• Title/Summary/Keyword: force margin

Search Result 83, Processing Time 0.025 seconds

Characteristics on the Motion of Purse Seine(I) -The Sinking Behaviour of Model Purse Seine by Different Netting Material- (건착망의 운동특성(I) -그물감이 다른 건착망의 침강거동-)

  • Kim, Suk-Jong;ImaiI, Takehiko;Park, Jeong-Sik
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.4
    • /
    • pp.362-371
    • /
    • 1995
  • This study describes with the sinking behaviour for the purse seine. The experiment was carried out using three model purse seines of knotless netting. The nettings were woven in same leg length(10.5mm) of polypropylene 170 denier, polyamide 210 denier and polyester 250 denier two thread ply twine, each of the seines were named PP seine, PA seine and PES seine. Dimension of Purse seine models were 420cm for corkline and 85cm for seine depth, each models rigged 65.8g, 50.6g and 35.8g(weight in water) of lead for a leadline, seine models will have the same weight in water. Experiments carried out in the observation channel in a flume tank under still water conditions. Sinking motion was recorded by the one set of TV-camera for VTR, and reading coordinate carried out by the video digitization system. The results obtained were as follows: 1) Netting bundle for PP seine was existence on the surface of the water, spread out a netting by sinking force of sinkers. 2) Netting bundle for PES seine was existence in the middle of corkline and leadline. 3) Average sinking speed of seine margin was fastest for 10.7cm/s of PP seine, followed by 9.7cm/s of PA and 9.2cm/s of PES seines. 4) In all seines, the force of horizontal movement for the seine setting was values of ranged in disregard.

  • PDF

Evaluation of Flexural Behavior of Hollow Prestressed Concrete Pile for Continuous Pile Wall (주열식 벽체용 중공 프리스트레스트 콘크리트 파일의 휨거동 평가)

  • Lee, Young-Geun;Jang, Min-Jun;Yoon, Soon-Jong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.20-27
    • /
    • 2014
  • In the construction site, various earth retaining systems are developed and applied to maintain stability of excavated area and structures. Among the methods, the underground continuous wall and the column-type diaphragm wall methods are especially used in construction site nearby buildings or roads. However, these methods have some disadvantages such as the difficulty of quality control and long curing time because these methods need to cast fresh concrete at the construction site. In addition, these methods are usually applied to the site for the temporary purpose. In this paper, we suggest precast hollow prestressed concrete pile for continuous pile wall system. To investigate the structural behavior of suggested pile, which is the main member of the suggested system, tests pertaining to the structural behavior and prestressing force applied in the pile are conducted. From the test results, it was found that the prestressing force measured is sufficient compared with the value obtained by the design equation and the cracking moment measured is 34% higher than the design value. In addition to the above, this precast hollow prestressed concrete pile has an additional safety margin that the maximum moment is 59.2% higher than the cracking moment which is one of the serviceability limits for the design of the system.

A STUDY ON THE STRESS DISTRIBUTION OF POSTERIOR FIXED PARTIAL DENTURE WITH VARIOUS ALL-CERAMIC SYSTEMS (구치부 고정성 국소의치에서 전부도재 시스템에 따른 응력분포에 관한 연구)

  • Kang Han-Joong;Dong Jin-Keun;Oh Sang-Chun;Lee Hae-Hyoung;Song Ki-Chang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.204-217
    • /
    • 2005
  • Purpose. The purpose of this study was to analyze stress distribution of all ceramic posterior fixed partial denture using a three dimensional finite element method. Material and method. A three dimensional finite element model was created to demonstrate all-ceramic posterior fixed partial denture and then this computer model measured the stress distribution of the all ceramic bridges which has a ceramic core materials such as Zirconia, IPS Empress. 2. In-Ceram zirconia, Metal-Ceramic. Also the stress distribution was examined according to loading sites when force was applied to sites such as the central area of second premolar the mesial connector of pontic, the central fossa of pontic, the distal connector of pontic, and the central fossa of second molar. Results. 1. In all the materials of the core in this study, von Mises stress indicated that the stress increased as force was applied to loaded sites, just at those points, on the connector, and the margin in the area adjacent to the connectors. 2. The maximum principal stress was much higher in the lower part of the connectors than in any other region. 3. As the load was applied to the different locations, the research showed a consistent increase of stress in the lower connectors. The maximum value of the von Mises stress was two or three times greater when the load was applied directly to the connectors rather than indirectly through another stressed region. 4. In the case of In-Ceram zirconia, the stress in lower connectors was the highest of all the reference points, the stress showed 75% of all the maximum stress. Ziconia showed 72%, Metal Ceramic 67% and IPS Empress 2 50%. 5. In the case of Ziconia, the stress was well dispersed in each reference point that the stress differences were smaller when compared to In-Cream ziconia.

Changes in CGRP-immunoreactive Nerve Fibers during Expansion of Midpalatal Suture of the Rat (백서 정중구개봉합 확대후의 CGRP 면역반응 신경섬유의 변화)

  • Kim, Bo-Kyung;Park, Kuk-Pil;Kyung, Hee-Moon;Kwon, Oh-Won;Sung, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.29 no.1 s.72
    • /
    • pp.73-81
    • /
    • 1999
  • Midpalatal suture expansion is often used for patients haying narrow maxillary arch, cleft palate, respiratory handicap with narrow nasal cavity. CGRP has been known as a modulator of pain transmission in central nervous system and a local effector to peripheral tissue causing vasodilation, increase of blood flow, modulation of immune system, regulation of macrophagic function and stimulation of bone formation. To investigate changes of CGRP-immunoreactive nerve fibers in midpalatal suture during the expansion, immunohistochemical study was performed by using rats. Experimental rats (10 weeks, 250 gm) were divided into five groups (control, 1, 4, 7, 14 days group (each n=4) and applied orthodontic force (approximately 200gm) to upper anterior incisors. Frozen sections of midpalatal suture area were immunostained by using rabbit antisera. The results were as follows. ${\cdot}$ The CGRP-immunoreactive nerve fibers were hardly observed in control group. ${\cdot}$ In 1 day group, the CGRP-immunoreactive nerve fibers were more increased around the vessels than control group. ${\cdot}$ In 4 days group, the CGRP-immunoreactive nerve fibers were more increased than control group, but not more increased than 1 day group. Vascular diameter was more enlarged. ${\cdot}$ In 7 days group, especially, hematoxilin affinity of cells was remarkable and cells were arranged along the bone margin. The CGRP-immunoreactive nerve fibers were more reduced than 4 days group and vascular diameter was also reduced. ${\cdot}$ In 14 days group, the CGRP-immunoreactive nerve fibers were similar to those of 7 days group and the irregularity of bone margin was almost recoverd. In Conclusion, the CGRP-immunoreactive nerve fibers nay be related to initial neurogenic inflammatory reaction in expanding mid-palatal suture.

  • PDF

A STUDY OF VON-MISES YIELD STRENGTH AFTER MANDIBULAR SAGITTAL SPLIT RAMUS OSTEOTOMY (하악지시상분할골절단술 시행 후 von-Miese 항복강도에 대한 유한요소법적 연구)

  • Yoon, Ok-Byung;Kim, Yeo-Gab
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.3
    • /
    • pp.196-204
    • /
    • 2002
  • For the study of its stability when the screw has been fixed after sagittal split ramus osteotomy(SSRO) of the mandible, the methods of screw arrangement are classified into two types, triangular and straight. The angles of screws to the bone surface are classified as perpendicular arrangements, the $60^{\circ}$ anterioinferior screw, known as triangular, and the most posterior screw, called straight arrangement, thus there are four types. The finite element method model has been made by using a three dimensional calculator and a supercomputer. The load directions are to the anterior teeth, premolar region, and molar region, and the bite force is 1 Kgf to each region. The distribution of stress, the von-Mises yield strength, and safety of margin refer to the total sum of transformed energy have been studied by comparison with each other. The following conclusion has been researched : 1. When shear stress is compared, in the triangular arrangement in the form of "ㄱ", the anterosuperior screw is seen at contributing to the support of the bone fragment. In the straight arrangement, substantial stress is seen to be concentrated on the most posterior angled screw. 2. When the von-Mises yield strength is compared, it seemed that the stress concentration on the angled anteroinferior screw is higher, it shows a higher possibility of fracture than any other screw. In the straight arrangement, stress appeared to be concentrated on the most posteriorly angled screw. 3. When the safety margins of the transfomed energy are compared, the energy conduction is much greater in the case of the angled screw than in the case of the perpendicular screw. The triangular arrangement in the form of "ㄱ" shows a superior clinical sign to that of the straight arrangement. Judging from the above results, when the screw fixation is made after SSRO in practical clinical cases, two screws should be inserted in the superior border of mandibular ramus and a third screw of mandibular inferior border should be inserted in the form of triangular. All screws on the bony surface should be placed perpendicularly-$90^{\circ}$ angles apparently best promote bony support and stability.

In vitro study of compressive fracture strength of Empress 2 crowns cemented with various luting agents

  • Kim Min-Ho;Yang Jae-Ho;Lee Sun-Hyung;Chung Hun-Young;Chang Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.260-272
    • /
    • 2001
  • All-ceramic restorations have had a more limited life expectancy than metal ceramic restorations because of their low strength. Their relatively lower strength and resistance to fracture have restricted the use of all-ceramic crowns to anterior applications where occlusal loads are lower. But there has been increasing interest in all-ceramic restorations because patients are primarily concerned with improved esthetics. Many efforts have been made to in prove the mechanical properties of dental ceramics. This study was designed to elucidate the influence of the luting agent on the strength of the Empress 2 crown (staining technique) cemented on human teeth. Seventy extracted human permanent molar teeth were chosen. Teeth were prepared for Empress 2 crowns with milling machine on a surveyor. A dental bur was placed in the mandrel that was positioned so that the long axis of the bur was perpendicular to the surveyor base. Dimensions of the Empress 2 crown preparation were $6^{\circ}$ taper on each side, $1.5{\pm}0.1mm$ shoulder margin, and 4mm crown height. The luting cements used in this study were as follow: 1. Uncemented 2. Zinc phosphate cements (Confi-Dental) 3. Conventional glass ionomer cement : Fuji 1 (GC) 4. Resin-modified glass ionomer cements : Fuji plus (GC) 5. Adhesive cements : Panavia F (Kuralay), Variolink II (Vivadent), Choice (Bisco). Fracture test using Instron. The crowns were loaded in compressive force to evaluate the effect of these cements on the breaking strength of these all-ceramic crowns. A steel ball with a diameter of 4mm was placed on the occlusal surface and load was applied to the steel ball by a cylindrical bolt with a crosshead speed of 0.5mm per minute until fracture occurred. The fractured surface was examined using Scanning Electron Microscopic Image (SEM) to discover the correlation between fracture strength and bonding capacity. Within the limitation of this in vitro study design, the results were as follows : 1. fomentations significantly increased the fracture resistance of Empress ceramic crowns compared to control. Uncemented (206.9 N): ZPC (812.9 N): Fuji 1 (879.5 N): Fuji Plus (937.7 N): Choice (1105.4 N): Variolink II (1221.1 N): Panavia F (1445.2 N). 2. Resin luting agent, treated by a silane bond enhancing agents, yielded a significant increase in fracture resistance. In some of the Panavia F group, a fracture extended into dentin. 3. According to SEM images of fractured Empress crowns, the stronger the bond at both interfaces(crown and die), the more fracture strength was acquired.

  • PDF

THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION IN PORCELAIN LAMINATE VENEERS WITH VARIOUS AMOUNTS OF INCISAL COVERAGE AND TYPES OF INCISAL FINISH LINE UNDER TWO LOADING CONDITIONS (절단피개량과 절단변연형태 및 하중각도가 도재라미네이트 베니어 내의 응력분포에 미치는 영향에 관한 삼차원 유한요소법적 연구)

  • Ryoo, Kyung-Hee;Lee, Sun-Hyung;Yang, Jae-Ho;Chung, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.2
    • /
    • pp.143-166
    • /
    • 1999
  • The success of porcelain laminate veneer depends on the bond strength between tooth structure and ceramic restoration and the design of tooth preparation. In particular, incisal coverage and incisal finish line are the two most important factors in long-term fracture resistance. Although the majority of clinicians are practicing incisal coverage and there are various opinions on the geo-metrical ratio between the clinical crown length of the remaining tooth structure and the length of incisal extension in porcelain laminate veneer and the optimal incisal finish lines. scientific evidence still loaves much to be desired. The purpose of this study was to determine the effects of the amounts of incisal coverage and the types of incisal finish line on the stress distribution in maxillary anterior porcelain laminate veneers under two different loading conditions. Three-dimensional finite element models of a maxillary anterior porcelain veneer with differ-ent amounts of incisal coverage ; 0, 1, 2, and 3mm and different incisal finish lines feathered edge, incisal bevel, reverse bevel and lingual chamfer with various amounts of lingual extension were developed. 300N force was applied at the point 0.5mm cervical of the linguoincisal edge in two loading conditions ; A) 125 degrees, B) 132 degrees. Tensile and compressive stress in ceramic and shear stress in the resin cement layer were analyzed using three-dimensional finite element method. The results were as follows : 1. The types of incisal finish line had more influence on the stress distribution in porcelain laminate veneer than the amounts of incisal coverage. 2. In case of no incisal coverage, incisal beveled laminate exhibited more evenly distributed tensile stress than feathered edged laminate. And in case of incisal coverage, reverse beveled laminate and lingual chamfered laminate with 1mm lingual extension exhibited more evenly distributed tensile stress than lingual chamfered laminates with 2mm and 3mm lingual extension. 3. As long as the lingual chamfer goes, less tensile stress was found at the incisal edge, while much more tensile stress was found at the lingual margin area in proportion to the length of lingual extension. 4. Under 125 degree load, tensile stress in porcelain laminate veneer had increased compared with that under 132 degree load and the difference exhibited by the change of the amount of tooth support was larger. 5. The types of incisal finish line and the distance from the incisal finish line to the loading point had more influence on the shear stress distribution in the resin cement layer than the amounts of incisal coverage. In contrast loading condition had little influence.

  • PDF

A Study on the Investment Effect of Public Accelerator (공공 액셀러레이터 투자 효과에 관한 연구)

  • Hong, JungOh;Kim, Moon-Kyum
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.17 no.3
    • /
    • pp.19-31
    • /
    • 2022
  • Currently, the role of public accelerators in the domestic accelerator market is gradually expanding. Accordingly, in order to establish relevant policies properly, it is necessary to check the effect and validity of public accelerators' investment. However, there is no quantitative research conducted on domestic accelerators, using their financial data, as domestic accelerators have a short history and quantitative data on them are not disclosed. Therefore, this study conducted an empirical analysis with financial data of the startups that received equity investments from public accelerators to confirm the effect of public accelerators'investment in startups. A regression analysis was conducted with financial data from 112 startups that acquired investments from public accelerators in the period of 2016~2020. And the findings are as follows: First, it was found that the initial investment of public accelerators had an effect on the growth and profitability of startups. Specifically, it was confirmed that the initial investment of public accelerators had a positive (+) effect on sales growth rates and total asset growth rates, which are growth indicators. Second, it was found that the joint investment of public accelerators had a significant positive (+) effect on profit margin, an indicator of profitability, rather than on growth. Therefore, it is deemed that it will be a great force for growth if investment in the early-stage startups that showed significant investment results in this study is continuously expanded in combination with support projects, which are a strength of public accelerators. Since this study has confirmed the investment effect of public accelerators, it is deemed necessary to actively promote policies that direct public accelerators' projects toward improving the performance of startups through joint investment with the private sector and supplementing private accelerators' deficiencies.

Comparative study of fracture strength depending on the occlusal thickness of full zirconia crown (완전 지르코니아 크라운의 교합면 두께에 따른 파절강도의 비교 연구)

  • Jang, Soo-Ah;Kim, Yoon-Young;Park, Won-Hee;Lee, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.160-166
    • /
    • 2013
  • Purpose: The purpose of this study was to compare the fracture strength of traditional metal-ceramic crowns and full zirconia crowns according to the occlusal thickness. Materials and methods: A mandibular first molar resin tooth was prepared with 1.5 mm occlusal reduction, 1.0 mm rounded shoulder margin and $6^{\circ}$ taperness in the axial wall. Duplicating the resin tooth, 64 metal dies were fabricated. 48 full zirconia crowns were fabricated using Prettau zirconia blanks by ZIRKONZAHN CAD/CAM and classified into six groups according to the occlusal thickness (0.5 mm, 0.6 mm, 0.7 mm, 0.8 mm, 0.9 mm, 1.0 mm). 16 metal-ceramic crowns were fabricated and classified into two groups according to the occlusal porcelain thickness (1.0 mm, 1.5 mm). All crowns were cemented on each metal die and mounted in a universal testing machine. The load was directed at the functional cusp of each specimen until catastrophic failure occurred. One-way ANOVA, Tukey multiple comparison test (${\alpha}=.05$) and t-test (${\alpha}=.05$) were used. Results: The results were as follows. 1. The test 1 group (646.48 N) showed the lowest fracture strength (P<.05), and the value of the test 2.3.4.5 groups (866.40 N, 978.82 N, 1196.82 N, 1222.41 N) increased as thickness increased, but no significant difference were found with the groups (P>.05). The value of test 6 group (1781.24 N) was significantly higher than those of the other groups (P<.05). 2. There were no significant differences of the fracture strength of metal ceramic crowns according to occlusal porcelain thickness 1.0 mm (2515.71 N) and 1.5 mm (3473.31 N) (P<.05). Conclusion: Full zirconia crown needs to be 1.0 mm or over in occlusal thickness for the posterior area to have higher fracture strength than maximum bite force.

Effects of Fiscal Policy on Labor Markets: A Dynamic General Equilibrium Analysis (조세·재정정책이 노동시장에 미치는 영향: 동태적 일반균형분석)

  • Kim, Sun-Bin;Chang, Yongsung
    • KDI Journal of Economic Policy
    • /
    • v.30 no.2
    • /
    • pp.185-223
    • /
    • 2008
  • This paper considers a heterogeneous agent dynamic general equilibrium model and analyzes effects of an increase in labor income tax rate on labor market and the aggregate variables in Korea. The fiscal policy regarding how the government uses the additional tax revenue may take the two forms: 1) general transfer and 2) earned income tax credit (EITC). The model features are as follows: 1) Workers are heterogeneous in their productivity. 2)Labor is indivisible, hence the analysis focuses on the variation in labor supply through the extensive margin in response to a change in fiscal policy. 3) The incomplete markets are introduced, so individual workers can not perfectly insure themselves against risks related to stochastic changes in income or employment status. 4) The model is of general equilibrium, hence it is equiped to analyze the feedback effect of changes in aggregate variables on individual workers' decisions. In the case of general transfer policy, the government equally distributes the additional tax revenue to all workers regardless of their employment states. Under this policy, an increase in the labor income tax rate dampens work incentives of individual workers so that the aggregate employment rate decreases by 1% compared with the benchmark economy. In the case of EITC policy, only employed workers whose labor incomes are below a certain EITC ceiling are eligible for the EITC benefits. Unlike the general transfer policy, the EITC induces low-income workers to participate the labor market to be eligible for EITC benefits. Hence, the aggregate employment rate may increase by 2.7% at the maximum. As the EITC ceiling increases, too many workers can collect the EITC but the benefits per worker becomes too little so that the increase in employment rate is negligible. By and large, this study demonstrates that EITC may effectively raise the aggregate employment rate, and that it can be a useful policy tool in response to the decrease in the labor force due to population aging as observed in Korea recently.

  • PDF