• 제목/요약/키워드: foundation slab

검색결과 86건 처리시간 0.022초

Investigation on economical method of foundation construction on soft soils in seismic zones: A case study in southern Iran

  • Javad Jalili;Farajdollah Askari;Ebrahim Haghshenas;Azadeh Marghaiezadeh
    • Geomechanics and Engineering
    • /
    • 제32권2호
    • /
    • pp.209-232
    • /
    • 2023
  • A comprehensive study was conducted to design economical foundations for a number of buildings on soft cohesive soil in the southern coastal regions of Iran. Both static and seismic loads were considered in the design process. Cyclic experiments indicated that the cohesive soil of the area has potential for softening. Consequently, the major challenge in the design stages was relatively high dimensions of settlement, under both static and seismic loadings. Routine soil-improvement methods were too costly for the vast area of the project. After detailed numerical modeling of different scenarios, we concluded that, in following a performance-based design approach and applying a special time schedule of construction, most of the settlement would dissipate during the construction of the buildings. Making the foundation as rigid as possible was another way to prevent any probable differential settlement. Stiff subgrade of stone and lime mortar under the grid foundation and a reinforced concrete slab on the foundation were considered as appropriate to this effect. In favor of an economical design, in case the design earthquake strikes the site, the estimations indicate no collapse of the buildings even if considerable uniform settlements may occur. This is a considerable alternative design to costly soil-improvement methods.

Measured structural response of a long irregular pit constructed using a top-down method

  • Yang, Sun;Yufei, Che;Zhenxue, Gu;Ruicai, Wang;Yawen, Fan
    • Geomechanics and Engineering
    • /
    • 제31권5호
    • /
    • pp.489-503
    • /
    • 2022
  • A 1257-m-long irregular deep foundation pit located in the central of Nanjing, China was constructed using the combined full-width and half-width top-down method. Based on the long-term field monitoring data, this study analyzed the evolution characteristics of the vertical movement of the columns, internal force of the struts, and axial force of the structural beam and slab. The relevance of the three mentioned above and their relationship with the excavation process, structural system, and geological conditions were also investigated. The results showed that the column uplift was within the range of 0.08% to 0.22% of the excavation depth, and the embedded depth ratio of the diaphragm wall and the bottom heave affected significantly on the column uplift. The differential settlement between the column and diaphragm wall remained unchanged after the base slab was cast. The final settlement of the diaphragm wall was twice the column uplift. The internal force of the struts did not varied monotonically but was related to numerous factors such as the excavation depth, number of struts, and environmental conditions. Additionally, the dynamic force and deformation of the columns, beams, and slabs were analyzed to investigate the inherent relationship and variation patterns of the responses of different parts of the structure.

측방유동 연약지반상 파일슬래브로 보강된 교대의 안정 (The Stability of Bridge Abutment Reinforced by Pile-slab on Soft Ground Undergoing Lateral Flow)

  • 홍원표;송영석
    • 한국지반공학회논문집
    • /
    • 제22권8호
    • /
    • pp.13-24
    • /
    • 2006
  • 연약지반상에서 교대 뒷채움으로 인하여 측방이동이 발생된 교대에 대하여 현장조사를 수행하였다. 교대측방이동의 원인을 분석한 결과, 설계시 교대기초말뚝을 수동말뚝으로 고려하지 않고, 연약지반에 대한 개량이 충분히 이루어지지 않은 것으로 조사되었다. 교대측방이동에 대한 대책공법으로 파일슬래브 공법이 제안되었다. 이 공법은 교대배면의 성토하중을 말뚝을 통하여 지지층으로 전달함으로써 연약지반의 측방유동을 효과적으로 방지할 수 있다. 연약지반상 파일슬래브공법으로 보강된 교대의 거동을 조사하기 위하여 현장계측을 수행하였다. 현장계측결과 파일슬래브공법은 교대뒷채움으로 인한 측방이동에 대하여 효과적으로 저항하는 것으로 나타났으며, 뒷채움으로 인한 성토하중은 말뚝을 통하여 지지층으로 전달됨을 알 수 있다. 이를 통하여 파일슬래브공법의 교대측방이동에 대한 억지효과를 확인할 수 있으며, 적용된 설계법의 합리성을 검증할 수 있다.

Interactive analysis of a building fame resting on pile foundation

  • Chore, H.S.
    • Coupled systems mechanics
    • /
    • 제3권4호
    • /
    • pp.367-384
    • /
    • 2014
  • The study deals with the physical modeling of a typical single storeyed building frame resting on pile foundation and embedded in cohesive soil mass using the finite element based software SAP-IV. Two groups of piles comprising two and three piles, with series and parallel arrangement thereof, are considered. The slab provided at top and bottom of the frame along with the pile cap is idealized as four noded and two dimensional thin shell elements. The beams and columns of the frame, and piles are modeled using two noded one dimensional beam-column element. The soil is modeled using closely spaced discrete linear springs. A parametric study is carried out to investigate the effect of various parameters of the pile foundation, such as spacing in a group and number of piles in a group, on the response of superstructure. The response considered includes the displacement at the top of the frame and bending moment in columns. The soil-structure interaction effect is found to increase the displacement in the range of 38 -133% and to increase the absolute maximum positive and negative moments in the column in the range of 2-12% and 2-11%. The effect of the soil- structure interaction is observed to be significant for the type of foundation and soil considered in this study. The results obtained are compared further with those of Chore et al. (2010), wherein different idealizations were used for modeling the superstructure frame and sub-structure elements (foundation). While fair agreement is observed in the results in either study, the trend of the results obtained in both studies is also same.

Calculation method and application of natural frequency of integrated model considering track-beam-bearing-pier-pile cap-soil

  • Yulin Feng;Yaoyao Meng;Wenjie Guo;Lizhong Jiang;Wangbao Zhou
    • Steel and Composite Structures
    • /
    • 제49권1호
    • /
    • pp.81-89
    • /
    • 2023
  • A simplified calculation method of natural vibration characteristics of high-speed railway multi-span bridge-longitudinal ballastless track system is proposed. The rail, track slab, base slab, main beam, bearing, pier, cap and pile foundation are taken into account, and the multi-span longitudinal ballastless track-beam-bearing-pier-cap-pile foundation integrated model (MBTIM) is established. The energy equation of each component of the MBTIM based on Timoshenko beam theory is constructed. Using the improved Fourier series, and the Rayleigh-Ritz method and Hamilton principle are combined to obtain the extremum of the total energy function. The simplified calculation formula of the natural vibration frequency of the MBTIM under the influence of vertical and longitudinal vibration is derived and verified by numerical methods. The influence law of the natural vibration frequency of the MBTIM is analyzed considering and not considering the participation of each component of the MBTIM, the damage of the track interlayer component and the stiffness change of each layer component. The results show that the error between the calculation results of the formula and the numerical method in this paper is less than 3%, which verifies the correctness of the method in this paper. The high-order frequency of the MBTIM is significantly affected considering the track, bridge pier, pile soil and pile cap, while considering the influence of pile cap on the low-order and high-order frequency of the MBTIM is large. The influence of component damage such as void beneath slab, mortar debonding and fastener failure on each order frequency of the MBTIM is basically the same, and the influence of component damage less than 10m on the first fourteen order frequency of the MBTIM is small. The bending stiffness of track slab and rail has no obvious influence on the natural frequency of the MBTIM, and the bending stiffness of main beam has influence on the natural frequency of the MBTIM. The bending stiffness of pier and base slab only has obvious influence on the high-order frequency of the MBTIM. The natural vibration characteristics of the MBTIM play an important guiding role in the safety analysis of high-speed train running, the damage detection of track-bridge structure and the seismic design of railway bridge.

CFRD의 최근 설계ㆍ시공기술 동향 (Recent Techniques for Design and Construction of CFRD)

  • 박동순;김형수;임정열
    • 지질공학
    • /
    • 제15권1호
    • /
    • pp.77-86
    • /
    • 2005
  • CFRD(Concrete fared Rockfill Dam)는 기존의 중심코어형 락필댐과 대별되는 우수한 구조적, 재료적 특성으로 현재 가장 널리 활용되는 댐 형식이다. 본 고에서는 그동안 이루어져온 기술의 축적을 바탕으로 CFRD의 설계와 시공에 있어 최근에 부각된 최신 기술들을 정리하여 향후 활용에 도움을 줄 수 있도록 하였다. 특별히 본 고에서는 최근 경험을 바탕으로 실무에서 적용되고 있는 연약한 암을 이용한 댐체 축조 사례, 대단히 큰 입경의 락필 재 대신 도입된 sand-gravel fill 댐에 대한 경험, plinth와face slab를 연결하기 위해 새롭게 채택된 연결 슬래브공법, 기존 댐의 증고사례, 역침투 현상, 댐 하류의 환경친화죤, 차수벽 슬래브의 두께와 철근비의 변화 추이, 충적층 기초의 처리, 최근 적용되기 시작한 curb element 공법등에 대한 간략한 기술적 동향을 고찰하여 관련 기술자들의 이해를 돕고자 하였다.

탄성지지된 3경간 연속 복합슬래브교량의 간단한 진동해석 (Simple Method of Vibration Analysis of Three Span Continuous Composite Slab Bridges with Elastic Intermediate Supports)

  • 한봉구;김덕현
    • 한국강구조학회 논문집
    • /
    • 제17권3호통권76호
    • /
    • pp.317-324
    • /
    • 2005
  • 본 연구에서는 3경간연속 탄성지지된 복합슬래브교량을 특별직교이방성 판이론을 응용하여 해석하였다. 불균등단면이나 임의의 경계조건을 가진 보나 타워구조물의 고유진동수를 계산하는 방법을 탄성지지된 3경간 연속 복합슬래브교량에 적용하여 연구하였다. 슬래브 상판은 특별직교이방성 판으로 취급하였다. 진동해석에 필요한 변위의 영향계수는 여러 가지 방법으로 구할 수 있으나 본 논문에서는 유한차분법을 사용하였다. 또한 휨강성에 대한 영향과 기초의 탄성계수에 대한 영향에 대하여 연구하였다.

Seismic performance of a 10-story RC box-type wall building structure

  • Hwang, Kyung Ran;Lee, Han Seon
    • Earthquakes and Structures
    • /
    • 제9권6호
    • /
    • pp.1193-1219
    • /
    • 2015
  • The purpose of this study is to evaluate the seismic performance of high-rise reinforced concrete (RC) box-type wall structures commonly used for most residential buildings in Korea. For this purpose, an analytical model was calibrated with the results of the earthquake simulation tests on a 1:5 scale 10-story distorted model. This calibrated model was then transformed to a true model. The performance of the true model in terms of the stiffness, strength, and damage distribution through inelastic energy dissipation was observed with reference to the earthquake simulation test results. The model showed high overstrength factors ranging from 3 to 4. The existence of slab in this box-type wall system changed the main resistance mode in the wall from bending moment to tension/compression coupled moment through membrane actions, and increased the overall resistance capacity by about 25~35%, in comparison with the common design practice of neglecting the slab's existence. The flexibility of foundation, which is also commonly neglected in the engineering design, contributes to 30~50% of the roof drift in the stiff direction containing many walls. The possibility of concrete spalling and reinforcement buckling and fracture under the maximum considered earthquake (MCE) in Korea appears to be very low when compared with the case of the 2010 Concepcion, Chile earthquake.

Vertical Z-vibration prediction model of ground building induced by subway operation

  • Zhou, Binghua;Xue, Yiguo;Zhang, Jun;Zhang, Dunfu;Huang, Jian;Qiu, Daohong;Yang, Lin;Zhang, Kai;Cui, Jiuhua
    • Geomechanics and Engineering
    • /
    • 제30권3호
    • /
    • pp.273-280
    • /
    • 2022
  • A certain amount of random vibration excitation to subway track is caused by subway operation. This excitation is transmitted through track foundation, tunnel, soil medium, and ground building to the ground and ground structure, causing vibration. The vibration affects ground building. In this study, the results of ANSYS numerical simulation was used to establish back-propagation (BP) neural network model. Moreover, a back-propagation neural network model consisting of five input neurons, one hidden layer, 11 hidden-layer neurons, and three output neurons was used to analyze and calculate the vertical Z-vibration level of New Capital's ground buildings of Qingdao Metro phase I Project (Line M3). The Z-vibration level under different working conditions was calculated from monolithic roadbed, steel-spring floating slab roadbed, and rubber-pad floating slab roadbed under the working condition of center point of 0-100 m. The steel-spring floating slab roadbed was used in the New Capital area to monitor the subway operation vibration in this area. Comparing the monitoring and prediction results, it was found that the prediction results have a good linear relationship with lower error. The research results have good reference and guiding significance for predicting vibration caused by subway operation.

공동주택 철근공사의 실태조사에 관한 연구 (A Study on the Actual Condition Survey of Apartment Rebar Work)

  • 이택운
    • 한국건축시공학회지
    • /
    • 제8권2호
    • /
    • pp.71-79
    • /
    • 2008
  • The rebar work is very related to the safety and durability of the building. Recently, the rebar work is produced some serious problems due to the lack of skillful crafts-man and the rising cost of rebar materials. Many papers have dealt with the rebar work of the manufacturing system in plants with a view to improvement those problems. But, the research on the rebar work of the manufacturing system in field is in a insignificant condition. This study presents the following improvement schemes as a result. First, the education strengthening for evaluation on practical affairs, second, the reinforcement of drawing & management in shop drawing and finally the simplification of apartment rebar work in slab. Also, this paper aims at advancing apartment rebar work by the actual condition survey in slab work. The further research will be needed about the whole structure parts such as foundation, wall, girder and rebar truss-deck plate as one of the improvement methods.