• Title/Summary/Keyword: form removal

Search Result 593, Processing Time 0.026 seconds

A study on material removal characteristics of MR fluid jet polishing system through flow analysis (유동해석을 통한 MR fluid jet polishing 시스템의 재료제거 특성 분석)

  • Sin, Bong-Cheol;Lim, Dong-Wook;Lee, Jung-Won
    • Design & Manufacturing
    • /
    • v.13 no.3
    • /
    • pp.12-18
    • /
    • 2019
  • Fluid jet polishing is a method of jetting a fluid to polish a concave or free-form surface. However, the fluid jet method is difficult to form a stable polishing spot because of the lack of concentration. In order to solve this problem, MR fluid jet polishing system using an abrasive mixed with an MR fluid whose viscosity changes according to the intensity of a magnetic field is under study. MR fluid jet polishing is not easy to formulate for precise optimal conditions and material removal due to numerous fluid compositions and process conditions. Therefore, in this paper, quantitative data on the factors that have significant influence on the machining conditions are presented using various simulations and the correlation studies are conducted. In order to verify applicability of the fabricated MR fluid jet polishing system by nozzle diameter, the flow pattern and velocity distribution of MR fluid and polishing slurry of MR fluid jet polishing were analyzed by flow analysis and shear stress due to magnetic field changes was analyzed. The MR fluid of the MR fluid jet polishing and the flow pattern and velocity distribution of the polishing slurry were analyzed according to the nozzle diameter and the effects of nozzle diameter on the polishing effect were discussed. The analysis showed that the maximum shear stress was 0.45 mm at the diameter of 0.5 mm, 0.73 mm at 1.0 mm, and 1.24 mm at 1.5 mm. The cross-sectional shape is symmetrical and smooth W-shape is generated, which is consistent with typical fluid spray polishing result. Therefore, it was confirmed that the high-quality surface polishing process can be stably performed using the developed system.

Rationale and criteria for excellent finishing (양호한 Finishing을 위한 이론적 근거 및 기준)

  • Ryu, Young-Kyu;Kim, Young-Joon
    • The korean journal of orthodontics
    • /
    • v.29 no.6 s.77
    • /
    • pp.637-648
    • /
    • 1999
  • Finishing is usually accomplished about four to seven months before the removal of orthodontic appliance in order to achieve ideal occlusion and excellent aesthetics. This process, called finishing, is the key to obtain excellent final results. Some of orthodontists believe it can be accomplished at the final stage of orthodontic treatment, and they complete it without their special rationale and criteria for finishing. However, it should be considered as a part of the total treatment plan from the beginning to end, and a guideline for finishing, which is based on rationale and criteria for the removal of orthodontic appliance, is needed to obtain the desired results. The guideline should include a checklist for finishing. This checklist is divided into four categories: occlusal, aesthetic, periodontal, and habitual factors. Occlusal fators include alignment, marginal ridge discrepancy, interproximal contact, anterior inclination, posterior inclination, over-jet over-bite, arch fen and functional occlusion. Aesthetic factors include gingival form, crown fen crown width, and crown length. Periodontal factors include root angulation, bone level, and black hole in periodontal factors. Habitual factors consist of mouth breathing, tongue position at rest, tongue thrust, lip biting, nail biting, and finger sucking

  • PDF

Evaluation of Treatment Efficiencies of Pollutants under Different Pollutant Fractions in Activated Sludge-Constructed Wetland System for Treating Piggery Wastewater (활성슬러지-인공습지 공법에 의한 돈사폐수처리시스템에서 오염물질의 분획별 정화효율 평가)

  • Kim, Seong-Heon;Seo, Dong-Cheol;Park, Jong-Hwan;Lee, Choong-Heon;Choi, Jeong-Ho;Kim, Hong-Chul;Ha, Yeong-Rae;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.31 no.4
    • /
    • pp.344-350
    • /
    • 2012
  • BACKGROUND: To design and develop a constructed wetland for effective livestock wastewater treatment, it is necessary to understand the removal mechanisms of various types of pollutants in constructed wetlands. The objective of this study was to evaluate the treatment efficiency of pollutants under different types of fraction in constructed wetland system for treating piggery wastewater. METHODS AND RESULTS: The piggery wastewater treatment plant that consisted of activated sludge tank, aerobic and anaerobic beds was constructed. The concentration of COD(Chemical oxygen demand) in effluent by fraction was 71.5 mg/L for soluble COD, 142 mg/L insoluble COD. The concentration of SS(Suspended solid) in effluent by existing form was 102 mg/L for volatile SS, 15.5 mg/L for fixed SS. The concentration of T-N(Total nitrogen) and T-P(Total phosphorus) in effluent by existing form were 12.8 mg/L and 3.05 mg/L for dissolved form, 35.0 mg/L and 1.93 mg/L for suspended form. The removal efficiencies of COD, SS, T-N and T-P in hot season(summer and autumn) were higher than those in cold season(spring and winter). The removal efficiencies of COD, SS, T-N and T-P in effluent were 98.0, 99.0, 98.2 and 99.2% for all seasons, respectively. CONCLUSION(S): The results indicated that removal types of pollutants were insoluble COD(ICOD), volatile SS(VSS), dissolved T-N(DTN) and dissolved T-P(DTP) in constructed wetlands for treating piggery wastewater.

Dry cleaning for metallic contaminants removal after the chemical mechanical polishing (CMP) process (Chemical Mechnical Polishing(CMP) 공정후의 금속오염의 제거를 위한 건식세정)

  • 전부용;이종무
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.2
    • /
    • pp.102-109
    • /
    • 2000
  • It is difficult to meet the cleanliness requirement of $10^{10}/\textrm{cm}^2$ for the giga level device fabrication with mechanical cleaning techniques like scrubbing which is widely used to remove the particles generated during Chemical Mechanical Polishing (CMP) processes. Therefore, the second cleaning process is needed to remove metallic contaminants which were not completely removed during the mechanical cleaning process. In this paper the experimental results for the removal of the metallic contaminants existing on the wafer surface using remote plasma $H_2$ cleaning and UV/$O_3$ cleaning techniques are reported. In the remote plasma $H_2$ cleaning the efficiency of contaminants removal increases with decreasing the plasma exposure time and increasing the rf-power. Also the optimum process conditions for the removal of K, Fe and Cu impurities which are easily found on the wafer surface after CMP processes are the plasma exposure time of 1min and the rf-power of 100 W. The surface roughness decreased by 30-50 % after remote plasma $H_2$ cleaning. On the other hand, the highest efficiency of K, Fe and Cu impurities removal was achieved for the UV exposure time of 30 sec. The removal mechanism of the metallic contaminants like K, Fe and Cu in the remote plasma $H_2$ and the UV/$O_3$ cleaning processes is as follows: the metal atoms are lifted off by $SiO^*$ when the $SiO^*$is evaporated after the chemical $SiO_2$ formed under the metal atoms reacts with $H^+ \; and\; e^-$ to form $SiO^*$.

  • PDF

Effect of Unexpected Foaming Incident on Nitrogen Removal in a Vertical Subsurface Wetland (수직지하 흐름형 습지에서 거품발생이 질소제거에 미치는 영향)

  • Cheng, Jing;Guerra, Heidi B.;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.21 no.4
    • /
    • pp.334-343
    • /
    • 2019
  • A lab-scale vertical flow subsurface (VFS) wetland composed of three parallel columns with polypropylene synthetic fiber as main substrate was operated. Piggery stormwater diluted from swine excreta was fed to the wetland on the basis of three different hydraulic regimes or hydraulic retention time (HRT) of 2, 4, and 8 days with daily internal recirculation. Then, monitoring of common water quality parameters was carried out. Unexpectedly, an increase of effluent COD concentration accompanying the appearance of foams was observed during a distinct period in the wetland with HRT 2, 4, and 8 days, successively. Subsequently, a series of experiments was conducted to investigate the origin of the foams. Foams and the increase of COD concentration were found to be induced by the release of organic matter from the synthetic polypropylene fiber which was fed with piggery stormwater. Meanwhile, nitrogen removal was found to be enhanced during a period which overlapped the distinct foaming period signifying that foaming played two important functions in biological nitrogen removal. Foams which form rapidly and then burst easily could hold up and then release oxygen for nitrification. Foams which contain organic surfactants could serve as carbon sources for denitrification as well. Hence, nitrogen removal was enhanced during the foaming stage. After that, COD concentration decreased slowly to a level prior to the foaming stage, and nitrogen removal efficiency declined as well.

Comparative Studies on Soot Oxidation by Nitrogen Dioxide and Ozone

  • Purushothama, C.;Chen, Xin-Hong;Li, Ming-Wei;Chae, Jae-Ou;Sim, Ju-Hyen
    • 한국연소학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.117-121
    • /
    • 2006
  • Non-thermal plasma technology has many applications in various areas. One of the applications is regenerating diesel particulate filter (DPF). DPF is a widely applied device to control the particulate emission of diesel engines. But it needs periodic removal of clogged soot for the smooth running of engine. Conventional high-temperature removal processes easily leads to the breakage of DPF. Herein, low-temperature plasma formed in a dielectric barrier discharge (DBD) reactor was used to form active oxidants such as ozone and nitrogen dioxide. Experimentally, the effects of discharge power and frequency on the performance of DBD reactor were studied. Two oxidants, $O_3$ and $NO_2$, were synthesized and used for incinerating soot in the used DPF. Performances of the two oxidants on the reduction of soot were compared, and it was found that $NO_2$ is more effective than $O_3$ for getting rid of soot

  • PDF

Biofilter를 이용한 폐가스중의 styrene 제거

  • Gang, Yeom-Seok;Hwang, Jae-Ung;Jang, Seok-Jin;Park, Seong-Hun
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.394-397
    • /
    • 2000
  • Lab-scale biofilter was evaluated for the removal of styrene from a waste gas stream. Compost and polyurethane form were used as packing material (50 : 50) and activated sludge from a wastewater treatment plant was innoculated initially. Nitrogen limitation was observed during the biofilter operation and nitrogen source should be properly supplemented. When ammonium sulfate is used as N-source. 200mg carbon was removed for each mg of nitrogen. The effects of the volumetric styrene loading on the styrene elimination capacity (EC) and the removal efficiency (RE) was also tested. The results showed $EC_{max}$ was 4.8kg $C/m^3{\cdot}day$ and above RE 95% was achieved at EBRT 1min.

  • PDF

The Utilization of Waste Seashell for High Temperature Desulfurization

  • Kim, Young-Sik;Hong, Sung-Chul
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.2
    • /
    • pp.136-140
    • /
    • 2010
  • The integrated gasification combined cycle (IGCC) is one of the most promising proposed processes for advanced electric power generation that is likely to replace conventional coal combustion. This emerging technology will not only improve considerably the thermal efficiency but also reduce or eliminate the environmentally adverse effects normally associated with coal combustion. The IGCC process gasifies coal under reducing conditions with essentially all the sulfur existing in the form of hydrogen sulfide ($H_2S$) in the product fuel gas. The need to remove $H_2S$ from coal derived fuel gases is a significant concern which stems from stringent government regulations and also, from a technical point of view and a need to protect turbines from corrosion. The waste seashells were used for the removal of hydrogen sulfide from a hot gas stream. The sulphidation of waste seashells with $H_2S$ was studied in a thermogravimetric analyzer at temperature between $600^{\circ}C$ and $800^{\circ}C$. The desulfurization performance of the waste seashell sorbents was experimentally tested in a fixed bed reactor system. Sulfidation experiments performed under reaction conditions similar to those at the exit of a coal gasifier showed that preparation procedure and technique, the type and the amount of seashell, and the size of the seashell affects the $H_2S$ removal capacity of the sorbents. The pore structure of fresh and sulfided seashell sorbents was analyzed using mercury porosimetry, nitrogen adsorption, and scanning electronmicroscopy.

Automatic Generation of Explanatory 2D Vector Drawing from 3D CAD Data for Technical Documents (기술문서 작성을 위한 3 차원 CAD 데이터의 도해저작 알고리즘)

  • Shim H.S.;Yang S.W.;Choi Y.;Cho S.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.177-180
    • /
    • 2005
  • Three dimensional shaded images are standard visualization method for CAD models on the computer screen. Therefore, much of the effort in the visualization of CAD models has been focused on how conveniently and realistically CAD models can be displayed on the screen. However, shaded 3D CAD data images captured from the screen may not be suitable for some application areas. Technical document, either in the paper or electronic form, can more clearly describe the shape and annotate parts of the model by using projected 2D line drawing format viewed from a user defined view direction. This paper describes an efficient method for generating such a 2D line drawing data in the vector format. The algorithm is composed of silhouette line detection, hidden line removal and cleaning processes.

  • PDF

Successful Removal of a Cardiac Fibroma in Infant (신생아에서 발생한 심장 섬유종의 외과적 치료 -1례 보고-)

  • Kim, Si-Ho;Jo, Beom-Gu;Hong, Yu-Seon
    • Journal of Chest Surgery
    • /
    • v.28 no.5
    • /
    • pp.491-494
    • /
    • 1995
  • A fibroma arising in the right ventricle outflow tract of a 14 month-old infant was successfully removed. The patient was first seen because of shortness of breath and tachycardia. Pertinent clinical and laboratory findings included a grade II/VI systolic murmur, blood pressure of 120/60 mmHg, slight cardiomegaly on chest X-ray, a mass obstructing the outflow tract of the right ventricle on echocardiography and magnetic resonance imaging. On october 30,1992, under cardiopulmonary bypass, a 4cm x 3cm x 3cm tumor was resected from the right ventricular outflow tract, together with a portion of the ventricular wall. Histologically, it was diagnosis as a fibroma. The patient was sent home on the 6th postoperative day following an uneventful recovery form the operation. Although cardiac fibroma is the second most common cardiac tumor in infancy and childhood, it is usually found in the left ventricle and one arising in the right ventricle is considered rare. Although it is a benign tumor, it could produce a severe cardiac dysfunction and even sudden death, depending on its size and location. With the advance in diagnostic techniques and operative management, there is a renewed interest in the early detection and operative removal of these tumors. The case herein presented is the first such case successfully managed and reported in the Korean literature.

  • PDF