• Title/Summary/Keyword: fracture pattern

Search Result 393, Processing Time 0.029 seconds

Influence of modification in core building procedure on fracture strength and failure patterns of premolars restored with fiber post and composite core

  • Kim, Young-Hoi;Lee, Jong-Hyuk
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.1
    • /
    • pp.37-42
    • /
    • 2012
  • PURPOSE. The influence of the modified process in the fiber-reinforced post and resin core foundation treatment on the fracture resistance and failure pattern of premolar was tested in this study. MATERIALS AND METHODS. Thirty-six human mandibular premolars were divided into 4 groups (n = 9). In group DCT, the quartz fibre post (D.T. Light-post) was cemented with resin cement (DUO-LINK) and a core foundation was formed with composite resin (LIGHT-CORE). In group DMO and DMT, resin cement (DUO-LINK) was used for post (D.T. Lightpost) cementation and core foundation; in group DMO, these procedures were performed simultaneously in one step, while DMT group was accomplished in separated two steps. In group LCT, the glass fiber post (LuxaPost) cementation and core foundation was accomplished with composite resin (LuxaCore-Dual) in separated procedures. Tooth were prepared with 2 mm ferrule and restored with nickel-chromium crowns. A static loading test was carried out and loads were applied to the buccal surface of the buccal cusp at a 45 degree inclination to the long axis of the tooth until failure occurred. The data were analyzed with MANOVA (${\alpha}$= .05). The failure pattern was observed and classified as either favorable (allowing repair) or unfavorable (not allowing repair). RESULTS. The mean fracture strength was highest in group DCT followed in descending order by groups DMO, DMT, and LCT. However, there were no significant differences in fracture strength between the groups. A higher prevalence of favorable fractures was detected in group DMT but there were no significant differences between the groups. CONCLUSION. The change of post or core foundation method does not appear to influence the fracture strength and failure patterns.

A Study on Waterjet Fracture Mechanism for Granitic Rocks (화강암에 대한 워터젯 파쇄 메커니즘에 관한 연구)

  • Oh, Tae-Min;Cho, Gye-Chun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.643-648
    • /
    • 2010
  • Waterjet is a very useful technology for rock excavation because of low level noise and vibration during breaking rocks. To accurately predict the volume and shape excavated by the waterjet, it is important to understand waterjet fracture mechanisms. There have been various theoretical assumptions and approaches in the literature. In this study, waterjet mechanisms are classified into three standards: a mechanism scale, theoretical assumption for a target material, and jet phase. In addition, through a waterjet experimental study for weathered and intact granitic rocks, a fracture shape is observed and analyzed on comparison with the previous mechanisms. As a result, best waterjet mechanisms are selected to explain the fracture pattern of the granitic rocks.

  • PDF

Experimental Study on Fracture Behavior of Low-Heat Concrete, by Three-Point Bent Test (3점 휨시험에의한 저발열콘크리트의 파괴거동에 곤한 실험적 연구)

  • 조병완;박승국
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.199-204
    • /
    • 1998
  • To analysis the failure character of Low-Heat concrete which is used to prevent the thermal crack caused by hydration heat, static loading test was performed by this test method, "Determination of the Fracture Energy of Motar and Concrete by Means of Three-Point Band Tests on Notched Beam" (suggested by RILEM 50-FMC Committe). This study compared and analysised the fracture energy of Mode I (opening mode), the most general pattern in the view of water-cemente ratio(W/C), compressive strength and age of Ordinary Portland Concrete and Low-Heat Concrete under the same mixture. The test results show that the case of Ordinary Portland Concrete and Low-Heat Concrete, low Water-Cemente ratio(W/C) cause the increase of fracture energy, and high failure-strength decrease failure-deflection, and the fracture energy of Low-Heat Concrete is similar to Ordinary Portland Concrete as the age increase. increase.

  • PDF

Integrity evaluations of bogie frame using ultrasonic-fractography analysis (초음파-파면해석에 의한 대차 프레임의 건전성 평가)

  • 윤인식;권성태;정우현;박덕신;김경국
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.461-467
    • /
    • 2000
  • This study proposes the integrity evaluation of bogie frame using ultrasonic waves-fractography analysis. Analysis objectives in this study are to investigate fracture planes of damaged zone by the A-scan method. The surface condition of fracture plane shows degree of degradation by stress concentration. The detection of the natural defects in bogie frame is performed using the characteristics of echodynamic pattern in ultrasonic signal. Results of ultrasonic testing agree fairly well with those of actual fracture plane. In quantitative fractography analysis, microstructures of actual fracture plane turned out to be intergranular and transgranular fracture, Proposed ultrasonic-fractography analysis in this study can be used for the integrity evaluation of the bogie frame

  • PDF

Zygomaticomaxillary complex fracture after two-jaw surgery

  • Park, Joseph Kyu-hyung;Kim, Sang Wha
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.5
    • /
    • pp.301-304
    • /
    • 2020
  • Orthognathic surgeries often utilize rigid fixation for stabilization of the osteotomy site. The longterm fate of rigid fixations is still under investigation, and whether they should be routinely removed is under debate despite their low complication rates. Here, we report a case where a 26-year-old man suffered high-velocity trauma to his face 7 years after a two-jaw surgery. Computed tomography examination revealed a zygomaticomaxillary complex fracture, and open reduction and internal fixation was performed along with anterior maxillary wall reconstruction using absorbable mesh. Intraoperative examination revealed a broken L-shaped titanium plate near the fracture site with multiple bony fragments near each titanium screw. The rigid titanium system may have caused comminution of the fracture pattern, worsening the severity of the fracture.

Effect of Copper and Heat Treatment on the Fracture Toughness of Ductile Cast Iron (구상흑연주철의 파괴특성에 미치는 Cu 및 열처리의 영향)

  • Kim, Won-Yong;Ra, Tae-Youb;Kang, In-Chan;Kwak, Chang-Sub
    • Journal of Korea Foundry Society
    • /
    • v.13 no.6
    • /
    • pp.555-562
    • /
    • 1993
  • A study was investgated the relationship between fracture characteristics and microstructure changes according to Cu addition and heat treatment methods on the ductile cast iron. According to increment of Cu addition pearlite volume fraction was increased due to the deffect of anti-ferritizing of Cu. At the case of austempering heat treatment, fracture toughness of Cu contained specimen was decreased. The reason for the results seems to be responsible for decrement of plastic zone size at the crack tip. It was observed that the excellent fracture toughness can be obtained at the condition of normalizing and the specimen was not contained Cu. Under the such conditions, fractographs is composed of dimple pattern and fracture toughness 71.6MPa $\sqrt{m}$, tensile strength determined as the value of 961.6MPa, respectively.

  • PDF

Integrity Evaluation of Bogie Frame by Ultrasonic Fractography Analysis (초음파 파면해석에 의한 대차 프레임의 건전성 평가)

  • 윤인식;권성태;선종성;명노종;정우현;손태순;김경국;김순철
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.2
    • /
    • pp.77-83
    • /
    • 2000
  • This study proposes the integrity evaluation of the bogie frame using ultrasonic fractography analysis. Analysis objectives in this study are to investigate fracture planes of damaged zone by the A-scan method. The surface condition of fracture planes shows degree of degradation by the stress concentration. The detection of the natural defects in the bogie frame is performed using the characteristics of echodynamic pattern in ultrasonic signal. Results of ultrasonic testing agree fairly well with those of actual fracture plane. In quantitative fractography analysis, microstructures of actual fracture plane turned out to be intergranular and transgranular fracture. Proposed ultrasonic fractography analysis in this study can be used for the integrity evaluation of the bogie frame.

  • PDF

A comparative study on the fracture strength of esthetic porcelain crowns (심미도재관의 파절 강도 비교 연구)

  • Kim, Eun-Ha;Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.79-85
    • /
    • 2007
  • In this study, We tried to find out the fracture strength of zirconia coping all ceramic crown and collarless porcelain fused gold alloy crown as the compared group. Each of the collarless porcelain fused gold crown and zirconia all ceramic crown has been produced specimen 10 each. And after pasting them on the steel jig, it had load given at porcelain incisal edge by 130$^{\circ}$ and measured fracture strength by Universal Testing Machine and then We have results from that. 1. The average value of fracture strength suggested 950.49 N at collarless porcelain fused gold alloy crown, 656.81 N at zirconia coping all ceramic crown. 2. Fractured pattern showed that the whole of labial part was exposed in collarless porcelain fused gold crown, but porcelain of margin part did not show fracture in advance. In the practice, the concern that collarless might cause fracture strength to be weaken does not matter, we concluded zirconia all ceramic crown made fracture that only a part of labial porcelain was fractured. The combination of zirconia all ceramic crown and turned out to be excellent.

  • PDF

A Study on Validation of Variable Aperture Channel Model: Migration Experiments of Conservative Tracer in Parallel and Wedge-Shaped Fracture

  • Keum, D.K.;Hahn, P.S.;Vandergraaf, T.T.
    • Nuclear Engineering and Technology
    • /
    • v.30 no.3
    • /
    • pp.245-261
    • /
    • 1998
  • In order to validate the variable aperture channel model that can deal with the non-uniform How rate in flow domain, migration experiments of conservative tracer were performed in two artificial fractures, a parallel and a wedge-shaped fracture. These different fracture shapes were designed to give different flow pattern. The fractures were made from a transparent acrylic plastic plate and a granite slab with dimensions of 10 $\times$ 61 $\times$ 61 cm. Uranine (Fluorescein sodium salt) was used as a conservative tracer. The volumetric flow rates of uranine feed solution were 30 mL/ hr, giving a mean residence time in the fracture of approximately 24 hours for the parallel fracture and 34 hours for the wedge-shaped fracture. The migration plumes of uranine were photographed to obtain profiles in space and time for movement of a tracer in fractures. The photographed migration plume was greatly affected by the geometric shape of fractures. The variable aperture channel model could have predicted the experimental results for the parallel fracture with a large accuracy. It is expected that the variable aperture channel model would be effective to predict the transport of the contaminant, especially, with the flow rate variation in a fracture.

  • PDF

Two Part Triplane Fracture with Extention through Medial Malleolus (Four Cases Report) (족관절 내과를 침범한 두 부분 삼면 골절(4예 보고))

  • Cha, Seung-Do;Kim, Hyung-Soo;Chung, Soo-Tae;Yoo, Jeong-Hyun;Park, Jai-Hyung;Kim, Joo-Hak;Kim, Yong-Hoon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.2
    • /
    • pp.179-183
    • /
    • 2009
  • The triplane fracture has been described as a fracture of the distal tibial epiphysis occurring across three planes-sagittal, transverse and coronal. The characteristic pattern of fusion of distal tibial epiphysis explains the special configuration of the fragments in the triplane fracture. According to Dias-Tachdjian classification, triplane fracture is classified two part fracture, three part fracture, four part fracture and two part fracture with extension to the medial malleolus. Among four types, two part triplane fracture with extension to the medial malleolus is a relatively rare injury and generally is not treated by closed reduction. Such fractures should have an anatomic reduction and adequate fixation to restore the joint congruity and obtain an anatomic reduction of the growth plate to prevent a future growth deformity. This is usually best accomplished with an open reduction and screw fixation or k-wire fixation. We experienced two part triplane fracture with extension to medial malleolus and check the CT to define the extent of the injury completely. And then we underwent open reduction and screw fixation for the fracture. As a result, we present four cases of two part triplane fracture with extension with review of related literatures.

  • PDF