• Title/Summary/Keyword: foreign-body

Search Result 942, Processing Time 0.021 seconds

Dynamic Problem in Removal of a Bronchial Foreign Body (a injection needle) (기관지이물(주사침) 적출의 역학적 문제)

  • 노관택;전병두
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.3.1-3
    • /
    • 1972
  • Authors experienced a bronchial foreign body-an injection needle at the proximal portion of reft main bronchus of a 5 years old female child. An interesting dynamic problem encountered during the removal. A human bronchial specimen lodging the foreign body will be demonstrated with consideration of the dynamic factors.

  • PDF

A Case of Esophageal Foreign body retained for 6 Months (6개월간 체류한 식도이물 1례)

  • 성창섭;김성식;유지훈
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.8.1-8
    • /
    • 1981
  • Foreign body in esophagus is not uncommon in the field of otolaryngology. There are many reports about it with recent advanced development of esophagobronchology. The authors have recently experienced an interesting case of foreign body retained in second constrictor portion of esophagus, which had been perforated the anterior wall of esophagus and then pierce the trachea.

  • PDF

A Case of Unexpected Clinostomum complanatum Infection Initially Presenting as Foreign Body in Pharynx

  • Kim, Hyunjung;Cho, Sung-Weon;Oh, Harim;Byeon, Hyung Kwon
    • Parasites, Hosts and Diseases
    • /
    • v.57 no.2
    • /
    • pp.175-177
    • /
    • 2019
  • A 46-year old man visited our outpatient clinic with complaint of foreign body sensation in throat after consuming raw freshwater fish 5 days ago. Laryngoscopic examination revealed a motile worm attached on posterior pharyngeal wall. The worm was removed using biopsy forceps under transnasal endoscopy and evidently identified as Clinostomum complanatum after microscopic examination. Patient's subjective foreign body sensation of throat and hyperemia of laryngeal mucosa remained for approximately 2 weeks post-removal, which were eventually resolved after administration of non-steroidal anti-inflammatory drug and anti-refluxant drug for 2 weeks. Treatment was ended at three weeks since the first visit. C. complanatum infections in humans are rare, and only four cases have been reported in Korea. Symptoms resembling pharyngitis or laryngitis occurs by consumption of raw, infected freshwater fish and treatment is done by mechanically removing the parasite.

A Case of Bilateral Bronchial Foreign Body

  • Sungchul, Ko;Jaeha, Lee;Sothearith, Loek;Ki Nam, Park
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.33 no.3
    • /
    • pp.179-182
    • /
    • 2022
  • Foreign body (FB) aspiration remains a serious health problem, particularly in children. The complications due to occlusion by FB or related to procedures for removal can lead to morbidity and mortality. Most of the FBs are located in the unilateral bronchus, however, the organic FB can be multiple or bilaterally located when children chewed the FB. Here, we present a case of successful retrieval of bilateral bronchial FBs. Preoperatively, FB in the left main bronchus was diagnosed, however, FB of the right upper bronchus was not definitive on X-ray and CT scan. During the rigid bronchoscopy, occult FB in the right upper bronchus was detected and successfully removed.

Arthroscopic Retrieval Analysis for Intra-articular Foreign Body of the Knee Joint (슬관절내 이물질에 대한 관절경적 제거술식의 분석)

  • Lee, Byung-Ill;Choi, Hyung-Suk;Jo, Joo-Hyoung;Kwon, Sai-Won
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.211-216
    • /
    • 2008
  • Purpose: The frequency of foreign body in the knee joint is not as high, but it sometimes required wide or multiple arthrotomy in order to remove, which can baffle the surgeon in some ways. Our study is to evaluate for effectiveness of arthroscopic retrieval for intra-articular foreign body in the knee joint. Materials and Methods: The 22 patients(16 males, 6 females) had received arthroscopic foreign body retrieval in the knee joint from March 1983 to September 2006. The causes of foreign bodies of the knee joint were 7 of trauma (31.9%) related cases, 13 of surgery related cases (59.0%), 2 found during follow up after operation (8.1%) in pathologies of foreign body. Results: There were 15 of metal showed the most percentage (68.1%), 7 of non-metal (31.9%) in types of foreign bodies, and others included bullet, suture material, pencil lead, broken wire etc. All cases were used by arthroscopic techniques. All foreign bodies were removed easily and were showed no complication such as postoperative joint stiffness. Conclusion: Arthroscopic foreign body retrieval in the knee joint is effective surgery in terms of easy access to foreign body and less postoperative complication.

  • PDF

Evaluation of Experimentally Induced Lumbar Spinal Cord Injury by Somatosensory Evoked Potentials(SEPs) in Dogs (개에서 Somatosensory Evoked Potentials (SEPs)을 이용한 척수기능장애의 평가)

  • Lee, Joo-Myoung;Jeong, Seong-Mok;Kweon, Oh-Kyeong;Nam, Tchi-Chou
    • Journal of Veterinary Clinics
    • /
    • v.18 no.4
    • /
    • pp.315-323
    • /
    • 2001
  • Changes in somatosensory evoked potentials (SEPs) which accompanied by insertion of foreign body in spinal canal were evaluated with clinical signs and positive contrasted myelography in dogs. Foreign bodies occupied 20∼50% of spinal canal. Foreign bodies occupying about 50% of spinal canal were inserted into the animals of group II and III for 1 week and 2 days, respectively. Foreign bodies occupying about 20% of spinal canal were inserted into the animals of group IV, V, and for 1 week, 2 days, and 8 weeks, respectively. in group I (control group), sham operation (lateral laminectomy) was performed. Group III, IV and V did not severely affect on SEPs latencies and clinical signs. Group VI affects on SEPs latencies but not on clinical signs. After foreign body removal, SEPs latencies showed similar recovery patterns with clinical signs. However, group II induced severe abnormalities in SEPs latencies and clinical signs. In group III, IV and V, thoracic potentials (TN1) were abnormally recorded after foreign body insertion and firstly/normally recorded on the 6th 9.5th and 3.5th day after foreign body (removal following) insertion. In group VI, TN1 was abnormally recorded after foreign body insertion and firstly recorded on the 7.7th day and normally recorded on 34th day after foreign body insertion. In group I, TN1 was not recorded from the 3rd day after foreign body insertion and until the 8th week after foreign body removal. In group I, TN1 was firstly recorded on the 1st day after laminectomy.

  • PDF

Evaluation of Customer Satisfaction on the Internee Apparel Shopping Mall - Focused on Apparel Sizing System - (인터넷 의류 쇼핑몰에 대한 소비자 만족도 평가 -의류 치수체계를 중심으로 -)

  • 이경화;조재희
    • Journal of the Korean Society of Costume
    • /
    • v.51 no.3
    • /
    • pp.129-139
    • /
    • 2001
  • The purpose of this study is to suggest the standard size specification of the apparel item as finding out apparel products'sizing problem in the domestic and foreign interned shopping malls. Though that, to suggest basic data of web page offered sizing system given to consumer higher satisfaction and based on ISO (International Organization For Standardization), domestic industry standard and service related size. The summarized findings are as follow. 1. The result of size description research, the size description system between internet site were very different, in addition in the department shopping malls it was different by manufacturing industry. Also in domestic and foreign shopping malls, It was not correspond to ISO and domestic industry standard, used Numeric and Alphabetical size. In the foreign shopping mall it distinguish body type and age group. 2. The result of consumer's satisfaction, the superior fashion malls were Samsung, LG, Fashionpia in the domestic shopping mall, were Gap, JCPenny, Jcrew in the foreign shopping malls. In the total group, 1-5 grades were ranked in the foreign shopping malls. 3. Satisfaction of the foreign fashion mall was higher than that of the domestic fashion malls. Exactly, foreign fashion mall described size chart, size description, product size and body size measuring method but domestic fashion malls didn't describe that. Domestic fashion malls need sizing system development given to consumer higher satisfaction. In addition sizing system based on ISO and domestic industry standard and subdivided to body type and ale group must be studied. Aloe, fashion information, coordination information and product explanation must be reinforced.

  • PDF

Successful removal of a foreign body by endoscopic balloon dilatation at the colonic stricture

  • Im, Chang Jo;Na, Ji Hoon;Kim, Hyun Sik;Ha, Sung Sam;Lim, Yoo Li;Lee, Ji Hyeon;Choi, Hee Kyoung;Kim, Hee Man
    • Journal of Yeungnam Medical Science
    • /
    • v.33 no.1
    • /
    • pp.29-32
    • /
    • 2016
  • Most ingested foreign bodies pass readily throughout intestinal tract if they reach the stomach. In some cases, foreign bodies may be impacted behind a luminal constriction but are rare in colon. Here, we report the case of a 59-year-old man who did laparoscopic anterior resection due to sigmoid colon cancer 2 years ago and ischemic colitis was repeated on the anastomosis site. He initially presented with symptoms of abdominal pain 3 months before and melena 1 day before admission. Abdomen computerized tomography showed a 3.2 cm segment of luminal narrowing of the proximal colon involving upstream foreign material stasis. Sigmoidoscopic approaches revealed near complete obstruction on the anal verge of 20 cm and scope passing failed. Balloon dilatations were done on the obstruction site four times all and a foreign body impacted above the obstruction site was removed by an alligator without any complications. The foreign body removed looks like plastic or a shell, about 20 mm in size.

Gastrotomy Approach Retrieval of Esophageal Foreign Body using Long Forceps Technique in Five Dogs (위 절개술 접근과 긴 겸자를 이용한 식도 내 이물 제거 5례)

  • Yoon, Hun-Young;Kang, Myung-Gon;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.26 no.6
    • /
    • pp.628-631
    • /
    • 2009
  • Five dogs presented to the Veterinary Medical Teaching Hospital of the Konkuk University and Hangang Animal Hospital with a history of foreign body ingestion. On physical examination, five dogs showed lethargy, anorexia, or vomiting. Plain radiographs revealed that radiopaque foreign bodies lodged in the heart base or caudal thoracic esophagus. Positive contrast esophagogram revealed that large foreign bodies severely expanded the esophagus and there was no evidence of leakage of the contrast agent from the esophagus into the thoracic cavity. Gastrotomy for retrieval of esophageal foreign bodies using long forceps technique was performed. Esophageal foreign bodies were successfully retrieved in all dogs. The follow-ups were completed 10 days to 2 years after surgery. The follow-up information was based on physical examination by veterinarians and telephone interview with owners. The owners reported that there was no evidence of complications related to surgery such as vomiting, regurgitation, dysphagia, gagging, hyper-salivation, or anorexia in all dogs.

A Case of Bronchial Foreign Body Misdiagnosed as Bronchial Asthma (기관지천식으로 오인된 기관지내 이물 1예)

  • Lee, Byoung Jun;Lee, Young Woo;Jung, Jae Woo;Shin, Jong Wook;Kim, Jae Yeol;Park, In Won;Choi, Byoung Whui
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.5
    • /
    • pp.484-488
    • /
    • 2004
  • In adults, aspiration of foreign bodies into tracheobronchus is sometimes presented atypically, mimicking chronic pulmonary diseases such as bronchial asthma, pneumonia, or empyema, especially without notice of aspiration or choking. In such cases, diagnosis and adequate treatments are often delayed. Suspicion of foreign body aspiration and computed tomography and bronchoscopic examination make correct diagnosis more early. We report a case of bronchial foreign body, which had been misdiagnosed as bronchial asthma with wheezing in the whole lung filed, and reversible airway obstruction in the spirometry.