• Title/Summary/Keyword: fracture tendency

Search Result 162, Processing Time 0.024 seconds

Fibre reinforcement in a structurally compromised endodontically treated molar: a case report

  • Soares, Renita;Ataide, Ida de Noronha de;Fernandes, Marina;Lambor, Rajan
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.2
    • /
    • pp.143-147
    • /
    • 2016
  • The reconstruction of structurally compromised posterior teeth is a rather challenging procedure. The tendency of endodontically treated teeth (ETT) to fracture is considerably higher than vital teeth. Although posts and core build-ups followed by conventional crowns have been generally employed for the purpose of reconstruction, this procedure entails sacrificing a considerable amount of residual sound enamel and dentin. This has drawn the attention of researchers to fibre reinforcement. Fibrereinforced composite (FRC), designed to replace dentin, enables the biomimetic restoration of teeth. Besides improving the strength of the restoration, the incorporation of glass fibres into composite resins leads to favorable fracture patterns because the fibre layer acts as a stress breaker and stops crack propagation. The following case report presents a technique for reinforcing a badly broken-down ETT with biomimetic materials and FRC. The proper utilization of FRC in structurally compromised teeth can be considered to be an economical and practical measure that may obviate the use of extensive prosthetic treatment.

A Study on the Resistance Spot Weldability of 590 MPa Grade DP Steel with Modified Electrode Tip (가공 전극을 적용한 590 MPa급 DP강의 저항 점용접에 관한 연구)

  • Lee, Sang-Min;Park, Yeong-Do
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.1
    • /
    • pp.71-76
    • /
    • 2010
  • The use of advanced high-strength steels (AHSS) in automotive applications has steadily increased over the past few years. Two different failure modes are generally observed in shear-tension tests for resistance spot welds of AHSS. interfacial fractures and full button pullout. Despite high load-carrying capacity. the resistance spot welds in AHSS cue prone to interfacial fractures. To improve the load carrying ability of welds during shear-lap and cross tension tests. the tip surface of the electrode was grooved in a round shape. The electrode tip surface was modified so as to concentrate the current now in the central and circumferential portion of the electrode force. The results showed that the interfacial fracture was suppressed in welds using the modified electrode. In a comparison of failure mode during mechanical tests. the welds made with the modified electrode showed a higher tendency to fail via full button pullout fracture.

Effect of Zn content on Shear Strength of Sn-0.7Cu-xZn and OSP surface finished Joint with High Speed Shear Test (Sn-0.7Cu-xZn와 OSP 표면처리 된 기판의 솔더접합부의 고속 전단강도에 미치는 Zn의 영향)

  • Choi, Ji-Na;Bang, Jae-Oh;Jung, Seung-Boo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.1
    • /
    • pp.45-50
    • /
    • 2017
  • We investigated effect of Zn content on shear strengh of Sn-0.7Cu-xZn and OSP surface finished solder joints. Five pastes of Sn-0.7Cu-xZn (x=0, 0.5, 1.0, 1.5, 2.0 wt.%) solders were fabricated by mixing of solder powder and flux using planatary mixer. $180{\mu}m$ diameter solder balls were formed on OSP surface finished Cu electrodes by screen print method, and the reflow process was performed. The shear strength was evaluated with two high shear speeds; 0.01 and 0.1 m/s. The thickness of the intermetallic compound(IMC) layer was decreased with increasing Zn content in Sn-0.7Cu-xZn solder. The highest shear strength was 3.47 N at the Zn content of 0.5 wt.%. As a whole, the shear strength at condition of 0.1 m/s was higher than that of 0.01 m/s because of impact stress. Fracture energies were calculated by F-x (Force-displacement) curve during high speed shear test and the tendency of fracture energy and that of shear strength were good agreement each other. Fracture took place within solder matrix at lower Zn content, and fracture occured near the interface of OSP surface finished Cu electrode and solder at higher Zn content.

CONSERVATIVE TREATMENT OF BILATERAL CONDYLAR FRACTURE BY A SIMPLIFIED TECHNIQUE OF MAXILLOMANDIBULAR FIXATION (단순악간고정법을 이용한 양측성 하악과두골절의 보존적 치료)

  • Kim, Jong-Pil;Ahn, Sang-Hun;Chang, Heon-Soo;Park, Jae-Bum;Jo, Byung-Woan;Ann, Jye-Jynn
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.17 no.2
    • /
    • pp.171-179
    • /
    • 1995
  • The conservative treatment of the condylar fracture has been used for a long time because of its simplicity, good prognosis and less complication. Traditionally the conservative treatment has been carried out by maxillomandibular fixation using arch bar and wire. But a simplified technique of maxillomandibular fixation introduced here is a procedure that 4 bone screws are placed above the apecies of the maxillary and mandibular canines and then ipsilaterally placed maxillary and mandibular bone screws are linked by a loop of wire each other. This procedure has several advantages compared with the traditional maxillomandibular fixation method. 1) it provides simplicity for the operators. 2) it sustains maxillomandibular fixation more rigidly compared with arch bar technique. 3) it keeps stable maxillomandibular fixation in the region of the anterior teeth so that anterior open bite tendency can be remarkably minimized. 4) it does not injure the periodontal tissue because the teeth are not engaged and causes less discomfort to the patient. 5) it decreases the possibility of operator's AIDS infection through inadvertent skin puncture. 6) it is highly recommended for the patients whose teeth are available for maxillomandibular fixation. The two male patients were diagnosed as bilateral condylar and symphyseal fracture of the mandible. They restored stable occlusion and functional mandibular movement only by a simplified technique of maxillomandibular fixation.

  • PDF

An Experimental Study on the Effects of Hyperbaric Oxygen Therapy on the Healing of Mandibular Fracture of Streptozotocin-Induced Diabetic Rats. (고압산소요법이 당뇨백서 하악골 골절 치유에 미치는 영향에 관한 실험적 연구)

  • Sang, Jai-Woo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.12 no.1
    • /
    • pp.1-13
    • /
    • 1990
  • The main objectives of this study was to observe the effects of hyperbaric oxygen therapy on the healing processes of mandibular fracture of streptozotocin-induced diabetic rats. Author used 60 rats (Sprague-Dawley Strain) deviding into control(30) and experimental groups(30). Complete fracture was produced on the left mandibular body of 60rats, rendered hyperbaric oxygen therapy (2 hrs. daily at 2.5 atm.) on experimental group and observed effects of hyperbaric oxygen therapy by microscopically. The obtained results were as follows; 1. Infiltration of inflammatory cells was no significant differences between the control and experimental group until 3rd week, but experimental group showed decreasing tendency after 4th week. 2. Severe proliferation of fibroblasts showed rather rapider in experimental group, at 2nd week, while at 3rd week in control group. 3. Osteoclasts appeared at 1st week in experimental group while at 3rd week in control group, and experimental group showed early bone resorption pattern. 4. Osteoblasts appeared at 1st week in experimental group while at 3rd week in control group, and experimental group showed prominent osteoblastic activity. 5. Moderate proliferation of capillary blood vessels showed in initial stage of experimental group while mild proliferation at 1-2nd week in control group. 6. Formation of cartilaginous callus showed at 4th week in experimental group, while at 6th week in control group. 7. Formation of bony callus showed mildly at 5th week, and moderately at 6th week in experimental group, while no appearance in control group, but complete bony union was not observed even in experimental group throughout this experiment.

  • PDF

Fracture Behaviors of SiCf/SiC Composites Prepared by Hybrid Processes of CVI and PIP (화학침착법과 고분자함침 열분해법의 복합공정으로 제조한 SiCf/SiC 복합체의 제조 공정에 따른 파괴거동)

  • Park, Ji Yeon;Han, Jangwon;Kim, Daejong;Kim, Weon-Ju;Lee, Sea Hoon
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.5
    • /
    • pp.430-434
    • /
    • 2014
  • $SiC_f$/SiC composites were prepared using the hybrid process of chemical vapor infiltration (CVI) and polymer impregnation and pyrolysis (PIP). Before the application of PIP, partially matrix-filled preform composites with different densities were fabricated by control of chemical vapor infiltration time and temperature. The changes of the final density of the $SiC_f$/SiC composites had a tendency similar to that of preform composites partially filled by CVI. Composites with lower density after the CVI process had a larger increment of density during the PIP process. Three types of microstructures were observed on the fractured surface of the composite: 1) well pulled-out fibers and lower density, 2) slightly pulled-out fibers and higher density, and 3) only bulk SiC. The different fractions and distributions of the microstructures could have an effect on the mechanical properties of the composites. In this study, $SiC_f$/SiC composites prepared using a hybrid process of CVI and PIP had density values in the range of $1.05{\sim}1.44g/cm^3$, tensile strength values in the range of 76.4 ~ 130.7 MPa, and fracture toughness values in the range of $11.2{\sim}13.5MPa{\cdot}m^{1/2}$.

Properties of Electro-Conductive SiC-TiB2 Composites (도전성 ${\beta}-SiC-TiB_2$ 복합체의 특성)

  • Shin, Yong-Deok;Park, Mi-Lim;Song, Joon-Tae;Yim, Seung-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04b
    • /
    • pp.72-75
    • /
    • 2000
  • The effect of $Al_2O_3+Y_2O_3$ additives on fracture toughness of ${\beta}-SiC-TiB_2$ composites by hot-pressed sintering were investigated, The ${\beta}-SiC-TiB_2$ ceramic composites were hot-presse sintered and annealed by adding 4, 8, 12wt% $Al_2O_3+Y_2O_3$(6 : 4wt%) powder as a liquid forming additives at low temperature($1800^{\circ}C$) for 4h. In this microstructures, the relative density is over 97% of the theoretical density and the porosity increased with increasing $Al_2O_3+Y_2O_3$ contents because of the increasing tendency of pore formation. But the fracture toughness showed the highest of $7.0MPa{\cdot}m^{1/2}$ for composites added with 12wt% $Al_2O_3+Y_2O_3$ additives at room temperature. The electrical resistivity showed the lowest of $1.59\times10^{-3}\Omega{\cdot}cm$ for composite added with 8wt% $Al_2O_3+Y_2O_3$ additives at room temperature and is all positive temperature coefficient resistance(PTCR} against temperature up to $700^{\circ}C$.

  • PDF

A survey of experience-based preference of Nickel-Titanium rotary files and incidence of fracture among general dentists

  • Lee, WooCheol;Song, Minju;Kim, Euiseong;Lee, Hyojin;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.4
    • /
    • pp.201-206
    • /
    • 2012
  • Objectives: The purpose was to investigate the preference and usage technique of NiTi rotary instruments and to retrieve data on the frequency of re-use and the estimated incidence of file separation in the clinical practice among general dentists. Materials and Methods: A survey was disseminated via e-mail and on-site to 673 general dentists. The correlation between the operator's experience or preferred technique and frequency of re-use or incidence of file fracture was assessed. Results: A total of 348 dentists (51.7%) responded. The most frequently used NiTi instruments was ProFile (39.8%) followed by ProTaper. The most preferred preparation technique was crown-down (44.6%). 54.3% of the respondents re-used NiTi files more than 10 times. There was a significant correlation between experience with NiTi files and the number of re-uses (p = 0.0025). 54.6% of the respondents estimated experiencing file separation less than 5 times per year. The frequency of separation was significantly correlated with the instrumentation technique (p = 0.0003). Conclusions: A large number of general dentists in Korea prefer to re-use NiTi rotary files. As their experience with NiTi files increased, the number of re-uses increased, while the frequency of breakage decreased. Operators who adopt the hybrid technique showed less tendency of separation even with the increased number of re-use.

A Study on the Comparison of hardness, Strength and Microstructure of dental Non-precious Metal Alloys Colored Goldish Yeller (Goldish Yellow Color인 수종(數種)의 치과용(齒科用) 비귀금속합금(非貴金屬合金) 경도(硬度), 강도(强度) 및 미세조직(微細組織)의 비교(比較)에 관(關)한 연구(硏究))

  • Kim, Jae-Do
    • Journal of Technologic Dentistry
    • /
    • v.14 no.1
    • /
    • pp.55-65
    • /
    • 1992
  • The purpose of this study was to investigate the comparison of physical properties of nonprecious metal alloys colored goldish yellow. The experimental groups were copper based dental alloy and control group was Ni-Cr based dental alloy used crown and bridges frameworks. Hardness was tested by vickers hardness tester, tensile strength was tested by universal tension tester. After testing the tensile strength of castings, the microstrucure and the pattern of fracture were investigated by scanning electron microscope and metallurgical microscope. The results were as follows : Hardness of Ni based alloy was higher than Cu based alloys. Hardness number of A group was 200.41$\pm$16.10 Hv, B group was 194.33$\pm$1.69 Hv, C group was 139.29$\pm$2.19 Hv and D group was 293.81$\pm$27.17 Hv, respectively. Tensile strength of D group was 56.42$\pm$6.17 $kg/m^2$, A group was 50.39$\pm$5.68 $kg/m^2$, C group was 45.13$\pm$4.53 $kg/m^2$, B group was 45.25$\pm$9.25 $kg/m^2$, in order, and D group was maximum tensile strength. The fractured surfaces of tensile specimens in the all groups showed the tendency to form large voids in the center of specimens. Thus the ductile fracture was changed into the brittle fracture with the fine grain size.

  • PDF

Mechanical and Impact Properties and Heat Deflection Temperature of Wood Flour-reinforced Recycled Polyethylene Green Composites (목분강화 재활용폴리에틸렌 그린복합재료의 기계적 특성, 충격 특성 및 열변형온도)

  • Lee, Ki-Young;Cho, Dong-Hwan
    • Elastomers and Composites
    • /
    • v.46 no.3
    • /
    • pp.223-230
    • /
    • 2011
  • Considering of utilizing renewable resources and recycled plastics, green composites consisted of recycled polyethylene (PE) as matrix and eco-friendly natural fibers as reinforcement were processed and characterized in the present study. First, the wood flour/recycled polyethylene pellets with different wood flour contents were prepared by twin-screw extrusion processing. Using the pellets, wood flour/recycled polyethylene green composites were fabricated and the effects of wood flour loading on their flexural, tensile, impact properties, heat deflection temperature and fracture behavior were investigated. It was concluded that the flexural strength, flexural modulus, tensile modulus and heat deflection temperature of wood flour/recycled polyethylene green composites were increased with wood flour, whereas the tensile strength and impact strength were decreased. The fracture behavior observed by means of scanning electron microscopy supported qualitatively the tendency of the impact strength with wood flour loading, compared with the ductile fracture pattern of recycled polyethylene.