시험공간에 강제환기를 고려한 냉방부하의 실증실험 및 시뮬레이션 (Verification Experiment and Simulation of Cooling Load for a Test Space with Forced Ventilation)

  • 김동혁;유호선;홍희기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.217-222
    • /
    • 2005
  • Building energy consumption according to the ventilation has been considered to be an important subject. The purpose of this study is to investigate the cooling loads in a test space with a forced ventilating system. In the test space, on/off controlled air-conditioning and forced ventilating facility were operated between 8:30 to 21:00 during 4 days and some important data like temperatures and energy consumption were measured to obtain actual cooling loads. The simulation was carried out in a mode of temperature level control using a TRNSYS 15.3 with a precisely measured air change amount and performance data of air-conditioner. Cooling loads including sensible and latent were compared between by experiment and by simulation. Both of cooling loads associated with ventilation show a close agreement within an engineering tolerance.

  • PDF

증기터빈 강제냉각 장치의 설계 및 적용 (Design and Application of Forced Cooling System in Steam Turbine)

  • 김효진;류승우;강용호
    • 한국정밀공학회지
    • /
    • 제15권9호
    • /
    • pp.25-32
    • /
    • 1998
  • The forced cooling system is designed to shorten the overhaul time of steam turbine, which is important in view of economic concern of utility companies, Forced cooling of the hot turbine is achieved by suction of air flow into the turbine after the turbine shuts down. The heat transfer process by suction of air flow can cause thermal stress due to the thermal gradients. In this paper, the analysis of heat transfer is performed to calculate the air flow rate. Based on the prediction of cyclic fatigue damage and the experience, the cooling equipment is designed for shortening the cooling time of steam turbine.

  • PDF

자연대류와 강제대류에서 펠티에 소자를 이용한 내부터널 구조를 가지는 히트싱크에 관한 연구 (A Study on the Heat Sink with internal structure using Peltier Module In the Natural and Forced Convection)

  • 이민;김태완
    • 한국산학기술학회논문지
    • /
    • 제15권7호
    • /
    • pp.4072-4080
    • /
    • 2014
  • 펠티에 소자는 전자부품이나 장비에서 발생하는 열을 냉각하기 위한 방법으로 많이 사용되고, 히트싱크는 이러한 열을 외부로 방출하기 위한 방법으로 많이 사용되고 있다. 본 연구에서는 내부터널의 형상을 가지는 히트싱크에 대한 냉각 및 히팅성능을 자연대류와 강제대류 상태에서 열전달 특성에 대하여 고찰하였다. 또한, 시간에 따른 히트싱크의 열전달 특성 및 온도분포의 변화에 따른 실험을 수행하였고, 자연대류와 강제대류에 따른 히트싱크의 열전달 특성, 온도분포의 변화를 실험을 통해 비교 연구 하였다. 냉각 실험에서 A형상 및 B형상 냉각 핀 히트싱크는 자연대류보다는 강제대류에서 온도가 더 감소하는 것을 알 수가 있었고, 강제대류와 자연대류에서 A, B형상 모두 $-15^{\circ}C$까지 떨어지는 것을 알 수 있었다. 전압이 증가 할수록 강제대류와 자연대류 상태에서 A, B형상 냉각 핀 히트싱크 모두 온도가 감소하였다. 히팅실험에서 A형상 및 B형상 냉각 핀 히트싱크는 자연대류보다는 강제대류에서 온도가 더 증가하는 것을 알 수가 있었고, 강제대류와 자연대류에서 전압이 13V일 때, A형상 냉각 핀 히트싱크는 전압이 $150^{\circ}C$, 강제대류에서 B형상 냉각 핀 히트싱크는 $145^{\circ}C$까지 증가하였다. 전압이 증가할수록 강제대류와 자연대류 상태에서 A, B형상 냉각 핀 히트싱크 모두 온도가 증가하였다.

강제대류 및 핵비등영역에 있어서 액적유량과 분무냉각 열전달의 상관관계에 관한 연구 (Correlation of Droplet Flow Rate and Spray Cooling Heat Transfer in Forced Convection and Nucleate Boiling Region)

  • 김영찬
    • 한국분무공학회지
    • /
    • 제13권3호
    • /
    • pp.143-148
    • /
    • 2008
  • In the present study, the correlation between the Nusselt number and Reynolds number was developed for forced convection and nucleate boiling region in spray cooling. Also the effect of droplet subcooling on spray cooling heat transfer was investigated. Full cone spray nozzles were employed for spray cooling experiment, and water and FC-77 were used for developing the correlation. From the experimental results, the correlation between the Nusselt number and Reynolds number based on droplet-flow-rate was developed. The correlation shows good predictions with ${\pm}30%$ error for water and FC-77.

  • PDF

공동주택 거실의 냉방방식에 따른 열환경 특성에 관한 연구 (A Study on the Characteristic of the Thermal Environment in the Cooling System at the Apartment)

  • 이무진
    • 한국주거학회논문집
    • /
    • 제10권4호
    • /
    • pp.111-120
    • /
    • 1999
  • The purpose of this study is to evaluate the efficiency of the thermal environment created by the cooling system at the apartment that combines the forced convection cooling(the system reducing humidity from room) with the floor cooling radiation which uses the floor panel from floor heating system, a general residential heating system in Korea. In this study, the combined cooling system in which air supply, spurt temperature difference and interior draft are reduced, is compared with the existing forced convection cooling system. To identify the effect of the comparison concretely, a comparative experiment is carried out on tour conditions, ie, convection cooling, floor radiation convection cooling and floor radiation cooling. Through it the characteristical thermal environment formed within the model room is analyzed, and the conveying system of compressed floor chill and condensation problem are reviewed.

  • PDF

압전 액츄에이터를 이용한 열전냉각 시스템 성능 향상에 관한 연구 (A Study on Enhancement of Thermoelectric Cooling System Performance by Piezoelectric Actuator)

  • 양호동;윤희성;오율권
    • 한국안전학회지
    • /
    • 제24권6호
    • /
    • pp.13-19
    • /
    • 2009
  • The thermoelectric cooling system consisted of the thermoelectric module, a heat sink and a cooling fan, respectively. Also, the piezoelectric actuator was applied to improve the performance of thermoelectric cooling system and investigate the heat transfer phenomenon. The temperature distribution of test section was measured to investigate cooling characteristics of thermoelectric cooling system. The flow phenomenon of test section was visualized using visualization device. When the piezoelectric actuator was applied to the heat transfer process of thermoelectric cooling system, acoustic streaming was occurred in test section. The acoustic streaming was occurred forced convection flow, and was regularly formed the temperature distribution in test section. The results clearly show that the acoustic streaming is one of the prime effects to enhance the convection heat transfer and can enhance the performance of thermoelectric cooling system.

강제환기가 적용된 시험공간에서 냉난방부하의 시뮬레이션 및 실증실험 (Simulation and Verification Experiment of Cooling and Heating Load for a Test Space with Forced Ventilation)

  • 김동혁;홍희기;유호선;김욱중
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.947-954
    • /
    • 2006
  • Building energy consumption according to the ventilation has been considered to be an important subject. The purpose of this study is to investigate the cooling and heating loads in a test space with a forced ventilating system. In the test space, on/off controlled air-conditioning and forced ventilating facility were operated between 8 : 30 to 21 : 00 during 4 days and some important data like temperatures and energy consumption were measured to obtain actual thermal loads. The simulation was carried out in a mode of temperature level control using a TRNSYS 15.3 with a precisely measured air change amount and performance data of air-conditioner. Heating load and cooling load including sensible and latent were compared between by experiment and by simulation. Both of thermal loads associated with ventilation show a close agreement within an engineering tolerance.

예냉 처리가 치콘의 MA 저장성에 미치는 영향 (Effect of Precooling Treatments on the Storability of Chicon during MA Storage)

  • 정현진;서현택;최인이;유태종;손진성;원재희;김일섭;강호민
    • 생물환경조절학회지
    • /
    • 제19권4호
    • /
    • pp.360-365
    • /
    • 2010
  • 본 연구는 예냉처리가 치콘의 MA저장에 미치는 영향을 알아보고자 실시하였다. 치콘의 예냉은 강제송풍 예냉처리에 빠르게 진행되어 품온이 예냉 목표 온도인 $2{\pm}1^{\circ}C$까지 저하되는데 소요시간이 강제송풍예냉이 자연통풍식의 1/6 수준이었다. 반냉각시간은 자연예냉이 3시간 21분, 강제통풍식이 1시간 17분이었다. 저장중 치콘의 생체중은 $5^{\circ}C$$10^{\circ}C$ 저장에서 모든 처리구가 0.5% 미만의 감소로 극히 적었으며 예냉시간이 짧았던 강제송풍예냉이 가장 높게 유지되었다. 저장중 포장재내 산소와 이산화탄소 그리고 에틸렌의 농도변화는 $5^{\circ}C$에 비해 $10^{\circ}C$에서 변화폭이 컸다. 예냉에 의한 호흡 억제 효과는 $5^{\circ}C$에서 나타나지 않았으나, $10^{\circ}C$에서 저장 9일 이후 대조구보다 낮은 이산화탄소와 높은 산소 농도로 확인되었다. 에틸렌은 예냉처리구가 저장 3일까지 대조구에 비해 다소 낮았으나 저장 6일부터는 처리간에 차이를 보이지 않았다. 저장 15일째 조사한 외관상 품질은 $5^{\circ}C$$10^{\circ}C$ 모두에서 대조구에 비해 예냉처리구에서 높게 유지되었는데, 예냉처리별로는 예냉기간이 휠씬 짧았던 강제송풍예냉에서 품질저하가 자연예냉 보다 더 컸다. 이는 6.0m/sec의 강한 송풍으로 치콘의 외옆 일부가 물리적 상처를 입었기 때문이라 판단되어 송풍속도 등에 대한 세밀한 추가 실험이 요구된다.

The Optimized Design of a NPC Three-Level Inverter Forced-Air Cooling System Based on Dynamic Power-loss Calculations of the Maximum Power-Loss Range

  • Xu, Shi-Zhou;He, Feng-You
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1598-1611
    • /
    • 2016
  • In some special occasions with strict size requirements, such as mine hoists, improving the design accuracy of the forced-air cooling systems of NPC three-level inverters is a key technology for improving the power density and decreasing the volume. First, a fast power-loss calculation method was brought. Its calculation principle introduced in detail, and the computation formulas were deduced. Secondly, the average and dynamic power losses of a 1MW mine hoist acting as the research target were analyzed, and a forced-air cooling system model based on a series of theoretical analyses was designed with the average power loss as a heat source. The simulation analyses proves the accuracy and effectiveness of this cooling system during the unit lifting period. Finally, according to an analysis of the periodic working condition, the maximum power-loss range of a NPC three-level inverter under multi cycle operation was obtained and its dynamic power loss was taken into the optimized cooling system model as a heat source to solve the power device damage caused by instantaneous heat accumulation. The effectiveness and feasibility of the optimization design based on the dynamic power loss calculation of the maximum power-loss range was proved by simulation and experimental results.

수확 후 전처리에 의한 고랭지 배추 '춘광' 품종의 저온 저장 중 품질 변화에 대한 비교 (Comparison of the Quality of Highland-Grown Kimchi Cabbage 'Choon Gwang' during Cold Storage after Pretreatments)

  • 배상준;엄향란;김병섭;윤정로;홍세진
    • 원예과학기술지
    • /
    • 제33권2호
    • /
    • pp.233-241
    • /
    • 2015
  • 강원도 강릉에 위치한 고랭지 지역에서 재배된 배추 '춘광' 품종은 수확 직후 차압식예냉, 통풍식예냉, 예건 처리를 하였고, 전처리 후 각각 처리에 대해 0.02mm HDPE film으로 liner 처리 유무에 따라 분류한 다음 $2^{\circ}C$에 저장을 하면서 품질 조사를 실시하였다. 저장 중 무게 손실은 liner 처리구에서 차압예냉이 3% 미만의 손실률을 보였고, 통풍예냉 또한 4% 미만의 손실률을 보였다. 그러나 liner 무처리 구에서는 통풍예냉이 10% 미만의 손실률을 보였고, 차압예냉의 경우 15% 이상으로 가장 많은 손실률을 보였으며, 오히려 대조구가 손실률이 가장 적었다. 가용성고형물의 경우 $2-4^{\circ}brix$ 정도로 나타났으며, 색도는 CIE $L^*$ 값은 50 내외로 큰 차이를 보이지 않았고, hue angle 값은 조금씩 감소하였으나 $120{\pm}2^{\circ}C$ 사이 녹색의 범위 안에 분포하여 색의 변화에 대한 차이는 없었다. Chroma 값의 경우에도 28-32 사이에 분포하였다. 경도는 22N 정도로 나타났으며, 처리에 따른 유의적 차이는 보이지 않았다. 관능 평과 결과, 외관과 아삭거림 정도의 경우 차압예냉을 실시한 후 liner를 적용한 배추에서 가장 좋은 결과가 나타났으며, 나머지 항목에서는 유의적 차이가 없었다. 저장 6주 경과 후 liner 무처리구에서 외관이 많이 손상되었고, 7주 경과 후 liner 처리구에서 통풍예냉과 예건에서 내부 갈변이 심하게 발생하였다.