• Title/Summary/Keyword: fr-closed

Search Result 23, Processing Time 0.021 seconds

Evapotranspiration Rate of Grafted Seedlings Affected by Relative Humidity and Photosynthetic Photon Flux under Artificial Lighting (인공광하에서 접목묘의 증발산속도에 미치는 상대습도와 광합성유효광량자속의 효과)

  • 김용현;박현수
    • Journal of Biosystems Engineering
    • /
    • v.26 no.4
    • /
    • pp.379-384
    • /
    • 2001
  • To enhance the smooth graft-taking of grafted seedlings, the excessive evapotranspiration from grafted seedlings just after grafting should be avoided. A measurement system of the evapotranspiration rate of grafted seedling under artificial lighting was set up to investigate the effect of physical environment on the evapotranspiration and graft-taking characteristics of grafted seedlings quantitatively. The evapotranspiration rate of grafted seedlings affected by relative humidity and light intensity were analyzed using the measurement system. The hypocotyl of watermelons (Citrullus vulgaris cv. Sweetdew, Hungnong Seed Co.) was slantly cut and then inserted into a hole on the stem of rootstock (Lagenaria siceraria cv. FR-King, Hungnong Seed Co.). Grafted seedlings were healed and joined for 5 days under cool-white fluorescent lamps (FL20SEX-d/18, Keumho Electric Co.) with photoperiod of 12h$.$d$\^$-1/ except dark period for one day after grafting in a closed graft-taking enhancement system developed by Kim(2000). The evapotranspiration rate and graft-taking of grafted seedling at air temperature of 23$\^{C}$ and air current speed of 0.1m$.$s$\^$-1/ was highly affected by relative humidity. But light intensity showed higher effect on the stem length of scion than relative humidity. In conclusion, it was suggested that relative humidity should be controlled at higher than 90% with photosynthetic photon flux of 50$\mu$mol$.$m$^2$$.$s$\^$-1/ to increase the survival of grafted seedlings and to produce healthy seedlings.

  • PDF

Improvement of Light Extraction Efficiency of GaN-Based Vertical LED with Microlens Structure

  • Kwon, Eunhee;Kang, Eun Kyu;Min, Jung Wook;Lee, Yong Tak
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.221-221
    • /
    • 2013
  • Vertical LED (VLED) has been recognized as a way to obtain the high-power LED due to their advantages [1]. However, approximately 4% of the light generated from the active region is extracted, if the light extraction from side walls and back side is neglected because of Fresnel reflection (FR) and total internal reflection (TIR) [2,3]. In this study, the optical simulation of the VLED with the various microstructures was performed. Among them, the microlens having the diameter of 3 ${\mu}m$ and the height of 1.5 ${\mu}m$ shown the best result was chosen, and then, optimized microlens was formed on a GaN template using conventional semiconductor process. Various microstructures were proposed to improve the light extraction efficiency (LEE) of the VLED for the simulation. The LEE was simulated using LightTools based on a Monte Carlo ray tracing. The microstructures with hemisphere, cone, truncated and cylinder pattern having diameter of 3 ${\mu}m$ were employed on the top layer of the VLED respectively. The improvement of the LEE by using the microstructure is 87% for the hemisphere, 77% for the cone, 53% for the truncated, 21% for the cylinder, compared with the LEE of the flat surface at the reflectance of 85%. The LEE was increased by 88% at the height of 1.5 ${\mu}m$, compared with the LEE of the flat surface. We found that the microlens on the top layer is the most suitable for increasing the LEE. In order to apply the proposed microlens on n-GaN surface, we fabricated microlens on a GaN template. A photoresist array having hexagonal-closed packed microlens was fabricated on the GaN template. Then, optimization of etching the GaN template was performed using a dry etching process with ICP-RIE. The dry etching carried out using a gas mixture of Cl2 and Ar, each having a flow rate of 16 sccm and 10 sccm, respectively with RF power of 50 W, ICP power of 900 W and chamber pressure of 2 mTorr was the optimum etching condition as shown in Fig. 2(a).

  • PDF

Effects on Surgical Repair of VSD by TATV (막성주위형 심실중격결손중의 봉합시 경삼첨판륜 절개방법의 외과적 치료효과)

  • Gwak, Mong-Ju;Kim, Bo-Yeong
    • Journal of Chest Surgery
    • /
    • v.30 no.9
    • /
    • pp.869-875
    • /
    • 1997
  • Perimembranous ventri ular septal defects(PMVSDS) are the most common type of ventricular septal defects(VSDs) and consist morphologically of deficiency of the membranous septum and variable portions of the adjacent muscular septum. Repair of VSD has begun via a right ventriculotomy. Even with this exposure, however, it mght lead to ventricular dysfunction. Transatrial exposure of VSDs is luiown to a versatile approach to PMVSDS and even malaligunent defects can be repaired by this method. Although transatrial exposure can be improved by taking down'the atrioventricular valve at the annulus, surgeons have been hesitant to do so because of concern for valvular competence. Therefore, this study was undertaken to clarity the effects of transamlular approach of tricuspid valve (TATV) at operation of PMVSD. During last 5 years, twenty eight cases from 96 patients of PMVSD were closed by TATV and follow up study was done from 3 months to 33 months and results were obtained as follows. 1. Age at operation was fr m 4 months to 38 years and most patients(17, 62%) were above 5 years. 2. Preoperative pulmonary-systemic flow ratio(QPIQS) was ranged from 1 to 2.8 and 22 patients(79%) were less than 2. 3. Peak systolic pulmonary artery pressure was below 30mmHg in 8, 30-50mmHg in 17, above 50mmHg in 3 patients and 25 patients(89%) were less than 50mmHg. 4. Preoperative tricuspid regurgitation(TR) is none in 12, trivial in 6, mild in 3, moderate in 5, severe in 2 patients but postoperative TR was none in 18, trivial in 6, mild in 4 patients, so TR in most patients had decreased or not. 5. Indications for operation were based on the presence of a significant shunt. However, in patients with small shunts, indications for operation were included additional factors, tricuspid valve pouch, RVOT obstruction(right ventricular outflow tract obstruction), subacute bacterial endocarditis and associated anomalies. 6. There were no hospital deaths and residual shunts in postoperative echocardiography. Therefore TATV is especially a good method in PMVSn where patients have trcuspid valve pouch. And it is a safe and effective technique that improves exposure for PMVSD repair and does not adversely affect tricuspid valvular competence.

  • PDF