• Title/Summary/Keyword: four parameter distribution

Search Result 156, Processing Time 0.03 seconds

수명이 대수정규분포를 따를 때 연속 및 간헐적 검사하에서 가속수명시험의 설계와 소표본 연구 (Design of Accelerated Life Tests and Small Sample Study under Continuous and Intermittent Inspections for Lognormal Failure Distribution)

  • 서순근;정원기
    • 대한산업공학회지
    • /
    • 제23권1호
    • /
    • pp.177-196
    • /
    • 1997
  • In this paper, statistically optimal accelerated life test(ALT) plans considering statistical efficiency only and new compromise ALT plans to sacrifice some statistical efficiency in return for improved overall properties including estimobility probability and robustness for the model assumptions are developed under the assumptions of constant stress, intermittent inspection, Type I censoring and lognormal failure distribution which has been one of the popular choices of failure distributions in the extensive engineering applications of ALT. Computational experiments are conducted to compare with four ALT plans including two proposed ones under continuous and intermittent inspections over a range of parameter values in terms of asymptotic variance, sensitivities for guessed input values, and proportion of estimable samples, etc. The small and moderate sample properties for the proposed ALT plans designed under asymptotic criterion are also investigated by Monte Carlo simulation.

  • PDF

Length-biased Rayleigh distribution: reliability analysis, estimation of the parameter, and applications

  • Kayid, M.;Alshingiti, Arwa M.;Aldossary, H.
    • International Journal of Reliability and Applications
    • /
    • 제14권1호
    • /
    • pp.27-39
    • /
    • 2013
  • In this article, a new model based on the Rayleigh distribution is introduced. This model is useful and practical in physics, reliability, and life testing. The statistical and reliability properties of this model are presented, including moments, the hazard rate, the reversed hazard rate, and mean residual life functions, among others. In addition, it is shown that the distributions of the new model are ordered regarding the strongest likelihood ratio ordering. Four estimating methods, namely, method of moment, maximum likelihood method, Bayes estimation, and uniformly minimum variance unbiased, are used to estimate the parameters of this model. Simulation is used to calculate the estimates and to study their properties. Finally, the appropriateness of this model for real data sets is shown by using the chi-square goodness of fit test and the Kolmogorov-Smirnov statistic.

  • PDF

집중변수모델을 이용한 LED조명등 방열기구의 성능분석 (Performance Analysis of Heat Sink for LED Downlight Using Lumped Parameter Model)

  • 김의광;조영철;이승신;안영훈
    • 에너지공학
    • /
    • 제26권2호
    • /
    • pp.64-72
    • /
    • 2017
  • 중동지역 환경에 적합한 70 W급 LED 조명등의 성능분석을 집중변수모델을 이용하여 수행하였다. LED 조명등은 발열기판, 히프파이프, 방열판으로 구성된다. LED 조명등을 4개의 물체로 구분하고, 각각에 대해 에너지평형을 적용하여, 4개의 연립 비선형미분방정식 형태의 집중변수모델을 수립하였다. 연립 방정식의 해는 Runge-Kutta법을 이용하여 구하였다. 집중변수모델의 대류열전달계수는 다차원해석을 통하여 구하였으며, 실험결과와 비교한 결과, 발열기판은 $1.5^{\circ}C$, 상부방열판에서 $1.8^{\circ}C$의 오차를 가지며, 상대오차는 약 0.6 %임을 확인하였다. 이 모델을 이용하여 대기온도가 $55^{\circ}C$인 정상 운전조건, 태양광만 주어질 때의 조건, 태양광이 주어진 상태에서의 비정상 운전조건, 상부방열판이 없는 경우 등에 대한 온도분포분석을 수행하였다.

토양수분특성 추정을 위한 입자크기분포 모형들의 비교 (Comparison of Particle-Size Distribution Models for Estimating Water Retention Characteristic)

  • 황상일
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제7권3호
    • /
    • pp.103-114
    • /
    • 2002
  • 불포화토양내 물의 흐름과 유기오염물질의 이동현상을 예측하기 위해서는 불포화토양의 토양수분곡선을 구하는 것이 필수적이다. 입자크기분포로부터 토양수분곡선을 직접 구하는 물리경험적 방법이 많은 연구자들에 의해 제안되고 적용되어왔다. 이 방법은 공극크기분포가 직접적으로 입자크기분포와 상호 연관되어있다는 개념을 이용한 것으로, 입자크기분포곡선을 산정하는 방법이 토양수분곡선추정에 영향을 미칠 수 있다는 것을 의미한다. 본 연구에서는 Arya-Paris 모형을 이용한 토양수분곡선 추정이 어떠한 입자크기분포모형을 선택하는가에 따라 영향을 받는지를 알아보고자 하였다. 1∼4의 추정변수를 갖는 4개의 입자분포곡선 모형을 사용한 결과 단지 1개의 추정변수를 갖는 Jaky모형이 더 많은 추정변수를 가진 모형보다 토양수분곡선을 잘 예측하였다. Jaky모형의 우월한 예측력은 아마도 현장토양이 가지는 구조적 특성 때문인 것으로 사료된다.

측 추력 제트가 미사일의 공력특성에 미치는 영향에 관한 연구 : Part II. 자유류-제트 각 영향 (Numerical Investigation of the Lateral Jet Effect on the Aerodynamic Characteristics of the Missile: Part II. Freestream-Jet Angle Effect)

  • 민병영;이재우;변영환;현재수;김상호
    • 한국항공우주학회지
    • /
    • 제32권9호
    • /
    • pp.27-34
    • /
    • 2004
  • 측 추력(Lateral Jet) 제어 시스템에 의해 자세제어를 하는 미사일 주위의 초음속 유동장 해석을 위하여 삼차원 Navier-Stokes 코드 (AADL3D)를 개발하고, 이를 이용한 수치해석 연구를 수행하였다. 미사일의 받음각, 제트 노즐의 위치, 그리고 제트의 분출 각 등의 Parameter가 미사일에 미치는 수직력 및 피칭모멘트에 대한 영향을 알아보기 위한 사례 연구를 수행하였다. 또한 미사일은 무게 중심을 기준으로 4개 영역으로 나뉘어 각 부분에서의 수직력과 모멘트에 대한 기여도를 비교하였다. 공력해석 결과, 각 Parameter 변화에 대한 서로 다른 수직력과 모멘트 변화양상 및 그 원인을 확인할 수 있었다. 또한 각 Parameter 의 적절한 조합에 의해 모멘트 발생을 최소화 할 수 있음을 보여 주었다.

우리나라 도시배수시스템 설계를 위한 확률강우강도식의 유도 (A Derivation of Rainfall Intensity-Duration-Frequency Relationship for the Design of Urban Drainage System in Korea)

  • 이재준;이정식
    • 한국수자원학회논문집
    • /
    • 제32권4호
    • /
    • pp.403-415
    • /
    • 1999
  • 본 연구에서는 우리나라 강우에 대한 대표 확률분포형을 결정하고 결정된 대표 확률분포형에 의거하여 확률강우강도식을 유도한다. 빈도해석에 널리 사용되는 11개 분포형에 대하여 모멘트법과 최우추정법 및 확률가중모멘트법으로 모수를 추정하고, 적정성이 있는 모수를 대상으로 적합도 검정을 실시하여 지속기간별로 각 지점의 적정분포형을 구한다. 전 지역의 강우 동질성을 검정하는 방법으로 비모수적 검정방법인 Mann-Whitney 검정과 Kruskal-Walls 검정을 실시하여 우리나라 전역을 대표할 수 있는 대표 적정분포형을 구한다, 강우의 동질성 검정을 실시한 결과, 우리나라 전역을 대표할 수 있는 적정분포형을 선정할 수 없었으며, 12개 지속기간에 대하여 강우의 동질성이 있는 여러 개의 권역으로 구분하여 권역별 대표 확률분포형을 결정하였다. I,II,V 권역에서는 GEV 분포,III,IV 권역에서는 TypeIII 극차분포가 대표 적정분포형으로 선정되었으며, 이들 대표 적정분포형으로부터 얻어진 확률강우량을 이용하여 확률강우강도식을 유도하였다.

  • PDF

와이블 분포함수를 이용한 하수관로 노후도 추정 (Estimation of sewer deterioration by Weibull distribution function)

  • 강병준;유순유;박규홍
    • 상하수도학회지
    • /
    • 제34권4호
    • /
    • pp.251-258
    • /
    • 2020
  • Sewer deterioration models are needed to forecast the remaining life expectancy of sewer networks by assessing their conditions. In this study, the serious defect (or condition state 3) occurrence probability, at which sewer rehabilitation program should be implemented, was evaluated using four probability distribution functions such as normal, lognormal, exponential, and Weibull distribution. A sample of 252 km of CCTV-inspected sewer pipe data in city Z was collected in the first place. Then the effective data (284 sewer sections of 8.15 km) with reliable information were extracted and classified into 3 groups considering the sub-catchment area, sewer material, and sewer pipe size. Anderson-Darling test was conducted to select the most fitted probability distribution of sewer defect occurrence as Weibull distribution. The shape parameters (β) and scale parameters (η) of Weibull distribution were estimated from the data set of 3 classified groups, including standard errors, 95% confidence intervals, and log-likelihood values. The plot of probability density function and cumulative distribution function were obtained using the estimated parameter values, which could be used to indicate the quantitative level of risk on occurrence of CS3. It was estimated that sewer data group 1, group 2, and group 3 has CS3 occurrence probability exceeding 50% at 13th-year, 11th-year, and 16th-year after the installation, respectively. For every data groups, the time exceeding the CS3 occurrence probability of 90% was also predicted to be 27th- to 30th-year after the installation.

Dynamic analysis of functionally graded nonlocal nanobeam with different porosity models

  • Ghandourh, Emad E.;Abdraboh, Azza M.
    • Steel and Composite Structures
    • /
    • 제36권3호
    • /
    • pp.293-305
    • /
    • 2020
  • This article presented a nanoscale modified continuum model to investigate the free vibration of functionally graded (FG) porous nanobeam by using finite element method. The main novelty of this manuscript is presenting effects of four different porosity models on vibration behaviors of nonlocal nanobeam structure including size effect, that not be discussed before The proposed porosity models are, uniform porosity distribution, symmetric with mid-plane, bottom surface distribution and top surface distribution. The nano-scale effect is included in modified model by using the differential nonlocal continuum theory of Eringen that adding the length scale into the constitutive equations as a material parameter constant. The graded material is distributed through the beam thickness by a generalized power law function. The beam is simply supported, and it is assumed to be thin. Therefore, the kinematic assumptions of Euler-Bernoulli beam theory are held. The mathematical model is solved numerically using the finite element method. Results demonstrate effects of porosity type, material gradation, and nanoscale parameters on the free vibration of nanobeam. The proposed model is effective in vibration analysis of NEMS structure manufactured by porous functionally graded materials.

콘크리트 휨피로수명의 확률분포 (Probabilistic Distributions of Fatigue Life of Concrete Subjected to Flexural Loading)

  • 오병환;이희택
    • 대한토목학회논문집
    • /
    • 제6권2호
    • /
    • pp.103-109
    • /
    • 1986
  • 본(本) 논문(論文)에서는 작용되는 피로하중의 크기에 따른 콘크리트의 피로수명분포를 연구(硏究)하였다. 콘크리트보에 대하여 휨피로 실험을 수행하였으며, 피로응력의 크기는 세 가지로서 정적휨강도의 각각 85%, 75% 및 65%로 하여 피로수명을 측정하였다. 본 연구의 실험결과 피로하중의 크기에 따라 확률분포함수의 형태가 비교적 크게 달라짐을 발견하였으며, 이것은 콘크리트의 피로신뢰해석시 피로하중의 크기에 대한 영향을 고려해야 함을 말해 주고 있다. 분포매개변수의 결정은 도식법, 모멘트법 및 Maximum Likelihood 방법에 의거하였다. 콘크리트의 휨피로수명의 Weibull 분포(分布) 형상매개변수는 하중의 크기에 따라 2.0~4.0의 범위에 있는 것으로 나타났다.

  • PDF

Weibull distribution based constitutive model for nonlinear analysis of RC beams

  • Murthy, A. Ramachandra;Priya, D. Shanmuga
    • Structural Engineering and Mechanics
    • /
    • 제61권4호
    • /
    • pp.463-473
    • /
    • 2017
  • Reinforced concrete is a complex material to be modeled in finite element domain. A proper material model is necessary to represent the nonlinear behaviour accurately. Though the nonlinear analysis of RC structures evolved long back, still an accurate and reliable model to predict the realistic behaviour of components are limited. It is observed from literature that there are three well-known models to represent the nonlinear behaviour of concrete. These models include Chu model (1985), Hsu model (1994) and Saenz model (1964).A new stress-strain model based on Weibull distribution has been proposed in the present study. The objective of the present study is to analyze a reinforced concrete beam under flexural loading by employing all the models. Nonlinear behaviour of concrete is considered in terms of stress vs. strain, damage parameter, tension stiffening behaviour etc. The ductility of the RC beams is computed by using deflection based and energy based concepts. Both deflection ductility and energy based ductility is compared and energy based concept is found to be in good correlation with the experiments conducted. The behavior of RC beam predicted using ABAQUS has been compared with the corresponding experimental observations. Comparison between numerical and experimental results confirms that these four constitutive models are reliable in predicting the behaviour of RC structures and any of the models can be employed for analysis.