N in room temperature and 30N for $250^{\circ}C$.

  • PDF

FATIGUE RESISTANCE OF DENTAL IMPLANTS TREATED WITH LASER METHOD

  • Park, Eun-Young
    • 대한치과보철학회지
    • /
    • 제44권6호
    • /
    • pp.734-739
    • /
    • 2006
  • Statement of problem. Many surface processing methods of dental implant have been developed, the laser processing is one of them. Purpose. This study was to investigate in vitro the fatigue resistance of implants treated with laser method(CSM implant, CSM Company, Daegu, Korea). Material and methods. Fatigue tests of 23 laser treated CSM implant(CSM Company, Daegu, Korea) were conducted using Instron 8871 (Load cell, 5 kN, Instron Co., England), according to ISO 14801 (2003), Results. From 300 N, each specimens were not fractured and withstood until more than 5,000,000 cycle. Conclusion. Within the limits of this in vitro study, implants treated with laser method (CSM implant, CSM Company, Daegu, Korea) have had enough rigidity and fatigue resistance to use clinically with reliance.

X-선 회절을 이용한 A1 7075-T651합금의 파손해소 (Failure Analysis in Al 7075-T651 Alloy using X-ray Diffraction Technique)

  • 오세욱;박수영;부명환
    • 한국해양공학회지
    • /
    • 제7권2호
    • /
    • pp.103-113
    • /
    • 1993
  • X-ray diffraction analysis technique was used for the fatigue damage analysis and fatigue life prediction in Al 7075-T651 alloy. The tensile test, fatigue strength and fatigue crack propagation test with change of stress ratio were carried out. As a result, half-value breadth was increased with the plastic deformation in the specimen increasint at all test conditions. In particular, half-value breadth at the surface of the specimens fractured by fatigue was increased as stress intensity factor range and effective stress intensity factor range were increased. In addition, the good relationship between half-value breadty and diffraction pattern was shown.

  • PDF